Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heating experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Heat transfer, friction, and rheological characteristics of antimisting kerosene

Experiments were performed to determine the skin friction and heat transfer behavior of antimisting kerosene (AMK) in pipe flows. The additive used was FM-9. Based on the results of the experiments, which identify high viscosity and viscoelasticity for AMK, it is recommended that AMK be degraded. Sufficient degradation produces behavior similar to that of jet A.

Matthys, E.↗

Airborne brightness temperature measurements of the polar winter troposphere as part of the Airborne Arctic Stratosphere Experiment 2 and the effect of brightness temperature variations on the diabatic heating in the lower stratosphere

In this paper we report radiometric measurements of tropospheric brightness temperatures obtained during the AASE 2 experiment. These measurements represent the first attempt to characterize effective radiative temperatures as seen from above the troposphere during the Arctic winter. The reported measurements include brightness temperatures at 6.7 and 10.5 microns as seen from the NASA DC-8 aircraft flying at about 11 km altitude. We also present radiative transfer calculations to estimate the effect of tropospheric brightness temperature on the lower stratospheric heating rates. Because of the recent massive eruption of the Pinatubo volcano, we also discuss the effects of a volcanic aerosol layer. It is concluded that small particles like the volcanic aerosol or polar stratospheric clouds (PSCs) type 1 do not affect stratospheric heating rates by much; on the other hand, larger particles, PSCs types 2 and 3, may have significant effects on heating rates and consequently on dynamics of the lower stratosphere. The dynamical effects of local stratospheric temperature variations are briefly discussed.

Valero, Francisco P. J.↗

Airborne Brightness Temperature Measurements of the Polar Winter Troposphere as Part of the Airborne Arctic Stratosphere Experiment 2 and the Effect of Brightness Temperature Variations on the Diabatic Heating in the Lower Stratosphere

In this paper we report radiometric measurements of tropospheric brightness temperatures obtained during the AASE 2 experiment. These measurements represent the first attempt to characterize effective radiative temperatures as seen from above the troposphere during the Arctic winter. The reported measurements include brightness temperatures at 6.7 and 10.5 micrometers as seen from the NASA DC-8 aircraft flying at about 11 km altitude. We also present radiative transfer calculations to estimate the effect of tropospheric brightness temperature on the lower stratospheric heating rates. Because of the recent massive eruption of the Pinatubo volcano, we also discuss the effects of a volcanic aerosol layer. It is concluded that small particles like the volcanic aerosol or PSCs type 1 do not affect stratospheric heating rates by much; on the other hand, larger particles, PSCs types 2 and 3, may have significant effects on heating rates and consequently on dynamics of the lower stratosphere. The dynamical effects of local stratospheric temperature variations are briefly discussed.

Valero, Francisoco P. J.↗

Conceptual design of two-phase fluid mechanics and heat transfer facility for spacelab

Five specific experiments were analyzed to provide definition of experiments designed to evaluate two phase fluid behavior in low gravity. The conceptual design represents a fluid mechanics and heat transfer facility for a double rack in Spacelab. The five experiments are two phase flow patterns and pressure drop, flow boiling, liquid reorientation, and interface bubble dynamics. Hardware was sized, instrumentation and data recording requirements defined, and the five experiments were installed as an integrated experimental package. Applicable available hardware was selected in the experiment design and total experiment program costs were defined.

North, B. F.↗

Thermal and orbital analysis of Earth monitoring Sun-synchronous space experiments

The fundamentals of an Earth monitoring Sun-synchronous orbit are presented. A Sun-synchronous Orbit Analysis Program (SOAP) was developed to calculate orbital parameters for an entire year. The output from this program provides the required input data for the TRASYS thermal radiation computer code, which in turn computes the infrared, solar and Earth albedo heat fluxes incident on a space experiment. Direct incident heat fluxes can be used as input to a generalized thermal analyzer program to size radiators and predict instrument operating temperatures. The SOAP computer code and its application to the thermal analysis methodology presented, should prove useful to the thermal engineer during the design phases of Earth monitoring Sun-synchronous space experiments.

