Search NASA⌕ Search

SEARCH · Search NASA

Results for “Importance Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

INVESTIGATION OF THE MULTILAYER SHIELDING EFFECT THROUGH NbTiN-AlN COATED BULK NIOBIUM

Superconducting radio frequency (SRF) cavities, composed of bulk niobium (Nb), are extensively utilized in particle accelerators. To optimize their performance and extend their operational range, thin films of superconducting materials are applied to the Nb surfaces. This study focuses on investigating the magnetic field penetration characteristics of NbTiN-AlN coating on bulk niobium. The experimental setup involves measuring the magnetic field penetration across flat superconducting samples at cryogenic temperatures. One key parameter of interest is the field just before the first flux penetration, Bp which enables the observation of the multilayer shielding effect on bulk niobium under high magnetic fields. The study reveals a significant enhancement in Bp of the NbTiN-AlN coated Nb samples compared to bare Nb samples. This property holds critical importance for achieving high field performance in SRF cavities. Furthermore, the study explores the relationship between coating thickness and Bp corroborating the theoretical predictions.

Senevirathne, I. H.↗

Why natural monazite never becomes amorphous: Experimental evidence for alpha self-healing

Monazite, a common accessory rare-earth orthophosphate mineral in the continental crust widely used in U-Pb geochronology, holds promise for (U-Th)/He thermochronology and for the immobilization of Pu and minor actinides (MA) coming from spent nuclear fuel reprocessing. Previous results obtained on natural and plutonium-doped monazite have demonstrated the ability of this structure to maintain a crystalline state despite high radiation damage levels. However, the low critical temperature (180 °C), above which amorphization cannot be achieved in natural monazite under ion irradiation, does not explain this old and unsolved paradox: why do natural monazites, independent of their geological history, remain crystalline even when they did not experience any thermal event that could heal the defects? This is what the present study aims to address. Synthetic polycrystals of LaPO 4 -monazite were irradiated sequentially and simultaneously with α particles (He) and gold (Au) ions. Here, our results demonstrate experimentally for the first time in monazite, the existence of the defect recovery mechanism, called α-healing, acting in this structure due to electronic energy loss of α particles, which explains the absence of amorphization in natural monazite samples. This mechanism is critically important for monazite geo- and thermochronology and to design and predictively model the long-term behavior of ceramic matrices for nuclear waste conditioning.

36 MATERIALS SCIENCE↗

FY 2014 Status Report: of Vibration Testing of Clad Fuel (M4FT-14OR0805033)

The DOE Used Fuel Disposition Campaign (UFDC) tasked Oak Ridge National Laboratory (ORNL) to investigate the behavior of light-water-reactor (LWR) fuel cladding material performance related to extended storage and transportation of UNF. ORNL has been tasked to perform a systematic study on UNF integrity under simulated normal conditions of transportation (NCT) by using the recently developed hot-cell testing equipment, Cyclic Integrated Reversible-Bending Fatigue Tester (CIRFT). To support the testing on actual high-burnup UNF, fast-neutron irradiation of pre-hydrided zirconium-alloy cladding in the High Flux Isotope Reactor (HFIR) at elevated temperatures will be used to simulate the effects of high-burnup on fuel cladding for help in understanding the cladding materials properties relevant to extended storage and subsequent transportation. The irradiated pre-hydrided metallic materials testing will generate baseline data to benchmark hot-cell testing of the actual high-burnup UNF cladding. More importantly, the HFIR-irradiated samples will be free of alpha contamination and can be provided to researchers who do not have hot cell facilities to handle highly contaminated high-burnup UNF cladding to support their research projects for the UFDC.t

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tractable Experiment Design via Mathematical Surrogates

This presentation summarizes the development and implementation of quantitative design criteria motivated by targeted inference objectives for identifying new, potentially expensive computational or physical experiments. The first application is concerned with estimating features of quantities of interest arising from complex computational models, such as quantiles or failure probabilities. A sequential strategy is proposed for iterative refinement of the importance distributions used to efficiently sample the uncertain inputs to the computational model. In the second application, effective use of mathematical surrogates is investigated to help alleviate the analytical and numerical intractability often associated with Bayesian experiment design. This approach allows for the incorporation of prior information into the design process without the need for gross simplification of the design criterion. Illustrative examples of both design problems will be presented as an argument for the relevance of these research problems.

