Search NASA⌕ Search

SEARCH · Search NASA

Results for “INDUCTIVE CHARGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

A TOpographic Mapping (ATOM) Method to Design Magnetic Cores

Wireless power transfer offers safe, convenient, and efficient way of charging electric vehicles. Ongoing research is targeting wireless charging pad design optimization; designing the magnetic component is the most important part of the coupler design because the magnetic part determines the coupling factor and efficiency. Optimizing the coil layout and geometry as well as ferrite design requires finite elements analysis based modeling and simulation for minimized core losses, maximized magnetic coupling, and minimized material use for cost-effectiveness. Although parametric finite element analysis or emerging artificial intelligence methods can generate very accurate results, simulation times are extremely long. To address this issue, this study proposes a simple, effective core design called A TOpographic Mapping (ATOM). The proposed design is based on the design of magnetic core by using the magnetic flux distribution. The thickness of the core increases with increasing magnetic flux density, forming a variable thickness core design with less material and minimized core losses compared to conventional designs. A superimposing method is used to create an optimal design for a rotational magnetic field-based system. According to simulation results, the ATOM design reduces the required material volume by 13.19% and yields the lowest core loss and highest mutual inductance compared to other designs. In addition, misalignment, electromagnetic interference, and thermal performance were evaluated for the proposed design.

Aydin, Emrullah [Oak Ridge National Laboratory (OR↗

Properties and etching rates of negative ions in inductively coupled plasmas and dc discharges produced in Ar/SF{sub 6}

Negative ion production is investigated in a chamber with transversal magnetic filter operated in dc or inductively coupled plasma (ICP) modes in Ar/SF{sub 6} gas mixtures. Plasma parameters are evaluated by mass spectrometry and Langmuir probe for different discharge conditions. The density ratio of negative ion to electron exceeded 300 in dc mode while it was below 100 in the ICP mode. The possibility to apply a large positive bias to an electrode without affecting the plasma potential and the transition from a negative sheath to anodic glow are also investigated. The etching rates by positive and negative ions are evaluated on silicon substrate for different Ar/SF{sub 6} gas ratios. The etching rate by negative ions was with less than 5% smaller than that by positive ions.

36 MATERIALS SCIENCE↗

Comprehensive Basis-Set Testing of Extended Symmetry-Adapted Perturbation Theory and Assessment of Mixed-Basis Combinations to Reduce Cost

Hybrid or “extended” symmetry-adapted perturbation theory (XSAPT) replaces traditional SAPT’s treatment of dispersion with better performing alternatives while at the same time extending two-body (dimer) SAPT to a many-body treatment of polarization using a self-consistent charge embedding procedure. The present work presents a systematic study of how XSAPT interaction energies and energy components converge with respect to the choice of Gaussian basis set. Errors can be reduced in a systematic way using correlation-consistent basis sets, with aug-cc-pVTZ results converged within <0.1 kcal/mol. Similar (if slightly less systematic) behavior is obtained using Karlsruhe basis sets at much lower cost, and we introduce new versions with limited augmentation that are even more efficient. Pople-style basis sets, which are more efficient still, often afford good results if a large number of polarization functions are included. The dispersion models used in XSAPT afford much faster basis-set convergence as compared to the perturbative description of dispersion in conventional SAPT, meaning that “compromise” basis sets (such as jun-cc-pVDZ) are no longer required and benchmark-quality results can be obtained using triple-ζ basis sets. The use of diffuse functions proves to be essential, especially for the description of hydrogen bonds. As a result, the “δ(Hartree–Fock)” correction for high-order induction can be performed in double-ζ basis sets without significant loss of accuracy, leading to a mixed-basis approach that offers 4× speedup over the existing (cubic scaling) XSAPT approach.