Killough, Brian D.↗

OEX - Use of the Shuttle Orbiter as a research vehicle

The Orbiter Experiments Program to provide research instrumentation on the Shuttle Orbiter is discussed. Flight aerodynamic problems such as ground-based data limitations, rarefied flow effects, body flap and control surface effectiveness, and windward surface heat transfer are reviewed. Experiments currently under development are described, including experiments on tile gaps and wall catalytic effects which provide the opportunity to obtain data not available in ground facilities and apply the results to improvements in the Orbiter's thermal protection system. Such experiments combined with other instrumentation on the Orbiter should provide benchmark flight data which can make a significant impact on the design of future space transportation systems.

Jones, J. J.↗

Heat transfer in rotating serpentine passages with selected model orientation for smooth or skewed trip walls

Experiments were conducted to determine the effects of model orientation as well as buoyancy and Coriolis forces on heat transfer in turbine blade internal coolant passages. Turbine blades have internal coolant passage surfaces at the leading and trailing edges of the airfoil with surfaces at angles which are as large as +/- 50 to 60 degrees to the axis of rotation. Most of the previously-presented, multiple-passage, rotating heat transfer experiments have focused on radial passages aligned with the axis of rotation. Results from serpentine passages with orientations 0 and 45 degrees to the axis of rotation which simulate the coolant passages for the mid chord and trailing edge regions of the rotating airfoil are compared. The experiments were conducted with rotation in both directions to simulate serpentine coolant passages with the rearward flow of coolant or with the forward flow of coolant. The experiments were conducted for passages with smooth surfaces and with 45 degree trips adjacent to airfoil surfaces for the radial portion of the serpentine passages. At a typical flow condition, the heat transfer on the leading surfaces for flow outward in the first passage with smooth walls was twice as much for the model at 45 degrees compared to the model at 0 degrees. However, the differences for the other passages and with trips were less. In addition, the effects of buoyancy and Coriolis forces on heat transfer in the rotating passage were decreased with the model at 45 degrees, compared to the results at 0 degrees. The heat transfer in the turn regions and immediately downstream of the turns in the second passage with flow inward and in the third passage with flow outward was also a function of model orientation with differences as large as 40 to 50 percent occurring between the model orientations with forward flow and rearward flow of coolant.

Johnson, B. V.↗

Accuracy of diagnostic heat and moisture budgets using SESAME-79 field data as revealed by observing system simulation experiments

Observing system simulation experiments are used to investigate the accuracy of diagnostic heat and moisture budgets which employ the AVE-SESAME 1979 data. The time-including, four-dimensional data set of a mesoscale model is used to simulate rawinsonde observations from AVE-SESAME 1979. The 5 C/day (heat budget) and 2 g/kg per day (moisture budget) magnitudes of error obtained indicate difficulties in the diagnosis of the heating rate in weak convective systems. The influences exerted by observational frequency, objective analysis, observational density, vertical interpolation, and observational errors on the budget are also studied, and it is found that the temporal and spatial resolution of the SESAME regional network is marginal for diagnosing convective effects on a horizontal time scale of 550 x 550 km.

Kuo, Y.-H.↗

Preferential heating of light ions during an ionospheric AR(+) injection experiment

The ARCS 4 sounding rocket was launched northward into high altitude from Poker Flat Research Range on February 23, 1990. The vehicle crossed geomagnetic field lines containing discrete auroral activity. An instrumented subpayload released 100 ev and 200 ev Ar(+) ion beams sequentially, in a direction largely perpendicular to both the local geomagnetic field and the subpayload spin axis. The instrumented main payload was separated along field lines from the beam emitting subpayload by a distance which increased at a steady rate of approx. 2.4 m/s. Three-dimensional mass spectrometric ion observations of ambient H(+) and O(+) ions, obtained onboard the main payload, are presented. Main payload electric field observations in the frequency range 0-16 kHz, are also presented. These observations are presented to demonstrate the operation of transverse ion acceleration, that was differential with respect to ion mass, primarily during 100-ev beam operations. The preferential transverse acceleration of ambient H(+) ions, as compared with ambient O(+) ions during the second, third, fourth, and fifth 100-ev beam operations, is attributed to a resonance at the injected the beam drift velocity among the thermal H(+) ions and plasma waves generated by the injected beam and propagating at the beam drift speed. This work provides experimental support of processes predicted by previously published theory and simulations.

