Search NASA⌕ Search

SEARCH · Search NASA

Results for “Kinetics Parameters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Selective Chemical Looping Combustion of Terminal Alkynes in Mixtures with Alkenes

The selective combustion of terminal alkynes in mixtures with alkenes is demonstrated during anaerobic reduction half-cycles on bulk bismuth oxide (Bi 2 O 3 ) as an approach to remove alkynes, which act as inhibitors in olefin polymerization. Bi 2 O 3 combusts phenylacetylene in styrene, 3-methylphenylacetylene in 3-methylstyrene, propyne in propylene, 1-hexyne in 1-hexene, and 1-octyne in 1-octene, with alkyne combustion selectivities exceeding 96%. Near unity reaction orders for hydrocarbon consumption during reduction half-cycles are consistent with combustion pathways initiated by rate-determining initial C–H activation, which drive selective alkyne combustion through intrinsic differences in the first-order rate constants for alkyne and alkene combustion rather than preferential adsorption of alkynes on Bi 2 O 3 surfaces. Computational assessments of initial C–H activation pathways for alkynes and alkenes on (010) α-Bi 2 O 3 surfaces using density functional theory illustrate that heterolytic transition states which form proton-carbanion pairs on Bi–O sites kinetically favor the activation of alkynes rather than alkenes due to differences in C–H bond acidity, and the barrier for heterolytic C–H activation is dictated in part by the sum of the molecular deprotonation energy and the energy to bind an R – carbanion to a Bi site in its transition-state geometry. Finally, these heterolytic reactivity channels during selective chemical looping combustion present novel routes for purifying olefin gas streams containing alkyne impurities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum Effects on H 2 Diffusion in Zeolite RHO: Inverse Kinetic Isotope Effect for Sieving

We use canonical variational theory (CVT) with small-curvature tunneling (SCT) contributions to investigate quantum effects on the H 2 diffusion process in the pure-silica zeolite RHO. At low temperature we find an inverse kinetic isotopic sieving effect in that the heavier isotopic species diffuses faster than the lighter one. Three quantum effects contribute to this kinetic isotope effect (KIE). The first one is quantum mechanical tunneling; this—on its own—would lead to a normal kinetic isotopic sieving effect, in which lighter diprotium diffuses faster than dideuterium. The second factor, which we find to dominate in the present case, is zero-point energy (ZPE). Deuterium has a lower ZPE, which leads to a smaller effective barrier for tunneling because the transition state has a larger ZPE than the precursor stable state; this results in an inverse KIE. The third factor, the thermal vibrational energy (computed from the quantized vibrational partition function), also favors a normal KIE, but it is outweighed by the ZPE effect. The vibrations of the zeolite host framework are found to play an important role at low temperatures, and our calculations consider up to 7296 degrees of freedom at the equilibrium structure and the saddle point and up to 221 degrees of freedom along the reaction path. In conclusion, the importance of quantum considerations on the dynamics is elucidated by comparison to a purely classical treatment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced Menshutkin S N 2 Reactivity in Mesoporous Silica: The Influence of Surface Catalysis and Confinement

A significant enhancement in the Menshutkin S N 2 reaction between 1-methylimidazole (MeIm) and methyl thiocyanate (MeSCN) is observed when the reaction is confined in the nanoscale silica pores of MCM41 and SBA15. The experiments in the silica pores are conducted without surrounding bulk reaction mixture. The influences of temperature, pore radius, and surface chemistry on the kinetics of the confined reaction are analyzed with time-dependent infrared spectroscopy, molecular dynamics simulations, and ab initio calculations. The rate constant of the pseudo-first order reaction increases with decreasing pore size, and the activation energy is found to decrease by 5.6 kJ/mol in the smallest pore studied (2.8 nm) relative to the bulk reaction. The rate constant dependence on pore size is accurately described by a two-state model in which molecules within the 4.6 Å interfacial layer experience a 2.4-fold rate constant increase relative to those reacting at the bulk rate further away from the interface. The removal of polar silanol groups from the silica surface via passivation with trimethylsilyl chloride results in bulk-like kinetics despite a reduction in the pore diameter, demonstrating the role of silanols as catalytic sites. Here, electronic structure calculations of the energy profile on a model silica surface confirm that silanol groups, particularly those of the vicinal type, can reduce the activation energy and reaction endothermicity through the donation of hydrogen bonds to the reactant, transition state, and product complexes.

