A standardized quantitative analysis strategy for stable isotope probing metagenomics

ABSTRACT Stable isotope probing (SIP) facilitates culture-independent identification of active microbial populations within complex ecosystems through isotopic enrichment of nucleic acids. Many DNA-SIP studies rely on 16S rRNA gene sequences to identify active taxa, but connecting these sequences to specific bacterial genomes is often challenging. Here, we describe a standardized laboratory and analysis framework to quantify isotopic enrichment on a per-genome basis using shotgun metagenomics instead of 16S rRNA gene sequencing. To develop this framework, we explored various sample processing and analysis approaches using a designed microbiome where the identity of labeled genomes and their level of isotopic enrichment were experimentally controlled. With this ground truth dataset, we empirically assessed the accuracy of different analytical models for identifying active taxa and examined how sequencing depth impacts the detection of isotopically labeled genomes. We also demonstrate that using synthetic DNA internal standards to measure absolute genome abundances in SIP density fractions improves estimates of isotopic enrichment. In addition, our study illustrates the utility of internal standards to reveal anomalies in sample handling that could negatively impact SIP metagenomic analyses if left undetected. Finally, we present SIPmg , an R package to facilitate the estimation of absolute abundances and perform statistical analyses for identifying labeled genomes within SIP metagenomic data. This experimentally validated analysis framework strengthens the foundation of DNA-SIP metagenomics as a tool for accurately measuring the in situ activity of environmental microbial populations and assessing their genomic potential. IMPORTANCE Answering the questions, “who is eating what?” and “who is active?” within complex microbial communities is paramount for our ability to model, predict, and modulate microbiomes for improved human and planetary health. These questions can be pursued using stable isotope probing to track the incorporation of labeled compounds into cellular DNA during microbial growth. However, with traditional stable isotope methods, it is challenging to establish links between an active microorganism’s taxonomic identity and genome composition while providing quantitative estimates of the microorganism’s isotope incorporation rate. Here, we report an experimental and analytical workflow that lays the foundation for improved detection of metabolically active microorganisms and better quantitative estimates of genome-resolved isotope incorporation, which can be used to further refine ecosystem-scale models for carbon and nutrient fluxes within microbiomes.

54 ENVIRONMENTAL SCIENCES↗

Statistical Analysis and Geologic Evaluation of Laboratory-Derived Physical Property Data for Selected Nevada Test Site Core Samples of Non-Zeolitized Tuffs

A statistical analysis and geologic evaluation of recently acquired laboratory-derived physical property data are being performed to better understand and more precisely correlate physical properties with specific geologic parameters associated with non-zeolitized tuffs at the Nevada Test Site. Physical property data include wet and dry bulk density, grain density (i.e., specific gravity), total porosity, and effective porosity. Geologic parameters utilized include degree of welding, lithology, stratigraphy, geographic area, and matrix mineralogy (i.e., vitric versus devitrified). Initial results indicate a very good correlation between physical properties and geologic parameters such as degree of welding, lithology, and matrix mineralogy. However, physical properties appear to be independent of stratigraphy and geographic area, suggesting that the data are transferrable with regards to these two geologic parameters. Statistical analyses also indicate that the assumed grain density of 2.65 grams per cubic centimeter used to calculate porosity in some samples is too high. This results in corresponding calculated porosity values approximately 5 percent too high (e.g., 45 percent versus 40 percent), which can be significant in the lower porosity rocks. Similar analyses and evaluations of zeolitic tuffs and carbonate rock physical properties data are ongoing as well as comparisons to geophysical log values.