Pollock, C. J.↗

Preferential heating of light ions during an ionospheric Ar(+) injection experiment

The Argon Release for Controlled Studies (ARCS) 4 sounding rocket was launched northward into high altitude from Poker Flat Research Range on February 23, 1990. The vehicle crossed geomagnetic field lines containing discrete auroral activity. An instrumented subpayload released 100-eV and 200-eV Ar(+) ion beams sequentially, in a direction largely perpendicular to both the local geomagnetic field and the subpayload spin axis. The instrumented main payload was separated along field lines from the beam emitting subpayload by a distance which increased at a steady rate of approximately 2.4 m/s. Three dimensional mass spectrometric ion observations of ambient H(+) and O(+) ions, obtained on board the main payload, are presented. Main payload electric field observations in the frequency range 0-16 kHz, are also presented. These observations are presented to demonstrate the operation of transverse ion acceleration, which was differential with respect to ion mass, primarily during 100-eV beam operations. The preferential transverse acceleration of ambient H(+) ions, as compared with ambient O(+) ions, during the second, third, fourth, and fifth 100-eV beam operations, is attributed to a resonance among the injected Ar(+) ions, beam-generated lower hybrid waves, and H(+) ions in the tail of the ambient thermal distribution. This work provides experimental support of processes predicted by previously published theory and simulations.

Pollock, C. J.↗

Combustion, Complex Fluids, and Fluid Physics Experiments on the ISS

From the very first days of human spaceflight, NASA has been conducting experiments in space to understand the effect of weightlessness on physical and chemically reacting systems. NASA Glenn Research Center (GRC) in Cleveland, Ohio has been at the forefront of this research looking at both fundamental studies in microgravity as well as experiments targeted at reducing the risks to long duration human missions to the moon, Mars, and beyond. In the current International Space Station (ISS) era, we now have an orbiting laboratory that provides the highly desired condition of long-duration microgravity. This allows continuous and interactive research similar to Earth-based laboratories. Because of these capabilities, the ISS is an indispensible laboratory for low gravity research. NASA GRC has been actively involved in developing and operating facilities and experiments on the ISS since the beginning of a permanent human presence on November 2, 2000. As the lead Center both Combustion, Fluid Physics, and Acceleration Measurement GRC has led the successful implementation of an Acceleration Measurement systems, the Combustion Integrated Rack (CIR), the Fluids Integrated Rack (FIR) as well as the continued use of other facilities on the ISS. These facilities have supported combustion experiments in fundamental droplet combustion fire detection fire extinguishment soot phenomena flame liftoff and stability and material flammability. The fluids experiments have studied capillary flow magneto-rheological fluids colloidal systems extensional rheology pool and nucleate boiling phenomena. In this paper, we provide an overview of the experiments conducted on the ISS over the past 12 years. We also provide a look to the future development. Experiments presented in combustion include areas such as droplet combustion, gaseous diffusion flames, solid fuels, premixed flame studies, fire safety, and super critical oxidation processes. In fluid physics, experiments are discussed in multiphase flows, capillary phenomena, and heat pipes. Finally in complex fluids, experiments in rheology and soft condensed materials will be presented.

Motil, Brian↗

Materials International Space Station Experiment - 6A and 6B

Materials on the International Space Station Experiment 6 (MISSE-6A and 6B) is a test bed for materials and coatings attached to the outside of the space station that are being evaluated for the effects of atomic oxygen, direct sunlight, radiation and extremes of heat and cold. This experiment allows the development and testing of new materials to better withstand the rigors of space environments. Results will provide a better understanding of the durability of various materials in space, leading to the design of stronger, more durable spacecraft components.

