Search NASA⌕ Search

SEARCH · Search NASA

Results for “LINEAR FILTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Action: Baseline Channel Model for SCCC-X and DVB-S2X

This paper analyzes the impact to the error performance of very high-order modulations, specifically 256APSK and 128APSK, in the DVB-S2X and SCCC-X proposals due to transmitter distortions, i.e. phase and amplitude imbalance, amplification non-linearities, and phase noise. The receiver is assumed to be a matched filter with angle derotation capabilities. An exact theoretical prediction is developed as well as supporting simulations is provided.

Modulation↗

Applications of Data Assimilation to Analysis of the Ocean on Large Scales

It is commonplace to begin talks on this topic by noting that oceanographic data are too scarce and sparse to provide complete initial and boundary conditions for large-scale ocean models. Even considering the availability of remotely-sensed data such as radar altimetry from the TOPEX and ERS-1 satellites, a glance at a map of available subsurface data should convince most observers that this is still the case. Data are still too sparse for comprehensive treatment of interannual to interdecadal climate change through the use of models, since the new data sets have not been around for very long. In view of the dearth of data, we must note that the overall picture is changing rapidly. Recently, there have been a number of large scale ocean analysis and prediction efforts, some of which now run on an operational or at least quasi-operational basis, most notably the model based analyses of the tropical oceans. These programs are modeled on numerical weather prediction. Aside from the success of the global tide models, assimilation of data in the tropics, in support of prediction and analysis of seasonal to interannual climate change, is probably the area of large scale ocean modeling and data assimilation in which the most progress has been made. Climate change is a problem which is particularly suited to advanced data assimilation methods. Linear models are useful, and the linear theory can be exploited. For the most part, the data are sufficiently sparse that implementation of advanced methods is worthwhile. As an example of a large scale data assimilation experiment with a recent extensive data set, we present results of a tropical ocean experiment in which the Kalman filter was used to assimilate three years of altimetric data from Geosat into a coarsely resolved linearized long wave shallow water model. Since nonlinear processes dominate the local dynamic signal outside the tropics, subsurface dynamical quantities cannot be reliably inferred from surface height anomalies. Because of its potential for large scale synoptic coverage of the deep ocean, acoustic travel time data should be a natural complement to satellite altimetry. Satellite data give us vertical integrals associated with thermodynamic and dynamic processes.

Miller, Robert N.↗

Linear Mixed-Effects Models for Human-in-the-Loop Tracking Experiment Data

Linear mixed-effects models provide several benefits over more traditional statistical inference tests that are particularly useful for most human-in-the-loop tracking experiment data. However, surprisingly, mixed models are virtually not used for the analysis of tracking experiment data. This paper uses of linear mixed-effects models to analyze combined tracking data from two previous human-in-the-loop roll tracking experiments that compared control behavior metrics collected in both a research aircraft and a motion-base simulator. In the experiments, pilots' behavior under 10 different motion configurations with varying motion filter gains and break frequencies was evaluated and compared to that in the real aircraft. The linear mixed-effects model analysis on the combined dataset confirmed the main statistical outcomes of the individual experiments. The main benefits of mixed models for this type of data were demonstrated by successfully combining data from two experiments that used different experimental conditions and of which one had an additional apparatus and the other a missing participant. Finally, the mixed-model analysis was able to explicitly test for scientifically relevant statistical differences in the dependent measures between the aircraft and simulator, as well as both experiments.

manual control↗

High-Latitude Filtering in a Global Grid-Point Model Using Model Normal Modes

The aim of high-latitude filtering in the vicinity of the poles is to avoid the excessively short time steps imposed on an explicit time-differencing scheme by linear stability due to fast moving inertia-gravity waves near the poles. The model normal mode expansion toward the problem of high-latitude filtering in a global shallow water model using the same philosophy as that used by Daley for the problem for large timesteps in P.E. models with explicit time integration schemes was applied.