36 MATERIALS SCIENCE↗

Mechanistic model for stresses in the oxide layer formed on zirconium alloys

Zirconium alloys are widely used as the cladding material in pressurized-water-reactors. The oxide formed is subjected to compressive stresses, which relax over time. This may affect the protectiveness of the oxide layer by allowing crack formation. We present a mechanistic model to predict these stresses as a function of temperature and oxidation kinetics. Material parameters for elastic deformation, creep, and thermal expansion are taken from appropriate experimental studies and the resulting predictions for the evolution of the stress distributions are compared with other experimental data. Lastly, dislocation glide in the oxide is found to be the dominant mechanism of stress relaxation for temperatures below 900 K.

99 GENERAL AND MISCELLANEOUS↗

Cosmological constraints on decoupled dark photons and dark Higgs

Any neutral boson such as a dark photon or dark Higgs that is part of a non-standard sector of particles can mix with its standard model counterpart. When very weakly mixed with the Standard Model, these particles are produced in the early Universe via the freeze-in mechanism and subsequently decay back to standard model particles. In this work, we place constraints on such mediator decays by considering bounds from Big Bang nucleosynthesis and the cosmic microwave background radiation. We find both nucleosynthesis and CMB can constrain dark photons with a kinetic mixing parameter between log ϵ∼−10 to −17 for masses between 1 MeV and 100 GeV. Similarly, the dark Higgs mixing angle ϵ with the Standard Model Higgs is constrained between log ϵ∼−6 to −15. Dramatic improvement on the bounds from CMB spectral distortions can be achieved with proposed experiments such as PIXIE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for a Dark Higgs Boson Produced in Association with Inelastic Dark Matter at the Belle II Experiment

Inelastic dark matter models that have two dark matter particles and a massive dark photon can reproduce the observed relic dark matter density without violating cosmological limits. The mass splitting between the two dark matter particles 𝜒 1 and 𝜒 2 , with 𝑚⁡(𝜒 2 ) >𝑚⁡(𝜒 1 ), is induced by a dark Higgs field and a corresponding dark Higgs boson ℎ′. We present a search for dark matter in events with two vertices, at least one of which must be displaced from the interaction region, and missing energy. Using a 365 fb −1 data sample collected at Belle II, which operates at the SuperKEKB 𝑒 + ⁢𝑒 − collider, we observe no evidence for a signal. We set upper limits on the product of the production cross section 𝜎⁡(𝑒 + ⁢𝑒 − → ℎ′⁡𝜒 1 ⁢𝜒 2 ), and the product of branching fractions ℬ⁡(𝜒 2 → 𝜒 1⁢ 𝑒 + ⁢𝑒 − ) ×ℬ⁡(ℎ′ → 𝑥 + ⁢𝑥 − ), where 𝑥 + ⁢𝑥 − indicates 𝜇 + ⁢𝜇 − , 𝜋 + ⁢𝜋 − , or 𝐾 + ⁢𝐾 − , as functions of ℎ′ mass and lifetime at the level of 10 −1 fb. We set model-dependent upper limits on the dark Higgs mixing angle at the level of 10 −5 and on the dark photon kinetic mixing parameter at the level of 10 −3 . This is the first search for dark Higgs bosons in association with inelastic dark matter.

dark matter↗

Pion, kaon, and (anti)proton production in $\cup + \cup$ collisions at $\sqrt{s_{NN}} = 193$ GeV measured with the STAR detector

