Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging System Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

A High-Sensitivity Fast Neutron Imager

A wide range of NSC (Neutron Scatter Camera) activities were conducted under this lifecycle plan. This document outlines the highlights of those activities, broadly characterized as system improvements, laboratory measurements, and deployments, and presents sample results in these areas. Additional information can be found in the documents that reside in WebPMIS.

47 OTHER INSTRUMENTATION↗

Design Considerations Of A Compton Camera For Low Energy Medical Imaging

Development of a Compton camera for low energy medical imaging applications is underway. The ProSPECTus project aims to utilize position sensitive detectors to generate high quality images using electronic collimation. This method has the potential to significantly increase the imaging efficiency compared with mechanically collimated SPECT systems, a highly desirable improvement on clinical systems. Design considerations encompass the geometrical optimisation and evaluation of image quality from the system which is to be built and assessed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An imaging technique for detection and absolute calibration of scintillation light

Triggered by the need of a detection system to be used in experiments of nuclear fusion in laser-generated plasmas, we developed an imaging technique for the measurement and calibration of the scintillation light yield of scintillating materials. As in such experiments, all the reaction products are generated in an ultrashort time frame, the event-by-event data acquisition scheme is not feasible. As an alternative to the emulsion technique (or the equivalent CR39 sheets) we propose a scintillating screen readout by means of a high performance charge coupled device camera. Even though it is not strictly required in the particular application, this technique allows the absolute calibration of the scintillation light yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ultrafast pixel array camera system and its applications in high energy density physics

Diagnostics in high energy density physics, shock physics, and related fields are primarily driven by a need to record rapidly time-evolving signals in single-shot events. These measurements are often limited by channel count and signal degradation issues on cable links between the detector and digitizer. Here we present the Ultrafast Pixel Array Camera (UPAC), a compact and flexible detector readout system with 32 waveform-recording channels at up to 10 Gsample/s and 1.8 GHz analog bandwidth. The compact footprint allows the UPAC to be directly embedded in the detector environment. A key enabling technology is the PSEC4A chip, an eight-channel switch-capacitor array sampling device with up to 1056 samples/channel. The UPAC system includes a high-density input connector that can plug directly into an application-specific detector board, programmable control, and serial readout, with less than 5 W of power consumption in full operation. We present the UPAC design and characterization, including a measured timing resolution of ~20 ps or better on acquisitions of sub-nanosecond pulses with minimal system calibrations. Example applications of the UPAC are also shown to demonstrate operation of a solid-state streak camera, an ultrafast imaging array, and a neutron time-of-flight spectrometer.

47 OTHER INSTRUMENTATION↗

Red nuggets grow inside-out: evidence from gravitational lensing

Here, we present a new sample of strong gravitational lens systems where both the foreground lenses and background sources are early-type galaxies. Using imaging from Hubble Space Telescope (HST)/Advanced Camera for Studies (ACS) and Keck/NIRC2, we model the surface brightness distributions and show that the sources form a distinct population of massive, compact galaxies at redshifts 0.4 ≲ z ≲ 0.7, lying systematically below the size–mass relation of the global elliptical galaxy population at those redshifts. These may therefore represent relics of high-redshift red nuggets or their partly evolved descendants. We exploit the magnifying effect of lensing to investigate the structural properties, stellar masses and stellar populations of these objects with a view to understanding their evolution. We model these objects parametrically and find that they generally require two Sérsic components to properly describe their light profiles, with one more spheroidal component alongside a more envelope-like component, which is slightly more extended though still compact. This is consistent with the hypothesis of the inside-out growth of these objects via minor mergers. Lastly, we also find that the sources can be characterized by red-to-blue colour gradients as a function of radius which are stronger at low redshift – indicative of ongoing accretion – but that their environments generally appear consistent with that of the general elliptical galaxy population, contrary to recent suggestions that these objects are pre-dominantly associated with clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Fielding of a Time-Resolved Tomographic Diagnostic

