Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Photoluminescence of Amorphous SiO{sub 2} with Implanted Ar{sup +} Ions

Implantation of ions into amorphous silicon dioxide (a-SiO{sub 2}) is widely used in microelectronics (mainly, using Si ions) and in the production of light-guiding components of optical fibers (Ge, P, B ions). All of these elements interact with the matrix oxygen, so the point defects that occur during implantation are not only the result of the displacement of the silicon–oxygen frame atoms from their equilibrium positions, but also reflect the specific chemical interaction in the material. In this study, inert argon ions were implanted into silicon dioxide plates, which excluded chemical reactions. It is demonstrated using photoluminescence (PL) that the highest concentration of point defects in the damaged silicate network belongs to neutral oxygen vacancies (NOVs). The concentration of these and some other induced defects increased with an increase in fluence up to 5 × 10{sup 15} Ar{sup +}/cm{sup 2}, and, with a further increase in dose, the concentration dropped due to annealing of defects in the layer heated by the introduction of ions. The NOV defects appeared in the photoluminescence spectrum in the form of doublets, that is, pairs of bands belonging to the same optical transition. The appearance of doublets is explained by the dependence of the optical transition energy on the localization of identical point defects in zones of different distortions of the matrix structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Studying Near-Surface Layers of Germanium Implanted with Cobalt Ions

Results of an investigation of the surface of germanium nanostructured by means of ion implantation are presented. Single-crystalline germanium (c-Ge) plates were irradiated by 40-keV cobalt Co{sup +} ions in a dose range of (2–8) × 10{sup 16} ion/cm{sup 2}. Evolution of the germanium surface morphology with increasing ion dose was studied by method of scanning electron microscopy. It is established that an increase in the ion implantation dose is accompanied by gradual formation of a surface layer consisting of spherical particles with diameters of ~150 nm. Analysis of the X-ray diffraction patterns of samples was indicative of the appearance of nanosized cobalt germanide (CoGe) particles in the ion-implanted surface layer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of Bone Growth in Additive-Manufactured Pedicle Screw Implant by Using Ti-6Al-4V and Bioactive Glass Powder Composite

In this study, we optimized the geometry and composition of additive-manufactured pedicle screws. Metal powders of titanium-aluminum-vanadium (Ti-6Al-4V) were mixed with reactive glass-ceramic biomaterials of bioactive glass (BG) powders. To optimize the geometry of pedicle screws, we applied a novel numerical approach to proposing the optimal shape of the healing chamber to promote biological healing. We examined the geometry and composition effects of pedicle screw implants on the interfacial autologous bone attachment and bone graft incorporation through in vivo studies. The addition of an optimal amount of BG to Ti-6Al-4V leads to a lower elastic modulus of the ceramic-metal composite material, effectively reducing the stress-shielding effects. Pedicle screw implants with optimal shape design and made of the composite material of Ti-6Al-4V doped with BG fabricated through additive manufacturing exhibit greater osseointegration and a more rapid bone volume fraction during the fracture healing process 120 days after implantation, per in vivo studies.

stress-shielding effect↗

Sources and transport systems for low energy extreme of ion implantation

For the past seven years a joint research and development effort focusing on the design of steady state, intense ion sources has been in progress with the ultimate goal being to meet the two, energy extreme range needs of mega-electron-volt and 100's of electron-volt ion implanters. However, since the last Fortier is low energy ion implantation, focus of the endeavor has shifted to low energy ion implantation. For boron cluster source development, we started with molecular ions of decaborane (B{sub 10}H{sub 14}), octadecaborane (B{sub 18}H{sub 22}), and presently our focus is on carborane (C{sub 2}B{sub 10}H{sub 12}) ions developing methods for mitigating graphite deposition. Simultaneously, we are developing a pure boron ion source (without a working gas) that can form the basis for a novel, more efficient, plasma immersion source. Our Calutron-Berna ion source was converted into a universal source capable of switching between generating molecular phosphorous P{sub 4}{sup +}, high charge state ions, as well as other types of ions. Additionally, we have developed transport systems capable of transporting a very large variety of ion species, and simulations of a novel gasless/plasmaless ion beam deceleration method were also performed.

