Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Unpacking the drivers of diurnal dynamics of sun-induced chlorophyll fluorescence (SIF): Canopy structure, plant physiology, instrument configuration and retrieval methods

Sun-induced chlorophyll fluorescence (SIF) from spaceborne sensors is a promising tool for global carbon cycle monitoring, but its application is constrained by insufficient understanding of the drivers underlying diurnal SIF dynamics. SIF measurements from ground-based towers can reveal diurnal SIF dynamics across biomes and environmental conditions; however, meaningful interpretation of diurnal variations requires disentangling impacts from canopy structure, plant physiology, instrument configuration and retrieval methods, which often interact with and confound each other. This study aims to unpack these drivers using 1) concurrent ground and airborne canopy-scale and leaf-scale measurements at a corn field, 2) a mechanistic SIF model that explicitly considers the dynamics of photochemistry (via the fraction of open photosystem II reaction centers, qL) and photoprotection (via nonphotochemical quenching, NPQ) as well as their interactive dependence on the sub-canopy light environment, and 3) cross-comparison of SIF instrument configurations and retrieval methods. We found that crop row orientations and sun angles can introduce a distinctive midday dip in SIF in absence of stress, due to a midday drop of absorbed photosynthetically active radiation (APAR) when crop rows are north-south oriented. Canopy structure caused distinctive responses in both qL and NPQ at different positions within the vertical canopy that collectively influenced fluorescence quantum yield (Φ F ) at the leaf scale. Once integrated at the canopy scale, diurnal dynamics of both APAR and canopy escape probability (ε) are critical for accurately shaping diurnal SIF variations. While leaf-level qL and NPQ exhibited strong diurnal dynamics, their influence was attenuated at the canopy scale due to opposing effects on SIF at different canopy layers. Furthermore, different system configurations (i.e., bi-hemispherical vs. hemispherical-conical) and retrieval methods can bias the SIF magnitude and distort its diurnal shapes, therefore confounding the interpretation of inherent strength and dynamics of SIF emission. Our findings demonstrate the importance of crop row structures, interactive variations in canopy structure and plant physiology, instrument configuration, and retrieval method in shaping the measured dynamics of diurnal SIF. This study highlights the necessity to account for these factors to accurately interpret satellite SIF, and informs future synthesis work with different SIF instrumentation and retrieval methods across sites.

59 BASIC BIOLOGICAL SCIENCES↗

The design and application of an in-laboratory diffraction-enhanced x-ray imaging instrument

We describe the design and application of a new in-laboratory diffraction-enhanced x-ray imaging (DEXI) instrument that uses a nonsynchrotron, conventional x-ray source to image the internal structure of an object. In the work presented here, a human cadaveric thumb is used as a test-sample to demonstrate the imaging capability of our instrument. A 22 keV monochromatic x-ray beam is prepared using a mismatched, two-crystal monochromator; a silicon analyzer crystal is placed in a parallel crystal geometry with the monochromator allowing both diffraction-enhanced imaging and multiple-imaging radiography to be performed. The DEXI instrument was found to have an experimentally determined spatial resolution of 160{+-}7 {mu}m in the horizontal direction and 153{+-}7 {mu}m in the vertical direction. As applied to biomedical imaging, the DEXI instrument can detect soft tissues, such as tendons and other connective tissues, that are normally difficult or impossible to image via conventional x-ray techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fundamentals of Materials, Techniques, and Instrumentation for OSL and FNTD Dosimetry

The optically stimulated luminescence (OSL) technique has already become a successful commercial tool in personal radiation dosimetry, medical dosimetry, diagnostic imaging, geological and archeological dating. This review briefly describes the history and fundamental principles of OSL materials, methods and instrumentation. The advantages of OSL technology and instrumentation in comparison with thermoluminescent technique are analyzed. Progress in material and detector engineering has allowed new and promising developments regarding OSL applications in the medical field. Special attention is dedicated to Al{sub 2}O{sub 3}:C as a material of choice for many dosimetric applications. Different aspects of OSL theory, materials optical and dosimetric properties, instrumentation, and data processing algorithms are described. The next technological breakthrough was done with Fluorescent Nuclear Track Detectors (FNTD) that have some important advantages in measuring fast neutron and high energy heavy charge particles that have become the latest tool in radiation therapy. New Mg-doped aluminum oxide crystals and novel type of imaging instrumentation for FNTD technology are discussed with regard to application in mixed neutron-gamma fields, medical dosimetry and radiobiological research.