58 GEOSCIENCES↗

Optical position meters analyzed in the noninertial reference frames

In the framework of general relativity we develop a method for the analysis of the operation of the optical position meters in their photodetectors proper reference frames. These frames are noninertial in general due to the action of external fluctuative forces on meters test masses, including detectors. For comparison we also perform the calculations in the laboratory (globally inertial) reference frame and demonstrate that for certain optical schemes laboratory-based analysis results in unmeasurable quantities, in contrast to the detector-based analysis. We also calculate the response of the simplest optical meters to weak plane gravitational waves and fluctuative motions of their test masses. It is demonstrated that for the round-trip meter analysis in both the transverse-traceless (TT) and local Lorentz (LL) gauges produces equal results, while for the forward-trip meter corresponding results differ in accordance with different physical assumptions (e.g. procedure of clocks synchronization) implicitly underlying the construction of the TT and LL gauges.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of highly-efficient electric residential HPWHs

A scoping level analysis was conducted to identify electric HPWH concepts that have the potential to achieve or exceed 30% source energy savings compared to a gas tankless water heater (GTWH) representative of the type represented in version 0.9.5.2 beta of the BEopt software developed by the National Renewable Energy Laboratory. The analysis was limited to evaluation of options to improve the energy efficiency of electric HPWH product designs currently on the market in the US. The report first defines the baseline GTWH system and determines its efficiency (source-energy-based adjusted or derated EF of ~0.71). High efficiency components (compressors, pumps, fans, heat exchangers, etc.) were identified and applied to current US HPWH products and analyzed to determine the viability of reaching the target EF. The target site-based energy factor (EF) required for an electric HPWH necessary to provide 30% source energy savings compared to the GTWH baseline unit is then determined to be ~3.19.

14 SOLAR ENERGY↗

Safety Analysis Challenges With Restart of the Idaho National Laboratory (INL) Transient Reactor Test (TREAT) Facility

Safety Analysis Challenges With Restart of the Idaho National Laboratory Transient Reactor Test (TREAT) Facility Dr. James Parry David Broussard Anthony LaPorta Douglas Gerstner Battelle Energy Alliance Idaho National Laboratory P.O. Box 1625/MS6194 Idaho Falls, ID 83415 The Transient Reactor Test Facility, commonly referred to as TREAT, is an air-cooled, thermal spectrum test reactor facility designed to: • Induce intense fission heating in the nuclear fuel being tested. • Test nuclear reactor fuels under severe reactor-accident conditions. • Study fuel meltdowns, metal-water reactions, interactions between overheated fuel and coolant, and the transient behavior of fuels for high-temperature systems. • Provide nondestructive test data through neutron radiography of fuel samples. • Allow for the detailed monitoring of the experiments during the test. TREAT was specifically designed to test prototypic-sized reactor fuel pins and bundles under transient power conditions. During its 35 year operating history, it conducted thousands of transient experiments. Today, these capabilities are required for predicting safety margins for next generation fuels and advanced reactor design safety. Even though TREAT has not operated since 1994, return to operable conditions and resumption of testing will occur in FY 2018. This paper discusses the unique challenges with performing and documenting the safety analyses that demonstrate that the TREAT restart may be performed safely. This includes a discussion of 1) the TREAT capability, design, and operations, 2) identification of the format and content of the required safety basis document changes, and 3) demonstration that the consequences of potential accidents during TREAT operations meet the consequence guidelines.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Microgravity acceleration measurement environment characterization

The Space Acceleration Measurement System (SAMS) is a general-purpose instrumentation system designed to measure the accelerations onboard the shuttle Orbiter and shuttle/Spacelab vehicles. These measurements are used to support microgravity experiments and investigations into the microgravity environment of the vehicle. Acceleration measurement can be made at locations remote from the SAMS main instrumentation unit by the use of up to three remote triaxial sensor heads. The SAMS was developed by NASA's Lewis Research Center (LeRC) in support of NASA's microgravity science programs. In the past, numerous acceleration measurement systems have flown on various space missions. These systems were tailored to measure accelerations for a narrow set of requirements and were limited in bandwidth, dynamic range, and recording capability. In addition, these systems were mission-peculiar and not easily modified for other applications or missions. The result has been an inability to accurately assess the expected microgravity environment prior to a mission for a particular experiment and/or location. The prime science objective for SAMS on the SL-J mission will be to measure the accelerations experienced by a multitude of experiments in the two racks of the Japanese First Materials Processing Test (FMPT). The FMPT consists of a variety of materials science and life science experiments contained in racks no. 7 and no. 10. The SAMS data will be made available to the FMPT principal investigators after the mission for their analysis with the FMPT data. A secondary science objective for SAMS will be the characterization of the acceleration environment of the Spacelab module. This will include an analysis of the acceleration transfer function of the Spacelab module which will utilize the FMPT acceleration measurement along with measurements at the rack no. 9 structure. Another analytical effort to be undertaken is a general characterization of the acceleration environment of the Spacelab as an orbiting laboratory. These analysis efforts will be in conjunction with similar measurements and analyses on other SAMS Spacelab missions.