97 MATHEMATICS AND COMPUTING↗

Auxiliary-Field Quantum Monte Carlo Simulations of Strongly-Correlated Molecules and Solids

We propose a method of implementing projected wave functions for second-quantized auxiliary-field quantum Monte Carlo (AFQMC) techniques. The method is based on expressing the two-body projector as one-body terms coupled to binary Ising fields. To benchmark the method, we choose to study the two-dimensional (2D) one-band Hubbard model with repulsive interactions using the constrained-path MC (CPMC). The CPMC uses a trial wave function to guide the random walks so that the so-called fermion sign problem can be eliminated. The trial wave function also serves as the importance function in Monte Carlo sampling. As such, the quality of the trial wave function has a direct impact to the efficiency and accuracy of the simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of Stress-Free Lattice Spacing (D₀) for Residual Stress Relaxation Measurement in Ni-based Superalloys by Neutron Diffraction

The residual stress and its relaxation in critical engineering components are key to structural materials reliability. The determination of residual stress in bulk engineering structures like Ni-based superalloys can be conducted by measuring the lattice strain with penetrating neutron diffraction. The state-of-the-art engineering diffraction beamline VULCAN at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS) provides the critical capability to evaluate the residual strain/stress relaxation in engineering component thanks to the high flux and event data features. By the means of residual stress/strain calculation, it is critical to accurately determine the stress-free lattice spacing d₀, which can be altered by the change of chemistry, unrelieved stress, and measurement scheme. Here we reported d₀ determination for determining residual stress relaxation and distribution in Alloy 718 superalloys after different quenching treatments. Selection of locations for d₀ measurement was discussed by considering the neutron path, attenuation and sample alignment. A dynamic d₀ that resulted from atom diffusion and chemistry change was estimated as function of time for the in-situ relaxation characterization. It demonstrated how the dynamic d₀ values may influence on the strain calculation in different thermally treated samples. The results highlight the importance of dynamic d₀ for in-situ relaxation involving chemical changes and provide guidance to the dynamic d₀ measurement and simulation.

36 MATERIALS SCIENCE↗

EQ-SANS Detector Distance Check with Laser Alignment Method

In Small-Angle Scattering experiments, accurate distance information between sample and the detector is important. During the winter outage, January 2021, positions of detector, especially along the beam direction, were measured with the laser alignment tool to confirm values regularly deduced from silver behenate measurements. The results show that the current detector-z position of the EQ-SANS is accurate at all typically used detector positions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reexamining Circular Dichroism in Photoemission From a Topological Insulator

The orbital angular momentum (OAM) of electron states is an essential ingredient for topological and quantum geometric quantities in solids. For example, Dirac surface states with helical spin- and orbital-angular momenta are a hallmark of a 3D topological insulator. Angle-resolved photoemission spectroscopy (ARPES) with variable circular light polarization, known as circular dichroism (CD), has been assumed to be a direct probe of OAM and, by proxy, of the Berry curvature of electronic bands in energy- and momentum-space. Indeed, topological surface states have been shown to exhibit angle-dependent CD (CDAD), and more broadly, CD is often interpreted as evidence of spin-orbit coupling. Meanwhile, it is well-established that CD originates from the photoemission matrix elements, which can have extrinsic contributions related to the experimental geometry and the inherently broken inversion symmetry at the sample surface. Therefore, it is important to broadly examine CD-ARPES to determine the scenarios in which it provides a robust probe of intrinsic material physics. We performed CD-ARPES on the canonical topological insulator $\mathrm{Bi}_2\mathrm{Se}_3$ over a wide range of incident photon energies. Not only do we observe angle-dependent CD in the surface states, as expected, but we also find CD of a similar magnitude in virtually all bulk bands. Since OAM is forbidden by inversion symmetry in the bulk, we conclude this originates from symmetry-breaking in the photoemission process. Comparison with theoretical calculations supports this view and suggests that $\textit{hidden}$ OAM - localized to atomic sites within each unit cell - contributes significantly. Additional effects, including inter-atomic interference and final-state resonances, are responsible for the rapid variation of the CDAD signal with photon energy.

