ANALYSIS OF SURFACE MAGNETIC FIELDS BY INTEGRALS
Magnetic field analysis by integrals applied to test fields prescribed over the surface of a sphere using an electronic computer
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Magnetic field analysis by integrals applied to test fields prescribed over the surface of a sphere using an electronic computer
Interplanetary magnetic field and plasma flux measurements by explorer x satellite
The magnetic confinement of plasmas in fusion experiments can significantly degrade due to perturbations of the magnetic field. A precise analysis of the magnetic field in a stellarator-type experiment utilizes electrons as test particles following the magnetic field line. The usual fluorescent detector for this electron beam limits the provided information to two-dimensional cut views at certain toroidal positions. However, the technique described in this article allows measuring the three-dimensional structure of the magnetic field by means of close-range photogrammetry. After testing and optimizing the main diagnostic components, measurements of the magnetic field lines were accomplished with a spatial resolution of 5 mm. The results agree with numeric calculations, qualifying this technique as an additional tool to investigate magnetic field configurations in a stellarator. For a possible future application, ways are indicated on how to reduce experimental error sources.
Interplanetary magnetic field measurements using flux gate magnetometer sensor mounted on Pioneer VI space probe, noting various graphs
Abstract Root phenotyping provides critical information to plant breeders for developing varieties with improved drought tolerance, greater root biomass, and greater nutrient use efficiency. Phenotyping roots in the natural environment is important for understanding the effect of the soil environment on root genotypic expressions. The goal of this work was to design and test a field‐scale mobile low‐field magnetic resonance imaging (LF‐MRI) Rhizotron that produces actionable root phenotyping data. We demonstrated this novel technology for root visualization and quantification using a LF‐MRI Rhizotron operating at 47 mT with two soil types. The LF‐MRI Rhizotron weights 453 kg, with a height of 90 cm, a diameter of 28 cm and an imaging field of view of 28 cm × 28 cm. The unit was operated in a Belk clay (Entic Hapluderts) and Weswood silt loam (Udifluventic Halustepts) generating 2‐D and 3‐D image data sets. The 2‐D image data had a collection time of 16.5 min per image at an image resolution of 2.2 mm per pixel. The 3‐D data had a collection time of 13 h per image with a 2.2 × 2.2 × 2.2 mm voxel resolution. Low‐field magnetic resonance imaging worked well for visualizing roots in moderate to high clay soils, demonstrating the potential for this technology; however, the broad application of this platform is hampered due to the prohibitively long scanning time to obtain 3‐D images. By increasing the field strength, and therefore the signal‐to‐noise ratio, faster scan times can enable a more useful system for root phenotyping.
Ultra-low magnetic field testing requires precise and finely calibrated instrumentation interacting with very marginal magnetic fields in highly controlled environments. We designed a large Helmholtz coil system for implementation around a 17.825-inch outer diameter Helium-3 Cryogenic fridge, to serve as both a field-zeroing device and to enable higher resolution on magnetic field sweeps during experiments. We present finite volume modeling and finite element analysis results which indicate the device could safely run at 20 [A] in perpetuity, producing a magnetic field of 65 [mT], without the surface facing the Cryogenic fridge exceeding 50°C. The overall system parts expense is $\$$4,882.76.
The magnetic field strength inside a model coronal loop is 'estimated' using coronal seismology, to examine the reliability of magnetic field strengths derived from observed, transverse coronal loop oscillations. Three-dimensional numerical simulations of the interaction of an external pressure pulse with a coronal loop (modeled as a three-dimensional density enhancement inside a two-dimensional magnetic arcade) are analyzed and the 'observed' properties of the excited transverse loop oscillations are used to derive the value of the local magnetic field strength, following the method of Nakariakov and Ofman. Due to the (unexpected) change in periodicity, the magnetic field derived from our 'observed' oscillation is substantially different from the actual (input) magnetic field value (approximately 50%). Coronal seismology can derive useful information about the local magnetic field, but the combined effect of the loop curvature, the density ratio, and aspect ratio of the loop appears to be more important than previously expected.
The magnetized resistivity and electrothermal tensors when substituted into the induction equation lead to electrothermal magnetic field generation, resistive magnetic diffusion, and magnetic field advection due to resistivity gradients, temperature gradients and currents. Here, the advection terms driven by temperature gradient and current have cross-field components (perpendicular to both the magnetic field and the driving term) that depend on significantly modified versions of Braginskii’s transport coefficients. The improved fits to Braginskii’s coefficients given by Epperlein and Haines and Ji and Held give physically incorrect results for cross-field advection at small Hall parameters (product of cyclotron frequency and collision time). The errors in Epperlein and Haines’ fits are particularly severe, giving increasing advection velocities below a Hall parameter of one when they should decrease linearly to zero. Epperlein and Haines’ fits can also give erroneous advection terms due to variations in effective atomic number. The only serious error in Braginskii’s fits is an overestimate in advection due to perpendicular resistivity. New fits for the cross-field advection terms are obtained from a direct numerical solution of the Fokker-Planck equation and Ji and Held’s higher order expansion approach that are continuous functions of the effective atomic number.