Delombard, Richard↗

Evaluation of atmospheric trace constituent sensors operating from remote space and airborne platforms

A laboratory gas analysis system was developed specifically to make trace level measurements of carbon monoxide. To assure that the data collected with this system are correctly aligned with other established methods for making these measurements, an intercalibration study was conducted. The calibration gas was analyzed by the various participating laboratories and found to contain 1.28 ppm CO. Samples were collected at 25 deg, 35 deg, and 45 deg N for profile data to study the variation in concentrations of CO and CH4 as a function of altitude and latitude in continental air over the eastern seaboard of the United States. The experiment was repeated several months later to determine if there were seasonally dependent variations in the CO and CH4 concentrations.

Condon, E.↗

Pore characterization of the Marcellus Shale by nitrogen adsorption and prediction of its gas storage capacity

In a shale gas reservoir, pore characterization is an important factor used to determine gas storage capacity. However, the nanometer (nm)-scale pore system in shale is difficult to explore by traditional optical, scanning electron microscopy, or even nuclear magnetic resonance well logging. We have investigated the pore structure and storage capacity of the Marcellus Shale through integration of petrophysical analysis from laboratory and well-logging data and nitrogen adsorption. The isotherm of Marcellus Shale is a composite isotherm, which has features of type I, type II, and type IV isotherms with type H4 of the hysteresis loop, suggesting slit-like pores developed in the Marcellus Shale. Quantitative analysis of pore volumes from the nitrogen adsorption indicates that density porosity may be more properly used to approximate the shale porosity and estimate the shale gas volume. In addition, the specific surface area, micropore, and mesopore volumes have a positive relationship with the kerogen volume and total organic content (TOC). By using the Langmuir and Brunauer-Emmet-Teller models, the simulated result indicates that the higher adsorbed quantity of the Marcellus Shale could be the result of the increase of micropore volume contributed, by the increase of kerogen or TOC content. The proposed equations rapidly compute TOC, a key parameter to predict gas storage capacity in overmature shale such as the Marcellus Shale.

Geochemistry & Geophysics↗

Lignin Fast Pyrolysis: Results from an International Collaboration

An international study of fast pyrolysis of lignin was undertaken. Fourteen laboratories in eight different countries contributed. Two lignin samples were distributed to the laboratories for analysis and bench-scale process testing in fast pyrolysis. Analyses included proximate and ultimate analysis, thermogravimetric analysis, and analytical pyrolysis. The bench-scale test included bubbling fluidized bed reactors and entrained flow systems. Based on the results of the various analyses and tests it was concluded that a concentrated lignin (estimated at about 50% lignin and 50% cellulose) behaved like a typical biomass, producing a slightly reduced amount of a fairly typical bio-oil, while a purified lignin material was difficult to process in the fast pyrolysis reactors and produced a much lower amount of a different kind of bio-oil. It was concluded that for highly concentrated lignin feedstocks new reactor designs will be required other than the typical fluidized bed fast pyrolysis systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Overview of zion comparative analysis project for assessment of Boral{sup R} neutron absorber material performance and monitoring in spent fuel pools - 14618

