Search NASA⌕ Search

SEARCH · Search NASA

Results for “LINAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

The Soft X-ray research instrument at the Linac Coherent Light Source

The Soft X-ray Research instrument provides intense ultrashort X-ray pulses in the energy range 280–2000 eV. A diverse set of experimental stations may be installed to investigate a broad range of scientific topics such as ultrafast chemistry, highly correlated materials, magnetism, surface science, and matter under extreme conditions. A brief description of the main instrument components will be given, followed by some selected scientific highlights.

43 PARTICLE ACCELERATORS↗

The Coherent X-ray Imaging instrument at the Linac Coherent Light Source

The Coherent X-ray Imaging (CXI) instrument specializes in hard X-ray, in-vacuum, high power density experiments in all areas of science. Two main sample chambers, one containing a 100 nm focus and one a 1 µm focus, are available, each with multiple diagnostics, sample injection, pump–probe and detector capabilities. The flexibility of CXI has enabled it to host a diverse range of experiments, from biological to extreme matter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The matter in extreme conditions instrument at the Linac Coherent Light Source

The LCLS beam provides revolutionary capabilities for studying the transient behavior of matter in extreme conditions. The particular strength of the Matter in Extreme Conditions instrument is that it combines the unique LCLS beam with high-power optical laser beams, and a suite of dedicated diagnostics tailored for this field of science. In this paper an overview of the beamline, the capabilities of the instrumentation, and selected highlights of experiments and commissioning results are presented.

43 PARTICLE ACCELERATORS↗

The X-ray Pump–Probe instrument at the Linac Coherent Light Source

The X-ray Pump–Probe instrument achieves femtosecond time-resolution with hard X-ray methods using a free-electron laser source. It covers a photon energy range of 4–24 keV. A femtosecond optical laser system is available across a broad spectrum of wavelengths for generating transient states of matter. The instrument is designed to emphasize versatility and the scientific goals encompass ultrafast physical, chemical and biological processes involved in the transformation of matter and transfer of energy at the atomic scale.

43 PARTICLE ACCELERATORS↗

Measurement of the absolute number of photons of the hard X-ray beamline at the Linac Coherent Light Source

X-ray free-electron lasers provide intense pulses of coherent X-rays with a short pulse duration. These sources are chaotic by nature and therefore, to be used at their full potential, require that every X-ray pulse is characterized in terms of various relevant properties such as intensity, photon energy, position and timing. Diagnostics are for example installed on an X-ray beamline to specifically monitor the intensity of individual X-ray pulses. To date, these can however only provide a single-shot value of the relative number of photons per shot. Here are reported measurements made in January 2015 of the absolute number of photons in the hard X-ray regime at LCLS which is typically 3.5 × 10 11 photons shot –1 between 6 and 9.5 keV at the X-ray Pump–Probe instrument. Moreover, an average transmission of ≈62% of the hard X-ray beamline over this energy range is measured and the third-harmonic content of ≈0.47% below 9 keV is characterized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The time-resolved atomic, molecular and optical science instrument at the Linac Coherent Light Source

The newly constructed time-resolved atomic, molecular and optical science instrument (TMO) is configured to take full advantage of both linear accelerators at SLAC National Accelerator Laboratory, the copper accelerator operating at a repetition rate of 120 Hz providing high per-pulse energy as well as the superconducting accelerator operating at a repetition rate of about 1 MHz providing high average intensity. Both accelerators power a soft X-ray free-electron laser with the new variable-gap undulator section. With this flexible light source, TMO supports many experimental techniques not previously available at LCLS and will have two X-ray beam focus spots in line. Thereby, TMO supports atomic, molecular and optical, strong-field and nonlinear science and will also host a designated new dynamic reaction microscope with a sub-micrometer X-ray focus spot. The flexible instrument design is optimized for studying ultrafast electronic and molecular phenomena and can take full advantage of the sub-femtosecond soft X-ray pulse generation program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ALTERNATIVE CONFIGURATION AND TIMING CONTROL FOR BEAM CHOPPING SYSTEM AT THE SNS LINAC

