Three high duty cycle, space-qualified mechanisms

The Michelson Doppler Imager (MDI) is a scientific instrument aboard the Solar and Heliospheric Observatory (SOHO) spacecraft. In 1995, the spacecraft will be put into a halo orbit about the L1 Lagrangian point (equal Sun and Earth gravity). The MDI looks at the sun continuously and takes a picture with a large format CCD camera every 3 seconds. The design goal of the mission is 6 years, so over 60 million pictures will be taken. The sun, being a high intensity source, provides a signal with a single pixel noise level of 0.2 percent. Many images are combined to measure the oscillatory motion of the sun so very high performance is required of the mechanisms in order that they not add noise to the data. The MDI instrument is made up of two parts, the electronics package and the optics package. This paper describes the design and testing of three mechanisms on the MDI which are required to operate large numbers of times.

Akin, David↗

Optically pumped polarized 3 He ++ ion source development for RHIC/EIC

The proposed polarized 3 He ++ acceleration in RHIC and the future Electron-Ion Collider will require about 2×10 11 ions in the source pulse. A new technique had been proposed for production of high intensity polarized 3 He ++ ion beams. It is based on ionization and accumulation of the 3 He gas (polarized by metastability-exchange optical pumping and in the 5T high magnetic field) in the existing Electron Beam Ion Source (EBIS). A novel 3 He cryogenic purification and storage technique was developed to provide the required gas purity. An original gas refill and polarized 3 He gas injection to the EBIS long drift tubes, (which serves as the storage cell) were developed to ensure polarization preservation. An infrared laser system for optical pumping and polarization measurements in the high 3–5 T field has been developed. The 3 He polarization 80–85% (and sufficiently long ~30 min relaxation time) was obtained in the “open” cell configuration with refilling valve tube inlet and isolation valve closed. The development of the spin-rotator and 3 He 4 He absolute nuclear polarimeter at 6 MeV 3 He ++ beam energy is also presented here in this work.

43 PARTICLE ACCELERATORS↗

Model-independent determination of the dipole response of 66 Zn using quasimonoenergetic and linearly polarized photon beams

Background: Photon strength functions are an important ingredient in calculations relevant for the nucleosynthesis of heavy elements. The relation to the photoabsorption cross section allows to experimentally constrain photon strength functions by investigating the photoresponse of atomic nuclei. Purpose: Here, we determine the photoresponse of 66 Zn in the energy region of 5.6 MeV to 9.9 MeV and analyze the contribution of the 'elastic' decay channel back to the ground state. In addition, for the elastic channel electric and magnetic dipole transitions were separated. Methods: Nuclear resonance fluorescence experiments were performed using a linearly polarized quasi-monoenergetic photon beam at the High Intensity γ-ray Source. Photon beam energies from 5.6 to 9.9 MeV with an energy spread of about 3% were selected in steps of 200–300 keV. Two high purity germanium detectors were used for the subsequent γ-ray spectroscopy. Results: Full photoabsorption cross sections are extracted from the data making use of the monoenergetic character of the photon beam. For the ground-state decay channel, the average contribution of electric and magnetic dipole strengths is disentangled. The average branching ratio back to the ground state is determined as well. Conclusions: The new results indicate lower cross sections when compared to the values extracted from a former experiment using bremsstrahlung on 66 Zn. In the latter, the average branching ratio to the ground state is estimated from statistical-model calculations in order to analyze the data. Corresponding estimates from statistical-model calculations underestimate this branching ratio compared to the values extracted from the present analysis, which would partly explain the high cross sections determined from the bremsstrahlung data.