We present the first measurements of transverse momentum spectra of $π^±, K^±, p(\overline{p})$ at midrapidity ($|y|$ < 0.1) in $\cup + \cup$ collisions at $\sqrt{s_{NN}} = 193$ GeV with the STAR detector at the Relativistic Heavy Ion Collider (RHIC). The centrality dependence of particle yields, average transverse momenta, particle ratios and kinetic freezeout parameters are discussed. The results are compared with the published results from Au+Au collisions at $\sqrt{s_{NN}} = 200$ GeV in STAR. The results are also compared to those from A Multi Phase Transport (AMPT) model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector

This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axionlike particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 g Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 g-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section σ ¯ e is constrained for dark matter masses from 0.5 to 10 4 MeV / c 2 ; in the mass range from 1.2 to 50 eV / c 2 the dark photon kinetic mixing parameter ϵ and the axioelectric coupling constant g a e are constrained. The minimum 90% confidence-level upper limits within the above-mentioned mass ranges are σ ¯ e = 8.7 × 10 - 34 cm 2 , ϵ = 3.3 × 10 - 14 , and g a e = 1.0 × 10 - 9 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting boosted dark photons with gaseous detectors

We search for indirect signals of O ( keV ) dark matter annihilating or decaying into O ( eV ) dark photons. These dark photons will be highly boosted, predominantly transversely polarized, have decay lengths larger than the Milky Way, and can be absorbed by neutrino or dark matter experiments at a rate dependent on the photon-dark photon kinetic mixing parameter and the optical properties of the experiment. We show that current experiments cannot probe new parameter space, but future large-scale gaseous detectors with low backgrounds (i.e., CYGNUS, NEXT, PANDAX-III) may be sensitive to this signal when the annihilation cross section is especially large. Published by the American Physical Society 2024

79 ASTRONOMY AND ASTROPHYSICS↗

First Direct-Detection Constraints on eV-Scale Hidden-Photon Dark Matter with DAMIC at SNOLAB

Here, we present direct detection constraints on the absorption of hidden-photon dark matter with particle masses in the range 1.2-30 eV$c^{-2}$ with the DAMIC experiment at SNOLAB. Under the assumption that the local dark matter is entirely constituted of hidden photons, the sensitivity to the kinetic mixing parameter $\kappa$ is competitive with constraints from solar emission, reaching a minimum value of 2.2$\times$$10^{-14}$ at 17 eV$c^{-2}$. These results are the most stringent direct detection constraints on hidden-photon dark matter with masses 3-12 eV$c^{-2}$ and the first demonstration of direct experimental sensitivity to ionization signals $<$12 eV from dark matter interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark Photon Limits from Patchy Dark Screening of the Cosmic Microwave Background

Dark photons that kinetically mix with the Standard Model photon give rise to new spectral anisotropies (patchy dark screening) in the cosmic microwave background (CMB) due to conversion of photons to dark photons within large-scale structure. We utilize predictions for this patchy dark screening signal to provide the tightest constraints to date on the dark photon kinetic mixing parameter [ ϵ ≲ 4.5 × 10 − 8 (95% confidence level)] over the mass range 10 − 13 eV ≲ m A ′ ≲ 10 − 11 eV , almost an order of magnitude stronger than previous limits, by applying state-of-the-art component separation techniques to the cross-correlation of CMB and unWISE galaxy survey data. Published by the American Physical Society 2024

McCarthy, Fiona (ORCID:0000000253893565)↗

Testing thermal-relic dark matter with a dark-photon mediator

In light of recent DAMIC-M results, we present the status of thermal-relic dark matter χ coupled to a kinetically mixed dark photon A ′ . In the predictive “direct annihilation” regime, m A ′ > m χ , the relic abundance depends on the kinetic mixing parameter, and there is a minimum value compatible with thermal freeze-out. Using only electron- and nuclear-recoil direct-detection results, we find that, for complex scalar dark matter, the direct annihilation regime is now excluded for nearly all values of m χ ; the only exception is the resonant annihilation regime where m A ′ ≈ 2 m χ . Direct annihilation relic targets for other representative models, including Majorana and pseudo-Dirac candidates, remain viable across a wide range of model parameters but will be tested with a combination of dedicated accelerator searches in the near future. In the opposite “secluded annihilation” regime, where m χ > m A ′ , this scenario is excluded by cosmic microwave background measurements for all m χ ≲ 30 GeV . Similar conclusions in both the direct and secluded regimes hold for all anomaly-free vector mediators that couple to the first generation of electrically charged Standard Model particles.