74 ATOMIC AND MOLECULAR PHYSICS↗

Influence of heat and particle fluxes nonlocality on spatial distribution of plasma density in two-chamber inductively coupled plasma sources

This study presents 2D simulations of the two-chamber inductively coupled plasma source where power is supplied in the small discharge chamber and extends by electron thermal conductivity mechanism to the big diffusion chamber. Depending on pressure, two main scenarios of plasma density and its spatial distribution behavior were identified. One case is characterized by the localization of plasma in the small driver chamber where power is deposed. Another case describes when the diffusion chamber becomes the main source of plasma with maximum of the electron density. The differences in spatial distribution are caused by local or non-local behavior of electron energy transport in the discharge volume due to different characteristic scale of heat transfer with electronic conductivity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatial learning and memory deficits induced by exposure to iron-56-particle radiation

It has previously been shown that exposing rats to particles of high energy and charge (HZE) disrupts the functioning of the dopaminergic system and behaviors mediated by this system, such as motor performance and an amphetamine-induced conditioned taste aversion; these adverse behavioral and neuronal effects are similar to those seen in aged animals. Because cognition declines with age, spatial learning and memory were assessed in the Morris water maze 1 month after whole-body irradiation with 1.5 Gy of 1 GeV/nucleon high-energy (56)Fe particles, to test the cognitive behavioral consequences of radiation exposure. Irradiated rats demonstrated cognitive impairment compared to the control group as seen in their increased latencies to find the hidden platform, particularly on the reversal day when the platform was moved to the opposite quadrant. Also, the irradiated group used nonspatial strategies during the probe trials (swim with no platform), i.e. less time spent in the platform quadrant, fewer crossings of and less time spent in the previous platform location, and longer latencies to the previous platform location. These findings are similar to those seen in aged rats, suggesting that an increased release of reactive oxygen species may be responsible for the induction of radiation- and age-related cognitive deficits. If these decrements in behavior also occur in humans, they may impair the ability of astronauts to perform critical tasks during long-term space travel beyond the magnetosphere.

NASA Program Biomedical Research and Countermeasur↗

Sympathetic cooling of the Ba{sup +} ion by collisions with ultracold Rb atoms: Theoretical prospects

State-of-the-art ab initio techniques have been applied to compute the potential energy curves of the (BaRb){sup +} molecular ion in the Born-Oppenheimer approximation for the singlet and triplet states dissociating into the ground-state {sup 1}S Rb{sup +} ion and the Ba atom in the ground {sup 1}S state or the lowest singlet or triplet d excited states, and for the singlet and triplet states dissociating into the ground-state {sup 2}S Rb atom and the ground-state {sup 2}S Ba{sup +} ion. The ground-state potential energy was obtained with the coupled-cluster method restricted to single, double, and nonperturbative triple excitations. The first triplet states in the {Sigma}, {Pi}, and {Delta} symmetries were computed with the restricted open-shell coupled-cluster method restricted to single, double, and nonperturbative triple excitations. All other excited-state potential energy curves were computed using the equation of motion approach within the coupled-cluster singles, doubles, and linear triples framework. The long-range coefficients describing the electrostatic, induction, and dispersion interactions at large interatomic distances are also reported. The electric transition dipole moments governing the x {sup 1{Sigma}{yields}1{Sigma}},{sup 1{Pi}} transitions have been obtained as the first residue of the polarization propagator computed with the linear response coupled-cluster method restricted to single and double excitations. Nonadiabatic radial and angular coupling matrix elements as well as the spin-orbit coupling matrix elements have been evaluated using the multireference configuration-interaction method restricted to single and double excitations with a large active space. With these couplings, the spin-orbit-coupled (relativistic) potential energy curves for the 0{sup +} and 1 states relevant for the running experiments have been obtained. Finally, relativistic transition moments and nonadiabatic coupling matrix elements were obtained from the nonrelativistic results and spin-orbit eigenvectors. The electronic structure input has been employed in the single-channel scattering calculations of the collisional cross sections between the Ba{sup +} ion and Rb atom. Both nonrelativistic and relativistic potentials were used in these calculations. Our results show that the inelastic cross section corresponding to the charge transfer from the Rb atom to the Ba{sup +} ion is much smaller than the elastic one over a wide range of energies up to 1 mK. This suggests that sympathetic cooling of the Ba{sup +} ion by collisions with ultracold Rb atoms should be possible.

