Search NASA⌕ Search

SEARCH · Search NASA

Results for “Maximum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Do Maximum Intensity Projection Images Truly Capture Tumor Motion?

Purpose: For the treatment of patients with lung cancer, internal target volume frequently is determined by using maximum intensity projection (MIP) images generated by means of four-dimensional computed tomography (4D-CT). To check the accuracy of MIPs for various target motions, especially for targets moving irregularly, we performed phantom studies using a programmable dynamic lung phantom. Methods and Materials: A custom-built programmable lung phantom was used to simulate irregular target motions along the superior-inferior direction. After scanning in helical mode using 4D-CT, reconstructed phase and MIP images were imported into the Pinnacle 8.0 treatment planning system for image analysis. Results: For all regular periodic target motions with constant amplitude and period, the measured MIP target span along the superior-inferior direction was accurate within 2-3 mm of the real target motion span. For irregular target motions with varying amplitudes and periods, the measured MIP target span systematically underrepresented the real range of target motion by more than 1 cm in some cases. The difference between measured MIP target span and real target span decreased as the target moved faster. We associate these discrepancies with the fact that current reconstruction algorithms of commercial 4D-CT are based on phase binning. Conclusions: According to our phantom measurements, MIP accurately reflects the range of target motion for regular target motion. However, it generally underestimates the range of target motion when the motion is irregular in amplitude and periodicity. Clinical internal target volume determination using MIP requires caution, especially when there is breathing irregularity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Maximum vs. Mono Androgen Blockade and the Risk of Recurrence in Men With Localized Prostate Cancer Undergoing Brachytherapy

Purpose: We examined whether maximum androgen blockade (MAB) is associated with a decreased recurrence risk vs. single-agent androgen suppression (monotherapy) for men undergoing brachytherapy (BT) for localized prostate cancer. Methods and Materials: Data from 223 men in Cancer of the Prostate Strategic Urologic Research Endeavor database who received androgen deprivation therapy (ADT) concurrent with BT for intermediate- or high-risk prostatic adenocarcinoma were included; 159 (71%) received MAB, and 64 (29%) monotherapy (luteinizing hormone-releasing hormone agonist or anti-androgen alone). Cox regression analysis was performed to assess whether the choice of ADT was associated with disease recurrence adjusting for known prognostic factors. Results: Men who received MAB had similar Gleason scores, T categories, and pretreatment prostate-specific antigen as those who received monotherapy. After a median follow-up of 49 months, the use of MAB was not associated with a decrease in the risk recurrence (p = 0.72), after adjusting for known prognostic factors. A higher PSA at diagnosis (p = 0.03) and younger age at diagnosis (p < 0.01) were associated with increased recurrence risk. The 3-year recurrence free survival was 76% for patients in both monotherapy and MAB groups. Conclusions: There are varied practice patterns in physicians' choice of the extent of concurrent ADT when used with brachytherapy for men with intermediate- or high-risk prostate cancer. Given a lack of demonstrated superiority from either ADT choice, both appear to be reasonable options.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Maximum Standardized Uptake Value From Staging FDG-PET/CT Does not Predict Treatment Outcome for Early-Stage Non-Small-Cell Lung Cancer Treated With Stereotactic Body Radiotherapy

Purpose: To perform a retrospective review to determine whether maximum standardized uptake values (SUV{sub max}) from staging 2-deoxy-2- [{sup 18}F] fluoro-D-glucose (FDG) positron emission tomography/computed tomography (PET/CT) studies are associated with outcomes for early-stage non-small-cell lung cancer (NSCLC) treated with stereotactic body radiotherapy (SBRT). Methods and Materials: Seventy-two medically inoperable patients were treated between October 17, 2003 and August 17, 2007 with SBRT for T1-2N0M0 NSCLC. SBRT was administered as 60 Gy in 3 fractions, 50 Gy in 5 fractions, or 50 Gy in 10 fractions using abdominal compression and image-guided SBRT. Cox proportional hazards regression was performed to determine whether PET SUV{sub max} and other variables influenced outcomes: mediastinal failure (MF), distant metastases (DM), and overall survival (OS). Results: Biopsy was feasible in 49 patients (68.1%). Forty-nine patients had T1N0 disease, and 23 had T2N0 disease. Median SUV{sub max} was 6.55 (range, 1.5-21). Median follow-up was 16.9 months (range, 0.1-37.9 months). There were 3 local failures, 8 MF, 19 DM, and 30 deaths. Two-year local control, MF, DM, and OS rates were 94.0%, 10.4%, 30.1%, and 61.3%, respectively. In univariate analysis, PET/CT SUV{sub max}, defined either as a continuous or dichotomous variable, did not predict for MF, DM, or OS. On multivariable analysis, the only predictors for overall survival were T1 stage (hazard ratio = 0.331 [95% confidence interval, 0.156-0.701], p = 0.0039) and smoking pack-year history (hazard ratio = 1.015 [95% confidence interval, 1.004-1.026], p = 0.0084). Conclusions: Pretreatment PET SUV{sub max} did not predict for MF, DM, or OS in patients treated with SBRT for early-stage NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phantom and Clinical Study of Differences in Cone Beam Computed Tomographic Registration When Aligned to Maximum and Average Intensity Projection