59 ≤ A ≤ 89↗

Spectral Changes in Metal Halide and High-pressure Sodium Lamps Equipped with Electronic Dimming

Electronic dimming of high-intensity discharge lamps offers control of photosynthetic photon flux (PPF) but is often characterized as causing significant spectral changes. Growth chambers with 400-W metal halide (MH) and high-pressure sodium (HPS) lamps were equipped with a dimmer system using silicon-controlled rectifiers (SCR) as high-speed switches. Phase control operation turned the line power off for some period of the alternating current cycle. At full power, the electrical input to HPS and MH lamps was 480 W (root mean squared) and could be decreased to 267 W and 428 W, respectively, before the arc was extinguished. Concomitant with this decrease in input power, PPF decreased by 60% in HPS and 50% in MH. The HPS lamp has characteristic spectral peaks at 589 and 595 nm. As power to the HPS lamps was decreased, the 589-nm peak remained constant while the 595-nm peak decreased, equaling the 589-nm peak at 345-W input, and the 589-nm peak was almost absent at 270-W input. The MH lamp has a broader spectral output but also has a peak at 589 nm and another smaller peak at 545 nm. As input power to the MH lamps decreased, the peak at 589 diminished to equal the 545-nm peak. As input power approached 428 W, the 589-nm peak shifted to 570 nm. While the spectrum changed as input power was decreased in the MH and HPS lamps, the phytochrome equilibrium ratio (P(sub fr):P(sub tot)) remains unchanged for both lamp types.

Bubenheim, David L.↗

Spectral Changes in Metal Halide and High-Pressure Sodium Lamps Equipped with Electronic Dimming

Electronic dimming of high-intensity discharge lamps offers control of Photosynthetic Photon Flux (PPF) but is often characterized as causing significant spectral changes. Growth chambers with 400-W Metal Halide (MH) and High-Pressure Sodium (HPS) lamps were equipped with a dimmer system using Silicon-Controlled Rectifiers (SCR) as high-speed switches. Phase control operation turned the line power off for some period of the alternating current cycle. At full power, the electrical input to HPS and MH lamps was 480 W (root mean squared) and could be decreased to 267 W and 428 W, respectively, before the arc was extinguished. Concomitant with this decrease in input power, PPF decreased by 60% in HPS and 50% in MH. The HPS lamp has characteristic spectral peaks at 589 and 595 nm. As power to the HPS lamps was decreased, the 589-nm peak remained constant while the 595-nm peak decreased, equaling the 589-nm peak at 345-W input, and 589-nm peak was almost absent at 270-W input. The MH lamp has a broader spectral output but also has a peak at 589 nm and another smaller peak at 545 nm. As input power approached 428 W, the 589-nm peak shifted to 570 nm. While the spectrum changed as input power was decreased in the MH and HPS lamps, the phytochrome equilibrium ratio (P(sub ft):P(sub tot)) remains unchanged for both lamp types.

Bubenheim, David L.↗

The J/ψ-007 Experiment: A Search for the LHCB Charm Pentaquarks in Hall C at Jefferson Lab

In the Jefferson Lab E12-16-007 (J/ψ- 007) experiment we measured the differential J/ψ photo-production cross section as a function of photon energy, Ey and Mandelstam variable t- the momentum transfer from the initial photon to the produced J/ψ- in the energy region where all the charm pentaquark states were discovered by the LHCb (Large Hadron Collider beauty) collaboration. The J/ψ-007 experiment was conducted in the experimental Hall C of the Thomas Jefferson National Accelerator Facility using a high-intensity real photon beam generated by a 10.6 GeV incident electron beam traversing a copper radiator upstream of a liquid hydrogen target. Two arm spectrometers of Hall C, HMS (High Momentum Spectrometer), and SHMS (Super High Momentum Spectrometer) were used to detect the e + e - dilepton J/ψ decay pairs in coincidence. The spectrometers' four momentum and angle settings scanned a photon beam energy range between 9.1 and 10.6 GeV and |t| up to 5 GeV 2 . An enhanced sensitivity to the s-channel resonant J/ψ photo-production was achieved by optimizing the spectrometer settings at a higher t region where the non-resonant standard t-channel J/ψ production cross section is strongly suppressed. No evidence for pentaquarks was observed and, the cross section upper limits for each LHCb pentaquark candidate were determined and are presented in this document.