74 ATOMIC AND MOLECULAR PHYSICS↗

Highly multiplexible thermal kinetic inductance detectors for x-ray imaging spectroscopy

For X-ray imaging spectroscopy, high spatial resolution over a large field of view is often as important as high energy resolution, but current X-ray detectors do not provide both in the same device. Thermal Kinetic Inductance Detectors (TKIDs) are being developed as they offer a feasible way to combine the energy resolution of transition edge sensors with pixel counts approaching CCDs and thus promise significant improvements for many X-ray spectroscopy applications. TKIDs are a variation of Microwave Kinetic Inductance Detectors (MKIDs) and share their multiplexibility: working MKID arrays with 2024 pixels have recently been demonstrated and much bigger arrays are under development. In this work, we present a TKID prototype, which is able to achieve an energy resolution of 75 eV at 5.9 keV, even though its general design still has to be optimized. We further describe TKID fabrication, characterization, multiplexing, and working principle and demonstrate the necessity of a data fitting algorithm in order to extract photon energies. With further design optimizations, we expect to be able to improve our TKID energy resolution to less than 10 eV at 5.9 keV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Crosslinked Polyethyleneimine Gel Polymer Interface to Improve Cycling Stability of RFBs

Redox flow batteries are considered a promising technology for grid energy storage. However, capacity decay caused by crossover of active materials is a universal challenge for many flow battery systems, which are based on various chemistries. In this paper, using the vanadium redox flow battery as an example, we demonstrate a new gel polymer interface (GPI) consisting of crosslinked polyethyleneimine with a large amount of amino and carboxylic acid groups introduced between the positive electrode and the membrane. The GPI functions as a key component to prevent vanadium ions from crossing the membrane, thus supporting stable long-term cycling. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) measurements were conducted to investigate the effect of GPI on the electrochemical properties of graphitic carbon electrodes (GCFs) and redox reaction of catholyte. X-ray photoelectron spectroscopy (XPS) and 1 H nuclear magnetic resonance (NMR) spectra demonstrated that the crosslinked GPI is chemically stable for 100 cycles without dissolution of polymers and swelling in the strong acidic electrolytes. Results from inductively coupled plasma mass spectrometry (ICP-MS), Fourier-transform infrared (FTIR) spectroscopy, and energy-dispersive X-ray (EDX) spectroscopy proved that the GPI is effective in maintaining the concentration of vanadium species in their respective half-cells, resulting in improved cycling stability because of it prevents active species from crossing the membrane and stabilizes the oxidation states of active species.

Lim, Hyung-Seok↗

DISTRIBUTION OF ION-EXCHANGEABLE RARE EARTH ELEMENTS AND CRITICAL MINERALS IN COAL-HOSTED CLAYS OF THE POWDER RIVER BASIN, WY