A diagnostic instrument has been developed for the acquisition of high-speed time-resolved images at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility at Los Alamos National Laboratory. The instrument was developed in order to create time histories of the electron beam. Four discrete optical subsystems view Cerenkov light generated at an x-ray target inside of a vacuum envelope. Each system employs cylindrical optics to image light in one direction and collapse light in the orthogonal direction. Each of the four systems images and collapses in unique axes, thereby capturing unique information. Light along the imaging axis is relayed via optical fiber to streak cameras. A computer is used to reconstruct the original image from the four optically collapsed images. Due to DARHT’s adverse environment, the instrument can be operated remotely to adjust optical parameters and contains a subsystem for remote calibration. The instrument was deployed and calibrated, and has been used to capture and reconstruct images. Matters of alignment, calibration, control, resolution, and adverse conditions will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fielding of a time-resolved tomographic diagnostic

A diagnostic instrument has been developed for the acquisition of high-speed time-resolved images at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility at Los Alamos National Laboratory. The instrument was developed in order to create time histories of the electron beam. Four discrete optical subsystems view Cerenkov light generated at an X-ray target inside of a vacuum envelope. Each system employs cylindrical optics to image light in one direction and collapse light in the orthogonal direction. Each of the four systems images and collapses in unique axes, thereby capturing unique information. Light along the imaging axis is relayed via optical fiber to streak cameras. A computer is used to reconstruct the original image from the four optically collapsed images. Due to DARHT’s adverse environment, the instrument can be operated remotely to adjust optical parameters and contains a subsystem for remote calibration. The instrument was deployed and calibrated, and has been used to capture and reconstruct images. Matters of alignment, calibration, control, resolution, adverse conditions and maintenance will be discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MAXI Nova Alert System and the Latest Scientific Results

MAXI, Monitor of All-sky X-ray Image, is the first astronomical telescope onboard the ISS. One of the main goals of our mission is to discover new transient objects by scanning more than 95% of the sky every {approx}92 min with two types of X-ray cameras, Gas Slit Camera (GSC) and Solid-state Slit Camera (SSC). We have developed a completely new data analysis system, a nova alert system, to find transient objects and send alerts to the world as soon as possible. Here we describe the current status of the system, and transient objects discovered with the system.

79 ASTRONOMY AND ASTROPHYSICS↗

Wide-angle ITER-prototype tangential infrared and visible viewing system for DIII-D

An imaging system with a wide-angle tangential view of the full poloidal cross-section of the tokamak in simultaneous infrared and visible light has been installed on DIII-D. The optical train includes three polished stainless steel mirrors in vacuum, which view the tokamak through an aperture in the first mirror, similar to the design concept proposed for ITER. A dichroic beam splitter outside the vacuum separates visible and infrared (IR) light. Spatial calibration is accomplished by warping a CAD-rendered image to align with landmarks in a data image. The IR camera provides scrape-off layer heat flux profile deposition features in diverted and inner-wall-limited plasmas, such as heat flux reduction in pumped radiative divertor shots. Demonstration of the system to date includes observation of fast-ion losses to the outer wall during neutral beam injection, and shows reduced peak wall heat loading with disruption mitigation by injection of a massive gas puff.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility Testing of Delayed Scintillator Screens for Indirect Digital Neutron Radiography of Irradiated Nuclear Fuel

Neutron radiography provides information about the internal condition of irradiated nuclear fuels. Traditionally, neutron radiography of highly radioactive irradiated nuclear fuels has been done with film using indirect radiography methods.[1] While indirect film neutron radiography is insensitive to gamma radiation from radioactive samples, it is a time-consuming and labor-intensive process. Digital neutron radiography requires a fraction of the time to produce a neutron radiograph compared to film-based processes. However, electronic components of digital radiography systems can easily be damaged by gamma radiation, which typically precludes use of digital systems for examination of highly radioactive objects, though recent work has demonstrated that some digital neutron radiography systems can indeed directly examine such samples.[2,3] This paper describes experiments performed using a hybrid transfer-digital method with an activated scintillator screen that can record an image that is subsequently read by a digital camera. The screens used in this study use a dysprosium neutron converter that records a latent image in the form of activation while in a neutron beam, then is physically transported away from the beam and sample to a digital camera elsewhere to record the image while the activated dysprosium decays and the adjacent scintillator produces light from interactions with the decay radiation. This approach could accelerate radiographic examination of irradiated nuclear fuels compared to the current transfer method with film. Current indirect imaging infrastructure was modified and augmented with a digital system. A digital neutron radiograph of a highly-radioactive irradiated nuclear fuel pins was produced in ~20 minutes, which is a significant improvement compared to the current process that takes almost a full day to produce a radiograph.