61 RADIATION PROTECTION AND DOSIMETRY↗

Design and performance of a combined secondary ion mass spectrometry-scanning probe microscopy instrument for high sensitivity and high-resolution elemental three-dimensional analysis

State-of-the-art secondary ion mass spectrometry (SIMS) instruments allow producing 3D chemical mappings with excellent sensitivity and spatial resolution. Several important artifacts however arise from the fact that SIMS 3D mapping does not take into account the surface topography of the sample. In order to correct these artifacts, we have integrated a specially developed scanning probe microscopy (SPM) system into a commercial Cameca NanoSIMS 50 instrument. This new SPM module, which was designed as a DN200CF flange-mounted bolt-on accessory, includes a new high-precision sample stage, a scanner with a range of 100 {mu}m in x and y direction, and a dedicated SPM head which can be operated in the atomic force microscopy (AFM) and Kelvin probe force microscopy modes. Topographical information gained from AFM measurements taken before, during, and after SIMS analysis as well as the SIMS data are automatically compiled into an accurate 3D reconstruction using the software program 'SARINA,' which was developed for this first combined SIMS-SPM instrument. The achievable lateral resolutions are 6 nm in the SPM mode and 45 nm in the SIMS mode. Elemental 3D images obtained with our integrated SIMS-SPM instrument on Al/Cu and polystyrene/poly(methyl methacrylate) samples demonstrate the advantages of the combined SIMS-SPM approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Invited Article: An integrated mid-infrared, far-infrared, and terahertz optical Hall effect instrument

We report on the development of the first integrated mid-infrared, far-infrared, and terahertz optical Hall effect instrument, covering an ultra wide spectral range from 3 cm{sup −1} to 7000 cm{sup −1} (0.1–210 THz or 0.4–870 meV). The instrument comprises four sub-systems, where the magneto-cryostat-transfer sub-system enables the usage of the magneto-cryostat sub-system with the mid-infrared ellipsometer sub-system, and the far-infrared/terahertz ellipsometer sub-system. Both ellipsometer sub-systems can be used as variable angle-of-incidence spectroscopic ellipsometers in reflection or transmission mode, and are equipped with multiple light sources and detectors. The ellipsometer sub-systems are operated in polarizer-sample-rotating-analyzer configuration granting access to the upper left 3 × 3 block of the normalized 4 × 4 Mueller matrix. The closed cycle magneto-cryostat sub-system provides sample temperatures between room temperature and 1.4 K and magnetic fields up to 8 T, enabling the detection of transverse and longitudinal magnetic field-induced birefringence. We discuss theoretical background and practical realization of the integrated mid-infrared, far-infrared, and terahertz optical Hall effect instrument, as well as acquisition of optical Hall effect data and the corresponding model analysis procedures. Exemplarily, epitaxial graphene grown on 6H-SiC, a tellurium doped bulk GaAs sample and an AlGaN/GaN high electron mobility transistor structure are investigated. The selected experimental datasets display the full spectral, magnetic field and temperature range of the instrument and demonstrate data analysis strategies. Effects from free charge carriers in two dimensional confinement and in a volume material, as well as quantum mechanical effects (inter-Landau-level transitions) are observed and discussed exemplarily.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of intelligent instruments with embedded HTTP servers for control and data acquisition in a cryogenic setup—The hardware, firmware, and software implementation