Takacs, L. L.↗

Method for Pre-Conditioning a Measured Surface Height Map for Model Validation

This software allows one to up-sample or down-sample a measured surface map for model validation, not only without introducing any re-sampling errors, but also eliminating the existing measurement noise and measurement errors. Because the re-sampling of a surface map is accomplished based on the analytical expressions of Zernike-polynomials and a power spectral density model, such re-sampling does not introduce any aliasing and interpolation errors as is done by the conventional interpolation and FFT-based (fast-Fourier-transform-based) spatial-filtering method. Also, this new method automatically eliminates the measurement noise and other measurement errors such as artificial discontinuity. The developmental cycle of an optical system, such as a space telescope, includes, but is not limited to, the following two steps: (1) deriving requirements or specs on the optical quality of individual optics before they are fabricated through optical modeling and simulations, and (2) validating the optical model using the measured surface height maps after all optics are fabricated. There are a number of computational issues related to model validation, one of which is the "pre-conditioning" or pre-processing of the measured surface maps before using them in a model validation software tool. This software addresses the following issues: (1) up- or down-sampling a measured surface map to match it with the gridded data format of a model validation tool, and (2) eliminating the surface measurement noise or measurement errors such that the resulted surface height map is continuous or smoothly-varying. So far, the preferred method used for re-sampling a surface map is two-dimensional interpolation. The main problem of this method is that the same pixel can take different values when the method of interpolation is changed among the different methods such as the "nearest," "linear," "cubic," and "spline" fitting in Matlab. The conventional, FFT-based spatial filtering method used to eliminate the surface measurement noise or measurement errors can also suffer from aliasing effects. During re-sampling of a surface map, this software preserves the low spatial-frequency characteristic of a given surface map through the use of Zernike-polynomial fit coefficients, and maintains mid- and high-spatial-frequency characteristics of the given surface map by the use of a PSD model derived from the two-dimensional PSD data of the mid- and high-spatial-frequency components of the original surface map. Because this new method creates the new surface map in the desired sampling format from analytical expressions only, it does not encounter any aliasing effects and does not cause any discontinuity in the resultant surface map.

Sidick, Erkin↗

Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy

Recent advances in coronagraph technologies for exoplanet imaging have achieved contrasts close to 1e10 at 4 lambda/D and 1e-9 at 2 lambda/D in monochromatic light. A remaining technological challenge is to achieve high contrast in broadband light; a challenge that is largely limited by chromaticity of the focal plane mask. The size of a star image scales linearly with wavelength. Focal plane masks are typically the same size at all wavelengths, and must be sized for the longest wavelength in the observational band to avoid starlight leakage. However, this oversized mask blocks useful discovery space from the shorter wavelengths. We present here the design, development, and testing of an achromatic focal plane mask based on the concept of optical filtering by a diffractive optical element (DOE). The mask consists of an array of DOE cells, the combination of which functions as a wavelength filter with any desired amplitude and phase transmission. The effective size of the mask scales nearly linearly with wavelength, and allows significant improvement in the inner working angle of the coronagraph at shorter wavelengths. The design is applicable to almost any coronagraph configuration, and enables operation in a wider band of wavelengths than would otherwise be possible. We include initial results from a laboratory demonstration of the mask with the Phase Induced Amplitude Apodization coronagraph.

Achromatic↗

A K-band Frequency Agile Microstrip Bandpass Filter using a Thin Film HTS/Ferroelectric/dielectric Multilayer Configuration

We report on YBa2Cu3O(7-delta) (YBCO) thin film/SrTiO3 (STO) thin film K-band tunable bandpass filters on LaAlO3 (LAO) dielectric substrates. The 2 pole filter has a center frequency of 19 GHz and a 4% bandwidth. Tunability is achieved through the non-linear dc electric field dependence of the relative dielectric constant of STO(epsilon(sub rSTO). A large tunability ((Delta)f/f(sub 0) = (f(sub Vmax) - f(sub 0)/f(sub 0), where f(sub 0) is the center frequency of the filter at no bias and f(sub Vmax) is the center frequency of the filter at the maximum applied bias) of greater than 10% was obtained in YBCO/STO/LAO microstrip bandpass filters operating below 77 K. A center frequency shift of 2.3 GHz (i.e., a tunability factor of approximately 15%) was obtained at a 400 V bipolar dc bias, and 30 K, with minimal degradation in the insertion loss of the filter. This paper addresses design, fabrication and testing of tunable filters based on STO ferroelectric thin films. The performance of the YBCO/STO/LAO filters is compared to that of gold/STO/LAO counterparts.

Subramanyam, Guru↗

Simplification of the Kalman filter for meteorological data assimilation

The paper proposes a new statistical method of data assimilation that is based on a simplification of the Kalman filter equations. The forecast error covariance evolution is approximated simply by advecting the mass-error covariance field, deriving the remaining covariances geostrophically, and accounting for external model-error forcing only at the end of each forecast cycle. This greatly reduces the cost of computation of the forecast error covariance. In simulations with a linear, one-dimensional shallow-water model and data generated artificially, the performance of the simplified filter is compared with that of the Kalman filter and the optimal interpolation (OI) method. The simplified filter produces analyses that are nearly optimal, and represents a significant improvement over OI.