Kinard, William H.↗

Uncertainty Analysis of Coaxial Thermocouple Calorimeters Used in Arc Jets

Recent introduction of Coaxial Thermocouple type calorimeters into the NASA Ames arc jet facilities has inspired an analysis of 2D conduction effects internal to this type of calorimeter. The 1D finite slab inverse analysis (which is typically used to deduce the heat transfer to the calorimeter) relies on the assumption that lateral conduction (i.e., 2D effects) is negligible. Most calorimeter bodies have a spherical nose, which in itself is a violation of the 1D finite slab analysis assumption. Secondly most calorimeters experience a variation in heating across the face of the body which is also a violation of the 1D finite slab analysis assumption. It turns out that these two effects tend to cancel each other to some extent. This paper shows the extent to which error exists in the analysis of the Coaxial Thermocouple type calorimeters, and also offers analysis strategies for reducing the errors.

Lateral Conduction↗

Aero-Heating of Shallow Cavities in Hypersonic Freestream Flow

The purpose of these experiments and analysis was to augment the heating database and tools used for assessment of impact-induced shallow-cavity damage to the thermal protection system of the Space Shuttle Orbiter. The effect of length and depth on the local heating disturbance of rectangular cavities tested at hypersonic freestream conditions has been globally assessed using the two-color phosphor thermography method. These rapid-response experiments were conducted in the Langley 31-Inch Mach 10 Tunnel and were initiated immediately prior to the launch of STS-114, the initial flight in the Space Shuttle Return-To-Flight Program, and continued during the first week of the mission. Previously-designed and numerically-characterized blunted-nose baseline flat plates were used as the test surfaces. Three-dimensional computational predictions of the entire model geometry were used as a check on the design process and the two-dimensional flow assumptions used for the data analysis. The experimental boundary layer state conditions were inferred using the measured heating distributions on a no-cavity test article. Two test plates were developed, each containing 4 equally-spaced spanwise-distributed cavities. The first test plate contained cavities with a constant length-to-depth ratio of 8 with design point depth-to-boundary-layer-thickness ratios of 0.1, 0.2, 0.35, and 0.5. The second test plate contained cavities with a constant design point depth-to-boundary-layer-thickness ratio of 0.35 with length-to-depth ratios of 8, 12, 16, and 20. Cavity design parameters and the test condition matrix were established using the computational predictions. Preliminary results indicate that the floor-averaged Bump Factor (local heating rate nondimensionalized by upstream reference) at the tested conditions is approximately 0.3 with a standard deviation of 0.04 for laminar-in/laminar-out conditions when the cavity length-to-boundary-layer thickness is between 2.5 and 10 and for cavities in the depth-to-boundary-layer-thickness range of 0.3 to 0.8. Over this same range of conditions and parameters, preliminary results also indicate that the maximum Bump Factor on the cavity centerline falls between 2.0 and 2.75, as long as the cavity-exit conditions remain laminar. Cavities with length-to-boundary-layer-thickness ratio less than 2.5 can not be easily classified with this approach and require further analysis.

Everhart, Joel L.↗

Brazing of refractory, superalloy, and composite materials for Space Shuttle applications.

Research work concerning the metallic portion of the shuttle-orbiter heat shield (expected to experience temperatures up to 2500 F) is described. The five metals being evaluated are TD-Ni-Cr, Cb-C129Y, Cb752, Hayes 188, and Inconel 625. Brazing techniques whereby pairs of these materials are joined into thin-membered assemblies for heat shield applications are described. Results obtained with the vacuum-furnace brazing process are examined. In addition, the use of brazed aluminum-boron metal-matrix-contoured composite structures for heat shield applications is evaluated.

