Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inlet diffusers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Supersonic Wind Tunnels (Latest Citations from the Aerospace Database)

The bibliography contains citations concerning the design, construction, operation, performance, and use of supersonic wind tunnels. References cover the design of flow nozzles, diffusers, test sections, and ejectors for tunnels driven by compressed air, high-pressure gases, or cryogenic liquids. Methods for flow calibration, boundary layer control, local and freestream turbulence reduction, and force measurement are discussed. Instrusive and non-intrusive instrumentation, sources of measurement error, and measurement corrections are also covered. The citations also include the testing of inlets, nozzles, airfoils, and other components of aerospace vehicles that must operate supersonically. Comprehensive coverage of wind tunnel force balancing systems, and blowdown and supersonic wind tunnels are covered in separate bibliographies.(Contains 50-250 citations and includes a subject term index and title list.)

WIND TUNNELS↗

Syngas formation in methane flames and carbon monoxide release during quenching

Following a recent investigation into chemi-ionization and chemiluminescence during gradual aeration of small, laminar methane flames, we proposed that partial oxidation products, or syngas constituents, formed in the pre-flame zone well below the luminous region, were responsible for the observed effects. We therefore map temperature, CO, and H{sub 2} for geometries and conditions relevant to burners in domestic boiler systems, to assess the potential hazard of CO release into the ambient atmosphere, should any partial quenching occur. CO concentrations peaks of 5.5 volume % are recorded in the core surrounding the axis. Appreciable CO concentrations are also found in the absence of added air. Experiments on various burner port geometries and temperatures suggest that this is not due to air entrainment at the flame base but to diffusion from zones closer to the flame. Next, quenching surfaces such as grids, perforated plates and flame trap matrices of different metals are progressively lowered into the flame. To avoid flow line distortion, suction aspirates the quenched products. The highest emission rate occurs with the quenching plane some 4 mm above the burner; further lowering of the quenching surface causes flame extinction. The maximum CO release is close to converting 10% of the CH{sub 4} feed, with some variation with quenching material. Expressing this potential release in terms of, e.g. boiler power, predicts a potentially serious hazard. Results of numerical simulations adequately parallel the experimental sampling profiles and provide insights into local concentrations, as well as the spatially resolved CO flux, which is calculated for a parabolic inlet flow profile. Integration across the stream implies, on the basis of the simulation, a possible tripling of the experimental CO release, were quenching simply to release the local gas composition into the atmosphere. Comparison with experiment suggests some chemical interaction with the quenching surface. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Aero-Thermal Characterization of Accelerating and Diffusing Passages Downstream of Rotating Detonation Combustors

Cycle benefits of rotating detonation engines show up to five percentage points of efficiency gain for low-pressure ratio engines. An optimal integration between the combustor and the turbine needs to be guaranteed to realize this potential gain. The rotating detonation combustor (RDC) exhausts transonic flow with shocks rotating at frequencies ranging from a few to tens of kilohertz depending on the number of present waves. Hence, the turbine design requires precise knowledge of the fluctuations and losses downstream of the combustor. This paper focuses on the quantification of fluctuations and losses for accelerating and diffusing passages. The analysis of the combustor is performed via reactive unsteady Reynolds Averaged Navier-Stokes (URANS) simulations. The unsteady RANS equations are solved via CFD++ from Metacomp with a one-step reaction mechanism for an H2-air mixture. The resolving of the boundary layer is achieved with a structured mesh of around 36 million cells. Inlet pressure of 10 bar and two different back pressures are applied to the combustor to model the interconnection with downstream turbines. Finally, we present and assess a methodology to reduce the computational time to model these passages ten times.

Braun, James↗

Experimental study of low aspect ratio compressor blading

The paper presents a study of low aspect blading for the inlet stages of a high pressure ratio, high-speed core compressor. The basic overall design variables were stage pressure ratio and blade aspect ratio; these four stages represent two levels of total pressure ratio, two levels of rotor blade aspect ratio, and two levels of stator vane aspect ratios. Comparisons of the overall performance, radial distributions of performance parameters, diffusion factors at the near-stall conditions, blade element data, and the axial distribution of rotor tip static pressures yielded the following results: (1) higher peak pressure ratio, high stage and rotor efficiencies, and greater stall margin were obtained with the lower aspect ratio blading, (2) the lower aspect ratio blading showed improved performance over the entire blade span, and (3) the lower aspect ratio rotors operated at higher diffusion factors and higher incidence angles over the entire blade span.