Krnjaic, Gordan [Fermilab; Chicago U., KICP] (ORCI↗

Piezoelectric bulk acoustic resonators for dark photon detection

The kinetically mixed dark photon is a simple, testable dark matter candidate with strong theoretical motivation. Detecting the feeble electric field dark photon dark matter produces requires extremely sensitive detectors. Bulk acoustic resonators (BARs), with their exceptionally high-quality phonon modes, are highly sensitive detectors, and have previously leveraged this sensitivity to search for gravitational waves in the MHz to GHz frequency range. The BAR phonons are typically read out by detecting the electric field generated by the BAR materials’ piezoelectricity. Here we show that this piezoelectricity also rewards such detectors sensitivity to dark photon dark matter, as the dark electric field can resonantly excite BAR phonons. A single 10 g piezoelectric BAR in a large, cold, environment can be orders of magnitude more sensitive to the kinetic mixing parameter than any current experiment, with only a month-long exposure and thermally limited backgrounds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of in vivo quantification accuracy of the Ingenuity-TF PET/MR

Purpose: The quantitative accuracy of standardized uptake values (SUVs) and tracer kinetic uptake parameters in patient investigations strongly depends on accurate determination of regional activity concentrations in positron emission tomography (PET) data. This determination rests on the assumption that the given scanner calibration is valid in vivo. In a previous study, we introduced a method to test this assumption. This method allows to identify discrepancies in quantitative accuracy in vivo by comparison of activity concentrations of urine samples measured in a well-counter with activity concentrations extracted from PET images of the bladder. In the present study, we have applied this method to the Philips Ingenuity-TF PET/MR since at the present stage, absolute quantitative accuracy of combined PET/MR systems is still under investigation. Methods: Twenty one clinical whole-body F18-FDG scans were included in this study. The bladder region was imaged as the last bed position and urine samples were collected afterward. PET images were reconstructed including MR-based attenuation correction with and without truncation compensation and 3D regions-of-interest (ROIs) of the bladder were delineated by three observers. To exclude partial volume effects, ROIs were concentrically shrunk by 8–10 mm. Then, activity concentrations were determined in the PET images for the bladder and for the urine by measuring the samples in a calibrated well-counter. In addition, linearity measurements of SUV vs singles rate and measurements of the stability of the coincidence rate of “true” events of the PET/MR system were performed over a period of 4 months. Results: The measured in vivo activity concentrations were significantly lower in PET/MR than in the well-counter with a ratio of the former to the latter of 0.756 ± 0.060 (mean ± std. dev.), a range of 0.604–0.858, and a P value of 3.9 ⋅ 10{sup −14}. While the stability measurements of the coincidence rate of “true” events showed no relevant deviation over time, the linearity scans revealed a systematic error of 8%–11% (avg. 9%) for the range of singles rates present in the bladder scans. After correcting for this systematic bias caused by shortcomings of the manufacturers calibration procedure, the PET to well-counter ratio increased to 0.832 ± 0.064 (0.668 –0.941), P = 1.1 ⋅ 10{sup −10}. After compensating for truncation of the upper extremities in the MR-based attenuation maps, the ratio further improved to 0.871 ± 0.069 (0.693–0.992), P = 3.9 ⋅ 10{sup −8}. Conclusions: Our results show that the Philips PET/MR underestimates activity concentrations in the bladder by 17%, which is 7 percentage points (pp.) larger than in the previously investigated PET and PET/CT systems. We attribute this increased underestimation to remaining limitations of the MR-based attenuation correction. Our results suggest that only a 2 pp. larger underestimation of activity concentrations compared to PET/CT can be observed if compensation of attenuation truncation of the upper extremities is applied. Thus, quantification accuracy of the Philips Ingenuity-TF PET/MR can be considered acceptable for clinical purposes given the ±10% error margin in the EANM guidelines. The comparison of PET images from the bladder region with urine samples has proven a useful method. It might be interesting for evaluation and comparison of the in vivo quantitative accuracy of PET, PET/CT, and especially PET/MR systems from different manufacturers or in multicenter trials.

