Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASS SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Ionization of 2,5-dimethylfuran by electron impact and resulting ion-parent molecule reactions

2,5-dimethylfuran (C{sub 6}H{sub 8}O) is an important fuel additive and a possible renewable liquid fuel for the future. This paper presents a recent Fourier transfer mass spectrometry study on the formation of ions from C{sub 6}H{sub 8}O by electron impact ionization and by ion-molecule reactions. Cross sections of the partial electron impact ionization have been measured and the pathways of major fragmentation channels of the parent ion have been examined. The kinetics of the reactions of C{sub 6}H{sub 8}O with selected product ions from electron impact and Ar{sup +} have been studied.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cu penetration into low-k dielectric during deposition and bias-temperature stress

Cu penetration into low-k dielectrics can cause serious reliability issues in on-chip interconnect systems. Using secondary ion mass spectrometry with both front-side and back-side depth profiling strategies, Cu was found to diffuse into SiCOH low-k dielectric in a Cu/SiCOH/Si capacitor during Cu deposition. After bias-temperature stressing the capacitor at 270 deg. C and 2.5 MV/cm, Cu penetrates further into SiCOH, but its distribution profile is the same as that after the same temperature annealing without electrical bias, suggesting no Cu ion drift. The implication of these findings on the Cu/low-k dielectric time-dependent dielectric breakdown modeling is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Summertime Aerosol across the North Slope of Alaska Field Campaign Report

The Summertime Aerosol across the North Slope of Alaska U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility field campaign, a collaborative effort between the University of Michigan and Baylor University, was focused on chemically characterizing sources of summertime aerosol impacting the Utqiagvik (Barrow, NSA) and the Oliktok Point (AMF3) ARM sites. This campaign was co-funded by a grant from the National Oceanic and Atmospheric Administration (NOAA, PI: Kerri Pratt, Co-I: Rebecca Sheesley) titled “Assessment of Atmospheric Aerosols Resulting from Oil and Gas Extraction Activities near the North Slope of Alaska”. The ARM field campaign took place on the North Slope of Alaska (NSA) from August 21 to September 30, 2015 and August 12 to September 20, 2016, with filter sampling occurring both years at both the NSA Barrow and AMF3 Oliktok Point sites. Online intensive measurements occurred at Barrow in 2015 and at Oliktok Point in 2016, coordinated with the arrival of the ARM Aerosol Observing System (AOS) in August 2016 at Oliktok Point. During 2015, the University of Michigan deployed the newly constructed aerosol time-of-flight mass spectrometer (ATOFMS), as well as a microanalysis particle sampler (MPS) to collect particles for offline analysis by computer-controlled scanning electron microscopy with energy-dispersive x-ray spectroscopy (CCSEM-EDX). Unfortunately, an issue with the time-of-flight mass spectrometer on the ATOFMS limited the number of particles that produced mass spectra during the 2015 study. This issue was subsequently fixed for the 2016 deployment. During 2016, the ATOFMS was deployed to the AMF3 at the Oliktok Point field site, in addition to a micro-orifice uniform deposition impactor (MOUDI) to collect particles for offline analysis by CCSEM-EDX. Notably, these measurements, to our knowledge, represent the first real-time, single-particle chemical characterization (aerosol mixing state) measurements at Utqiagvik and Oliktok Point. Online aerosol measurements also included: PM2.5 (particulate matter <2.5 μm) black carbon mass concentrations (aethalometer; Baylor) and size-resolved (0.013-20 μm) number concentrations (scanning mobility particle sizer, SMPS, and aerodynamic particle sizer, APS; Michigan). Baylor conducted filter sampling at both the Utqiagvik and Oliktok Point locations during both intensive operational periods (IOPs). Baylor deployed a total suspended particulate matter (TSP) sampler to Oliktok Point, and continuous one-week samples were collected in 2015 for a total of seven samples; during 2016, continuous 3-7 day samples were collected, for a total of 13 filters. Baylor deployed a TSP sampler and a PM1.0 sampler at Utqiagvik, Alaska; continuous 4-7 day filter samples were collected in 2015 for a total of eight samples. To supplement this campaign, PI Sheesley had a simultaneous DOE ARM field campaign at Utqiagvik and Oliktok Point (https://www.arm.gov/research/ campaigns/amf2016bbc), the goal of which was to collected continuous one-week TSP samples at both sites from June 2016 to September 2017. These results provide better context in terms of annual trends and for year-to-year variability and a final report with data was already submitted by PI Sheesley for that project. Analysis by Baylor focuses on TSP samples because of the extremely low PM loading on the PM1.0 sampler. Michigan deployed a three-stage impactor (0.07-5 μm PM collection) at Utqiagvik and a 10-stage impactor (0.056-10 μm PM collection) at Oliktok Point, during the 2015 and 2016 campaigns, respectively.