Reid, L.↗

Experimental Investigation of a High Pressure Ratio Aspirated Fan Stage

The experimental investigation of an aspirated fan stage designed to achieve a pressure ratio of 3.4:1 at 1500 ft/sec is presented in this paper. The low-energy viscous flow is aspirated from diffusion-limiting locations on the blades and flowpath surfaces of the stage, enabling a very high pressure ratio to be achieved in a single stage. The fan stage performance was mapped at various operating speeds from choke to stall in a compressor facility at fully simulated engine conditions. The experimentally determined stage performance, in terms of pressure ratio and corresponding inlet mass flow rate, was found to be in good agreement with the three-dimensional viscous computational prediction, and in turn close to the design intent. Stage pressure ratios exceeding 3:1 were achieved at design speed, with an aspiration flow fraction of 3.5 percent of the stage inlet mass flow. The experimental performance of the stage at various operating conditions, including detailed flowfield measurements, are presented and discussed in the context of the computational analyses. The sensitivity of the stage performance and operability to reduced aspiration flow rates at design and off design conditions are also discussed.

Merchant, Ali↗

Water and Solute Activities Regulate CO 2 Reduction in Gas-Diffusion Electrodes

Electrolysis of CO 2 at gas-diffusion electrodes (GDEs) has typically been limited by the supply of gas to the electrocatalyst, overshadowing the importance of the supply of water. However, at high current densities that approach 1 A cm –2 , where the electrolyte becomes highly concentrated in the catalyst layer of a GDE, the activity of water and solutes deviate from their bulk dilute solution values, potentially slowing reaction rates and changing reaction equilibrium potentials. In addition, as flow plates for the gas stream are introduced to enable larger electrodes and high single pass conversion of CO 2 to product, variations in the gas composition will become important. By drawing upon literature for the oxygen reduction reaction (ORR), here we explain how to account for these effects in future modeling and experimental work, with particular attention to accurate use of the Nernst equation for electrode potentials and the Arrhenius equation for reaction rates. Specifically, using measurements of KOH solvent and solute activity reported in literature, and assuming the second protonation of CO 2 by water as the rate-determining step, we show the Nernst equation dilute-solution approximation of the CO 2 to CO equilibrium potential to be accurate below 5 M KOH, but it has a 74 mV error when increasing the concentration up to 10 M KOH. Finally, a simple one-dimensional model of a serpentine flow-field on a GDE demonstrated that a reactor with constant pressure of 1 bar and 1 A cm –2 at the inlet had only ~0.3 A cm –2 at the outlet for a conversion in CO 2 partial pressure from 0.90 to 0.48 bar, showing the significant practical implications of this work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of variable two-dimensional inlet designed for engine-inlet matching I : performance at design Mach number of 3.07

The inlet was investigated with both a two-oblique-shock and an isentropic compression ramp. Provisions for a variety of bypass systems were incorporated and none decreased pressure recovery by more than about 1 percent. By utilizing throat boundary-layer control, critical pressure recoveries of 64 and 70 percent were obtained with the two-shock and isentropic ramps, respectively. Diffuser-exit air distortion was about 5 percent at critical operation Theoretical cowl pressure drag was equal to about 10 percent of the net thrust of an assumed engine.

Beheim, M A↗

Influence of oscillation-induced diffusion on heat transfer in a uniformly heated channel

An analysis of the effect of flow oscillations on laminar flow heat transfer in a channel with uniform heat addition is presented. It is shown that the effect of flow oscillations will be to reduce the channel heat transfer coefficient. This effect is due to the fact that the heat addition along the channel wall produces an increasing fluid temperature along the channel length. The flow oscillations interacting with this positive temperature gradient will induce a heat flow back toward the channel inlet. This will tend to inhibit the heat transfer process and will raise the wall temperature required to transfer away a given amount of heat at the channel wall.

Siegel, R.↗

Designing optimal core–shell MOFs for direct air capture

Metal–organic frameworks (MOFs), along with other novel adsorbents, are frequently proposed as candidate materials to selectively adsorb CO 2 for carbon capture processes. However, adsorbents designed to strongly bind CO 2 nearly always bind H 2 O strongly (sometimes even more so). Given that water is present in significant quantities in the inlet streams of most carbon capture processes, a method that avoids H 2 O competition for the CO 2 binding sites would be technologically valuable. Here, in this paper, we consider a novel core–shell MOF design strategy, where a high-CO 2 -capacity MOF “core” is protected from competitive H 2 O-binding via a MOF “shell” that has very slow water diffusion. We consider a high-frequency adsorption/desorption cycle that regenerates the adsorbents before water can pass through the shell and enter the core. To identify optimal core–shell MOF pairs, we use a combination of experimental measurements, computational modeling, and multiphysics modeling. Our library of MOFs is created from two starting MOFs-UiO-66 and UiO-67-augmented with 30 possible functional group variations, yielding 1740 possible core–shell MOF pairs. After defining a performance score to rank these pairs, we identified 10 core–shell MOF candidates that significantly outperform any of the MOFs functioning alone.