Beuyukian, C. S.↗

Separation and Transition on the ROTEX-T Cone-Flare

As part of NATO STO AVT-346 “Predicting Hypersonic Boundary-Layer Transition on Complex Geometries,” coordinated experimental and computational studies were conducted on the ROTEX-T, a cone-flare geometry used in a successful flight-test experiment. At the as-flown conditions, a separation bubble existed at the compression corner. Separation, reattachment, and the multifaceted linear instability paths leading this bubble to transition to turbulence are challenging to predict, but have significant impact on surface pressure and heat flux. High-resolution background-oriented schlieren and infrared thermography measurements were made in the AFOSR–Notre Dame Large Mach-6 Quiet Tunnel at freestream unit Reynolds numbers from 5.8×10(exp 6) to 12.2×10(exp 6) m-1and nominally zero angle of attack. High-speed self-aligned focusing schlieren, infrared thermography, and focused laser differential interferometry measurements were made in the AFRL Mach-6 Ludwieg Tube from 2.2×10(exp 6) to 24.7×10(exp 6) m-1and nominally zero degrees angle of attack. The surface heat-flux and Stanton number distributions were computed. Separation and reattachment locations, as well as the flow state at each, were determined from the combination of surface and off-wall measurements. The convective and global boundary-layer instabilities of the axisymmetric laminar flow at the experimental conditions were investigated computationally. Amplification of Mack’s first and second modes were observed to have logarithmic amplification factors between 5 to 7.5 at the separation location, depending on conditions. The flow was found to be globally unstable to stationary three-dimensional disturbances concentrated in the reattachment region. Previous analysis of the ROTEX-T flight data had not assessed reattachment location or the flow state upon reattachment. Thanks to the insights gained from the coordinated, on- and off-wall ground-test measurements, these evaluations have now been made. The separation location indicated by laminar simulations is consistently numerically predicted to be upstream of the experimentally observed location for a transitional separation bubble. The cause of this difference is understood to lie in the steady-state and axisymmetric assumptions made by both solvers employed to compute the basic states analyzed, as flow topology considerations assert that unsteady two-dimensional or axisymmetric separation bubbles are structurally unstable and will become three-dimensional. Computed laminar heating rates prior to separation agreed well with experiment; transitional heating rates after reattachment were between laminar and turbulent computations.

CFD Validation↗

Separation and Transition on the ROTEX-T Cone-Flare

As part of NATO STO AVT-346 “Predicting Hypersonic Boundary-Layer Transition on Complex Geometries,” coordinated experimental and computational studies were conducted on the ROTEX-T, a cone-flare geometry used in a successful flight-test experiment. At the as-flown conditions, a separation bubble existed at the compression corner. Separation, reattachment, and the multifaceted linear instability paths leading this bubble to transition to turbulence are challenging to predict, but have significant impact on surface pressure and heat flux. High-resolution background-oriented schlieren and infrared thermography measurements were made in the AFOSR–Notre Dame Large Mach-6 Quiet Tunnel at freestream unit Reynolds numbers from 5.8×10(exp 6) to 12.2×10(exp 6) m-1and nominally zero angle of attack. High-speed self-aligned focusing schlieren, infrared thermography, and focused laser differential interferometry measurements were made in the AFRL Mach-6 Ludwieg Tube from 2.2×10(exp 6) to 24.7×10(exp 6) m-1and nominally zero degrees angle of attack. The surface heat-flux and Stanton number distributions were computed. Separation and reattachment locations, as well as the flow state at each, were determined from the combination of surface and off-wall measurements. The convective and global boundary-layer instabilities of the axisymmetric laminar flow at the experimental conditions were investigated computationally. Amplification of Mack’s first and second modes were observed to have logarithmic amplification factors between 5 to 7.5 at the separation location, depending on conditions. The flow was found to be globally unstable to stationary three-dimensional disturbances concentrated in the reattachment region. Previous analysis of the ROTEX-T flight data had not assessed reattachment location or the flow state upon reattachment. Thanks to the insights gained from the coordinated, on- and off-wall ground-test measurements, these evaluations have now been made. The separation location indicated by laminar simulations is consistently numerically predicted to be upstream of the experimentally observed location for a transitional separation bubble. The cause of this difference is understood to lie in the steady-state and axisymmetric assumptions made by both solvers employed to compute the basic states analyzed, as flow topology considerations assert that unsteady two-dimensional or axisymmetric separation bubbles are structurally unstable and will become three-dimensional. Computed laminar heating rates prior to separation agreed well with experiment; transitional heating rates after reattachment were between laminar and turbulent computations.

CFD Validation↗