The power of Ethernet for control and automation technology is being largely understood by the automation industry in recent times. Ethernet with HTTP (Hypertext Transfer Protocol) is one of the most widely accepted communication standards today. Ethernet is best known for being able to control through internet from anywhere in the globe. The Ethernet interface with built-in on-chip embedded servers ensures global connections for crate-less model of control and data acquisition systems which have several advantages over traditional crate-based control architectures for slow applications. This architecture will completely eliminate the use of any extra PLC (Programmable Logic Controller) or similar control hardware in any automation network as the control functions are firmware coded inside intelligent meters itself. Here, we describe the indigenously built project of a cryogenic control system built for linear accelerator at Inter University Accelerator Centre, known as “CADS,” which stands for “Complete Automation of Distribution System.” CADS deals with complete hardware, firmware, and software implementation of the automated linac cryogenic distribution system using many Ethernet based embedded cryogenic instruments developed in-house. Each instrument works as an intelligent meter called device-server which has the control functions and control loops built inside the firmware itself. Dedicated meters with built-in servers were designed out of ARM (Acorn RISC (Reduced Instruction Set Computer) Machine) and ATMEL processors and COTS (Commercially Off-the-Shelf) SMD (Surface Mount Devices) components, with analog sensor front-end and a digital back-end web server implementing remote procedure call over HTTP for digital control and readout functions. At present, 24 instruments which run 58 embedded servers inside, each specific to a particular type of sensor-actuator combination for closed loop operations, are now deployed and distributed across control LAN (Local Area Network). A group of six categories of such instruments have been identified for all cryogenic applications required for linac operation which were designed to build this medium-scale cryogenic automation setup. These devices have special features like remote rebooters, daughter boards for PIDs (Proportional Integral Derivative), etc., to operate them remotely in radiation areas and also have emergency switches by which each device can be taken to emergency mode temporarily. Finally, all the data are monitored, logged, controlled, and analyzed online at a central control room which has a user-friendly control interface developed using LabVIEW{sup ®}. This paper discusses the overall hardware, firmware, software design, and implementation for the cryogenics setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bootstrap estimation of the effect of instrument response function uncertainty on the reconstruction of fusion neutron sources

Neutron imagers are important diagnostics for the inertial confinement fusion implosions at the National Ignition Facility. They provide two- and three-dimensional reconstructions of the neutron source shape that are key indicators of the overall performance. To interpret the shape results properly, it is critical to estimate the uncertainty in those reconstructions. There are two main sources of uncertainties: limited neutron statistics, leading to random errors in the reconstructed images, and incomplete knowledge of the instrument response function (the pinhole-dependent point spread function). While the statistical errors dominate the uncertainty for lower yield deuterium-tritium (DT) shots, errors due to the instrument response function dominate the uncertainty for DT yields on the order of 10 16 neutrons or higher. In this work, a bootstrapping method estimates the uncertainty in a reconstructed image due to the incomplete knowledge of the instrument response function. The main reconstruction is created from the fixed collection of pinhole images that are best aligned with the neutron source. Additional reconstructions are then built using subsets of that collection of images. Variations in the shapes of these additional reconstructions originate solely from uncertainties in the instrument response function, allowing us to use them to provide an additional systematic uncertainty estimate.

47 OTHER INSTRUMENTATION↗

Electron pulse-dilation diagnostic instruments

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5–30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. In this paper we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

47 OTHER INSTRUMENTATION↗

The Complex, Unique, and Powerful Imaging Instrument for Dynamics (CUPI 2 D) at the Spallation Neutron Source (invited)

The Oak Ridge National Laboratory is planning to build the Second Target Station (STS) at the Spallation Neutron Source (SNS). STS will host a suite of novel instruments that complement the First Target Station’s beamline capabilities by offering an increased flux for cold neutrons and a broader wavelength bandwidth. A novel neutron imaging beamline, named the Complex, Unique, and Powerful Imaging Instrument for Dynamics (CUPI 2 D), is among the first eight instruments that will be commissioned at STS as part of the construction project. CUPI 2 D is designed for a broad range of neutron imaging scientific applications, such as energy storage and conversion (batteries and fuel cells), materials science and engineering (additive manufacturing, superalloys, and archaeometry), nuclear materials (novel cladding materials, nuclear fuel, and moderators), cementitious materials, biology/medical/dental applications (regenerative medicine and cancer), and life sciences (plant–soil interactions and nutrient dynamics). The innovation of this instrument lies in the utilization of a high flux of wavelength-separated cold neutrons to perform real time in situ neutron grating interferometry and Bragg edge imaging—with a wavelength resolution of δλ/λ ≈ 0.3%—simultaneously when required, across a broad range of length and time scales. This manuscript briefly describes the science enabled at CUPI 2 D based on its unique capabilities. The preliminary beamline performance, a design concept, and future development requirements are also presented.