36 MATERIALS SCIENCE↗

Feasibility and Safety of Endovascular Stripping of Totally Implantable Venous Access Devices

Purpose: To evaluate the safety and feasibility of percutaneous stripping of totally implantable venous access devices (TIVAD) in case of catheter-related sleeve and to report a technique to free the catheter tip from vessel wall adherence. Materials and Methods: A total of 37 stripping procedures in 35 patients (14 men, 40%, and 21 women, 60%, mean age 53 {+-} 14 years) were reviewed. Totally implantable venous access devices were implanted because of malignancy in most cases (85.7%). Catheter-related sleeve was confirmed as cause of persistent catheter dysfunction despite instillation of thrombolytics. A technique to mobilize the catheter tip from the vessel wall was used when stripping with the snare catheter was impossible. Technical success, complication rate, and outcome were noted. Results: A total of 55.9% (n = 19) of the 34 technically successful procedures (91.9%) could be done with the snare catheter. In 15 cases (44.1%), additional maneuvers to free the TIVAD's tip from the vessel wall were needed. Success rate was not significantly lower before (72.4%) than after (96.7%) implementation of the new technique (P = 0.09). No complications were observed. Follow-up was available in 67.6% of cases. Recurrent catheter dysfunction was found in 17 TIVADs (78.3%) at a mean of 137.7 days and a median of 105 days. Conclusions: Stripping of TIVADs is technically feasible and safe, with an overall success rate of 91.9%. Additional endovascular techniques to mobilize the distal catheter tip from the wall of the superior vena cava or right atrium to allow encircling the TIVAD tip with the snare catheter may be needed in 44.1% of cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT-Guided Radioactive {sup 125}I Seed Implantation Therapy of Symptomatic Retroperitoneal Lymph Node Metastases

Purpose: This study explored the clinical efficacy of CT-guided radioactive {sup 125}I seed implantation in treating patients with symptomatic retroperitoneal lymph node metastases. Methods: Twenty-five patients with pathologically confirmed malignant tumors received CT-guided radioactive {sup 125}I seed implantation to treat metastatic lymph nodes. The diameter of the metastatic lymph nodes ranged from 1.5 to 4.5 cm. Treatment planning system (TPS) was used to reconstruct the three-dimensional image of the tumor and then calculate the corresponding quantity and distribution of {sup 125}I seeds. Results: Follow-up period for this group of patients was 2–30 months, and median time was 16 months. Symptoms of refractory pain were significantly resolved postimplantation (P < 0.05), and Karnofsky score rose dramatically (P < 0.05). Most patients reported pain relief 2–5 days after treatment. Follow-up imaging studies were performed 2 months later, which revealed CR in 7 patients, PR in 13 patients, SD in 3 patients, and PD in 2 patients. The overall effective rate (CR + PR) was 80 %. Median survival time was 25.5 months. Seven patients died of recurrent tumor; 16 patients died of multiorgan failure or other metastases. Two patients survived after 30 months follow-up. Two patients reported localized skin erythema 1 week postimplantation, which disappeared after topical treatment. Conclusions: CT-guided radioactive {sup 125}I seed implantation, which showed good palliative pain relief with acceptable short-term effects, has proved in our study to be a new, safe, effective, and relatively uncomplicated treatment option for symptomatic retroperitoneal metastatic lymph nodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TACE Combined with Implantation of Irradiation Stent Versus TACE Combine with Bare Stent for HCC Complicated by IVCTT

PurposeThis study was designed to evaluate the safety and efficacy of transarterial chemoembolization (TACE) combined with intra-IVC implantation of an irradiation stent for the treatment of hepatocellular carcinoma (HCC) complicated by inferior vena cava tumor thrombosis (IVCTT).MethodsSixty-one consecutive patients with HCC complicated by IVCTT treated by TACE combined with IVC stenting were retrospectively analysed. IVC stenting was performed using a stent loaded with {sup 125}I seeds strands (the irradiation stent) in 33 patients (Group A) and 28 patients with a bare stent (Group B). Propensity score matching eliminated the baseline differences. Overall survival, oedema related to IVC obstruction remission rate and procedure-related adverse events were compared between the two groups.ResultsThe adverse effect rate was similar for both Group A and Group B patients, and complications were adequately handled by medical treatment. TACE combined with implantation of an irradiation stent showed a significant median survival benefit over TACE combined with a bare stent, with a median survival time of 203.0 ± 28.135 days versus 93.0 ± 24.341 days (p = 0.006). The propensity score-matched (24 pairs) cohort analyses (200 ± 31.231 days vs. 66 ± 23.270 days, p = 0.019). The oedema remission rate was 97.0 % in group A patients and 96.4 % in group B, respectively. TACE-irradiation stent and object tumor response were the independent prognostic factors of favorable survival.ConclusionsTACE combined with irradiation stent implantation is a safe and effective treatment modality for patients with HCC complicated by IVCTT and may extend their survival time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Monorail Technique to Overcome Difficult Anatomical Course During Implantation of Central Venous Port via the Left Internal Jugular Vein