42 ENGINEERING↗

A General Study of Counterflow Diffusion Flames for Supercritical CO2 Combustion

Abstract A counterflow diffusion flame for supercritical CO2 combustion is investigated at various CO2 dilution levels and pressures by accounting for real gas effects into both thermal and transport properties. The UCF 1.1 24-species mechanism is used to account the chemistry. The nature of important nonpremixed combustion characteristics such as Prandtl number, thermal diffusivity, Lewis number, stoichiometric scalar dissipation rate, flame thickness, and Damköhler number are investigated with respect to CO2 dilution and pressure. The results show that the aforementioned parameters are influenced by both dilution and pressure; the dilution effect is more dominant. Further, the result shows that Prandtl number increases with CO2 dilution and at 90% CO2 dilution, the difference between the Prandtl number of the inlet jets and the flame is minimal. Also, the common assumption of unity Lewis number in the theory and modeling of nonpremixed combustion does not hold reasonable for sCO2 applications due to large difference of Lewis number across the flame and the Lewis number on the flame drop significantly with an increase in the CO2 dilution. An interesting relation between Lewis number and CO2 dilution is observed. The Lewis number of species drops by 15% when increasing the CO2 dilution by 30%. Increasing the CO2 dilution increases both the flow and chemical timescales; however, chemical timescale increases faster than the flow timescales. The magnitudes of the Damköhler number signify the need to consider finite rate chemistry for sCO2 applications. Further, the Damköhler numbers at 90% sCO2 dilution are very small; hence, laminar flamelet assumptions in turbulent combustion simulations are not physically correct for this application. Also, it is observed that the Damköhler number drops nonlinearly with increasing CO2 dilution in the oxidizer stream. This is a very important observation for the operation of sCO2 combustors. Further, the flame thickness is found to increase with CO2 dilution and reduce with pressure.

Engineering↗

Flow quality studies of the NASA Lewis Research Center Icing Research Tunnel

A series of studies have been conducted to determine the flow quality in the NASA Lewis Icing Research Tunnel. The primary purpose of these studies was to document airflow characteristics, including flow angularity, in the test section and tunnel loop. A vertically mounted rake was used to survey total and static pressure and two components of flow angle at three axial stations within the test section (test section inlet, test plane, and test section exit; 15 survey stations total). This information will be used to develop methods of improving the aerodynamic and icing characteristics within the test section. The data from surveys made in the tunnel loop were used to determine areas where overall tunnel flow quality and efficiency can be improved. A separate report documents similar flow quality surveys conducted in the diffuser section of the Icing Research Tunnel. The flow quality studies were conducted at several locations around the tunnel loop. Pressure, velocity, and flow angularity measurements were made by using both fixed and translating probes. Although surveys were made throughout the tunnel loop, emphasis was placed on the test section and tunnel areas directly upstream of the test section (settling chamber, bellmouth, and cooler). Flow visualization, by video recording smoke and tuft patterns, was also used during these studies. A great deal of flow visualization work was conducted in the area of the drive fan. Information gathered there will be used to improve the flow quality upstream and downstream of the fan.

Arrington, E. Allen↗

Experimental study of the thermal-acoustic efficiency in a long turbulent diffusion-flame burner

An acoustic source/propagation model is used to interpret measured noise spectra from a long turbulent burner. The acoustic model is based on the perturbation solution of the equations describing the unsteady one-dimensional flow of an inviscid ideal gas with a distributed heat source. The model assumes that the measured noise spectra are due uniquely to the unsteady component of combustion heat release. The model was applied to a long cylindrical hydrogen burner operating over a range of power levels between 4.5 kW and 22.3 kW. Acoustic impedances at the inlet to the burner and at the exit of the tube downstream of the burner were measured and are used as boundary conditions for the model. These measured impedances are also presented.