99 GENERAL AND MISCELLANEOUS↗

CHARACTERIZATION OF OPTICALLY SELECTED STAR-FORMING KNOTS IN (U)LIRGs

We present a comprehensive characterization of the general properties (luminosity functions (LFs), mass, size, ages, etc.) of optically selected compact stellar objects (knots) in a representative sample of 32 low-z luminous and ultraluminous infrared galaxies ((U)LIRGs). It is important to understand the formation and evolution of these properties in such systems, which represent the most extreme cases of starbursts in the low-z universe. We have made use of high angular resolution Advanced Camera for Surveys images from the Hubble Space Telescope in F435W ({approx}B) and F814W ({approx}I) bands. The galaxies in the sample represent different interaction phases (first contact, pre-merger, merger, and post-merger) and cover a wide luminosity range (11.46 {<=} log (L{sub IR}/L{sub sun}) {<=} 12.54). With a median size of 32 pc, most of the nearly 3000 knots detected consist of complexes of star clusters. Some of the knots ({approx}15%) are so blue that their colors indicate a young (i.e., <30 Myr) and almost extinction-free population. There is a clear correlation of the mass of these blue knots with their radius, where M{proportional_to}R{sup 1.91{+-}0.14}, similar to that found in complexes of clusters in M51 and in giant molecular clouds. This suggests that the star formation within the knots is proportional to the gas density at any given radius. This relation does not depend significantly on either the infrared luminosity of the system or the interaction phase. The star formation of all the knots is characterized by LFs of the knots with slopes close to 2. Nevertheless, we see a marginally significant indication that the LF evolves with the interaction process, becoming steeper from early to advanced merger phases. Due to size-of-sample effects we are probably sampling knots in ULIRGs that intrinsically more luminous (by a factor of about four) than in less luminous systems. They also have sizes and are likely to have masses characteristic of clumps in galaxies at z {approx}> 1. Knots in post-mergers are on average (1.3-2 times) larger, more luminous (2 mag) in the I band, and 0.5 mag redder than those in systems in earlier phases. Two scenarios are briefly discussed: (1) the likely presence of relatively high extinction in the most advanced mergers and (2) the dissolution of the less massive clusters and/or their coalescence into more massive, evolved superclusters.

79 ASTRONOMY AND ASTROPHYSICS↗

THE HUBBLE WIDE FIELD CAMERA 3 TEST OF SURFACES IN THE OUTER SOLAR SYSTEM: SPECTRAL VARIATION ON KUIPER BELT OBJECTS

Here, we present additional photometry of targets observed as part of the Hubble Wide Field Camera 3 (WFC3) Test of Surfaces in the Outer Solar System. Twelve targets were re-observed with the WFC3 in the optical and NIR wavebands designed to complement those used during the first visit. Additionally, all of the observations originally presented by Fraser and Brown were reanalyzed through the same updated photometry pipeline. A re-analysis of the optical and NIR color distribution reveals a bifurcated optical color distribution and only two identifiable spectral classes, each of which occupies a broad range of colors and has correlated optical and NIR colors, in agreement with our previous findings. We report the detection of significant spectral variations on five targets which cannot be attributed to photometry errors, cosmic rays, point-spread function or sensitivity variations, or other image artifacts capable of explaining the magnitude of the variation. The spectrally variable objects are found to have a broad range of dynamical classes and absolute magnitudes, exhibit a broad range of apparent magnitude variations, and are found in both compositional classes. The spectrally variable objects with sufficiently accurate colors for spectral classification maintain their membership, belonging to the same class at both epochs. 2005 TV189 exhibits a sufficiently broad difference in color at the two epochs that span the full range of colors of the neutral class. This strongly argues that the neutral class is one single class with a broad range of colors, rather than the combination of multiple overlapping classes.