The Spallation Neutron Source (SNS) beam chopping system uses a segmented electrostatic lens in the Low Energy Beam Transport (LEBT) line to deflect the beam out of the Radio Frequency Quadrupole (RFQ) input aperture to create gaps in the 1 ms beam macro-pulse for extraction from the Ring, or fully displace the beam. The lens is split azimuthally into four quadrants which are pulsed independently by four bipolar high voltage pulse generators. The chopper timing control system creates trigger pulses to the pulse generators which deflect the beam sequentially to four positions on the chopper target. In the present chopper configuration, all four segments are powered simultaneously with a 1 MHz burst repetition rate within the macro-pulse. To improve chopping performance, faster switches and higher voltages are required. An alternative chopping system configuration which can meet this request has been proposed, where only two opposite segments are used at a time. This will facilitate pulse generator performance by reducing switching frequency and power dissipation in the high voltage switches while operating at increased voltages, and make beam deflection more effective, stable and reliable. The new chopping configuration requires changes in the LEBT timing control patterns, upgrading the pulse generator, and changing the azimuthal position of the lens segments in the LEBT structure.This paper will review the timing control patterns for present and suggested configurations, compare the pulse generator performance for both cases, and show the advantages of the new chopping modes. The results of the simulated beam distribution at the RFQ input for different deflecting voltages will also be presented.

Peplov, Vladimir↗

Improving vacuum performance in the warm linac of the Spallation Neutron Source

The Spallation Neutron Source is an accelerator-based neutron source built and operated by the U.S. Department of Energy in Oak Ridge, Tennessee. With over 10 years of operation at 1 MW of power and above, shortcomings have been identified in the original vacuum pumping scheme for the drift tube and the coupled cavity linear accelerator sections. In this article, the vacuum performance for these systems is reviewed and the major areas of concern are discussed. The changes to the vacuum system are examined and the final design is described. Finally, the performance impact of these changes after a year of operation with the new vacuum system is presented.

47 OTHER INSTRUMENTATION↗

Toward correcting drift in target position during radiotherapy via computer-controlled couch adjustments on a programmable Linac

Purpose: Real-time tracking of respiratory target motion during radiation therapy is technically challenging, owing to rapid and possibly irregular breathing variations. The authors report on a method to predict and correct respiration-averaged drift in target position by means of couch adjustments on an accelerator equipped with such capability. Methods: Dose delivery is broken up into a sequence of 10 s field segments, each followed by a couch adjustment based on analysis of breathing motion from an external monitor as a surrogate of internal target motion. Signal averaging over three respiratory cycles yields a baseline representing target drift. A Kalman filter predicts the baseline position 5 s in advance, for determination of the couch correction. The method's feasibility is tested with a motion phantom programmed according to previously recorded patient signals. Computed couch corrections are preprogrammed into a research mode of an accelerator capable of computer-controlled couch translations synchronized with the motion phantom. The method's performance is evaluated with five cases recorded during hypofractionated treatment and five from respiration-correlated CT simulation, using a root-mean-squared deviation (RMSD) of the baseline from the treatment planned position. Results: RMSD is reduced in all 10 cases, from a mean of 4.9 mm (range 2.7-9.4 mm) before correction to 1.7 mm (range 0.7-2.3 mm) after correction. Treatment time is increased {approx}5% relative to that for no corrections. Conclusions: This work illustrates the potential for reduction in baseline respiratory drift with periodic adjustments in couch position during treatment. Future treatment machine capabilities will enable the use of 'on-the-fly' couch adjustments during treatment.