Mahan, J. R.↗

Interactions of nickel/zirconia solid oxide fuel cell anodes with coal gas containing arsenic

The performance of anode-supported and electrolyte-supported solid oxide fuel cells was investigated in synthetic coal gas containing 0 to 10 ppm arsenic introduced as arsine. Arsenic was found to interact strongly with nickel in the anode, resulting in the formation of nickel-arsenic solid solution, Ni5As2 and Ni11As8, depending on temperature, arsenic concentration, and reaction time. For anode-supported cells, loss of electrical connectivity in the anode support was the principal mode of degradation, as nickel was converted to nickel arsenide phases that migrated to the surface to form large grains. Cell failure occurred well before the entire anode was converted to nickel arsenide, and followed a reciprocal square root of arsenic partial pressure dependence consistent with a diffusion-based rate-limiting step. Failure occurred more quickly with electrolyte-supported cells, which have a substantially smaller nickel inventory. For these cells, time to failure varied linearly with the reciprocal arsenic concentration in coal gas, and occurred when arsenic reached the anode/electrolyte interface. Test performed with nickel/zirconia coupons showed that arsenic was essentially completely captured in a narrow band near the fuel gas inlet.

Environmental Molecular Sciences Laboratory↗

A study of the compressible flow through a diffusing S-duct

Benchmark aerodynamic data are presented for compressible flow through a representative S-duct configuration. A numerical prediction of the S-duct flow field, obtained from a subsonic parabolized Navier-Stokes algorithm, is also shown. The experimental and numerical results are compared. Measurements of the three-dimensional velocity field, total pressures, and static pressures were obtained at five cross-sectional planes. Aerodynamic data were gathered with calibrated pneumatic probes. Surface static pressure and surface flow visualization data were also acquired. All reported tests were conducted with an inlet centerline Mach number of 0.6. The Reynolds number, based on the inlet centerline velocity and duct inlet diameter, was 2.6 x 10(exp 6). Thin inlet turbulent boundary layers existed. The collected data should be beneficial to aircraft inlet designers and the measurements are suitable for the validation of computational codes. The results show that a region of streamwise flow separation occurred within the duct. Details about the separated flow region, including mechanisms which drive this complicated flow phenomenon, are discussed. Results also indicate that the duct curvature induces strong pressure driven secondary flows. The cross flows evolve into counter-rotating vortices. These vortices convect low momentum fluid of the boundary layer toward the center of the duct, degrading both the uniformity and magnitude of the total pressure profile.

Wellborn, Steven R.↗

Gas phase hydrogen permeation in alpha titanium and carbon steels

Commercially pure titanium and heats of Armco ingot iron and steels containing from 0.008-1.23 w/oC were annealed or normalized and machined into hollow cylinders. Coefficients of diffusion for alpha-Ti and alpha-Fe were determined by the lag-time technique. Steady state permeation experiments yield first power pressure dependence for alpha-Ti and Sievert's law square root dependence for Armco iron and carbon steels. As in the case of diffusion, permeation data confirm that alpha-titanium is subject to at least partial phase boundary reaction control while the steels are purely diffusion controlled. The permeation rate in steels also decreases as the carbon content increases. As a consequence of Sievert's law, the computed hydrogen solubility decreases as the carbon content increases. This decreases in explained in terms of hydrogen trapping at carbide interfaces. Oxidizing and nitriding the surfaces of alpha-titanium membranes result in a decrease in the permeation rate for such treatment on the gas inlet surfaces but resulted in a slight increase in the rate for such treatment on the gas outlet surfaces. This is explained in terms of a discontinuous TiH2 layer.

Johnson, D. L.↗

DNB evaluation of PWR steam-line break event using Westinghouse and CASL coupled code systems

ANCKVIPRE and the VERA-CS code systems have been successfully applied to predicting PWR core response with respect to departure from nucleate boiling (DNB) at the limiting time step of a postulated hot zero power (HZP) main steam-line break (MSLB) event with and without offsite power available. ANCKVIPRE links the ANC code with the VIPRE-W code. ANC is Westinghouse's multi-dimensional nodal diffusion code for all nuclear core design calculations. It predicts core reactivity, assembly power, rod power, detector thimble flux, and other relevant core characteristics. VIPRE-W is the Westinghouse version of a thermalhydraulic subchannel code developed for light water reactor core design applications. The reactor core simulation was based on input of the core boundary conditions from RETRAN system transient and STAR-CCM+ CFD core inlet distribution calculations. To account for the asymmetric power distribution in the reactor core due to the broken steam pipe in one loop and the stuck RCCA, both ANCKVIPRE and the VERA-CS models were set up for the whole reactor core. The advanced modeling and simulations confirmed that the HZP MSLB high-flow case with offsite power available is more limiting with respect to the DNB acceptance criterion, consistent with the limiting case analyzed in the 4-loop plant Safety Analysis Report (SAR). The results also demonstrated that the currently NRC-approved Westinghouse coupled code system such as ANCKVIPRE remains conservative.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