47 OTHER INSTRUMENTATION↗

The suite of small-angle neutron scattering instruments at Oak Ridge National Laboratory

Oak Ridge National Laboratory is home to the High Flux Isotope Reactor (HFIR), a high-flux research reactor, and the Spallation Neutron Source (SNS), the world's most intense source of pulsed neutron beams. The unique co-localization of these two sources provided an opportunity to develop a suite of complementary small-angle neutron scattering instruments for studies of large-scale structures: the GP-SANS and Bio-SANS instruments at the HFIR and the EQ-SANS and TOF-USANS instruments at the SNS. This article provides an overview of the capabilities of the suite of instruments, with specific emphasis on how they complement each other. As a result, a description of the plans for future developments including greater integration of the suite into a single point of entry for neutron scattering studies of large-scale structures is also provided.

47 OTHER INSTRUMENTATION↗

Implementation of an ultrasonic instrument for simultaneous mixture and flow analysis of binary gas systems

Precision ultrasonic measurements in binary gas systems provide continuous real-time monitoring of mixture composition and flow. Using custom micro-controller-based electronics, we have developed an ultrasonic instrument, with numerous potential applications, capable of making continuous high-precision sound velocity measurements. The instrument measures sound transit times along two opposite directions aligned parallel to - or obliquely crossing - the gas flow. The difference between the two measured times yields the gas flow rate while their average gives the sound velocity, which can be compared with a sound velocity vs. molar composition look-up table for the binary mixture at a given temperature and pressure. The look-up table may be generated from prior measurements in known mixtures of the two components, from theoretical calculations, or from a combination of the two. We describe the instrument and its performance within numerous applications in the ATLAS experiment at the CERN Large Hadron Collider (LHC). The instrument can be of interest in other areas where continuous in-situ binary gas analysis and flowmetry are required. (authors)

43 PARTICLE ACCELERATORS↗

Algorithm-Driven Advances for Scientific CT Instruments: From model-based to deep learning-based approaches

Multiscale 3D characterization is widely used by materials scientists to further their understanding of the relationships between microscopic structure and macroscopic function. Scientific computed tomography (SCT) instruments are one of the most popular choices for 3D nondestructive characterization of materials at length scales ranging from the angstrom scale to the micron scale. These instruments typically have a source of radiation (such as electrons, X-rays, or neutrons) that interacts with the sample to be studied and a detector assembly to capture the result of this interaction (see Figure 1 ). A collection of such high-resolution measurements is made by reorienting the sample, which is mounted on a specially designed stage/holder after which reconstruction algorithms are used to produce the final 3D volume of interest. The specific choice of which instrument to use depends on the desired resolution and properties of the materials being imaged. Additionally, the end goal of SCT scans includes determining the morphology, chemical composition, or dynamic behavior of materials when subjected to external stimuli. In summary, SCT instruments are powerful tools that enable 3D characterization across multiple length scales and play a critical role in furthering the understanding of the structure–function relationships of different materials.

42 ENGINEERING↗

1st Advanced Marine Renewable Energy Instrumentation Experts Workshop: April 5-7, 2011

The U.S. marine energy industry is actively pursuing development of offshore wind and marine hydrokinetic (MHK) energy systems. Experience in the wind energy sector demonstrates that new technology development requires thorough measurement and characterization of the environmental conditions prevalent at installation sites and of technology operating in the field. Presently, there are no turn-keyinstrumentation system solutions that meet the measurement needs of the marine energy industry. The 1st Advanced Marine Renewable Energy Instrumentation Experts Workshop brought together technical experts from government laboratories, academia, and industry representatives from marine energy, wind, offshore oil and gas, and instrumentation developers to present and discuss the instrumentationneeds of the marine energy industry. The goals of the meeting were to: 1. Share the latest relevant knowledge among technical experts; 2. Review relevant state-of-the-art field measurement technologies and methods; 3. Review lessons learned from recent field deployments; 4. Identify synergies across different industries; 5. Identify gaps between existing and needed instrumentation capabilities;6. Understand who are the leading experts; 7. Provide a forum where stakeholders from the marine energy industry could provide substantive input in the development of new marine energy field deployable instrumentation packages.