Increasing demand for a more robust domestic supply of rare earth elements (REE) and critical minerals (CM) has led to significant investigation into unconventional sources. Coal and coal byproducts from the Powder River Basin (PRB) of Wyoming are potential sources of REE but lack complete characterization of mineral hosts including ion-adsorption clays (IACs). IACs, which provide a substantial portion of the global REE supply, form when hydrated REE complexes are physiosorbed to negatively charged sites on clay surfaces. Typical IAC minerals include kaolinite, illite, and smectite. REE complexes are easily leached from IACs via ion exchange, making them economically attractive. However, research regarding the partitioning behaviors of strategic metals into PRB coal-hosted clays is limited. This project aims to quantify the modes of occurrence and distribution of REE and CM in clay minerals derived from PRB coals. Strategic metals investigated in this project have historic production or promising deposits within the PRB and/or high anticipated supply risk, and include: REE (lanthanides and Y), V, Ti, platinum group elements (PGE; Pt, Pd, Rh, Ru, Ir, Os), Al, Co, Ga, Zr, and W. Semi-quantitative compositional data from portable x-ray fluorescence spectroscopy (pXRF) on coal core from the PRB is consistent with the known correlation between REE and Al content, suggesting increased REE abundance will be found in clay-rich units. pXRF data also identifies elevated V, Ti, Co, and Zr correlated with Al. Preliminary x-ray diffraction (XRD) data indicates kaolinite, illite, and dickite are abundant minerals in overburden and clay-rich partings. Quantitative analysis via inductively coupled plasma mass spectrometry (ICP-MS) provides insights into REE and CM fractionation in coals as we compare trace metal occurrence to variations in mineralogy. Additionally, we apply scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS) data to correlate clay size and morphology to trace metal occurrence. Our findings supplement a broader effort to couple REE and CM extraction with existing domestic coal production and contribute to the fundamental understanding of adsorption processes that occur in low-temperature basin environments.

Stuart, Sophia↗

TU-EF-BRA-03: Free Induction Decay (without the Decay) and Spin-Echo Imaging

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

Plasma production by means of discharge in a spherical cavity

The work is devoted to the study of plasma, appearing as a result of cumulation of shock wave with form close to spherical. The shock wave was obtained by triggering of fast discharge (dI/dt about 10{sup 12} A/s) on inner surface of cavity, made from insulator. Spherical cavity with radius 4.5 mm was filled with Ar at 80 Pa. Inductive storage with semiconductive opening switch was used as a current driver. Spherical plasma with diameter about 1 mm, emitting in vacuum ultraviolet (vuv), was detected by means of pinhole measurements with time gated microchannel plate camera, starting about 50 ns from the beginning of the discharge. vuv spectra have shown the presence spectral lines of ArV-ArVIII ions, which gives the estimation of electron temperature as 30 eV. The plasma ball reveals no instabilities, keeps its characteristics and emits vuv radiation during 300 ns. After 600 ns from the beginning of the discharge plasma emits a flux of electrons with energies about 1 keV with temporal structure about 100 ns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ruthenium/Carbon Nanocomposites for Efficient Hydrogen Electrocatalysis: Impacts of Halide Residues

Ruthenium has emerged as a promising substitute for platinum toward the hydrogen evolution/oxidation reaction (HER/HOR). Herein, ruthenium/carbon composites are prepared by magnetic induction heating (300 A, 10 s) of RuCl3, RuBr3 or RuI3 loaded on hollow N-doped carbon cages (HNC). The HNC-RuCl3-300A sample consists of Ru nanoparticles (dia. 1.96 nm) and abundant Cl residues. HNC-RuBr3-300A possesses a larger nanoparticle size (≈19.36 nm) and lower content of Br residues. HNC-RuI3-300A contains only bulk-like Ru agglomerates with a minimal amount of I residues, due to reduced Ru-halide bonding interactions. Among these, HNC-RuCl3-300A exhibits the best HER activity in alkaline media, with a low overpotential of only -26 mV to reach 10 mA cm-2, even outperforming Pt/C, and can be used as the cathode catalyst for anion exchange membrane water electrolyzer (along with commercial RuO2 as the anode catalyst), producing 0.5 A cm- 2 at 1.88 V for up to 100 h, a performance markedly better than that with Pt/C. HNC-RuCl3-300A also exhibits the best HOR activity, with a half-wave potential (+18 mV) even lower than that of Pt/C (+35 mV). These activities are ascribed to the combined contributions of small Ru nanoparticles and Ru-to-halide charge transfer that weaken H adsorption.