PurposeThe study aimed to introduce a monorail technique to overcome difficult anatomical course via left internal jugular vein in implantable port insertion.MethodsFrom 2007 to 2016, a total of 9346 patients were referred for implantable port insertion in our interventional unit, among which 79 cases were requested to insert on the left side. Our monorail technique was applied only when the technical challenge of the catheter tip entering the azygos vein instead of the superior vena cava occurred (n = 7). The technique consists of puncturing at the distal tip of the port catheter with a 21-gauge micropuncture needle and advancing a 0.018-in. hair-wire to guide and provide support for pre-assembled port.ResultsThe monorail technique was performed in seven patients and all but one case were technically successful, showing a technical success rate of 85.7%. There were no immediate or delayed complications.ConclusionsThe monorail technique is helpful to overcome the difficult anatomical course via left internal jugular vein in implantable port insertion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advancing the surgical implantation of electronic tags in fish: a gap analysis and research agenda based on a review of trends in intracoelomic tagging effects studies

Early approaches to surgical implantation of electronic tags in fish were often through trial and error, however, in recent years there has been an interest in using scientific research to identify techniques and procedures that improve the outcome of surgical procedures and determine the effects of tagging on individuals. Here we summarize the trends in 108 peer-reviewed electronic tagging effect studies focused on intracoleomic implantation to determine opportunities for future research. To date, almost all of the studies have been conducted in freshwater, typically in laboratory environments, and have focused on biotelemetry devices. The majority of studies have focused on salmonids, cyprinids, ictalurids and centrarchids, with a regional bias towards North America, Europe and Australia. Most studies have focused on determining whether there is a negative effect of tagging relative to control fish, with proportionally fewer that have contrasted different aspects of the surgical procedure (e.g., methods of sterilization, incision location, wound closure material) that could advance the discipline. Many of these studies included routine endpoints such as mortality, growth, healing and tag retention, with fewer addressing sublethal measures such as swimming ability, predator avoidance, physiological costs, or fitness. Continued research is needed to further elevate the practice of electronic tag implantation in fish in order to ensure that the data generated are relevant to untagged conspecifics (i.e., no long-term behavioural or physiological consequences) and the surgical procedure does not impair the health and welfare status of the tagged fish. To that end, we advocate for i) rigorous controlled manipulations based on statistical designs that have adequate power, account for inter-individual variation, and include controls and shams, ii) studies that transcend the laboratory and the field with more studies in marine waters, iii) incorporation of knowledge and techniques emerging from the medical and veterinary disciplines, iv) addressing all components of the surgical event, v) comparative studies that evaluate the same surgical techniques on multiple species and in different environments, vi) consideration of how biotic factors (e.g., sex, age, size) influence tagging outcomes, and vii) studies that cover a range of endpoints over ecologically-relevant time periods.

59 BASIC BIOLOGICAL SCIENCES↗

Ultrasound-Guided Transrectal Implantation of Gold Markers for Prostate Localization During External Beam Radiotherapy: Complication Rate and Risk Factors