13 HYDRO ENERGY↗

Radiation Protection Instrument Reliability and Maintainability Data

This report is a collection of reliability and maintenance data on several types of radiation protection instrumentation. Some radiation detectors are used for personnel safety; others are used for environmental stewardship. Six types of instruments are addressed in this report. These are: continuous air monitors, tritium room air monitors, facility vent stack monitors, tritium bubbler monitors, tritium in effluent water monitors, and general purpose radiation survey meters. Literature searches, operating experience data, and occurrence reports were used to identify failure modes and to estimate quantitative failure rates for several general types of radiation protection instruments. Likewise, data on instrument repair has been found when possible and used to estimate the mean time to repair. These data can be useful for facility safety assessment, personnel safety assessment, environment assessment, and for equipment and labor planning purposes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nephelometer Instrument Handbook

The Integrating Nephelometer (Figure 1) is an instrument that measures aerosol light scattering. It measures aerosol optical scattering properties by detecting (with a wide angular integration – from 7 to 170°) the light scattered by the aerosol and subtracting the light scattered by the carrier gas, the instrument walls and the background noise in the detector (zeroing). Zeroing is typically performed for 5 minutes every day at midnight UTC. The scattered light is split into red (700 nm), green (550 nm), and blue (450 nm) wavelengths and captured by three photomultiplier tubes. The instrument can measure total scatter as well as backscatter only (from 90 to 170°) (Heintzenberg and Charlson 1996; Anderson et al. 1996; Anderson and Ogren 1998; TSI 3563 2015) At ARM (Atmospheric Radiation Measurement), two identical Nephelometers are usually run in series with a sample relative humidity (RH) conditioner between them. This is possible because Nephelometer sampling is non-destructive and the sample can be passed on to another instrument. The sample RH conditioner scans through multiple RH values in cycles, treating the sample. This kind of setup allows to study how aerosol particles’ light scattering properties are affected by humidification (Anderson et al. 1996). For historical reasons, the two Nephelometers in this setup are labeled “wet” and “dry”, with the “dry” Nephelometer usually being the one before the conditioner and sampling ambient air (the names are switched for the MAOS measurement site due to the high RH of the ambient air).

47 OTHER INSTRUMENTATION↗

Cryogenic Frostpoint Hygrometer (CFH) Instrument Handbook

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Cryogenic Frostpoint Hygrometer (CFH) is a small, balloon-borne instrument that provides highly accurate measurements of water vapor in the atmosphere. The CFH, although highly modified, is based upon the National Oceanic and Atmospheric Administration (NOAA)/Climate Monitoring and Diagnostic Laboratory (CMDL) frostpoint hygrometer (FPH) that has been flown in Boulder, Colorado, since 1980. The CFH has a significantly greater sensitivity to water vapor than standard radiosondes, as it can measure the frostpoint or dewpoint temperatures at an accuracy better than 0.2 K corresponding to water volume mixing ratios accuracies of only a few parts per million. The main instrument part is a small mirror, which is cooled by a cryogen in order to be covered with a thin layer of water vapor condensate. A pair of photodiodes detects the condensation on the temperature-controlled mirror. The phase of the condensate is controlled by a force-freezing algorithm, allowing for clear interpretation of the dew point versus frostpoint. The replacement of analog electronics with a microprocessor, a feedback controller, and thermistor calibration have led to improved accuracy and performance of the CFH over its predecessors. Further characteristics like reduced power consumption and low instrument weight made the CFH a successful instrument to perform in situ balloon-borne measurements of water vapor in the upper troposphere and lower stratosphere. CFH measurements are now used worldwide to validate radiosonde, satellite, and ground-based profiler measurements.

47 OTHER INSTRUMENTATION↗

In-Pile Instrumentation Initiative: A Multidisciplinary Scientific Approach for Characterization of Fuels and Materials

The In-Pile Instrumentation Initiative (I3) will conduct research needed to develop and deploy unique instruments to characterize the behavior of fuels and materials during irradiation tests conducted by Nuclear Energy (NE) programs within the Department of Energy. (Vision) I3 will provide real-time, accurate, spatially resolved information regarding performance of fuels and materials that can be directly tied to microstructure. This vision is reflected in the research direction of several NE programs that have identified a need to correlate material performance with evolving microstructure. Currently, these relationships can only be inferred through examination of materials in a post-irradiation environment. Realization of this vision will involve a sharp departure from the current approach that prioritizes instrument reliability over delivering optimal measurement capabilities. To realize this vision will require technical breakthroughs in several key areas, including materials science, modeling and simulation, advanced manufacturing, and instrument development. Insights gained from this initiative will be critical for advancing a number of NE objectives. Examples include expediting the development of accident-tolerant fuels, providing a deep understanding of materials suitable for the extreme environments associated with new reactor technologies, and providing unparalleled validation metrics for new science-based fuel performance codes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparative Assessment of Experimental Testing of Instrument with an Embedded Digital Device Using Model-Based and Conventional Methods