Yu, Bingzhe↗

Challenges of future high power wireless power transfer for light-duty electric vehicles----technology and risk management

Wireless power transfer is a state-of-the-art technology with the advantage of convenience and flexibility, as well as the capability of enabling fully automated charging. With power transfer levels increasing beyond 100 kW, many technical and risk management challenges emerge. Here, instead of focusing on the progress review of wireless power transfer technology, this paper discusses the future challenges and risks for high power wireless charging for light-duty electric vehicles. Aiming at 200 kW or higher wireless power transfer, we discuss technology and risk management challenges in the area of electromagnetic safety, resonant frequency determination, and cybersecurity risks in detail. As potential solutions to overcome these challenges, the latest technologies with an emphasis on advanced shielding solutions and recent progress on SiC converters from both industrial and academic institutions are reviewed, and some perspectives and propositions are provided.

25 ENERGY STORAGE↗

Recurrent convolutional neural networks for modeling nonadiabatic dynamics of quantum-classical systems

Recurrent neural networks (RNNs) have recently been extensively applied to model the time evolution in fluid dynamics, weather predictions, and even chaotic systems due to their ability to capture temporal dependencies and sequential patterns in data. Here we present an RNN model based on convolutional neural networks for modeling the nonlinear nonadiabatic dynamics of hybrid quantum-classical systems. The dynamical evolution of the hybrid systems is governed by equations of motion for classical degrees of freedom and von Neumann equation for electrons. The Physics-Aware Recurrent Convolution (PARC) neural network structure incorporates a differentiator-integrator architecture that inductively models the spatiotemporal dynamics of generic physical systems. Here, we apply our RNN approach to learn the space-time evolution of a one-dimensional semiclassical Holstein model after an interaction quench. For shallow quenches (small changes in electron-lattice coupling), the deterministic dynamics can be accurately captured using a single-CNN-based recurrent network. In contrast, deep quenches induce chaotic evolution, making long-term trajectory prediction significantly more challenging. Nonetheless, we demonstrate that the PARC-CNN architecture can effectively learn the statistical climate of the Holstein model under deep-quench conditions.

Holstein model↗

Stability of High Power Beam Injection in Negative-Ion-Based LHD-NBI

We describe the characteristic of stable beam injection in a neutral beam injector (NBI) for Large Helical Device (LHD) in high injection power of more than 6 MW. In the NBI, it takes a week after starting Cs seeding to finish the pre-injection conditioning. The injection starts with the beam power {approx}6.2 MW, and the maximum power reaches {approx}7 MW. The Cs-seeding rate affects the beam stability in such high power injections. By optimizing the rate to 0.65 mg/shot, the success ratio, which is defined as a ratio of actual pulse duration to setting one, increases to 85-90% in the power and energy range of more than 6.2 MW and 185 keV, respectively. The weights of Cs adsorbed on several surfaces in the ion sources of the NBI are measured by means of Inductively-Coupled Plasma Atomic Emission Spectroscopy (ICP-AES), and averaged surface densities are calculated by dividing with the several surface areas. The seeded Cs of 99.5% is condensed in the plasma generator, and very tiny amount of Cs reaches the surfaces of the accelerator grids. This very low amount of Cs on the grids is interpreted that most of the Cs atom evaporated from the inner walls is ionized during the arc discharges, and repelled to the source plasmas by the electrostatic field for H- extraction.