FOS: Physical sciences↗

ISOTOPIC COMPOSITIONS OF URANIUM REFERENCE MATERIALS

Uranium isotopic compositions of a variety of U standard materials were measured at Lawrence Livermore National Laboratory and are reported here. Both thermal ionization mass spectrometry (TIMS) and multi-collector inductively couple plasma mass spectrometry (MC-ICPMS) were used to determine ratios of the naturally occurring isotopes of U. Establishing an internally coherent set of isotopic values for a range of U standards is essential for inter-laboratory comparison of small differences in {sup 238}U/{sup 235}U, as well as the minor isotopes of U. Differences of {approx} 1.3{per_thousand} are now being observed in {sup 238}U/{sup 235}U in natural samples, and may play an important role in understanding U geochemistry where tracing the origin of U is aided by U isotopic compositions. The {sup 238}U/{sup 235}U ratios were measured with a TRITON TIMS using a mixed {sup 233}U-{sup 236}U isotopic tracer to correct for instrument fractionation. this tracer was extremely pure and resulted in only very minor corrections on the measured {sup 238}U/{sup 235}U ratios of {approx} 0.03. The values obtained for {sup 238}U/{sup 235}U are: IRMM184 = 137.698 {+-} 0.020 (n = 15), SRM950a = 137.870 {+-} 0.018 (n = 8), and CRM112a = 137.866 {+-} 0.030 (n = 16). Uncertainties represent 2 s.d. of the population. The measured value for IRMM184 is in near-perfect agreement with the certified value of 137.697 {+-} 0.042. However, the U isotopic compositions of SRM950a and CRM112a are not certified. Minor isotopes of U were determined with a Nu Plasma HR MC-ICPMS and mass bias was corrected by sample/standard bracketing to IRMM184, using its certified {sup 238}U/{sup 235}U ratio. Thus, the isotopic compositions determined using both instruments are compatible. The values obtained for {sup 234}U/{sup 235}U are: SRM950a = (7.437 {+-} 0.043) x 10{sup -3} (n = 18), and CRM112a = (7.281 {+-} 0.050) x 10{sup -3} (n = 16), both of which are in good agreement with published values. The value for {sup 236}U/{sup 235}U in SRM950a was determined to be (8.48 {+-} 2.63) x 10{sup -6}, whereas {sup 236}U was not detected in CRM112a. They are currently obtaining the U isotopic composition of CRM129a. Preliminary results suggest that the {sup 238}U/{sup 235}U ratio is within error, but slightly lower than the certified value of 137.71.

58 GEOSCIENCES↗

Comparison of EXAFS Foil Spectra from Around the World

The EXAFS spectra of Cu and Pd foil from many different beamlines and synchrotrons are compared to address the dependence of the amplitude reduction factor (S{sub 0}{sup 2}) on beamline specific parameters. Even though S{sub 0}{sup 2} is the same parameter as the EXAFS coordination number, the value for S{sub 0}{sup 2} is given little attention, and is often unreported. The S{sub 0}{sup 2} often differs for the same material due to beamline and sample attributes, such that no importance is given to S{sub 0}{sup 2}-values within a general range of 0.7 to 1.1. EXAFS beamlines have evolved such that it should now be feasible to use standard S{sub 0}{sup 2} values for all EXAFS measurements of a specific elemental environment. This would allow for the determination of the imaginary energy (Ei) to account for broadening of the EXAFS signal rather than folding these errors into an effective S{sub 0}{sup 2}-value. To test this concept, we model 11 Cu-foil and 6 Pd-foil EXAFS spectra from around the world to compare the difference in S{sub 0}{sup 2}- and Ei-values.

47 OTHER INSTRUMENTATION↗

Optimization of FRAM precision for isotopic measurements on large samples of low-burnup PuO2

The gamma ray spectrum of plutonium contains measurable gamma rays ranging in energy from 60 keV to above 1 MeV. The FRAM gamma ray isotopic analysis code can analyze data from all types of HPGe detectors in this energy range typically using planar detectors in the energy range 60-210 keV or 120-451 keV and using coaxial detectors in the energy ranges 120-451 keV or 200-1001 keV. The statistical measurement precision depends upon the detector/energy range combination as well as the characteristics of the sample and any addition filters. In this paper we carry out the optimization of measurement precision for the important case of a multi-kg sample of low bumup PuO{sub 2} contained in a DOE 3013 Standard-compatible long-teml storage container.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Surfactant-assisted one-pot sample preparation for label-free single-cell proteomics