Neutron absorber materials are used in spent fuel pool (SFP) storage racks to control reactivity. In the United States, about half of the operating plants currently use BORAL{sup R} neutron absorber material in SFP racks. Although operational experience spanning more than 25 years has not shown any loss of the BORAL{sup R} core material, corrosion effects, including blisters and pits, have been observed and reported. To improve understanding for the behavior of BORAL{sup R} in SFPs and evaluate the performance of monitoring approaches, EPRI initiated the Zion comparative analysis project in 2014. The Zion project involves three phases. During the first phase of the project, in situ measurements were performed on selected SFP rack panels in December 2014. Panels for in situ measurements were selected after an extensive analysis of each panel in the pool to ensure that the selected panels represented the pool in terms of variation in neutron and gamma dose values. As part of the second phase of the project, the remaining 10 coupons from the Zion SFP were shipped to a Penn State University (PSU) laboratory for analysis in January 2015. During the final phase of the project, a subset of the panels for which in situ measurements were performed will be harvested from the Zion SFP, cut into samples, and analyzed at PSU. The overall scope of this project will allow comparison of in situ measurements to real panel data as well as data obtained from coupon analysis. In this paper, an overview of the Zion comparative analysis project, the criteria and procedure for panel selection for in situ measurements and harvesting, preliminary coupon analysis results and in situ measurement results are presented. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Return of Astromaterials to Earth Over the Next Decade

We are entering a new and golden age of sample return missions. In the coming decade we will harvest samples from Comet P/Wild II and interstellar dust courtesy of the STARDUST Mission (Brownlee et al., 1997), an asteroid (probably 4660 Nereus or 1989ML) by the ISAS MUSES-C Mission (ISAS, 1997), and solar wind by the Genesis Mission. A sample return from Mars is also envisioned as early as 2008, and possibly one from the two moons of Mars. It is, however, sobering to realize that MUSES-C aims to return 3-10 g of sample, STARDUST will provide micrograms of comet and interstellar dust, and Genesis will harvest only few micrograms of atoms. The diminutive size of the returning samples may be a source of concern for petrologists used only to looking at hefty lunar rocks and meteorites. How much sample is really needed to achieve prime science objectives, while maintaining a cost effective mission? The range of geological processes that we will want to address with these samples is staggering, encompassing not merely the entire history of the Solar system, but the history of the elements themselves. The interstellar processes include element formation, production and interactions with radiation, formation of organics, grain condensation and evolution, and interactions with magnetic fields. In the pre-accretionary (nebular) environment we wish to understand grain condensation, evaporation and recondensation, shock, radiation processing, solar energetic particle implantation, gas composition, the magnetic environment, and the evolution of organics. Finally, for solid bodies we wish to examine accretion history, shock, brecciation, impact gardening, metamorphism, aqueous alteration, weathering, exposure history, volcanism, fumarolic activity, differentiation, the magnetic environment, atmosphere evolution, and the evolution of organics. Since 1981, NASA has supported asteroid and comet science by collecting dust grains from these bodies in the stratosphere, and making them available for analysis in laboratories worldwide (Warren and Zolensky, 1994). Over the succeeding 17 years, many new techniques have been developed for these painstaking analyses, by at least 24 different laboratories across the globe. Despite the fact that the particle supply has always exceeded the demand, the painstaking efforts required for most of the nano-scale analyses have resulted in only 1520 grains having been analyzed, with a total mass of only 0.52 micrograms. Thus we really require less sample for analysis than one might imagine.

Zolensky, Michael E.↗

Results of the second Round Robin on opening-load measurement conducted by ASTM Task Group E24.04.04 on crack closure measurement and analysis

A second experimental Round Robin on the measurement of the crack opening load in fatigue crack growth tests has been completed by the ASTM Task Group E24.04.04 on Crack Closure Measurement and Analysis. Fourteen laboratories participated in the testing of aluminum alloy compact tension specimens. Opening-load measurements were made at three crack lengths during constant Delta K, constant stress ratio tests by most of the participants. Four participants made opening-load measurements during threshold tests. All opening-load measurements were based on the analysis of specimens compliance behavior, where the displacement/strain was measured either at the crack mouth or the mid-height back face location. The Round Robin data were analyzed for opening load using two non-subjective analysis methods: the compliance offset and the correlation coefficient methods. The scatter in the opening load results was significantly reduced when some of the results were excluded from the analysis population based on an accept/reject criterion for raw data quality. The compliance offset and correlation coefficient opening load analysis methods produced similar results for data populations that had been screened to eliminate poor quality data.