The Thomas Jefferson National Accelerator Facility (JLab) has developed a unique spectrometer system to study the weak interaction between electrons. The "Measurement of Lepton-Lepton Electroweak Reaction" (MOLLER) experiment, utilizing JLab's recent 12 GeV electron beam upgrade, is scheduled to operate for three years. Central to the MOLLER experiment are five water-cooled toroidal magnets, each with a unique geometry and seven-fold symmetry, designed to focus the particles. These magnets generate the magnetic field needed to separate incident beam electrons scattered from target electrons (Møller scattering) and protons (elastic e-p scattering) within a liquid hydrogen target. Here, this paper details the magnet field measuring technique developed to map all five MOLLER toroidal magnets at multiple locations inside and along the bore. It covers the design, mounting, and operation of the probe, along with the calibration procedure to determine the field and to prepare a field map for GEANT4 analysis. Additionally, the paper addresses the challenges of accurately measuring low magnetic fields.
The long-term evolution of large domain particle-in-cell simulations of collisionless magnetic reconnection is investigated following observations that show two possible outcomes for collisionless reconnection: toward a Petschek-like configuration or toward multiple X points. In the present simulation, a mixed scenario develops. At earlier time, plasmoids are emitted, disrupting the formation of Petschek-like structures. Later, an almost stationary monster plasmoid forms, preventing the emission of other plasmoids. A situation reminiscent of Petschek’s switch-off then ensues. Switch-off is obtained through a slow shock/rotational discontinuity compound structure. Two external slow shocks (SS) located at the separatrices reduce the in-plane tangential component of the magnetic field, but not to zero. Two transitions reminiscent of rotational discontinuities (RD) in the internal part of the exhaust then perform the final switch-off. Both the SS and the RD are characterized through analysis of their Rankine–Hugoniot jump conditions. A moderate guide field is used to suppress the development of the firehose instability in the exhaust.
The performance characteristics of a Multi-cusped Field Thruster depending on the magnetic field in the plume region were investigated. Five magnetic field shielding rings were separately mounted near the exit of discharge channel to decrease the strength of magnetic field in the plume region in different levels, while the magnetic field in the upstream was well maintained. The test results show that the electron current increases with the decrease of magnetic field strength in the plume region, which gives rise to higher propellant utilization and lower current utilization. On the other hand, the stronger magnetic field in the plume region improves the performance at low voltages (high current mode) while lower magnetic field improves the performance at high voltages (low current mode). This work can provide some optimal design ideas of the magnetic strength in the plume region to improve the performance of thruster.
The spatial topology of magnetic field lines can be chaotic for fields generated by simple current configurations. This is illustrated for a system consisting of a circular current loop and a straight current wire. An asymmetric configuration of the current system leads to three-dimensional spatially chaotic magnetic fields. The motion of charged particles in these fields is not necessarily chaotic and exhibits intriguing dynamical properties. Particles having initial velocities closely aligned with the direction of the local magnetic field are likely to follow chaotic orbits in phase space. Other particles follow coherent and periodic orbits; these orbits being the same as in the symmetric current configuration for which the field lines are not chaotic. An important feature of particles with chaotic motion is that they undergo spatial transport across magnetic field lines. The cross-field diffusion is of interest in a variety of magnetized plasmas including laboratory and astrophysical plasmas.
Helical magnetic fields are injected into the cosmic medium during cosmological baryogenesis and can potentially provide a useful probe of the early universe. We construct a model to study the injection process during a first order phase transition and to determine the power spectra of the injected magnetic field. By Monte Carlo simulations we evaluate the Fourier space symmetric and helical power spectra of the magnetic field at the time the phase transition completes. The spectra are peaked at the scale given by the inverse size of bubbles at percolation and with a comparable width. These injected magnetic fields set the initial conditions for further cosmological magneto-hydrodynamical evolution.
Pulse-induced transients such as eddy currents can cause problems in measurement techniques where a signal is acquired after an applied preparatory pulse. In ultra-low-field magnetic resonance imaging, performed in magnetic fields typically of the order of 100 μT, the signal-to-noise ratio is enhanced in part by prepolarizing the proton spins with a pulse of much larger magnetic field and in part by detecting the signal with a Superconducting QUantum Interference Device (SQUID). The pulse turn-off, however, can induce large eddy currents in the shielded room, producing an inhomogeneous magnetic-field transient that both seriously distorts the spin dynamics and exceeds the range of the SQUID readout. It is essential to reduce this transient substantially before image acquisition. We introduce dynamical cancellation (DynaCan), a technique in which a precisely designed current waveform is applied to a separate coil during the later part and turn off of the polarizing pulse. This waveform, which bears no resemblance to the polarizing pulse, is designed to drive the eddy currents to zero at the precise moment that the polarizing field becomes zero. We present the theory used to optimize the waveform using a detailed computational model with corrections from measured magnetic-field transients. SQUID-based measurements with DynaCan demonstrate a cancellation of 99%. Dynamical cancellation has the great advantage that, for a given system, the cancellation accuracy can be optimized in software. This technique can be applied to both metal and high-permeability alloy shielded rooms, and even to transients other than eddy currents.
Not Available
Not Available