Arctic processes, North Slope of Alaska, Barrow, O↗

Search for dijet resonances with data scouting in proton-proton collisions at $\sqrt{s}=13$ TeV

A search is presented for narrow resonances, with a mass between 0.6 and 1.8 TeV, decaying to pairs of jets, in proton-proton collisions at $\sqrt{s}=13$ TeV. The search is performed using dijets that are reconstructed, selected, and recorded in a compact form by the high-level trigger in a technique referred to as “data scouting”, from data collected in 2016–2018 corresponding to an integrated luminosity of 117 fb −1 . The dijet mass spectra are well described by a smooth parameterization, and no significant evidence for the production of new particles is observed. Model-independent upper limits are presented on the product of the cross section, branching fraction, and acceptance for the individual cases of narrow quark-quark, quark-gluon, and gluon-gluon resonances, and are compared to the predictions from a variety of models of narrow dijet resonance production. The upper limit on the coupling of a dark matter mediator to quarks is presented as a function of the mediator mass. The sensitivity of this search goes beyond what is expected from statistical scaling with the integrated luminosity alone, as a consequence of the use of fewer parameters in the background function within a more robust statistical procedure.

beyond Standard Model↗

Ion yields and erosion rates for Si{sub 1-x}Ge{sub x}(0<=x<=1) ultralow energy O{sub 2}{sup +} secondary ion mass spectrometry in the energy range of 0.25-1 keV

We report the SIMS parameters required for the quantitative analysis of Si{sub 1-x}Ge{sub x} across the range of 0<=x<=1 when using low energy O{sub 2}{sup +} primary ions at normal incidence. These include the silicon and germanium secondary ion yield [i.e., the measured ion signal (ions/s)] and erosion rate [i.e., the speed at which the material sputters (nm/min)] as a function of x. We show that the ratio R{sub x} of erosion rates, Si{sub 1-x}Ge{sub x}/Si, at a given x is almost independent of beam energy, implying that the properties of the altered layer are dominated by the interaction of oxygen with silicon. R{sub x} shows an exponential dependence on x. Unsurprisingly, the silicon and germanium secondary ion yields are found to depart somewhat from proportionality to (1-x) and x, respectively, although an approximate linear relationship could be used for quantification across around 30% of the range of x (i.e., a reference material containing Ge fraction x would give reasonably accurate quantification across the range of +-0.15x). Direct comparison of the useful (ion) yields [i.e., the ratio of ion yield to the total number of atoms sputtered for a particular species (ions/atom)] and the sputter yields [i.e., the total number of atoms sputtered per incident primary ion (atoms/ions)] reveals a moderate matrix effect where the former decrease monotonically with increasing x except at the lowest beam energy investigated (250 eV). Here, the useful yield of Ge is found to be invariant with x. At 250 eV, the germanium ion and sputter yields are proportional to x for all x.

36 MATERIALS SCIENCE↗

International Space Station (ISS) Environmental Control and Life Support System (ECLSS) Vent Flow Reflection and Detection by Robotic External Leak Locator (RELL)

On-orbit Robotic External Leak Locator (RELL) (i.e., mass spectrometer and ion gauge) measurements on the International Space Station (ISS) are presented to show the detection of recurring Environmental Control and Life Support System (ECLSS) vents at multiple ISS locations and RELL pointing directions. The path of ECLSS effluents to the RELL detectors is not entirely obvious at some locations, but the data indicates that diffuse gas-surface reflection or scattering resulting from plume interaction with vehicle surfaces is responsible. RELL was also able to confirm the ISS ECLSS constituents and distinguish them from the ammonia leak based on the ion mass spectra and known venting times during its operation to locate a leak in the ISS port-side External Active Thermal Control System (EATCS) coolant loop.