Duran, Burcu↗

Active Activation Diagnostics for High Energy X-ray and Neutron Measurements

Nuclear activation is a vital tool for diagnosing the properties of high-energy particles and photons. We investigate several potential reactions and suitable activation materials that could be used to simultaneously measure both neutrons and high-energy bremsstrahlung x-rays using one detector. Such a diagnostic would be valuable and practical for several facilities capable of creating such high-energy neutrons and x-rays. Laser-generated sources, such as NIF(-ARC) or Omega(-EP), have been shown to be capable of creating high-energy x-rays via high-intensity laser interactions and neutrons via DT fusion reactions. Furthermore, current laser technology is driving the demand for higher repetition rate diagnostics, hence we further constrain reaction/activation selections to accommodate high-repletion rate experiments. Our investigation will concentrate on identifying potential short half-life activation materials associated with high-energy x-ray reactions that could be incorporated into the existing realtime neutron activation detectors (RTNADs), an array of 48 activation detectors positioned around the NIF target chamber used to measure the DT neutron yield isotropy. We have identified two materials, gold and neodymium, that appear to be the best candidates to complement the RTNADs, by adding a new high-energy x-ray measurement capability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron precipitation in the post midnight sector of the auroral zones

Comprehensive measurements of the angular distributions and energy spectra of electron intensities with electrostatic analyzer arrays on board the low-altitude satellite Injun 5 are reported. These are for the post-midnight sector of the auroral zones during the high-intensity events accompanying magnetic substorms. Precipitation features on closed terrestrial field lines well equatorward of the trapping boundary for energetic electrons with E greater than 45 keV were examined. No evidences of maxima in the differential energy spectra or of strongly field-aligned currents which are indicative of quasi-static electric fields aligned parallel to the geomagnetic field were found. Precipitation of low-energy electron intensities fluctuated on time scales greater than 2 seconds as viewed at the satellite position. This precipitation was characterized by isotropy for all pitch angles outside the atmospheric backscatter cone.

Frank, L. A.↗

Muscle changes with eccentric exercise: Implications on earth and in space

Recent investigations of fluid pressure, morpholo gy, and enzyme activities of skeletal muscle exercised eccentrically or concentrically in normal human subjects are reviewed. Intramuscular pressures were measured before, during, and after submaximal exercise and correlated with subjective muscle soreness, fiber size, water content, and blood indices of muscle enzymes. High intensity eccentric exercise is characterized by post exercise pain, elevated intramuscular pressures, and swelling of both type 1 and 2 fibers as compared to concentric exercise. Thus, long periods of unaccustomed, high level eccentric contraction may cause muscle injury, fiber swelling, fluid accumulation, elevated intramuscular pressure, and delayed muscle soreness. Training regimens of progressively increasing eccentric exercise, however, cause less soreness and are extremely efficacious in increasing muscle mass and strength. It is proposed that on Earth, postural muscles are uniquely adapted to low levels of prolonged eccentric contraction that are absent during weightlessness. The almost complete absence of eccentric exercise in space may be an important contributor to muscle atrophy and therefore equipment should be designed to integrate eccentric contractions into exercise protocols for long-term spaceflight.