79 ASTRONOMY AND ASTROPHYSICS↗

Line Focus Receiver Infrared Temperature Survey System

For ongoing maintenance and performance purposes, solar parabolic trough field operators desire to know that the Heat Collection Elements (HCEs) are performing properly. Measuring their temperature is one way of doing this One 30MW field can contain approximately 10,000 HCE's. This software interfaces with a GPS receiver and an infrared camera. It takes global positioning data from the GPS and uses this information to automate the infrared image capture and temperature analysis of individual solar parabolic HCEs in a solar parabolic trough field With this software system an entire 30MW field can be surveyed in 2-3 days.

Wendelin, Tim↗

Practical reconstruction protocol for quantitative {sup 90}Y bremsstrahlung SPECT/CT

Purpose: To develop a practical background compensation (BC) technique to improve quantitative {sup 90}Y-bremsstrahlung single-photon emission computed tomography (SPECT)/computed tomography (CT) using a commercially available imaging system. Methods: All images were acquired using medium-energy collimation in six energy windows (EWs), ranging from 70 to 410 keV. The EWs were determined based on the signal-to-background ratio in planar images of an acrylic phantom of different thicknesses (2–16 cm) positioned below a {sup 90}Y source and set at different distances (15–35 cm) from a gamma camera. The authors adapted the widely used EW-based scatter-correction technique by modeling the BC as scaled images. The BC EW was determined empirically in SPECT/CT studies using an IEC phantom based on the sphere activity recovery and residual activity in the cold lung insert. The scaling factor was calculated from 20 clinical planar {sup 90}Y images. Reconstruction parameters were optimized in the same SPECT images for improved image quantification and contrast. A count-to-activity calibration factor was calculated from 30 clinical {sup 90}Y images. Results: The authors found that the most appropriate imaging EW range was 90–125 keV. BC was modeled as 0.53× images in the EW of 310–410 keV. The background-compensated clinical images had higher image contrast than uncompensated images. The maximum deviation of their SPECT calibration in clinical studies was lowest (<10%) for SPECT with attenuation correction (AC) and SPECT with AC + BC. Using the proposed SPECT-with-AC + BC reconstruction protocol, the authors found that the recovery coefficient of a 37-mm sphere (in a 10-mm volume of interest) increased from 39% to 90% and that the residual activity in the lung insert decreased from 44% to 14% over that of SPECT images with AC alone. Conclusions: The proposed EW-based BC model was developed for {sup 90}Y bremsstrahlung imaging. SPECT with AC + BC gave improved lesion detectability and activity quantification compared to SPECT with AC only. The proposed methodology can readily be used to tailor {sup 90}Y SPECT/CT acquisition and reconstruction protocols with different SPECT/CT systems for quantification and improved image quality in clinical settings.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Pan-STARRS Data Processing and Science Analysis Software Systems

The Panoramic Survey Telescope and Rapid Response System (Pan-STARRS) will use gigapixel CCD cameras on multiaperture telescopes to survey the sky in the visible and infrared bands. A single telescope system (PS1) has been deployed on Maui, and a four-telescope system (PS4) will be sited on Mauna Kea on the Big Island of Hawaii. These systems will survey the sky repeatedly and will generate petabytes of image data and catalogs of billions of stars and galaxies. Each set of images will be combined to create a very sensitive multicolor image of the sky, and differences between images will provide for a massive database of 'time domain astronomy' including the study of moving objects and transient or variable objects. All data from PS1 will be put into the public domain following its 3.5 year survey. The project faces formidable challenges in processing the image data in near real time and making the catalog data accessible via relational databases. In this talk, I describe the software systems developed by the Pan-STARRS project and how these core systems will be augmented by an assortment of science 'servers' being developed by astronomers in the PS1 Science Consortium.