Gas/Surface Reflections or Scattering↗

Ultrasensitive Nanoelectrospray Ionization-Mass Spectrometry using Poly(dimethylsiloxane) Microchips with Monolithically Integrated Emitters

Poly(dimethylsiloxane) (PDMS) is the most widely used substrate for microfluidic devices as it enables facile fabrication and has other distinctive properties. However, for applications involving highly sensitive nanoelectrospray ionization mass spectrometry (nanoESI-MS) detection, the use of PDMS microdevices has been hindered by the leaching of uncross-linked oligomers and other contaminants from the substrate that yields a large background of chemical noise in the mass spectra. A more general challenge is that microfluidic devices containing integrated electrospray emitters are frequently unable to operate stably in the nanoflow regime where the best sensitivity is achieved. In this report, we extracted the contaminants from PDMS substrates using a series of solvents, eliminating the background observed when untreated PDMS microchips are used for nanoESI-MS. Optimization of the integrated emitter geometry enabled stable operation at flow rates as low as 10 nL/min. Peptide concentrations of 1 nM were readily detected, representing ~170 zmol of consumed analyte, and an extrapolated detection limit of ~40 zmol; these are the lowest mass and concentration detection limits reported to date for a microchip having an integrated electrospray emitter.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sputtering of sulfur by kiloelectronvolt ions - Application to the magnetospheric plasma interaction with Io

Accurate measurements of the yields, mass spectra, and energy spectra of ejected sulfur are presented based on vapor deposits of sulfur at temperatures and ion energies relevant to the plasma interaction with the surface of Io. The measured sputtering yields are much lower than previous estimates for room temperature sulfur films, but are comparable to previous measurements of low-temperature keV ion sputtering of SO2. Results suggest that if ions reach the surface of Io its atmosphere will have a nonnegligible sulfur component which is primarily S2. Comparison of injection rates determined for sulfur with those for SO2 indicates that injection from sulfur deposits contributes 13 percent to the total mass injection rate of about 2-3 x 10 to the 29th amu/sec.

Chrisey, D. B.↗

Use of Interrupted Helium Flow in the Analysis of Vapor Samples with Flowing Atmospheric-Pressure Afterglow-Mass Spectrometry

The flowing atmospheric-pressure afterglow (FAPA) source was used for the mass-spectrometric analysis of vapor samples introduced between the source and mass spectrometer inlet. Through interrupted operation of the plasma-supporting helium flow, helium consumption is greatly reduced and dynamic gas behavior occurs that was characterized by schlieren imaging. Moreover, mass spectra acquired immediately after the onset of helium flow exhibit a signal spike before declining and ultimately reaching a steady level. This initial signal appears to be due to greater interaction of sample vapor with the afterglow of the source when helium flow resumes. In part, the initial spike in signal can be attributed to a pooling of analyte vapor in the absence of helium flow from the source. Finally, time-resolved schlieren imaging of the helium flow during on and off cycles provided insight into gas-flow patterns between the FAPA source and the MS inlet that were correlated with mass-spectral data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Erbium diffusion in silicon dioxide

Erbium diffusion in silicon dioxide layers prepared by magnetron sputtering, chemical vapor deposition, and thermal growth has been investigated by secondary ion mass spectrometry, and diffusion coefficients have been extracted from simulations based on Fick's second law of diffusion. Erbium diffusion in magnetron sputtered silicon dioxide from buried erbium distributions has in particular been studied, and in this case a simple Arrhenius law can describe the diffusivity with an activation energy of 5.3{+-}0.1 eV. Within a factor of two, the erbium diffusion coefficients at a given temperature are identical for all investigated matrices.

36 MATERIALS SCIENCE↗

Influence of sputter rate and crystal orientation on the distribution of carbon in polycrystalline copper surfaces treated by plasma immersion ion implantation

The sputter rate influences the resulting thickness of the carbon containing layer within a surface that was treated by plasma immersion ion implantation. Choosing a polycrystalline substrate with rather large crystals and a material with an inherent high sputter rate, inhomogeneous distributions of carbon over the substrate area due to different thicknesses of the incorporated carbon can be detected. A correlation of three factors namely the carbon x-ray intensity in electron probe microanalysis, the thickness of the carbon layer, and the sputter rate in depth profiling measurements via secondary ion mass spectrometry can be shown. Essential for these factors is the crystal orientation that is visualized by mapping via electron backscatter diffraction. The differences in carbon content due to the orientation are most likely one of the reasons that the adhesion of diamond-like carbon films on copper does not improve with an interlayer of implanted carbon.