Purpose: To report the complication rate and risk factors of transrectally implanted gold markers, used for prostate position verification and correction procedures. Methods and Materials: In 209 consecutive men with localized prostate cancer, four gold markers (1 x 7 mm) were inserted under ultrasound guidance in an outpatient setting, and the toxicity was analyzed. All patients received a questionnaire regarding complications after marker implantation. The complications and risk factors were further evaluated by reviewing the medical charts. Results: Of the 209 men, 13 (6.2%) had a moderate complication, consisting of pain and fever that resolved after treatment with oral medication. In 1.9% of the men, minor voiding complaints were observed. Other minor transient complications, defined as hematuria lasting >3 days, hematospermia, and rectal bleeding, occurred in 3.8%, 18.5%, and 9.1% of the patients, respectively. These complications were seen more often in patients with advanced tumor stage, younger age, and shorter duration of hormonal therapy. Conclusion: Transrectal gold marker implantation for high-precision prostate radiotherapy is a safe and well-tolerated procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implanted Cardiac Defibrillator Care in Radiation Oncology Patient Population

Purpose: To review the experience of a large cancer center with radiotherapy (RT) patients bearing implantable cardiac defibrillators (ICDs) to propose some preliminary care guidelines as we learn more about the devices and their interaction with the therapeutic radiation environment. Methods and Materials: We collected data on patients with implanted ICDs treated with RT during a 2.5-year period at any of the five Memorial Sloan-Kettering clinical campuses. Information regarding the model, location, and dose detected from the device, as well as the treatment fields, fraction size, and treatment energy was collected. During this time, a new management policy for these patients had been implemented requiring treatment with low-energy beams (6 MV) and close surveillance of the patients in partnership with their electrophysiologist, as they received RT. Results: During the study period, 33 patients were treated with an ICD in place. One patient experienced a default of the device to its initial factory setting that was detected by the patient hearing an auditory signal from the device. This patient had initially been treated with a 15-MV beam. After this episode, his treatment was replanned to be completed with 6-MV photons, and he experienced no further events. Conclusion: Patients with ICDs and other implanted computer-controlled devices will be encountered more frequently in the RT department, and proper management is important. We present a policy for the safe treatment of these patients in the radiation oncology environment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biological in situ Dose Painting for Image-Guided Radiation Therapy Using Drug-Loaded Implantable Devices

Purpose: Implantable devices routinely used for increasing spatial accuracy in modern image-guided radiation treatments (IGRT), such as fiducials or brachytherapy spacers, encompass the potential for in situ release of biologically active drugs, providing an opportunity to enhance the therapeutic ratio. We model this new approach for two types of treatment. Methods and Materials: Radiopaque fiducials used in IGRT, or prostate brachytherapy spacers ('eluters'), were assumed to be loaded with radiosensitizer for in situ drug slow release. An analytic function describing the concentration of radiosensitizer versus distance from eluters, depending on diffusion-elimination properties of the drug in tissue, was developed. Tumor coverage by the drug was modeled for tumors typical of lung stereotactic body radiation therapy treatments for various eluter dimensions and drug properties. Six prostate {sup 125}I brachytherapy cases were analyzed by assuming implantation of drug-loaded spacers. Radiosensitizer-induced subvolume boost was simulated from which biologically effective doses for typical radiosensitizers were calculated in one example. Results: Drug distributions from three-dimensional arrangements of drug eluters versus eluter size and drug properties were tabulated. Four radiosensitizer-loaded fiducials provide adequate radiosensitization for {approx}4-cm-diameter lung tumors, thus potentially boosting biologically equivalent doses in centrally located stereotactic body treated lesions. Similarly, multiple drug-loaded spacers provide prostate brachytherapy with flexible shaping of 'biologically equivalent doses' to fit requirements difficult to meet by using radiation alone, e.g., boosting a high-risk region juxtaposed to the urethra while respecting normal tissue tolerance of both the urethra and the rectum. Conclusions: Drug loading of implantable devices routinely used in IGRT provides new opportunities for therapy modulation via biological in situ dose painting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potentials and Limitations of Guiding Liver Stereotactic Body Radiation Therapy Set-Up on Liver-Implanted Fiducial Markers