Dee, Dick P.↗

Performance evaluation and calibration of a modular multiband radiometer for remote sensing field research

A multiband radiometer suitable for operation from helicopter, small plane, truck, or tripod platforms was developed. The standard unit is equipped with the seven thematic mapper spectral bands with an added band from 1.5 to 1.30 microns; however, up to eight user specified bands from 0.4 to 15 microns may be installed under clean field conditions. Results of prototype tests of the spectral responsivity of the detectors, the transmittance of the optical filters as a function of wavelength, the fields of view, and the system linearity, temperature stability, noise performance, and dynamic range were evaluated. Minor modifications were made to the instrument and the results of final testing are reported.

Robinson, B. F.↗

Image science team

A substantial technology base of solid state pushbroom sensors exists and is in the process of further evolution at both GSFC and JPL. Technologies being developed relate to short wave infrared (SWIR) detector arrays; HgCdTe hybrid detector arrays; InSb linear and area arrays; passive coolers; spectral beam splitters; the deposition of spectral filters on detector arrays; and the functional design of the shuttle/space platform imaging spectrometer (SIS) system. Spatial and spectral characteristics of field, aircraft and space multispectral sensors are summaried. The status, field of view, and resolution of foreign land observing systems are included.

Ando, K.↗

Nonlinear control of an experimental beam by IMSC

Results are reported from an experiment designed to control the vibratory motion of a beam at NASA, Langley Research Center. The experimental setup consists of a free-free uniform beam acted upon by four electromagnetic force actuators, with the motion being measured by nine displacement sensors. The entire assembly is linked to a CDC Cyber 175 computer which permits on-line real-time computation of the control forces. The control scheme is based on Independent Modal-Space Control (IMSC), whereby the modal forces are computed using a nonlinear, on-off control law. The actuator forces are then synthesized using a linear transformation, resulting in quantized forces. The sensors data is processed by modal filters. It is observed that the controls designed on the basis of the IMSC method are very effective in suppressing the vibratory motion of the beam, even though there is about a 50 percent differene between the actual and the analytically computed frequencies.

Meirovitch, L.↗

Multiband Selector for Linear Photodetector Array

Line image observed simultaneously in two or more spectral bands. Incoming light focused through beam splitter onto two linear arrays of photodetectors to form line images. Array of band-pass filters above each detector array positioned to select spectral band of line image. These capabilities are valuable in such multispectral-imaging applications as spaceborne and airborne visible and infrared observation of Earth for geology, oil and mineral exploration, biomass distribution, forestry, agriculture, and urban and rural development.

Richard, H. L.↗

Design and fabrication of the All-Reflecting H-Lyman-alpha Coronagraph/Polarimeter

We have designed, analyzed, and are now fabricating an All-Reflecting H-Lyman-alpha Coronagraph/Polarimeter for solar research. This new instrument operates in a narrow bandpass centered at 215.7 A - the neutral hydrogen Ly-alpha line. It is shorter and faster than the telescope which produced solar Ly-alpha images as a part of the MSSTA payload that was launched on May 13, 1991. The Ly-alpha line is produced and linearly polarized in the solar corona by resonance scattering, and the presence of a magnetic field modifies this polarization according to the Hanle effect. The Lyman-alpha Coronagraph/Polarimeter instrument has been designed to measure coronal magnetic fields by interpreting, via the Hanle effect, the measured linear polarization of the coronal Ly-alpha line. Ultrasmooth mirrors, polarizers, and filters are being flow-polished for this instrument from CVD silicon carbide substrates. These optical components will be coated using advanced induced transmission and absorption thin film multilayer coatings to optimize the reflectivity and polarization properties at 1215.7 A. We describe some of the solar imaging results obtained with the MSSTA Lyman-alpha coronagraph. We also discuss the optical design parameters and fabrication plans for the All-Reflecting H-Lyman-alpha Coronagraph/Polarimeter.

Hoover, Richard B.↗

Universal signal conditioning amplifier

A state-of-the-art instrumentation amplifier capable of being used with most types of transducers has been developed at the Kennedy Space Center. This Universal Signal Conditioning Amplifier (USCA) can eliminate costly measurement setup item and troubleshooting, improve system reliability and provide more accurate data than conventional amplifiers. The USCA can configure itself for maximum resolution and accuracy based on information read from a RAM chip attached to each transducer. Excitation voltages or current are also automatically configured. The amplifier uses both analog and digital state-of-the-art technology with analog-to-digital conversion performed in the early stages in order to minimize errors introduced by offset and gain drifts in the analog components. A dynamic temperature compensation scheme has been designed to achieve and maintain 12-bit accuracy of the amplifier from 0 to 70 C. The digital signal processing section allows the implementation of digital filters up to 511th order. The amplifier can also perform real-time linearizations up to fourth order while processing data at a rate of 23.438 kS/s. Both digital and analog outputs are available from the amplifier.