79 ASTRONOMY AND ASTROPHYSICS↗

Spinning metasurface stack for spectro-polarimetric thermal imaging

Spectro-polarimetric imaging in the long-wave infrared (LWIR) region plays a crucial role in applications from night vision and machine perception to trace gas sensing and thermography. However, the current generation of spectro-polarimetric LWIR imagers suffers from limitations in size, spectral resolution, and field of view (FOV). While meta-optics-based strategies for spectro-polarimetric imaging have been explored in the visible spectrum, their potential for thermal imaging remains largely unexplored. In this work, we introduce an approach for spectro-polarimetric decomposition by combining large-area stacked meta-optical devices with advanced computational imaging algorithms. The co-design of a stack of spinning dispersive metasurfaces along with compressive sensing and dictionary learning algorithms allows simultaneous spectral and polarimetric resolution without the need for bulky filter wheels or interferometers. Our spinning-metasurface-based spectro-polarimetric stack is compact (<10×10×10cm) and robust, and it offers a wide field of view (20.5°). We show that the spectral resolving power of our system substantially enhances performance in machine learning tasks such as material classification, a challenge for conventional panchromatic thermal cameras. Our approach represents a significant advance in the field of thermal imaging for a wide range of applications including heat-assisted detection and ranging (HADAR).

Optics↗

Optical eye tracking system for real-time noninvasive tumor localization in external beam radiotherapy

Purpose: External beam radiotherapy currently represents an important therapeutic strategy for the treatment of intraocular tumors. Accurate target localization and efficient compensation of involuntary eye movements are crucial to avoid deviations in dose distribution with respect to the treatment plan. This paper describes an eye tracking system (ETS) based on noninvasive infrared video imaging. The system was designed for capturing the tridimensional (3D) ocular motion and provides an on-line estimation of intraocular lesions position based on a priori knowledge coming from volumetric imaging. Methods: Eye tracking is performed by localizing cornea and pupil centers on stereo images captured by two calibrated video cameras, exploiting eye reflections produced by infrared illumination. Additionally, torsional eye movements are detected by template matching in the iris region of eye images. This information allows estimating the 3D position and orientation of the eye by means of an eye local reference system. By combining ETS measurements with volumetric imaging for treatment planning [computed tomography (CT) and magnetic resonance (MR)], one is able to map the position of the lesion to be treated in local eye coordinates, thus enabling real-time tumor referencing during treatment setup and irradiation. Experimental tests on an eye phantom and seven healthy subjects were performed to assess ETS tracking accuracy. Results: Measurements on phantom showed an overall median accuracy within 0.16 mm and 0.40° for translations and rotations, respectively. Torsional movements were affected by 0.28° median uncertainty. On healthy subjects, the gaze direction error ranged between 0.19° and 0.82° at a median working distance of 29 cm. The median processing time of the eye tracking algorithm was 18.60 ms, thus allowing eye monitoring up to 50 Hz. Conclusions: A noninvasive ETS prototype was designed to perform real-time target localization and eye movement monitoring during ocular radiotherapy treatments. The device aims at improving state-of-the-art invasive procedures based on surgical implantation of radiopaque clips and repeated acquisition of X-ray images, with expected positive effects on treatment quality and patient outcome.

60 APPLIED LIFE SCIENCES↗

Monitoring external beam radiotherapy using real-time beam visualization

Purpose: To characterize the performance of a novel radiation therapy monitoring technique that utilizes a flexible scintillating film, common optical detectors, and image processing algorithms for real-time beam visualization (RT-BV). Methods: Scintillating films were formed by mixing Gd{sub 2}O{sub 2}S:Tb (GOS) with silicone and casting the mixture at room temperature. The films were placed in the path of therapeutic beams generated by medical linear accelerators (LINAC). The emitted light was subsequently captured using a CMOS digital camera. Image processing algorithms were used to extract the intensity, shape, and location of the radiation field at various beam energies, dose rates, and collimator locations. The measurement results were compared with known collimator settings to validate the performance of the imaging system. Results: The RT-BV system achieved a sufficient contrast-to-noise ratio to enable real-time monitoring of the LINAC beam at 20 fps with normal ambient lighting in the LINAC room. The RT-BV system successfully identified collimator movements with sub-millimeter resolution. Conclusions: The RT-BV system is capable of localizing radiation therapy beams with sub-millimeter precision and tracking beam movement at video-rate exposure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