Purpose: To determine whether maximum or average intensity projection (MIP or AIP, respectively) reconstructed from 4-dimensional computed tomography (4DCT) is preferred for alignment to cone beam CT (CBCT) images in lung stereotactic body radiation therapy. Methods and Materials: Stationary CT and 4DCT images were acquired with a target phantom at the center of motion and moving along the superior–inferior (SI) direction, respectively. Motion profiles were asymmetrical waveforms with amplitudes of 10, 15, and 20 mm and a 4-second cycle. Stationary CBCT and dynamic CBCT images were acquired in the same manner as stationary CT and 4DCT images. Stationary CBCT was aligned to stationary CT, and the couch position was used as the baseline. Dynamic CBCT was aligned to the MIP and AIP of corresponding amplitudes. Registration error was defined as the SI deviation of the couch position from the baseline. In 16 patients with isolated lung lesions, free-breathing CBCT (FBCBCT) was registered to AIP and MIP (64 sessions in total), and the difference in couch shifts was calculated. Results: In the phantom study, registration errors were within 0.1 mm for AIP and 1.5 to 1.8 mm toward the inferior direction for MIP. In the patient study, the difference in the couch shifts (mean, range) was insignificant in the right-left (0.0 mm, ≤1.0 mm) and anterior–posterior (0.0 mm, ≤2.1 mm) directions. In the SI direction, however, the couch position significantly shifted in the inferior direction after MIP registration compared with after AIP registration (mean, −0.6 mm; ranging 1.7 mm to the superior side and 3.5 mm to the inferior side, P=.02). Conclusions: AIP is recommended as the reference image for registration to FBCBCT when target alignment is performed in the presence of asymmetrical respiratory motion, whereas MIP causes systematic target positioning error.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Audio-Visual Biofeedback Does Not Improve the Reliability of Target Delineation Using Maximum Intensity Projection in 4-Dimensional Computed Tomography Radiation Therapy Planning

Purpose: To investigate whether coaching patients' breathing would improve the match between ITV{sub MIP} (internal target volume generated by contouring in the maximum intensity projection scan) and ITV{sub 10} (generated by combining the gross tumor volumes contoured in 10 phases of a 4-dimensional CT [4DCT] scan). Methods and Materials: Eight patients with a thoracic tumor and 5 patients with an abdominal tumor were included in an institutional review board-approved prospective study. Patients underwent 3 4DCT scans with: (1) free breathing (FB); (2) coaching using audio-visual (AV) biofeedback via the Real-Time Position Management system; and (3) coaching via a spirometer system (Active Breathing Coordinator or ABC). One physician contoured all scans to generate the ITV{sub 10} and ITV{sub MIP}. The match between ITV{sub MIP} and ITV{sub 10} was quantitatively assessed with volume ratio, centroid distance, root mean squared distance, and overlap/Dice coefficient. We investigated whether coaching (AV or ABC) or uniform expansions (1, 2, 3, or 5 mm) of ITV{sub MIP} improved the match. Results: Although both AV and ABC coaching techniques improved frequency reproducibility and ABC improved displacement regularity, neither improved the match between ITV{sub MIP} and ITV{sub 10} over FB. On average, ITV{sub MIP} underestimated ITV{sub 10} by 19%, 19%, and 21%, with centroid distance of 1.9, 2.3, and 1.7 mm and Dice coefficient of 0.87, 0.86, and 0.88 for FB, AV, and ABC, respectively. Separate analyses indicated a better match for lung cancers or tumors not adjacent to high-intensity tissues. Uniform expansions of ITV{sub MIP} did not correct for the mismatch between ITV{sub MIP} and ITV{sub 10}. Conclusions: In this pilot study, audio-visual biofeedback did not improve the match between ITV{sub MIP} and ITV{sub 10}. In general, ITV{sub MIP} should be limited to lung cancers, and modification of ITV{sub MIP} in each phase of the 4DCT data set is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pretreatment [{sup 18}F]-fluoro-2-deoxy-glucose Positron Emission Tomography Maximum Standardized Uptake Value as Predictor of Distant Metastasis in Early-Stage Non-Small Cell Lung Cancer Treated With Definitive Radiation Therapy: Rethinking the Role of Positron Emission Tomography in Personalizing Treatment Based on Risk Status