Hargens, Alan R.↗

Next-Generation Sensing Technologies for Exploring Ocean Worlds

Dr. Ved Chirayath's plenary presentation will highlight two instrument technologies he invented at NASA including Fluid Lensing, the first remote sensing technology capable of imaging through ocean waves in 3D at sub-cm resolutions, and MiDAR (Multispectral Imaging, Detection and Active Reflectance), a next-generation active hyperspectral remote sensing and optical communications instrument. Fluid Lensing has been used to provide the first 3D multispectral imagery of shallow marine systems from unmanned aerial vehicles (UAVs, or drones), including coral reefs in American Samoa and stromatolite reefs in Hamelin Pool, Western Australia. MiDAR is being deployed on aircraft, and underwater remotely operated vehicles (ROVs) as a new method to remotely sense living and nonliving structures in extreme environments. MiDAR images targets with high-intensity narrowband structured optical radiation to measure an object's non-linear spectral reflectance, image through fluid interfaces such as ocean waves with active fluid lensing, and simultaneously transmit high-bandwidth data. As an active instrument, MiDAR is capable of remotely sensing reflectance at the centimeter (cm) spatial scale with a signal-to-noise ratio (SNR) multiple orders of magnitude higher than passive airborne and spaceborne remote sensing systems with significantly reduced integration time. This allows for rapid video-frame-rate hyperspectral sensing into the far ultraviolet and VNIR wavelengths. Finally, Chirayath will present preliminary results from NASA NeMO-Net (Neural Multi-Modal Observation and Training Network), the first neural network for global coral reef classification using fluid lensing and MiDAR.

Technologies↗

ASMS 2024 Investigation of Uranyl Perchlorate Anion Complexes in the Gas Phase via Infrared Multiphoton Dissociation and Collision Induced Dissociation

Investigation of Uranyl Perchlorate Anion Complexes in the Gas Phase via Infrared Multiphoton Dissociation and Collision Induced Dissociation Brittany D. M. Hodges, Christopher A. Zarzana, JungSoo Kim, Jonathan Martens, and W. C. M. Berden Introduction (120 words max) Effects of electronic structure on chemical bonding and reactivity play critical roles shaping the chemical bonding and reactivity behaviors of heavy elements. Understanding the role of f electrons in bond formation between the actinide-series elements like uranium with other ligands is critical for solving technical challenges associated with these heavy elements, important to nuclear fuel cycles, efficient separations of rare earth metals, and understanding the chemistry of stored nuclear fuels and related environmental management sites. In this study, we further examine the interactions between uranyl and the perchlorate ion in order to understand the structures of these ions through the use of IRMPD. Here we report the IRMPD spectra of [UO2(ClO4)3]-, [UO3(ClO4)2]-, and a proposed transition state. Methods (120 word max) IRMPD spectra and CID spectra were acquired using a Bruker amaZon QIT/MS instrument at the Free-Electron Lasers for Infrared eXperiments (FELIX) laboratory at Radboud University. The FELIX QIT/MS is modified to allow for the high-intensity tunable IR beam from FELIX to be directed into the ion packet, resulting in multiphoton dissociation that is measured only when the IR frequency is in resonance with an adequately high absorption vibrational mode of the mass-selected complex. DFT geometry optimizations and frequency calculations using the Gaussian suite of programs were performed using B3LYP, TPSSh, and PBE0 level of theory with 6-31+G(d) basis for the O, C, H, and N atoms and the SDD basis set for U. The SDD basis set employs the Stuttgart/Dresden effective core potential. Preliminary Data or Plenary Speakers Abstract (300 words max) Metal ion clusters of uranyl perchlorate were formed via direct electrospray ionization. For each metal ligand complex of interest, the parent ion was isolated and collision induced dissociation fragmentation and Infrared Multiphoton Dissociation (IRMPD) fragmentation spectra were acquired. Results presented here are the first look at the IRMPD spectra of [UO3(ClO4)2]-, [UO2(ClO4)3]-. Structures were examined using Gaussian at different levels of theory B3LYP level of theory, TPPSh and PBE0 levels, to reflect the behaviors of uranium metal ligand complexes most accurately. In these structures, we identified an overlap between each of these uranyl stretches resulting in their largely being obscured by a perchlorate mode. The CID product spectra agree with similar structures reported by Groenewold for uranyl nitrate in 2006 (10.1021/ja058106n).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ANS results on X-ray binaries