Phillips, E. P.↗

Meteorological Instruction Software

At Florida State University and the Naval Postgraduate School, meteorology students have the opportunity to apply theoretical studies to current weather phenomena, even prepare forecasts and see how their predictions stand up utilizing GEMPAK. GEMPAK can display data quickly in both conventional and non-traditional ways, allowing students to view multiple perspectives of the complex three-dimensional atmospheric structure. With GEMPAK, mathematical equations come alive as students do homework and laboratory assignments on the weather events happening around them. Since GEMPAK provides data on a 'today' basis, each homework assignment is new. At the Naval Postgraduate School, students are now using electronically-managed environmental data in the classroom. The School's Departments of Meteorology and Oceanography have developed the Interactive Digital Environment Analysis (IDEA) Laboratory. GEMPAK is the IDEA Lab's general purpose display package; the IDEA image processing package is a modified version of NASA's Device Management System. Bringing the graphic and image processing packages together is NASA's product, the Transportable Application Executive (TAE).

Source record↗

Analysis of Dust Samples Collected from an Inland ISFSI Site (Site A)

In September of 2020, dust samples were collected from the surface of spent nuclear fuel (SNF) dry storage canisters during an inspection at an inland Independent Spent Fuel Storage Installation. The purpose of the sampling was to assess the composition and abundance of the soluble salts present on the canister surface, information which provides a metric for potential corrosion risks. The samples were delivered to Sandia National laboratories for analysis. At Sandia, the soluble salts were leached from the dust and quantified by ion chromatography. In addition, subsamples of the dust were taken for scanning electron microscope analysis to determine the texture and mineralogy of the dust and salts. The results of those analyses are presented in this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Portable total reflection x-ray fluorescence analysis in the identification of unknown laboratory hazards

In this study, a portable total reflection x-ray fluorescence (TXRF) spectrometer was used to analyze unknown laboratory hazards that precipitated on exterior surfaces of cooling pipes and fume hood pipes in chemical laboratories. With the aim to examine the accuracy of TXRF analysis for the determination of elemental composition, analytical results were compared with those of wavelength-dispersive x-ray fluorescence spectrometry, scanning electron microscope and energy-dispersive x-ray spectrometry, energy-dispersive x-ray fluorescence spectrometry, inductively coupled plasma atomic emission spectrometry, x-ray diffraction spectrometry (XRD), and x-ray photoelectron spectroscopy (XPS). Detailed comparison of data confirmed that the TXRF method itself was not sufficient to determine all the elements (Z > 11) contained in the samples. In addition, results suggest that XRD should be combined with XPS in order to accurately determine compound composition. This study demonstrates that at least two analytical methods should be used in order to analyze the composition of unknown real samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gem Analysis

World Gem Laboratory, Inc.'s cathodoluminoscope is an instrument that magnifies a specimen and produces heat-generated light emissions that bring out features important in gemological analysis. It can indicate whether a stone can be successfully cut, useful in the study of growth and strain patterns in diamonds, detection of dyes in jade, and analysis of the growth and structure of rubies and sapphires. In combination with other tests these analyses can separate synthetic from natural gems.

Source record↗

Analysis of Dust Samples Collected from an Inland ISFSI Site (''Site B'').

In October of 2020, dust samples were collected from the surface of spent nuclear fuel (SNF) dry storage canisters during an inspection at an inland Independent Spent Fuel Storage Installation, the second inland site at which surface deposits have been sampled. The purpose of the sampling was to assess the composition and abundance of the soluble salts present on the canister surface, information which provides a metric for potential corrosion risks. The samples were delivered to Sandia National laboratories for analysis. At Sandia, the soluble salts were leached from the dust and quantified by ion chromatography. In addition, subsamples of the dust were taken for scanning electron microscopy to determine the texture and mineralogy of the dust and salts. The results of those analyses are presented in this report.