Medelius, Pedro J.↗

Laser-Induced Incandescence Calibration via Gravimetric Sampling

Various beam imaging and/or sheet forming optics delivered light at 1064 nm from a pulsed Nd:YAG laser for use either as a beam of 3 mm radius or as a laser sheet. Imaging measurements were performed with a grated intensified array camera equipped with an ultraviolet f4.5 lens and a 40 mm extension tube. Point measurements were performed using an ultraviolet 250 mm focal length lens to collect and focus the laser induced incandescence (LII) signal into a 1 meter long quartz optical fiber which directed the LII signal to a 1/4 meter monochromator. An aperture preceding the lens restricted the signal collection region to 1 cm along the laser beam at the center of the gravimetric chimney. Signals from the PMT were processed by a boxcar integrator whereas the images were captured digitally using a frame-grabber with 16 MByte of on-board memory. Both 'point' and planar measurements were made with detector gates of 250 ns to minimize possible morphology bias in collection of the LII signal. Additionally, the imaging measurements were performed with broadband spectral collection of the LII signal to maximize the signal and again minimize any potential effects of morphology dependent heating and/or cooling rates. Digital delay generators controlled the firing of he laser, detector gates and data acquisition. Neutral density filters were used for both sets of measurements to maintain signal levels within linear dynamic ranges of the detectors, the range being determined prior to experiments.

VanderWal, R. L.↗

Design and Fabrication of the All-Reflecting H-Lyman alpha Coronagraph/Polarimeter

We have designed, analyzed, and are now fabricating an All-Reflecting H-Lyman alpha Coronagraph/Polarimeter for solar research. This new instrument operates in a narrow bandpass centered at lambda 1215.7 A-the neutral hydrogen Lyman alpha (Ly-alpha) line. It is shorter and faster than the telescope which produced solar Ly-alpha images as a part of the MSSTA payload that was launched on May 13, 1991. The Ly-alpha line is produced and linearly polarized in the solar corona by resonance scattering, and the presence of a magnetic field modifies this polarization according to the Hanle effect. The Lyman alpha Coronagraph/Polarimeter instrument has been designed to measure coronal magnetic fields by interpreting, via the Hanle effect, the measured linear polarization of the coronal Ly-alpha line. Ultrasmooth mirrors, polarizers, and filters are being flow-polished for this instrument from CVD silicon carbide substrates. These optical components will be coated using advanced induced transmission and absorption thin film multilayer coatings, to optimize the reflectivity and polarization properties at 1215.7 A. We describe some of the solar imaging results obtained with the MSSTA Lyman alpha coronagraph. We also discuss the optical design parameters and fabrication plans for the All-Reflecting H-Lyman alpha Coronagraph/Polarimeter.

Hoover, Richard B.↗

Classifying Agnostic Biosignatures using Raman, VNIR, and Elemental Data

How can we use our current wealth of terrestrial data, encompassing biogenic and abiogenic systems, to determine the distinguishing properties of life? SCOBI (Statistical Classification of Biosignature Information) uses machine learning techniques to algorithmically identify combinations of measurements that are “indicative of life”. A set of ~1000 observations, comprising elemental abundance, isotopic fractionation, VNIR reflectance, and (in progress) Raman spectra, have been assembled from existing literature and databases. The observations cover systems classified as “indicative alive” (e.g., cells, vegetation), “indicative non-alive” (e.g., fossils, teeth), “mixed indicative” (e.g., soil, pond water), or “non-indicative” (e.g., rocks, meteorites). VNIR data was preprocessed by linear interpolation from 400-2100 nm and smoothed with a Savitzky-Golay filter. To limit the amount of Earth-biochemistry-specific (non-agnostic) information included, the first five spectral features extracted were number of peaks, number of troughs, mean reflectance, mean peak width, and broadest peak width. To help further emphasize agnostic biosignatures, Earth-specific features such as chlorophylls have been manually flagged so that feature importance with and without them can be compared. Classifiers including k-nearest neighbors (KNN), Gaussian Naïve Bayes (GNB), logistic regression (LR), random forest (RF), and support vector machine (SVM) were implemented, as was a combination voting classifier. Performance metrics included false positive rates, false negative rates, and AUC with 50-50 test/train splits (Monte Carlo simulations). Key takeaways from this stage, prior to the inclusion of Raman spectra, are (1) the overall success rate of 0.933 AUC was most heavily influenced by the elemental abundance data; and (2) VNIR reflectance had the lowest classification performance with 0.52 AUC (58% of objects correctly classified). The next steps are to complete integration of Raman spectral data and to improve the approach to pre-processing and feature extraction for both types of spectral data, such as automated baseline removal, whole spectrum matching, and dimensionality reduction.

Biosignatures↗