Demonstrating Advanced Nuclear Energy Solutions for Net Zero

Background/Objectives. The aggressive goals being set by nation states, communities, and private industry for decarbonization of grid electricity, industrial heat sources, and transportation around the world are imperative to mitigating the devastating effects that we are seeing from climate change. Although many of these goals focus on accomplishments by 2035 or 2050, the decisions that we make today won’t just impact the landscape of energy systems for the next 20 or 30 years—they will shape the world’s environment for centuries to come. That means that we can’t just focus on technologies that will get us to 2050, but technologies that will withstand our energy demands over that long-ranging future. Success will require us to utilize all of the clean energy resources that we have available to meet demands for electricity, heat, and steam, and we will need energy carriers such as hydrogen that do not emit additional greenhouse gases at the point of use. Nuclear energy, ranging from technologies in service today to advanced, higher temperature and modular systems that will be in service this decade, will provide a robust complement to renewable energy resources that operate variably. Researchers across the U.S. Department of Energy laboratory complex are working to advance multiple aspects of these clean energy solutions, with many focusing on integrated energy system solutions that leverage all available clean energy assets to meet wide-ranging energy demands. Approach/Activities. Nuclear energy is a proven, zero-emission option during operation that can provide consistent, dispatchable power to meet electricity demands while also providing high-quality heat that can meet energy demands beyond the electricity sector. Energy system design should seek to maximize these assets. As a dispatchable energy source with a small land utilization footprint, nuclear energy can be collocated with renewable resources, and the smaller systems that will be deployed this decade (ranging from a few megawatts to hundreds of megawatts) can be installed right where that energy is needed. Integrated nuclear and renewable systems will enhance power grid reliability and resilience, and they will help stabilize the grid through their increasingly flexible operation. Licensing, installation, and broad adoption of these advanced nuclear energy systems are expected to progress significantly in the 2020s, but this may be longer than desired by some stakeholders wishing to implement impactful clean energy decisions today. However, one must recall that nuclear energy systems will operate for 80 or more years, as is being demonstrated by current fleet nuclear systems. The nuclear community is extremely thorough in reviewing these systems with regard to safety and security; these efforts ensure that the deployed systems will continue to provide reliable, resilient energy over that operational lifetime. That investment of time up front will ensure that we can support energy demands over the centuries to come. While advanced nuclear technologies move through this process, communities and private industry may choose to install renewable generation systems that can later be coupled to the complementary nuclear systems as they become available—thus moving closer to the net zero goals in the near term. Choosing technologies and deployment configurations that allow small modular nuclear powerhouses to be added to these “energy parks” as they become available will ensure that advanced technologies can be readily adopted to support growing demands for clean energy. Results/Lessons Learned. The primary focus of integrated energy systems (IES) research is to assess the technical and economic potential of novel multi-input, multioutput solutions that are expected to enhance energy system flexibility, reliability, and resilience as we pursue a clean energy transition. Various energy applications and product streams beyond electricity are being evaluated, ranging from generation of potable water to production of hydrogen, fertilizers, synthetic fuels, and various chemicals. In early FY23 Idaho National Laboratory (INL) will commission thermal energy generation systems that emulate nuclear fission energy input using electric heating and will allow for integrated system testing with thermal energy storage, hydrogen production via high temperature electrolysis (HTE), and power systems hardware to demonstrate operation of a clean energy park within a microgrid or larger grid infrastructure, supporting up to 450 kW of heat input via electric heating and demonstrating operation of HTE systems at the multi-hundred kW scale. This presentation will highlight the wide array of RD&D being conducted at INL and partner laboratories to develop and deploy nuclear and renewable-based IES that will be key to achieving our net zero goals, including both computational and experimental demonstrations. By working with key collaborators in industry, analytical st

08 HYDROGEN↗

Heat pipes containing alkali metal working fluid

A technique for improving high temperature evaporation-condensation heat-transfer devices which have important and unique advantage in terrestrial and space energy processing is described. The device is in the form of a heat pipe comprising a sealed container or envelope which contains a capillary wick. The temperature of one end of the heat pipe is raised by the input of heat from an external heat source which is extremely hot and corrosive. A working fluid of a corrosive alkali metal, such as lithium, sodium, or potassium transfers this heat to a heat receiver remote from the heat source. The container and wick are fabricated from a superalloy containing a small percentage of a corrosion inhibiting or gettering element. Lanthanum, scandium, yttrium, thorium, and hafnium are utilized as the alloying metal.