A short description is given of the Astronomical Netherlands Satellite ANS and the X-ray instruments of the Space Research Laboratory in Utrecht. ANS observed in February 1975 a soft _ KeV) X-ray flux in Her-x-I during the 'off'-state with an intensity of a factor I0 lower than observed previously in the 'on'-state. The measured uncorrected intensity is (1.1 ± 0.2)10^(-11) ergs/sq.cm sec in 0.2 - 0.28 keV at earth. The ANS observations on Cyg-X-I are summarized. Duping the May 75 flaring state a very high intensity at 0.5 keV is measured consistent with a power-law Ph0ton-spectrum with index 3.5 and an interstellar absorption of 7.10^(21) atoms/sq.cm, but not consistent with spectra that show an additional cut-off below 1KeV and an absorption of 7 10^(21) atoms/sq.cm. Intensity changes on a time scale of minutes, as observed in Cyg-X-1 lowstate, are not observed during the flaring state.

J. Heise↗

NASA Fluid Lensing & MiDAR: Next-Generation Remote Sensing Technologies for Aquatic Remote Sensing

We present two recent instrument technology developments at NASA, Fluid Lensing and MiDAR, and their application to remote sensing of Earth's aquatic systems. Fluid Lensing is the first remote sensing technology capable of imaging through ocean waves in 3D at sub-cm resolutions. MiDAR is a next-generation active hyperspectral remote sensing and optical communications instrument capable of active fluid lensing. Fluid Lensing has been used to provide 3D multispectral imagery of shallow marine systems from unmanned aerial vehicles (UAVs, or drones), including coral reefs in American Samoa and stromatolite reefs in Hamelin Pool, Western Australia. MiDAR is being deployed on aircraft and underwater remotely operated vehicles (ROVs) to enable a new method for remote sensing of living and nonliving structures in extreme environments. MiDAR images targets with high-intensity narrowband structured optical radiation to measure an objectâ€"TM"s non-linear spectral reflectance, image through fluid interfaces such as ocean waves with active fluid lensing, and simultaneously transmit high-bandwidth data. As an active instrument, MiDAR is capable of remotely sensing reflectance at the centimeter (cm) spatial scale with a signal-to-noise ratio (SNR) multiple orders of magnitude higher than passive airborne and spaceborne remote sensing systems with significantly reduced integration time. This allows for rapid video-frame-rate hyperspectral sensing into the far ultraviolet and VNIR wavelengths. Previously, MiDAR was developed into a TRL 2 laboratory instrument capable of imaging in thirty-two narrowband channels across the VNIR spectrum (400-950nm). Recently, MiDAR UV was raised to TRL4 and expanded to include five ultraviolet bands from 280-400nm, permitting UV remote sensing capabilities in UV A, B, and C bands and enabling mineral identification and stimulated fluorescence measurements of organic proteins and compounds, such as green fluorescent proteins in terrestrial and aquatic organics.

fluid lensing↗

Effects of gas purity on backgrounds of collision reaction cell-equipped MC-ICP-MS

The advent of multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) instruments equipped with collision reaction cells (CRCs) facilitates interference removal/mitigation via online gas phase separations. This approach has proven effective for high intensity ion beams measured on Faraday collectors; however, it has been observed that introduction of gas in the CRC can result in significant background signals relative to the more sensitive ion counters. These backgrounds hinder use of these instruments for low level concentration and isotopic ratio measurements when employing a reaction gas. Here, this work directly evaluates the effect of gas purity on backgrounds of CRC-MC-ICP-MS instruments. Introducing high-purity research grade O 2 (99.999%) into the CRC produces complex background spectra with intensities >10 4 cps observed at most masses across the measured mass range (7-300 m / z ). Some features of the observed spectra (i.e., positive mass defects) can be attributed to molecular compounds comprised of significant hydrogen. Additionally, some specific molecular species can be identified (i.e., MoO x H y + ) and appear to be derived from molybdenum rods comprising the CRC. Further purifying the gas reduces the intensity of these backgrounds by several orders of magnitude, to <10 2 cps in many cases, and reduces complexity of the resulting spectra. This reduction in background appears to be in part driven by removal of impurities (i.e., H 2 O) from the gas. This work demonstrates that additional purification of reaction gases prior to introduction into the CRC significantly reduces backgrounds detected, potentially expanding the utility of CRC-MC-ICP-MS for making low level measurements using inline gas phase ion separations.