Large numbers of cells are generally required for quantitative global proteome profiling due to surface adsorption losses associated with sample processing. Such bulk measurement obscures important cell-to-cell variability (cell heterogeneity) and makes proteomic profiling impossible for rare cell populations (e.g., circulating tumor cells (CTCs)). Here we report a surfactant-assisted one-pot sample preparation coupled with mass spectrometry (MS) method termed SOP-MS for label-free global single-cell proteomics. SOP-MS capitalizes on the combination of a MS-compatible nonionic surfactant, n-Dodecyl-β-D-maltoside, and hydrophobic surface-based low-bind tubes or multi-well plates for ‘all-in-one’ one-pot sample preparation. This ‘all-in-one’ method including elimination of all sample transfer steps maximally reduces surface adsorption losses for effective processing of single cells, thus improving detection sensitivity for single-cell proteomics. This method allows convenient label-free quantification of hundreds of proteins from single human cells and ~1200 proteins from small tissue sections (close to ~20 cells). When applied to a patient CTC-derived xenograft (PCDX) model at the single-cell resolution, SOP-MS can reveal distinct protein signatures between primary tumor cells and early metastatic lung cells, which are related to the selection pressure of anti-tumor immunity during breast cancer metastasis. The approach paves the way for routine, precise, quantitative single-cell proteomics.

36 MATERIALS SCIENCE↗

XPS Analysis of Nanostructured Materials and Biological Surfaces

This paper examines the types of information that XPS can provide about a variety of nano-structured materials. Although it is sometimes not considered a “nano-scale analysis method” XPS can provide a great deal of information about elemental distributions, layer or coating structure and thicknesses, surface functionality, and even particles sizes on the 1-20 nm scale for samples types that may not be readily analyzed by other methods. This information is important for both synthetic nanostructured or nanosized materials and a variety of natural materials with nanostructure. Although the links between nanostructure materials and biological systems may not at first be obvious, many biological molecules and some organisms are the sizes of nanoparticles. The nanostructure of cells and microbes plays a significant role in how they interact with their environment. The interaction of biomolecules with nanoparticles is important for medical and toxicity studies. The interaction of biomolecules is important for sensor function and many nanomaterials are now the active elements in sensors. This paper first discusses how nanostructures influences XPS data as part of understanding how simple models of sample structure and data analysis can be used to extract information about the physical and chemical structure of the materials being analyzed. Equally important, aspects of sample and analysis limitations and challenges associated with understanding nanostructured materials are indicated. Examples of the application of XPS to nanostructured and biological systems and materials are provided.

54 ENVIRONMENTAL SCIENCES↗

Picoelectrospray Ionization Mass Spectrometry Using Narrow-bore Chemically Etched Emitters

Electrospray ionization mass spectrometry (ESI-MS) at flow rates below ~10 nL/min has been only sporadically explored due to difficulty in reproducibly fabricating emitters that can operate at lower flow rates. Here we demonstrate narrow orifice chemically etched emitters for stable electrospray at flow rates as low as 400 pL/min. Depending on the analyte concentration, we observe two types of MS signal response as a function of flow rate. At low concentrations, an optimum flow rate is observed slightly above 1 nL/min, while the signal decreases monotonically with decreasing flow rates at higher concentrations. In spite of lower MS signal, the ion utilization efficiency increases exponentially with decreasing flow rate in all cases. No unimolecular response was observed within this flow rate range during the analysis of an equimolar mixture of peptides, indicating that ionization efficiency is an analyte-dependent characteristic in given experimental conditions. While little to no gain in signal-to-noise was achieved at ultralow flow rates for concentration-limited analyses, experiments consuming the same amount of analyte suggest that mass-limited analyses will benefit strongly from the use of low flow rates and avoiding unnecessary sample dilution. By operating under optimal conditions, consumption of just 500 zmol of sample yielded signal-to-noise ratios ~10 for some peptides. These findings have important implications for the analysis of trace biological samples.