Morris, J. F.↗

Thermal Modeling of a Novel Air-Cooled Temperature Swing Adsorption Compressor (AC-TSAC)

Contaminant removal technology, such as the Carbon Dioxide Removal Assembly (CDRA) on the International Space Station (ISS), is critical to Environmental Close-Loop Life Support Systems (ECLSS), which enable humans to live and work in outer space. The CDRA includes an adsorbent bed, which absorbs CO2 and releases it to a Sabatier reactor for water production when thermally cycled. An effective system would heat and cool the adsorbent quickly and uniformly to maximize the amount of CO2 removed from the cabin. Air-Cooled Temperature Swing Adsorption Compressors (AC-TSAC) are promising because they are a simple alternative to more mechanically-complex compressors currently used on the ISS. The current investigation addresses the thermal modeling of potential AC-TSAC designs. Design trades include bed geometry (rectangular vs. cylindrical), bed structural material, and configuration of heat pipes within the bed. Also investigated is AC-TSAC performance sensitivity to the thermal conductivity of the adsorbent material and the heat pipes, the input power for heating, and various heat loss mechanisms. The results from these studies will inform the design of the next generation of the AC-TSAC, and the thermal modeling results will be validated through testing.

Hannah Alpert↗

Renewable Thermal Energy Systems Designed for Industrial Process Solutions in Multiple Industries

Industrial decarbonization is a key area that must be accelerated, to foster the removal of fossil fuels from the provision of heat, especially at low temperatures less than 300 degrees C. This paper looks at the results of two case studies for understanding the economics and potential for renewable thermal energy systems (RTES), particularly in hybrid configurations to provide industrial process heat (IPH). The first case study looks at heat pumps for district heating, and the second, the use of linear Fresnel collectors (LFCs) coupled with phase change material (PCM) thermal energy storage (TES) for direct steam generation (DSG). Using district heat as an input for the heat pump, three cases were run harvesting energy from ambient water (5 degrees C), sewage water (20 degrees C), and a solar collector (35 degrees C). Accounting for elevated costs of infrastructure for each heat source, the levelized cost of heat (LCOH) of the first case study ranged from $4-$15 per million British Thermal Units (MMBTU). For the second case study modeling LFCs with PCM and TES, the results show that a LCOH of $9-$15 per MMBTU is possible, depending on the direct normal irradiance.

concentrated solar thermal↗

Renewable Thermal Energy Systems Designed for Industrial Process Solutions in Multiple Industries: Preprint

Industrial decarbonization is a key area that must be accelerated, to foster the removal of fossil fuels from the provision of heat, especially at low temperatures less than 300 degrees C. This paper looks at the results of two case studies for understanding the economics and potential for renewable thermal energy systems (RTES), particularly in hybrid configurations to provide industrial process heat (IPH). The first case study looks at heat pumps for district heating, and the second, the use of linear Fresnel collectors (LFCs) coupled with phase change material (PCM) thermal energy storage (TES) for direct steam generation (DSG). Using district heat as an input for the heat pump, three cases were run harvesting energy from ambient water (5 degrees C), sewage water (20 degrees C), and a solar collector (35 degrees C). Accounting for elevated costs of infrastructure for each heat source, the levelized cost of heat (LCOH) of the first case study ranged from $4-$10 per million British Thermal Units (MMBTU). For the second case study modeling LFCs with PCM and TES, the results show that a LCOH of $9-$15 per MMBTU is possible, depending on the direct normal irradiance.

concentrated solar thermal↗

Three-dimension heat transfer program

An IBM 7094, three dimensional, heat transfer program for satellite application is discussed. The program may be applied to all phases of spacecraft life, from launch to orbital quasi-steady state. Launch phase heating includes inputs by radiation from the hot fairing and free molecule flow heating after nose cone ejection. Orbital heat fluxes are accounted for by direct sunlight, earth-reflected sunlight, and earth-emitted input to the satellite. Internal heat exchange by conduction and radiation is determined, provided the appropriate conductances, radiation view factors, and effective emittances are known. A simplified analysis of an active thermal controlled spacecraft is incorporated into the program. One or more surfaces may contain shutter systems which have optical properties specified as a function of shutter opening. The program evaluates the feasibility of any configuration based upon maintaining an internal component within its tolerable temperature limits. The program employs a matrix inversion subroutine (Gauss Elimination Method) to solve the heat balance equations.