Purpose: The aim of this study was to determine whether the preradiation maximum standardized uptake value (SUV{sub max}) of the primary tumor for [{sup 18}F]-fluoro-2-deoxy-glucose positron emission tomography (FDG-PET) has a prognostic significance in patients with Stage T1 or T2N0 non-small cell lung cancer (NSCLC) treated with curative radiation therapy, whether conventional or stereotactic body radiation therapy (SBRT). Methods and Materials: Between January 2007 and December 2011, a total of 163 patients (180 tumors) with medically inoperable histologically proven Stage T1 or T2N0 NSCLC and treated with radiation therapy (both conventional and SBRT) were entered in a research ethics board approved database. All patients received pretreatment FDG-PET / computed tomography (CT) at 1 institution with consistent acquisition technique. The medical records and radiologic images of these patients were analyzed. Results: The overall survival at 2 years and 3 years for the whole group was 76% and 67%, respectively. The mean and median SUV{sub max} were 8.1 and 7, respectively. Progression-free survival at 2 years with SUV{sub max} <7 was better than that of the patients with tumor SUV{sub max} ≥7 (67% vs 51%; P=.0096). Tumors with SUV{sub max} ≥7 were associated with a worse regional recurrence-free survival and distant metastasis-free survival. In the multivariate analysis, SUV{sub max} ≥7 was an independent prognostic factor for distant metastasis-free survival. Conclusion: In early-stage NSCLC managed with radiation alone, patients with SUV{sub max} ≥7 on FDG-PET / CT scan have poorer outcomes and high risk of progression, possibly because of aggressive biology. There is a potential role for adjuvant therapies for these high-risk patients with intent to improve outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Change of Maximum Standardized Uptake Value Slope in Dynamic Triphasic [{sup 18}F]-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Distinguishes Malignancy From Postradiation Inflammation in Head-and-Neck Squamous Cell Carcinoma: A Prospective Trial

Purpose: To evaluate dynamic [{sup 18}F]-fluorodeoxyglucose (FDG) uptake methodology as a post–radiation therapy (RT) response assessment tool, potentially enabling accurate tumor and therapy-related inflammation differentiation, improving the posttherapy value of FDG–positron emission tomography/computed tomography (FDG-PET/CT). Methods and Materials: We prospectively enrolled head-and-neck squamous cell carcinoma patients who completed RT, with scheduled 3-month post-RT FDG-PET/CT. Patients underwent our standard whole-body PET/CT scan at 90 minutes, with the addition of head-and-neck PET/CT scans at 60 and 120 minutes. Maximum standardized uptake values (SUV{sub max}) of regions of interest were measured at 60, 90, and 120 minutes. The SUV{sub max} slope between 60 and 120 minutes and change of SUV{sub max} slope before and after 90 minutes were calculated. Data were analyzed by primary site and nodal site disease status using the Cox regression model and Wilcoxon rank sum test. Outcomes were based on pathologic and clinical follow-up. Results: A total of 84 patients were enrolled, with 79 primary and 43 nodal evaluable sites. Twenty-eight sites were interpreted as positive or equivocal (18 primary, 8 nodal, 2 distant) on 3-month 90-minute FDG-PET/CT. Median follow-up was 13.3 months. All measured SUV endpoints predicted recurrence. Change of SUV{sub max} slope after 90 minutes more accurately identified nonrecurrence in positive or equivocal sites than our current standard of SUV{sub max} ≥2.5 (P=.02). Conclusions: The positive predictive value of post-RT FDG-PET/CT may significantly improve using novel second derivative analysis of dynamic triphasic FDG-PET/CT SUV{sub max} slope, accurately distinguishing tumor from inflammation on positive and equivocal scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Compression of tokamak boundary plasma simulation data using a maximum volume algorithm for matrix skeleton decomposition