36 MATERIALS SCIENCE↗

Hydrophobic treatment of organics against glass employing nonequilibrium atmospheric pressure pulsed plasmas with a mixture of CF{sub 4} and N{sub 2} gases

A hydrophobic organics surface selectively against glass was realized by employing nonequilibrium atmospheric-pressure pulsed plasmas with a mixture of CF{sub 4} and N{sub 2} gases. The organic surface was drastically altered to have a high hydrophobicity, while the glass surface itself remained hydrophilic after the plasma treatment with the addition of a small amount of CF{sub 4} to the N{sub 2} gas. After 100 CF{sub 4}/N{sub 2} plasma treatments, no thin film deposition was observed on the organic material. To investigate the characteristics of the CF{sub 4}/N{sub 2} plasma, the exhaust gas from the plasma was measured by using ion attachment mass spectroscopy (IAMS). The IAMS spectrum indicated that the amounts of CF{sub 3} and F radicals were increased drastically with increasing addition of CF{sub 4}. A mechanism of the selective surface modification was clarified on a result of surface chemical bonding with the gas phase.

36 MATERIALS SCIENCE↗

Atomic Force Microscopy Thermally-Assisted Microsampling with Atmospheric Pressure Temperature Ramped Thermal Desorption/Ionization-Mass Spectrometry Analysis

The use of atomic force microscopy controlled nano-thermal analysis probes for reproducible spatially resolved thermally-assisted sampling of micrometer-sized areas (ca. 11 m 17 m wide 2.4 m deep) from relatively low number average molecular weight (M n < 3000) polydisperse thin films of poly(2-vinylpyridine) (P2VP) is presented. Following sampling, the nano-thermal analysis probes were moved up from the surface and the probe temperature ramped to liberate the sampled materials into the gas phase for atmospheric pressure chemical ionization and mass spectrometric analysis. Furthermore, the procedure and mechanism for material pickup, the sampling reproducibility and sampling size are discussed and the oligomer distribution information available from slow temperature ramps versus ballistic temperature jumps is presented. For the M n = 970 P2VP, the Mn and polydispersity index determined from the mass spectrometric data were in line with both the label values from the sample supplier and the value calculated from the simple infusion of a solution of polymer into the commercial atmospheric pressure chemical ionization source on this mass spectrometer. With a P2VP sample of higher Mn (M n = 2070 and 2970), intact oligomers were still observed (as high as m/z 2793 corresponding to the 26-mer), but a significant abundance of thermolysis products were also observed. In addition, the capability for confident identification of the individual oligomers by slowly ramping the probe temperature and collecting data dependent tandem mass spectra was also demonstrated. We also discuss the material type limits to the current sampling and analysis approach as well as possible improvements in nano-thermal analysis probe design to enable smaller area sampling and to enable controlled temperature ramps beyond the present upper limit of about 415°C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coherence mapping to identify the intermediates of multi-channel dissociative ionization

Identifying the short-lived intermediates and reaction mechanisms of multi-channel radical cation fragmentation processes remains a current and important challenge to understanding and predicting mass spectra. We find that coherent oscillations in the femtosecond time-dependent yields of several product ions following ultrafast strong-field ionization represent spectroscopic signatures that elucidate their mechanism of formation and identify the intermediate(s) they originate from. Experiments on endo-dicyclopentadiene show that vibrational frequencies from various intermediates are mapped onto their resulting products. Aided by ab initio methods, we identify the vibrational modes of both the cleaved and intact molecular ion intermediates. These results confirm stepwise and concerted fragmentation pathways of the dicyclopentadiene ion. This study highlights the power of tracking the femtosecond dynamics of all product ions simultaneously and sheds further light onto one of the fundamental reaction mechanisms in mass spectrometry, the retro-Diels Alder reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The ABC of RPV: classification of R-parity violating signatures at the LHC for small couplings