Purpose: We investigated the potentials and limitations of guiding liver stereotactic body radiation therapy (SBRT) set-up on liver-implanted fiducial markers. Methods and Materials: Twelve patients undergoing compression-supported SBRT in a stereotactic body frame received fluoroscopy at treatment preparation and before each treatment fraction. In fluoroscopic videos we localized the markers and diaphragm tip at expiration and the spine (measurements on free-breathing and abdominal compression). Day-to-day displacements, rotations (markers only), and deformations were determined. Marker guidance was compared to conventional set-up strategies in treatment set-up simulations. Results: For compression, day-to-day motion of markers with respect to their centers of mass (COM) was {sigma} = 0.9 mm (random error SD), {Sigma} = 0.4 mm (systematic error SD), and <2.1 mm (maximum). Consequently, assuming that markers were closely surrounding spherical tumors, marker COM-guided set-up would have required safety margins of {approx}2 mm. Using marker COM as the gold standard, other set-up methods (using no correction, spine registration, and diaphragm tip craniocaudal registration) resulted in set-up errors of 1.4 mm < {sigma} < 2.8 mm, 2.6 mm < {Sigma} < 5.1 mm, and 6.3 mm < max < 12.4 mm. Day-to-day intermarker motion of <16.7%, 2.2% median, and rotations between 3.5{sup o} and 7.2{sup o} were observed. For markers not surrounding the tumor, e.g., 5 cm between respective COMs, these changes could effect residual tumor set-up errors up to 8.4 mm, 1.1 mm median (deformations), and 3.1 mm to 6.3 mm (rotations). Compression did not systematically contribute to deformations and rotations, since similar results were observed for free-breathing. Conclusions: If markers can be implanted near and around the tumor, residual set-up errors by marker guidance are small compared to those of conventional set-up methods, allowing high-precision tumor radiation set-up. However, substantial errors may result if markers are not implanted precisely, requiring further research to obtain adequate safety margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Malfunctions of Implantable Cardiac Devices in Patients Receiving Proton Beam Therapy: Incidence and Predictors

Purpose: Photon therapy has been reported to induce resets of implanted cardiac devices, but the clinical sequelae of treating patients with such devices with proton beam therapy (PBT) are not well known. We reviewed the incidence of device malfunctions among patients undergoing PBT. Methods and Materials: From March 2009 through July 2012, 42 patients with implanted cardiac implantable electronic devices (CIED; 28 pacemakers and 14 cardioverter-defibrillators) underwent 42 courses of PBT for thoracic (23, 55%), prostate (15, 36%), liver (3, 7%), or base of skull (1, 2%) tumors at a single institution. The median prescribed dose was 74 Gy (relative biological effectiveness; range 46.8-87.5 Gy), and the median distance from the treatment field to the CIED was 10 cm (range 0.8-40 cm). Maximum proton and neutron doses were estimated for each treatment course. All CIEDs were checked before radiation delivery and monitored throughout treatment. Results: Median estimated peak proton and neutron doses to the CIED in all patients were 0.8 Gy (range 0.13-21 Gy) and 346 Sv (range 11-1100 mSv). Six CIED malfunctions occurred in 5 patients (2 pacemakers and 3 defibrillators). Five of these malfunctions were CIED resets, and 1 patient with a defibrillator (in a patient with a liver tumor) had an elective replacement indicator after therapy that was not influenced by radiation. The mean distance from the proton beam to the CIED among devices that reset was 7.0 cm (range 0.9-8 cm), and the mean maximum neutron dose was 655 mSv (range 330-1100 mSv). All resets occurred in patients receiving thoracic PBT and were corrected without clinical incident. The generator for the defibrillator with the elective replacement indicator message was replaced uneventfully after treatment. Conclusions: The incidence of CIED resets was about 20% among patients receiving PBT to the thorax. We recommend that PBT be avoided in pacing-dependent patients and that patients with any type of CIED receiving thoracic PBT be followed closely.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-performance carbon nanotube-implanted mesoporous carbon spheres for supercapacitors with low series resistance

Research highlights: {yields} CNTs-implanted porous carbon spheres are prepared by using gelatin as soft template. {yields} Homogeneously distributed CNTs form a well-develop network in carbon spheres. {yields} CNTs act as a reinforcing backbone assisting the formation of pore structure. {yields} CNTs improve electrical conductivity and specific capacitance of supercapacitor. -- Abstract: Carbon nanotube-implanted mesoporous carbon spheres were prepared by an easy polymerization-induced colloid aggregation method using gelatin as a soft template. Scanning electron microscopy, transmission electron microscopy and nitrogen adsorption-desorption measurements reveal that the materials are mesoporous carbon spheres, with a diameter of {approx}0.5-1.0 {mu}m, a specific surface area of 284 m{sup 2}/g and average pore size of 3.9 nm. Using the carbon nanotube-implanted mesoporous carbon spheres as electrode material for supercapacitors in an aqueous electrolyte solution, a low equivalent series resistance of 0.83 {Omega} cm{sup 2} and a maximum specific capacitance of 189 F/g with a measured power density of 8.7 kW/kg at energy density of 6.6 Wh/kg are obtained.