COMPUTER PROGRAM↗

Carbon-Carbon Heat Pipe Testing and Evaluation

This report discusses development and proof-of-concept testing of a new lightweight carbon-carbon (C-C) space radiator heat pipe developed under the NASA Civil Space Technology Initiative (CSTI) High Capacity Power Program. The heat pipe was filled with potassium working fluid and tested for 11 hours including startup from ambient temperature with the working fluid initially in the frozen state to near 700 K condenser temperature. Steady-state heat pipe input power during testing was facility limited to about 300 watts, representing about 50 percent of the design input power. Post test inspection showed the heat pipe to be in excellent condition after eight thermal cycles from ambient to steady-state operating temperature. Potential applications, ranging from small spacecraft heat rejection to aircraft and terrestrial uses, are discussed.

Juhasz, Albert J.↗

A Finite Element Method for Compressible and Turbulent Multiphase Flow Instabilities with Heat Transfer

We present a new finite element framework for modeling compressible, turbulent multiphase flows with heat transfer. For two-fluid systems with a free surface, the Volume of Fluid (VOF) method is implemented without the need for interface reconstruction, while turbulence is resolved using a dynamic Vreman large eddy simulation (LES) model. Unlike most two-phase VOF studies, which neglect heat transfer, the present approach incorporates energy transport equations within the VOF formulation to account for heat exchange, an effect particularly important in turbulent flows. Conjugate heat transfer is often challenging in finite volume methods, which require explicit specification of heat fluxes at the solid–fluid interface, limiting accuracy and predictive capability. By contrast, the finite element formulation does not require heat flux inputs, allowing more accurate and robust simulation of heat transfer between solids and fluids. The method is demonstrated through three representative cases. First, a two-fluid instability with a single-mode perturbation is simulated and validated against analytical growth rates. Second, conjugate heat transfer is examined in a high-temperature flow over a cold metal cylinder, with validation performed both quantitatively—via pressure coefficient comparisons with experimental data—and qualitatively using vector field topology. Finally, compressible spray injection and breakup are modeled, demonstrating the ability of the framework to capture interfacial dynamics and atomization under turbulent, high-speed conditions. In the compressible spray injection and breakup case, the results indicate that the finite element formulation achieved higher predictive accuracy and robustness than the finite-volume method. With the same mesh resolution, the FEM reduced the root mean square error (RMSE) and mean absolute percentage error (MAPE) from 6.96 mm and 26.0% (for the FVM) to 4.85 mm and 12.7%, respectively, demonstrating improved accuracy and robustness in capturing interfacial dynamics and heat transfer. The study also introduced vector field topology to visualize and interpret coherent flow structures and instabilities, offering insights beyond conventional scalar-field analyses.

97 MATHEMATICS AND COMPUTING↗

An active thermal compensator for closed-cycle helium refrigerators

A technique was developed for reducing the amplitude of the temperature oscillation in He closed-cyle refrigerators. The device uses a semiconductor diode as a heating element to actively supply a small oscillating input of heat at a point between the laser and the cold-tip to cancel the heat oscillations due to the refrigerator. It was found that the heater diode could drive the temperature of the heat sink more effectively, i.e., with lower current and therefore less heat, if the heat sink was insulated slightly from the rest of the mount. A sine-wave generator was used to drive the programmable supply which provided the offset current to the heater diode. By matching the frequency and phase of the oscillator to that of the refrigerator cycle, and by adjusting the amplitude of the oscillator signal, the temperature fluctuations at the laser could be minimized. Residual fluctuations were about 0.003K peak-to-peak, at an operating temperature of 9.5K.