60 APPLIED LIFE SCIENCES↗

SU-E-T-237: Monte Carlo Dosimetric Characterization of the Mobetron Mobile Linac

Purpose: The aim of this work is to characterize dosimetrically a clinical intraoperative electron beam accelerator, Mobetron (IntraOp Medical, Inc.) in clinical use in our Hospital. Once this first step is completed our purpose is to evaluate shielding requirements for such a device by preparing adequate phase space files. Methods: It is known that electron beam simulation parameters required for state-of-the-art Monte Carlo codes to obtain a good match with measured data, like the mean energy or the FWHM, may not be code-independent due to the different set of process simulated and formalisms involved. Then, to cross-check our results against any issue in the simulation we have compared experimental data (PDD and profiles for electrons in the range 4 to 12 MeV) with simulations performed independently using both Penelope2011 and Geant4 codes. To do so, the geometry and materials of the head of the accelerator have been fully characterized following information provided by the manufacturer. Results: Both simulations agree with experimental data within experimental uncertainties (±1 mm displacement), although small variations (less than 10%) in the mean energy and FWHM are required to match measured values depending on the code used. Conclusion: Independent Monte Carlo simulations were used to obtain an excellent match to measured electron dose distributions. This opens the road to use such data for evaluating shielding requirements which is the main objective of this project.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-250: New IMRT Sequencing Strategy: Towards Intra-Fraction Plan Adaptation for the MR-Linac

Purpose: To develop a new sequencer for IMRT planning that during treatment makes the inclusion of external factors possible and by doing so accounts for intra-fraction anatomy changes. Given a real-time imaging modality that will provide the updated patient anatomy during delivery, this sequencer is able to take these changes into account during the calculation of subsequent segments. Methods: Pencil beams are generated for each beam angle of the treatment and a fluence optimization is performed. The pencil beams, together with the patient anatomy and the above optimal fluence form the input of our algorithm. During each iteration the following steps are performed: A fluence optimization is done and each beam's fluence is then split to discrete intensity levels. Deliverable segments are calculated for each one of these. Each segment's area multiplied by its intensity describes its efficiency. The most efficient segment among all beams is then chosen to deliver a part of the calculated fluence and the dose that will be delivered by this segment is calculated. This delivered dose is then subtracted from the remaining dose. This loop is repeated until 90% of the dose has been delivered and a final segment weight optimization is performed to reach full convergence. Results: This algorithm was tested in several prostate cases yielding results that meet all clinical constraints. Quality assurance was performed on Delta4 and film phantoms for one of these prostate cases and received clinical acceptance after passing both gamma analyses with the 3%/3mm criteria. Conclusion: A new sequencing algorithm was developed to facilitate the needs of intensity modulated treatment. The first results on static anatomy confirm that it can calculate clinical plans equivalent to those of the commercially available planning systems. We are now working towards 100% dose convergence which will allow us to handle anatomy deformations. This work is financially supported by Elekta AB, Stockholm, Sweden.

60 APPLIED LIFE SCIENCES↗

SU-F-BRE-16: VMAT Commissioning and Quality Assurance (QA) of An Elekta Synergy-STM Linac Using ICOM Test HarnessTM

Purpose: To establish a set of tests based on the iCOM software that can be used to commission and perform periodic QA of VMAT delivery on the Elekta Synergy-S, commonly known as the Beam Modulator (BM). Methods: iCOM is used to create and deliver customized treatment fields to characterize the system in terms of 1) MLC positioning accuracy under static and dynamic delivery with full gantry rotation, 2) MLC positioning with known errors, 3) Maximum dose rate, 4) Maximum MLC speed, 5) Maximum gantry speed, 6) Synchronization: gantry speed versus dose rate, and 7) Synchronization: MLC speed versus dose rate. The resulting images were captured on the iView GT and exported in DICOM format to Dosimetry Check™ system for visual and quantitative analysis. For the initial commissioning phase, the system tests described should be supplemented with extensive patient QAs covering all clinically relevant treatment sites. Results: The system performance test suite showed that on our Synergy-S, MLC positioning was accurate under both static and dynamic deliveries. Intentional errors of 1 mm were also easily identified on both static and dynamic picket fence tests. Maximum dose rate was verified with stop watch to be consistently between 475-480 MU/min. Maximum gantry speed and MLC speed were 5.5 degree/s and 2.5 cm/s respectively. After accounting for beam flatness, both synchronization tests, gantry versus dose rate and MLC speed versus dose rate, were successful as the fields were uniform across the strips and there were no obvious cold/hot spots. Conclusion: VMAT commissioning and quality assurance should include machine characterization tests in addition to patient QAs. Elekta iCOM is a valuable tool for the design of customized VMAT field with specific MU, MLC leaf positions, dose rate, and indirect control of MLC and gantry speed at each of its control points.