Environmental Molecular Sciences Laboratory↗

REDSHIFT EVOLUTION IN BLACK HOLE-BULGE RELATIONS: TESTING C IV-BASED BLACK HOLE MASSES

We re-examine claims for redshift evolution in black hole-bulge scaling relations based on lensed quasars. In particular, we refine the black hole (BH) mass estimates using measurements of Balmer lines from near-infrared spectroscopy obtained with Triplespec at Apache Point Observatory. In support of previous work, we find a large scatter between Balmer and UV line widths, both Mg IIlambdalambda2796, 2803 and C IVlambdalambda1548, 1550. There is tentative evidence that C III]lambda1909, despite being a blend of multiple transitions, may correlate well with Mg II, although a larger sample is needed for a real calibration. Most importantly, we find no systematic changes in the estimated BH masses for the lensed sample based on Balmer lines, providing additional support to the interpretation that black holes were overly massive compared to their host galaxies at high redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved Nested Sampling and Surrogate-Enabled Comparison With Other Marginal Likelihood Estimators

Estimating marginal likelihood is of central importance to Bayesian model selection and/or model averaging. The nested sampling method has been recently used together with the Metropolis-Hasting (M-H) sampling algorithm for estimating marginal likelihood. This study develops a new implementation of nested sampling by using the DiffeRential Evolution Adaptive Metropolis (DREAMzs) sampling algorithm. The two implementations of nested sampling are evaluated for four models of a synthetic groundwater flow modeling. The DREAMzs-based nested sampling outperforms the M-H-based nested sampling in terms of their accuracy, convergence, efficiency, and stability, which is attributed to the fact that DREAMzs is more robust than M-H for parameter sampling. The nested sampling method is also compared with four other methods (arithmetic mean, harmonic mean, stabilized harmonic mean, and thermodynamic integration) commonly used for estimating marginal likelihood and posterior probability of the four groundwater models. The comparative study requires hundreds of millions of model executions, which would not be possible without using surrogate models to replace the original models. Using the arithmetic mean estimator as the reference, the comparison reveals that thermodynamic integration outperforms nested sampling in terms of accuracy and stability, whereas nested sampling is more computationally efficient to reach to convergence. Here, the harmonic mean and stabilized harmonic mean methods give the worst marginal likelihood estimation. Accurate marginal likelihood estimation is important for accurate estimation of posterior model probability and better predictive performance of Bayesian model averaging.

54 ENVIRONMENTAL SCIENCES↗

A Method for Rapid and Precise Triple Oxygen Isotope Measurements via High-Temperature Conversion to CO Followed by Nickel-Catalyzed CO to CO 2 Conversion and Laser Spectroscopy

Triple oxygen isotopic compositions ( 16 O, 17 O, 18 O) have conventionally been measured via isotope ratio mass spectrometry using O 2 as an analyte. Conversion of sample oxygen to O 2 typically utilizes fluorination chemistry or catalytic equilibration between CO 2 and O 2 . Recently, laser spectroscopy has become a viable alternative for triple oxygen isotope (Δ' 17 O) measurements due to its ease and rapid throughput. Laser spectrometers are currently available for Δ' 17 O analysis of either H 2 O or CO 2 as the analyte gas. So far, these instruments have been used to measure Δ' 17 O of water, carbonate (CO 2 liberated by acid digestion), and atmospheric CO 2 samples. Here, we present a new method for high-precision Δ' 17 O analysis of CO 2 via tunable infrared laser direct absorption spectroscopy that is compatible with a wider range of geochemically important materials. This approach involves converting sample oxygen to CO 2 in two steps. First, the sample oxygen is liberated and reduced to CO by high-temperature conversion at 1450 °C in the presence of excess elemental carbon. Then, CO is catalytically converted to CO 2 over hot nickel at 350 °C. The conversion process is rapid (10 to 30 min) and quantitative. Spectroscopic Δ' 17 O analysis of the resulting CO 2 takes approximately 45 min. By measuring several oxygen isotope standards, we demonstrate that the method is precise (1σ = 12 per meg for procedural replicates) and accurate (within 11 per meg of previously reported values). The method can be applied to most pyrolytic materials where quantitative oxygen conversion is attainable, such as sulfate, phosphate, nitrate, and oxide minerals, water, and organic molecules.

Ellis, Nicholas M. [University of California, Berk↗

Artifact-Free Coring Procedures for Removing Samples from Photovoltaic Modules for Microscopic Analysis

An important step in producing more reliable and efficient photovoltaic modules is to establish a relationship between the microscopic properties of modules deployed in the field for many years and efficiency-related parameters. The first step in accomplishing this task is to be able to identify and remove small areas from these modules without causing any damage to these samples. In this work, we will describe two different procedures to core small areas of deployed and stressed solar panels produced with different materials (Si, CIGS, and CdTe), and we will prove that these processes did not damage the cored material. We will also show that the coring procedure changes for different types of photovoltaic modules.

14 SOLAR ENERGY↗