Jennings, D. E.↗

An asymptotic-preserving stochastic Galerkin method for the radiative heat transfer equations with random inputs and diffusive scalings

In this paper, we develop an Asymptotic-Preserving (AP) stochastic Galerkin scheme for the radiative heat transfer equations with random inputs and diffusive scalings. In this problem the random inputs arise due to uncertainties in cross section, initial data or boundary data. We use the generalized polynomial chaos based stochastic Galerkin (gPC-SG) method, which is combined with the micro–macro decomposition based deterministic AP framework in order to handle efficiently the diffusive regime. For linearized problem we prove the regularity of the solution in the random space and consequently the spectral accuracy of the gPC-SG method. We also prove the uniform (in the mean free path) linear stability for the space-time discretizations. Several numerical tests are presented to show the efficiency and accuracy of proposed scheme, especially in the diffusive regime.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

NASA Lewis steady-state heat pipe code users manual

The NASA Lewis heat pipe code was developed to predict the performance of heat pipes in the steady state. The code can be used as a design tool on a personal computer or with a suitable calling routine, as a subroutine for a mainframe radiator code. A variety of wick structures, including a user input option, can be used. Heat pipes with multiple evaporators, condensers, and adiabatic sections in series and with wick structures that differ among sections can be modeled. Several working fluids can be chosen, including potassium, sodium, and lithium, for which monomer-dimer equilibrium is considered. The code incorporates a vapor flow algorithm that treats compressibility and axially varying heat input. This code facilitates the determination of heat pipe operating temperatures and heat pipe limits that may be encountered at the specified heat input and environment temperature. Data are input to the computer through a user-interactive input subroutine. Output, such as liquid and vapor pressures and temperatures, is printed at equally spaced axial positions along the pipe as determined by the user.

Tower, Leonard K.↗

Method and apparatus for checking fire detectors

A fire detector checking method and device are disclosed for nondestructively verifying the operation of installed fire detectors of the type which operate on the principle of detecting the rate of temperature rise of the ambient air to sound an alarm and/or which sound an alarm when the temperature of the ambient air reaches a preset level. The fire alarm checker uses the principle of effecting a controlled simulated alarm condition to ascertain wheather or not the detector will respond. The checker comprises a hand-held instrument employing a controlled heat source, e.g., an electric lamp having a variable input, for heating at a controlled rate an enclosed mass of air in a first compartment, which air mass is then disposed about the fire detector to be checked. A second compartment of the device houses an electronic circuit to sense and adjust the temperature level and heating rate of the heat source.

Clawson, G. T.↗

Solutionization via Severe Plastic Deformation: Effect on Natural Aging in an Al-Mg-Si-(Mn) Alloy

Shear Assisted Processing and Extrusion (ShAPE), a severe plastic deformation technique that is fast and scalable, was used to produce thin-wall tubing from alloy 6082 (Al-0.8Mg-0.9Si-0.7Mn) with in-situ solutionization during processing quickly followed by quenching. Quench medium and input material heat treatment were varied and natural aging behavior (T1 heat treatment) was evaluated using tensile testing. As-cast input material was found to have higher strength early in post-ShAPE natural aging and homogenized input material was found to have strengthening during natural aging. Compared to air quenching, water quenching gave greater strength both early in and after natural aging. These observations along with microscopy suggest that: 1. air quenching was too slow; 2. as-cast material was not fully solutionized but plastic deformation broke up the coarse intermetallic particles, which provided strengthening; and 3. homogenized material was solutionized well, which led to good natural aging behavior.

Milligan, Brian K.↗

Control of internal transport barriers in magnetically confined tokamak burning plasmas

The initiation, termination, and control of internal transport barriers associated with E × B flow shear near local minima of magnetic shear are examined for burning plasmas to determine if the positive feedback loops between profiles, instability, transport, and flow shear operate in regimes with fusion self-heating. A five-field transport model for the evolution of profiles of density, ion and electron temperature, ion and electron fluctuations, and radial electric field is utilized to examine the efficacy of controls associated with external inputs of heat and particles, including neutral beam injection, RF, pellets, and gas puffing. The response of the plasma to these inputs is studied in the presence of self-heating. The latter is affected by the external inputs and their modification of profiles and is, therefore, not an external control. Provided sufficient external power is applied, internal transport barriers can be created and controlled, both in ion and electron channels. Barrier control is sensitive to the locations of power deposition and pellet ablation, as well as temporal sequencing of external inputs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of Surface Roughness, Oxidation, and Temperature on the Emissivity of Reactor Pressure Vessel Alloys