43 PARTICLE ACCELERATORS↗

Electronic coupling through natural amino acids

Myriad scientific domains concern themselves with biological electron transfer (ET) events that span across vast scales of rate and efficiency through a remarkably fine-tuned integration of amino acid (AA) sequences, electronic structure, dynamics, and environment interactions. Within this intricate scheme, many questions persist as to how proteins modulate electron-tunneling properties. To help elucidate these principles, we develop a model set of peptides representing the common α-helix and β-strand motifs including all natural AAs within implicit protein-environment solvation. Using an effective Hamiltonian strategy with density functional theory, we characterize the electronic coupling through these peptides, furthermore considering side-chain dynamics. For both motifs, predictions consistently show that backbone-mediated electronic coupling is distinctly sensitive to AA type (aliphatic, polar, aromatic, negatively charged and positively charged), and to side-chain orientation. The unique properties of these residues may be employed to design activated, deactivated, or switch-like superexchange pathways. Electronic structure calculations and Green’s function analyses indicate that localized shifts in the electron density along the peptide play a role in modulating these pathways, and further substantiate the experimentally observed behavior of proline residues as superbridges. The distinct sensitivities of tunneling pathways to sequence and conformation revealed in this electronic coupling database help improve our fundamental understanding of the broad diversity of ET reactivity and provide guiding principles for peptide design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of low-temperature silicon nitride films produced by inductively coupled plasma chemical vapor deposition

Silicon nitride films were synthesized at 170 deg. C by using inductively coupled plasma chemical vapor deposition under three microwave power conditions of 500, 800, and 1000 W. The chemical, physical and electrical properties of the deposited silicon nitride films were characterized by Fourier transform infrared, wet etching, atomic force microscopy, ellipsometry, J-V, and C-V measurements of metal-insulator-semiconductor. The microwave power for film deposition is found to play an important role at the films' properties. A high microwave power reduces the retention of hydrogen in a form of Si-H and N-H atomic bonds. The microwave power significantly affects the density of pin holes; the 800 W film has the lowest density of pin holes. In general, the low-temperature silicon nitride films possess better surface roughness than the conventional silicon nitride films produced at higher temperatures. The low-temperature silicon nitride films exhibit an abrupt breakdown, a characteristic of avalanche breakdown. The variation in breakdown strength is correlated with the change in pin-hole density, and the 800 W silicon nitride film possesses the highest breakdown strength. The microwave power has limited influences on leakage current and resistivity of the films. All the low-temperature silicon nitride films are characterized by high-density fixed charges and interface charge traps, of which both densities vary slightly with the microwave power for film deposition.

36 MATERIALS SCIENCE↗

Design and Testing of a Small Inductive Pulsed Plasma Thruster

The design and testing of a small inductive pulsed plasma thruster (IPPT), shown in Fig. 1 with all the major subsystems required for a thruster of this kind are described. Thrust measurements and imaging of the device operated in rep-rated mode are presented to quantify the performance envelope of the device. The small IPPT described in this paper was designed to serve as a test-bed for the pulsed gas-valves and solid-state switches required for a IPPTs. A modular design approach was used to permit future modifications and upgrades. The thruster consists of the following sub-systems: a) a multi-turn, spiral-wound acceleration coil (27 cm o.d., 10 cm i.d.) driven by a 10 microFarad capacitor and switched with a high-voltage thyristor, b) a fast pulsed gas-valve, and c.) a glow-discharge pre-ionizer (PI) circuit. The acceleration-coil circuit may be operated at voltages up to 4 kV (the thyristor limit is 4.5 kV). The device may be operated at rep-rates up to 30 Hz with the present gas-valve. Thrust measurements and imaging of the device operated in rep-rated mode will be presented. The pre-ionizer consists of a 0.3 microFarad capacitor charged to 4 kV and connected to two annular stainless-steel electrodes bounding the area of the coil-face. The 4 kV potential is held across them and when the gas is puffed in over the coil, the PI circuit is completed, and a plasma is formed. Even at the less than optimal base-pressure in the chamber (approximately 5 × 10(exp −4) torr), the PI held-off the applied voltage, and only discharged upon command. For a capacitor charge of 2 kV the peak coil current is 4.1 kA, and during this pulse a very bright discharge (much brighter than from the PI alone) was observed (see Fig. 2). Interestingly, for discharges at this charge voltage the PI was not required as the current rise rate, dI/dt, of the coil itself was sufficient to ionize the gas.

Martin, Adam K.↗