This report demonstrates satisfactory data compression of SOLPS-ITER simulation output ranging from 2D fields, 1D profiles, and 0D scalar variables with a novel matrix decomposition approach. The singular value decomposition (SVD) scales poorly for large matrix sizes and is unsuited to the application on high dimensional data common to fusion plasma physics simulation. In this work, we employ the columns-submatrix-rows (CUR) matrix factorization technique in order to compute a low-rank approximation up to two orders of magnitude faster than the SVD, but within a nominal L2-norm relative error of ε = 10 –2 . In addition, the CUR approach maintains the original format of the data, in its extracted columns and rows, allowing for interpretable data storage at the original resolution of the simulation. We utilize an iterative algorithm to compute the CUR decomposition of simulation output by maximizing the volume, or linearly independent information content, of a low-rank submatrix contained within the data. Experiments over $\textit{n} × \textit{n}$ randomized test matrices with embedded rank-deficient features show that this maximum volume implementation of CUR matrix approximation has reduced asymptotic computational complexity on the order of n compared to the SVD, which scales approximately as $n^3$. These results show that the CUR technique can be used to effectively select time step snapshots (columns) of over 140 SOLPS-ITER output variables and the associated discretized coordinate timeseries (rows) allowing for reconstruction of the complete simulation dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Maximum Reasonable Radioxenon Releases from Medical Isotope Production Facilities and Their Effect on Monitoring Nuclear Explosions

Fission gases such as 133Xe are used extensively for monitoring the world for signs of nuclear testing in systems such as the International Monitoring System (IMS). These gases are also produced by nuclear reactors and by fission production of 99Mo for medical use. Recently, medical isotope production facilities have been identified as the major contributor to the background of radioactive xenon isotopes (radioxenon) in the atmosphere (Saey, et al., 2009). These releases pose a potential future problem for monitoring nuclear explosions if not addressed. As a starting point, a maximum acceptable daily xenon emission rate was calculated, that is both scientifically defendable as not adversely affecting the IMS, but also consistent with what is possible to achieve in an operational environment. This study concludes that an emission of 5×109 Bq/day from a medical isotope production facility would be both an acceptable upper limit from the perspective of minimal impact to monitoring stations, but also appears to be an achievable limit for large isotope producers.

07 ISOTOPE AND RADIATION SOURCES↗

Maximum energy product at elevated temperatures for hexagonal strontium ferrite (SrFe12O19) magnet

The electronic structure of hexagonal strontium ferrite (SrFe12O19) was calculated based on the density functional theory (DFT) and generalized gradient approximation (GGA). The GGA+U method was used to improve the description of localized Fe 3d electrons. Three different effective U (U-eff) values of 3.7, 7.0, and 10.3 eV were used to calculate three sets of exchange integrals for 21 excited states. We then calculated the temperature dependence of magnetic moments m(T) for the five sublattices (2a, 2b, 12k, 4f(1), and 4f(2)) using the exchange integrals. The m(T) of the five sublattices are inter related to the nearest neighbors, where the spins are mostly anti-ferromagnetically coupled. The five sublattice m(T) were used to ()brain the saturation magnetization M-s(T) of SrFe12O19, which is in good agreement with the experimental values. The temperature dependence of maximum energy product. ((BII)(max)(T)) was calculated using the calculated M-s(T). (C) 2013 Elsevier B.V. All rights reserved.

Park, J↗

Anisotropic broadening of XRD peaks of α′-Fe: Williamson-Hall and Warren-Averbach analysis using full width at half maximum (FWHM) and integral breadth (IB)

Highlights: • There is a limited increase in the dislocation density in the martensite from the center to the surface of the specimen. • Both FWHM and Integral Breadth (IB) follows Conventional-WH model for undeformed material. • Significant perturbation from linearity observed for higher order peaks in deformed material • Between FWHM and IB-approach, the modified-WH model provides a better response with the FWHM-approach than IB-approach. - Abstract: The anisotropic broadening of the X-ray diffraction (XRD) peaks of shear deformed martensite (α′-Fe), using both full-width at half-maximum (FWHM) and integral breadth (IB), has been studied following conventional and modified Williamson-Hall (WH) and Warren-Averbach (WA) analysis. The crystallographic study reveals limited plastic deformation of martensite (α′) within a shallow depth from the shear surface, as indicated by marginal change in the character and density of dislocation, showing the inability of the α′-phase to accommodate the strain energy of shear deformation. More importantly, the study reveals significant perturbation of modified-WH and WA model, when IB is considered for size and strain analysis, especially for higher order peaks, whereas, FWHM shows reasonably good agreement with the above mentioned models for the range of diffraction spectrum considered.