Thermal radiation will be an important mode of heat transfer in future high-temperature reactors and in off-normal high-temperature scenarios in present reactors. In this work, spectral directional emissivities of two reactor pressure vessel (RPV) candidate materials were measured at room temperature after exposure to high-temperature air. In the case of SA508 steel, significant increases in emissivity were observed due to oxidation. In the case of Grade 91 steel, only very small increases were observed under the tested conditions. Effects of roughness were also investigated. To study the effects of roughening, unexposed samples of SA508 and Grade 91 steel were roughened via one of either grinding or shot-peening before being measured. Significant increases were observed only in samples having roughness exceeding the roughness expected of RPV surfaces. While the emissivity increases for SA508 from oxidation were indeed significant, the measured emissivity coefficients were below that of values commonly used in heat transfer models. Based on the observed experimental data, recommendations for emissivity inputs for heat transfer simulations are provided.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mars Propellant Liquefaction and Storage Performance Modeling using Thermal Desktop with an Integrated Cryocooler Model

NASAs current Mars architectures are assuming the production and storage of 23 tons of liquid oxygen on the surface of Mars over a duration of 500+ days. In order to do this in a mass efficient manner, an energy efficient refrigeration system will be required. Based on previous analysis NASA has decided to do all liquefaction in the propulsion vehicle storage tanks. In order to allow for transient Martian environmental effects, a propellant liquefaction and storage system for a Mars Ascent Vehicle (MAV) was modeled using Thermal Desktop. The model consisted of a propellant tank containing a broad area cooling loop heat exchanger integrated with a reverse turbo Brayton cryocooler. Cryocooler sizing and performance modeling was conducted using MAV diurnal heat loads and radiator rejection temperatures predicted from a previous thermal model of the MAV. A system was also sized and modeled using an alternative heat rejection system that relies on a forced convection heat exchanger. Cryocooler mass, input power, and heat rejection for both systems were estimated and compared against sizing based on non-transient sizing estimates.

fluid modeling↗

Mars Propellant Liquefaction Modeling in Thermal Desktop

NASAs current Mars architectures are assuming the production and storage of 23 tons of liquid oxygen on the surface of Mars over a duration of 500+ days. In order to do this in a mass efficient manner, an energy efficient refrigeration system will be required. Based on previous analysis NASA has decided to do all liquefaction in the propulsion vehicle storage tanks. In order to allow for transient Martian environmental effects, a propellant liquefaction and storage system for a Mars Ascent Vehicle (MAV) was modeled using Thermal Desktop. The model consisted of a propellant tank containing a broad area cooling loop heat exchanger integrated with a reverse turbo Brayton cryocooler. Cryocooler sizing and performance modeling was conducted using MAV diurnal heat loads and radiator rejection temperatures predicted from a previous thermal model of the MAV. A system was also sized and modeled using an alternative heat rejection system that relies on a forced convection heat exchanger. Cryocooler mass, input power, and heat rejection for both systems were estimated and compared against sizing based on non-transient sizing estimates.

Cryogenics↗

Performance Optimization of Alternative Lower Global Warming Potential Refrigerants in Mini-Split Room Air Conditioners

Oak Ridge National laboratory (ORNL) recently conducted extensive laboratory, drop-in investigations for lower Global Warming Potential (GWP) refrigerants to replace R-22 and R-410A. ORNL studied propane, DR-3, ARM-20B, N-20B and R-444B as lower GWP refrigerant replacement for R-22 in a mini-split room air conditioner (RAC) originally designed for R-22; and, R-32, DR-55, ARM-71A, and L41-2, in a mini-split RAC designed for R-410A. We obtained laboratory testing results with very good energy balance and nominal measurement uncertainty. Drop-in studies are not enough to judge the overall performance of the alternative refrigerants since their thermodynamic and transport properties might favor different heat exchanger configurations, e.g. cross-flow, counter flow, etc. This study compares optimized performances of individual refrigerants using a physics-based system model tools. The DOE/ORNL Heat Pump Design Model (HPDM) was used to model the mini-split RACs by inputting detailed heat exchangers geometries, compressor displacement and efficiencies as well as other relevant system components. The RAC models were calibrated against the lab data for each individual refrigerant. The calibrated models were then used to conduct a design optimization for the cooling performance by varying the compressor displacement to match the required capacity, and changing the number of circuits, refrigerant flow direction, tube diameters, air flow rates in the condenser and evaporator at 100% and 50% cooling capacities. This paper compares the optimized performance results for all alternative refrigerants and highlights best candidates for R-22 and R-410A replacement.

GWP↗