The use of digital equipment has not been widespread in U.S. nuclear facilities. A major contributing factor to this situation arises from regulatory concerns about common cause failures (CCFs) stemming from the use of identical software in redundant systems, questions as to how to quantify the reliability of software-based products, validity of tools that are used for software verification and validation (V&V), and the effectiveness of software QA procedures. Compounding the concerns are sporadic incidents of digital equipment malfunctions in nuclear power plants, including lockups resulting from software memory leaks, feedwater control malfunctions due to excessive traffic on Ethernet networks, software logic errors, and other problems leading to plant trips. Additionally, the limited amount of demonstrated research and a lack of industry consensus on quantitative software reliability methodologies has hindered the widespread adoption of digital I&C in the nuclear industry. In a recent Regulatory Issue Summary (RIS), the U.S. Nuclear Regulatory Commission (NRC) identified concerns about the impact of greater use of instrumentation and control (I&C) equipment with an embedded digital device (EDD) [1]. Specifically, the NRC staff states that increased use of such devices “may increase a facility’s vulnerability to a CCF” (i.e., common-cause failure). The prevailing NRC guidance regarding software CCF (SCCF) identifies two design attributes that are acceptable for eliminating CCF concerns: (1) diversity or (2) testability (specifically, 100% testability). Either solution can result in high costs and remaining licensing uncertainty (i.e., how much diversity is enough? how to ensure test coverage of every possible sequence of device states?). Consequently, many utilities and reactor designers have limited or avoided more extensive use of digital technology to minimize licensing, scheduling, and financial risk. Without development of cost effective qualification methods to satisfy regulatory requirements and address the potential for CCF vulnerability associated with EDDs, the nuclear power industry may not be able to realize the benefits of digital technology achieved by other industries. In order to address these challenges, the U.S. Department of Energy (DOE) is sponsoring this research to assess the prospect of CCF in digital I&C equipment. The purpose of the current research is to develop an effective approach employing science-based methods to resolve concerns about CCF vulnerability that serve to inhibit deployment of advanced instrumentation (e.g., sensors, actuators, microcontrollers) with EDDs in nuclear power applications. The research objectives address the challenge of establishing high levels of safety and reliability assurance needed for the qualification of EDDs (e.g., microprocessors, programmable logic devices) that are subject to software design faults, complex failure modes, and CCF vulnerability. Specific objectives are: (1) assess the regulatory context for treatment of CCF vulnerability a graded approach to their qualification, (3) develop and extend model-based testing methods to enable effective demonstration of whether devices are subject to CCF, which may arise from vulnerabilities introduced at any stage of the design lifecycle, (4) establish a cost-effective testing framework that incorporates automation and test scenario prioritization, and (5) demonstrate the qualification approach through selection and testing of candidate digital device(s). This report documents an assessment of the results from experimental testing of a representative instrument with an embedded digital device. The experiment serves as a proof-of-concept demonstration of a model-based testing (MBT) framework. The objective of MBT is to ensure that an EDD undergoes suitably comprehensive testing to establish that it is not subject to SCCF. The approach by which MBT accomplishes this objective is through development and application of an effective test suite that provides the appropriate coverage to detect the full range of postulated faults that may arise at the requirements, design, and code (implementation) level of the EDD software. The findings of the experiment involve the application of the MBT framework by Ohio State University (OSU) through testing of the selected demonstration instrument (i.e., the prototype smart pressure sensor developed by Virginia Commonwealth University, VCU). In addition, the experiment findings also involve application of a more conventional black-box testing approach that serves as a baseline against which the MBT methodology can be compared. The primary outcome documented in this report is the comparative analysis of the capabilities demonstrated for each method. The results of the analysis demonstrate clear benefits that arise from the MBT methodology. The comparison indicates greater effectiveness from the more comprehensive evidence available through MBT and enhanced efficiency achieved through automation within the MBT framework. The structure of the report addresses the approach and application of each test method as well as the comparative analysis of the experimental results. Chapter 2 gives a summary overview of the demonstration approach. Chapter 3 covers the baseline testing and Chapter 4 documents the model-based testing. Chapter 5 describes the findings of the comparative analysis and presents the conclusions that can be drawn about the effectiveness and efficiency of the MBT methodology.

47 OTHER INSTRUMENTATION↗