36 MATERIALS SCIENCE↗

Energy dependence on formation of TiO{sub 2} nanofilms by Ti ion implantation and annealing

Graphical abstract: - Highlights: • Fabrication of TiO{sub 2} films by ion implantation and annealing strongly depends on ion energy. • Best photocatalytic activity is achieved in the TiO{sub 2} nanofilm annealed at 1000 °C. • Phase transformation of TiO{sub 2} appears under annealing temperature of 900 °C. - Abstract: TiO{sub 2} nanofilms were fabricated by a solid-phase-growth progress. The silica glass slides were implanted with Ti ions to the fluence of 1.84 × 10{sup 17} ions/cm{sup 2} at accelerate voltages of 20, 50, and 80 kV, respectively. The samples were annealed in oxygen atmosphere at 700, 800, 900, and 1000 °C for 4 h, respectively. The influence of the ion energy and the annealing temperature on the formation and phase transformation of the TiO{sub 2} films was studied. It was found that anatase TiO{sub 2} nanofilms instead of embedded rutile TiO{sub 2} nanoparticles on the substrate surfaces when the energy of implanted Ti atoms was 20 kV.

36 MATERIALS SCIENCE↗

Microstructural Effects of High Dose Helium Implantation in ErD 2

Metal hydrides can store hydrogen isotopes with high volumetric density. In metal tritides, tritium beta decay can result in accumulation of helium within the solid, in some cases exceeding 10 at.% helium after only 4 years of aging. Helium is insoluble in most materials, but often does not readily escape, and instead coalesces to form nanoscale bubbles when helium concentrations are near 1 at.%. Blistering or spallation often occurs at higher concentrations. Radioactive particles shed during this process present a potential safety hazard. This study investigates the effects of high helium concentrations on erbium deuteride (ErD 2 ), a non-radioactive surrogate material for erbium tritide (ErT 2 ). To simulate tritium decay in the surrogate, high doses of 120 keV helium ions were implanted into ErD 2 films at room temperature. Scanning and transmission electron microscopy indicated spherical helium bubble formation at a critical concentration of 1.5 at.% and bubble linkage leading to nanoscale crack formation at a concentration of 7.5 at.%. Additionally, crack propagation occurred through the nanocrack region, resulting in spallation extending from the implantation peak to the surface. Electron energy loss spectroscopy was utilized to confirm the presence of high-pressure helium in the nanocracks, suggesting that helium gas plays a predominant role in deformation. This work improves the overall understanding of helium behavior in ErD 2 by using modern characterization techniques to determine: the critical helium concentration required for bubble formation, the material failure mechanism at high concentration, and the nanoscale mechanisms responsible for material failure in helium implanted ErD 2 .

36 MATERIALS SCIENCE↗

Atomic insight into concurrent He, D, and T sputtering and near-surface implantation of 3C-SiC crystallographic surfaces

We present results from atomistic simulations of sputtering and near-surface implantation of concurrent He, D, and T bombardment of cubic silicon carbide (3C-SiC). This is achieved by first establishing a many-body interatomic potential parameter set to treat interactions of He and hydrogenic species in 3C-SiC informed by ab-initio calculations. To obtain sputtering yields we perform both classical molecular dynamics and binary collision approximation simulations for normal incident particles having energies ranging from 25 to 800 eV. We find that due to differences in species surface binding energy of various crystallographic surfaces in 3C-SiC, the sputtering yield of Si is significantly less than that of C, but sputtering yields show limited sensitivity to crystallographic surface orientation. An exception to this occurs when the terminating crystallographic surface plane is more rich in Si rather than C, resulting in comparable sputtering yields of Si and C. The influence of temperature on sputtering is explored and shows limited effect. Finally, the nature of implanted He, D, and T within 3C-SiC surfaces is investigated to understand implantation profiles and stability of defects.

36 MATERIALS SCIENCE↗