60 APPLIED LIFE SCIENCES↗

Cosmological Constraints on Decoupled Dark Photons and Dark Higgs

Any neutral boson such as a dark photon or dark Higgs that is part of a non-standard sector of particles can mix with its standard model counterpart. When very weakly mixed with the Standard Model, these particles are produced in the early Universe via the freeze-in mechanism and subsequently decay back to standard model particles. In this work, we place constraints on such mediator decays by considering bounds from Big Bang nucleosynthesis and the cosmic microwave background radiation. We find both nucleosynthesis and CMB can constrain dark photons with a kinetic mixing parameter between log ϵ ~ -10 to -17 for masses between 1 MeV and 100 GeV. Similarly, the dark Higgs mixing angle ϵ with the Standard Model Higgs is constrained between log ϵ ~ -6 to -15. Dramatic improvement on the bounds from CMB spectral distortions can be achieved with proposed experiments such as PIXIE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Toward non-Si electronics: From remote epitaxy to layer splitting of 2D materials for mixed dimensional heterostructures

The current electronics has been mainly dominated by Si-based devices due to their mature processing system and exceptional cost-effectiveness. However, next generation electronics needs novel functionalities that cannot be realized by Si because of intrinsic limitation of Si. Accordingly, demand for non-Si electronics has been getting substantially high. Unfortunately, current methodology requires extremely high cost for non-Si materials, which impedes the progress in developing the non-Si based electronics. Here, I will discuss about our group’s efforts to address this issue. Our team recently conceived a new crystalline growth, termed as “remote epitaxy”, which can copy/paste crystalline information from substrates remotely through graphene, thus generating single-crystalline films on graphene. As interfacial binding energy is attenuated by inserting graphene at interface, the single-crystalline films can be easily exfoliated from the slippery graphene surface. Also, the graphene-coated substrates can be, in principle, reused infinitely to produce single-crystalline films. Thus, the remote epitaxy can produce non-Si semiconductor films with unprecedented cost efficiency while allowing additional flexible device functionality required for current ubiquitous electronics. Next, I will discuss about a layer splitting technique which can be a potential solution to overcome the problem in obtaining large-scale and monolayer 2D materials. A 2D material-based heterostructure has been intensively studied because of its unique device functionalities and novel physics. However, it is extremely challenging to secure large-scale and monolayer 2D materials because of following issues: 1) poor scalability for laboratory fabrication processes of 2D heterostructures and 2) lack of well-defined control parameters for kinetics of 2D materials and predictable number of layers of 2D materials. To resolve this issue, we conceived a new approach called “layer-resolved splitting” which obtains multiple monolayer from multilayer 2D materials by controlling interfacial toughness contrast. As this method is versatile and universal, we can, in principle, apply to all 2D materials. We succeeded in having large-scale, monolayer 2D materials through our approach and, thereby 2D heterostructures were demonstrated for functional devices. Lastly, I would like to discuss opportunities of mixed-dimensional heterostructure demonstrated by remote epitaxy and layer-resolved splitting. As they produce freestanding 3D bulk films and 2D atomic layers, a new type of 3D/2D heterostructures can be realized where a new physics and new device architecture are revealed. Therefore, I believe that a new opportunity will be discovered through the mixed-dimensional heterostructures.

Bae, Sang-Hoon↗