07 ISOTOPE AND RADIATION SOURCES↗

MO-PIS-Exhibit Hall-01: Tools for TG-142 Linac Imaging QA I

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The therapy topic this year is solutions for TG-142 recommendations for linear accelerator imaging QA. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Automated Imaging QA for TG-142 with RIT Presentation Time: 2:45 – 3:15 PM This presentation will discuss software tools for automated imaging QA and phantom analysis for TG-142. All modalities used in radiation oncology will be discussed, including CBCT, planar kV imaging, planar MV imaging, and imaging and treatment coordinate coincidence. Vendor supplied phantoms as well as a variety of third-party phantoms will be shown, along with appropriate analyses, proper phantom setup procedures and scanning settings, and a discussion of image quality metrics. Tools for process automation will be discussed which include: RIT Cognition (machine learning for phantom image identification), RIT Cerberus (automated file system monitoring and searching), and RunQueueC (batch processing of multiple images). In addition to phantom analysis, tools for statistical tracking, trending, and reporting will be discussed. This discussion will include an introduction to statistical process control, a valuable tool in analyzing data and determining appropriate tolerances. An Introduction to TG-142 Imaging QA Using Standard Imaging Products Presentation Time: 3:15 – 3:45 PM Medical Physicists want to understand the logic behind TG-142 Imaging QA. What is often missing is a firm understanding of the connections between the EPID and OBI phantom imaging, the software “algorithms” that calculate the QA metrics, the establishment of baselines, and the analysis and interpretation of the results. The goal of our brief presentation will be to establish and solidify these connections. Our talk will be motivated by the Standard Imaging, Inc. phantom and software solutions. We will present and explain each of the image quality metrics in TG-142 in terms of the theory, mathematics, and algorithms used to implement them in the Standard Imaging PIPSpro software. In the process, we will identify the regions of phantom images that are analyzed by each algorithm. We then will discuss the process of the creation of baselines and typical ranges of acceptable values for each imaging quality metric.

07 ISOTOPE AND RADIATION SOURCES↗

WE-PIS-Exhibit Hall-01: Tools for TG-142 Linac Imaging QA II

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The therapy topic this year is solutions for TG-142 recommendations for linear accelerator imaging QA. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Using DoseLab to Perform TG-142 Imaging QA The goals of this session will be to present a clinical overview of acquiring images for TG-142 Imaging QA, as well as analyzing and evaluating results using DoseLab software. DoseLab supports planar imaging QA analysis using almost any QA phantom provided by numerous vendors. General advantages and disadvantages of selecting each of these phantoms will be briefly summarized. Best practices for selecting image acquisition parameters will be presented. A demonstration of using DoseLab software to perform a series of TG-142 tests will be performed. We will disuss why DoseLab uses its own set of imaging QA formulas, and why imaging QA measurement values of the same nominal properties will vary between TG- 142 software packages. Because TG-142 does not specify baseline and tolerance values for imaging QA, the presentation will recommend performing the manufacturer's acceptance test procedure to validate the equipment is functioning correctly. Afterwards, results can be obtained using the clinic's selected set of phantoms, image acquisition parameters, and TG-142 software to set proper baseline values. This presentation will highlight the reasons why comparing imaging QA results can be trickier than comparing linear accelerator treatment results and what physicists should keep in mind when comparing imaging QA results for different machines. Physicists are often unsure of the next step when there is an issue discovered during Imaging QA. Therefore, a few common examples of imaging issues and recommended solutions will be discussed. TG-142 Imaging QA Simplified: Lessons From Diagnostic Physics Collaboration There are many commercial options for the performance of imaging quality assurance tests for the linear accelerator imaging systems as required by the AAPM TG-142 report. Imaging quality assurance testing is largely performed by the diagnostic physicist so routine performance of these tests by the practicing oncology physicist can be complicated and confusing given all of the commercially available options. This presentation focuses on the performance of imaging quality assurance testing for linear accelerators using methods similar to that of diagnostic physicists. This presentation will address the ability to perform the required testing without complicated software and explores solutions for the performance of these tests in an efficient manner while still maintaining the ability to ascertain image quality changes that may ultimately affect clinical decisions.

60 APPLIED LIFE SCIENCES↗