We perform a classification of all potential supersymmetric R-parity violating signatures at the LHC to address the question: are existing bounds on supersymmetric models robust, or are there still signatures not covered by existing searches, allowing LHC scale supersymmetry to be hiding? We analyze all possible scenarios with one dominant RPV trilinear coupling at a time, allowing for arbitrary LSPs and mass spectra. We consider direct production of the LSP, as well as production via gauge-cascades, and find 6 different experimental signatures for the $LL\overline{E}$-case, 6 for the $LQ\overline{D}$-case, and 5 for the $\overline{U}$ $\overline{D}$ $\overline{D}$-case; together these provide complete coverage of the RPV-MSSM landscape. This set of signatures is confronted with the existing searches by ATLAS and CMS. We find all signatures have been covered at the LHC, although not at the sensitivity level needed to probe the direct production of all LSP types. For the case of a dominant $LL\overline{E}$-operator, we use CheckMATE to quantify the current lower bounds on the supersymmetric masses and find the limits to be comparable to or better than the R-parity conserving case. Our treatment can be easily extended to scenarios with more than one non-zero RPV coupling.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diffusion mechanism and the thermal stability of fluorine ions in GaN after ion implantation

The diffusion mechanisms of fluorine ions in GaN are investigated by means of time-of-flight secondary ion mass spectrometry. Instead of incorporating fluorine ions close to the sample surface by fluorine plasma treatment, fluorine ion implantation with an energy of 180 keV is utilized to implant fluorine ions deep into the GaN bulk, preventing the surface effects from affecting the data analysis. It is found that the diffusion of fluorine ions in GaN is a dynamic process featuring an initial out-diffusion followed by in- diffusion and the final stabilization. A vacancy-assisted diffusion model is proposed to account for the experimental observations, which is also consistent with results on molecular dynamic simulation. Fluorine ions tend to occupy Ga vacancies induced by ion implantation and diffuse to vacancy rich regions. The number of continuous vacancy chains can be significantly reduced by a dynamic thermal annealing process. As a result, strong local confinement and stabilization of fluorine ions can be obtained in GaN crystal, suggesting excellent thermal stability of fluorine ions for device applications.

36 MATERIALS SCIENCE↗

Thermal conductivity and Seebeck coefficients of icosahedral boron arsenide films on silicon carbide

The thermal conductivity of icosahedral boron arsenide (B{sub 12}As{sub 2}) films grown on (0001) 6H-SiC substrates by chemical vapor deposition was studied by the 3{omega} technique. The room temperature thermal conductivity decreased from 27.0 to 15.3 W/m K as the growth temperature was decreased from 1450 to 1275 deg. C. This is mainly attributed to the differences in the impurity concentration and microstructure, determined from secondary ion mass spectrometry and high resolution transmission electron microscopy, respectively. Callaway's theory was applied to calculate the temperature-dependent thermal conductivity, and the results are in good agreement with the experimental data. Seebeck coefficients were determined as 107 {mu}V/K and 136 {mu}V/K for samples grown at 1350 deg. C with AsH{sub 3}/B{sub 2}H{sub 6} flow ratio equals to 1:1 and 3:5, respectively.

36 MATERIALS SCIENCE↗

Activatino of Erbium Films for Hydrogen Storage

Hydriding of metals can be routinely performed at high temperature in a rich hydrogen atmosphere. Prior to the hydrogen loading process, a thermal activation procedure is required to promote facile hydrogen sorption into the metal. Despite the wide spread utilization of this activation procedure, little is known about the chemical and electronic changes that occur during activation and how this thermal pretreatment leads to increased rates of hydrogen uptake. This study utilized variable kinetic energy X-ray photoelectron spectroscopy to interrogate the changes during in situ thermal annealing of erbium films, with results confirmed by time-of-flight secondary ion mass spectrometry and low energy ion scattering. Activation can be identified by a large increase in photoemission between the valence band edge and the Fermi level and appears to occur over a two stage process. The first stage involves desorption of contaminants and recrystallization of the oxide, initially impeding hydrogen loading. Further heating overcomes the first stage and leads to degradation of the passive surface oxide leading to a bulk film more accessible for hydrogen loading.

08 HYDROGEN↗