Schlieder, Tyler D. [Pacific Northwest National La↗

SpinQuest Polarized Target System

The SpinQuest experiment at Fermilab uses a solid-state polarized ammonia target held at a magnetic field of 5 T, immersed in liquid helium-4, which is held at approximately 1K by the evaporation refrigerator. The refrigerator provides the required cooling power during the dynamic nuclear polarization (DNP) process and the high intensity interaction with the 120 GeV proton beam from the Fermilab main injector. The refrigerator was designed in compliance with the American Society of Mechanical Engineers (ASME) to operate safely at Fermilab. The high pumping capacity ($17,000 \:m^3/h$) roots stack provides the required pumping speed during DNP production data taking and a custom-made radiation hard flow control valve regulates the refrigerator temperature during the thermal equilibrium calibration measurements. The frequency of the microwave generator, an Extended Interaction Oscillator (EIO), is automated to keep the maximum polarization while the (Nuclear Magnetic Resonance) NMR system continuously measures the polarization of the target material. In this talk, an overview of the SpinQuest polarized target system will be presented as well as a brief report of recent commissioning activities and target performance during the early production runs in 2024.

Bandara, Vibodha [Colombo U.]↗

Jovian radiation and charging environment considerations in Galileo

The Galileo spacecraft which will orbit Jupiter in 1987 will encounter one of the most interesting natural environments. These include high energy radiation electrons and ions and magnetospheric plasmas. The evaluation of Galileo design commenced with a careful consideration of the plasma environment and the now standard spacecraft charging analysis. In addition the intense high energy radiation environment has necessitated the consideration of charges deposited internally to the spacecraft. This paper presents some of the analyses and the design changes which have occurred as a result of the above mentioned environmental interaction considerations.

Leung, P.↗

Preliminary results of the 2023 International Fermilab Booster Studies

Here, an overview is given of the methods and preliminary results from dedicated beam studies on three topics conducted over five days in July 2023. In the first study, the Fermilab Booster magnets were held constant at magnetic fields corresponding to the injection energy. The beam loss and emittance growth were observed under varying intensity, tunes, and sextupole resonances. The corresponding beam conditions were also simulated with the MADX-SC code [1]. In the second study, measurements of the vertical half-integer resonance and correction methods are conducted for high-intensity beams ramping in the Booster. Finally, syncho-betatron instabilities are observed during transition-crossing in the Booster under strong space-charge conditions.

43 PARTICLE ACCELERATORS↗

Relativistic plasma physics in supercritical fields

Since the invention of chirped pulse amplification, which was recognized by a Nobel Prize in physics in 2018, there has been a continuing increase in available laser intensity. Combined with advances in our understanding of the kinetics of relativistic plasma, studies of laser-plasma interactions are entering a new regime where the physics of relativistic plasmas is strongly affected by strong-field quantum electrodynamics (QED) processes, including hard photon emission and electron-positron (e⁻-e⁺) pair production. Additionally, this coupling of quantum emission processes and relativistic collective particle dynamics can result in dramatically new plasma physics phenomena, such as the generation of dense e⁻-e⁺ pair plasma from near vacuum, complete laser energy absorption by QED processes, or the stopping of an ultra-relativistic electron beam, which could penetrate a cm of lead, by a hair's breadth of laser light. In addition to being of fundamental interest, it is crucial to study this new regime to understand the next generation of ultra-high intensity laser-matter experiments and their resulting applications, such as high energy ion, electron, positron, and photon sources for fundamental physics studies, medical radiotherapy, and next generation radiography for homeland security and industry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