36 MATERIALS SCIENCE↗

Meta-equilibrium transition microstructure for maximum austenite stability and minimum hardness in a Ti-stabilized supermartensitic stainless steel

We report that the maximization of stable reverted austenite at room temperature through inter-critical tempering is a widely used method to reduce hardness in supermartensitic stainless steels. Nevertheless, partial martensitic transformation might occur due to insufficient compositional stabilization. In this work, we conducted a time-resolved triple-step inter-critical tempering, specially designed to obtain maximum austenite stability and minimum hardness through the progressive suppression of the martensitic transformation. The mechanism behind the progressive increase in stable reverted austenite was the generation of a meta-equilibrium state, which imposed a limit in both high temperature austenite reversion and room temperature austenite stabilization. Such limit corresponded to the high temperature volume fraction of austenite, obtained right before cooling from the first cycle. Additionally, this effect was associated to the Ni-rich fresh martensite laths acting as local Ni compositional pockets, providing site-specific austenite reversion; and to the suppression of any additional nucleation at the Ni-poor matrix as the T0 temperature for austenite reversion was strongly increased. The softening mechanism was mainly controlled by the carbon arrest effect by the precipitation of Ti (C, N), which was completed after the first tempering cycle. Nevertheless, maximizing reverted austenite and suppressing fresh martensite at room temperature did not result in additional hardness reductions.

36 MATERIALS SCIENCE↗

Spectroscopy of neutron-rich {sup 168,170}Dy: Yrast band evolution close to the N{sub p}N{sub n} valence maximum

The yrast sequence of the neutron-rich dysprosium isotope {sup 168}Dy has been studied using multinucleon transfer reactions following collisions between a 460-MeV {sup 82}Se beam and an {sup 170}Er target. The reaction products were identified using the PRISMA magnetic spectrometer and the gamma rays detected using the CLARA HPGe-detector array. The 2{sup +} and 4{sup +} members of the previously measured ground-state rotational band of {sup 168}Dy have been confirmed and the yrast band extended up to 10{sup +}. A tentative candidate for the 4{sup +}->2{sup +} transition in {sup 170}Dy was also identified. The data on these nuclei and on the lighter even-even dysprosium isotopes are interpreted in terms of total Routhian surface calculations and the evolution of collectivity in the vicinity of the proton-neutron valence product maximum is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a New Fast Shower Maximum Detector Based on Microchannel Plates Photomultipliers (MCP-PMT) as an Active Element

One possibility to make a fast and radiation resistant shower maximum (SM) detector is to use a secondary emitter as an active element. We present below test beam results, obtained with different types of photodetectors based on microchannel plates (MCPs) as the secondary emitter. We performed the measurements at the Fermilab Test Beam Facility with 120GeV proton beam and 12GeV and 32GeV secondary beams. The goal of the measurement with 120GeV protons was to determine time resolution for minimum ionizing particles (MIPs). The SM time resolution we obtained for this new type of detector is at the level of 20-30ps. We estimate that a significant contribution to the detector response originates from secondary emission of the MCP. This work can be considered as the first step in building a new type of calorimeter based on this principle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detailed comparison of renormalization scale-setting procedures based on the principle of maximum conformality

The Principle of Maximum Conformality (PMC), which generalizes the conventional Gell-Mann-Low method for scale-setting in perturbative QED to non-Abelian QCD, provides a rigorous method for achieving unambiguous scheme-independent, fixed-order predictions for physical observables consistent with the principles of the renormalization group. In addition to the original multi-scale-setting approach (PMCm), two variations of the PMC have been proposed to deal with ambiguities associated with the uncalculated higher order terms in the pQCD series, i.e. the single-scale-setting approach (PMCs) and the procedures based on ``intrinsic conformality" (PMC ∞ ). In this paper, we will give a detailed comparison of these PMC approaches by comparing their predictions for three important quantities R e+e– , R τ , and $Γ(H→b\bar{b}$) up to four-loop pQCD corrections. The PMCs approach determines an overall effective running coupling α s (Q) by the recursive use of the renormalization group equation, whose argument Q represents the actual momentum flow of the process. Our numerical results show that the PMCs method, which involves a somewhat simpler analysis, can serve as a reliable substitute for the full multi-scale PMCm method, and that it leads to more precise pQCD predictions with small residual scale dependence.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The maximum carboxylation rate of Rubisco affects CO2 refixation in temperate broadleaved forest trees

Mesophyll resistance to CO 2 diffusion (rm) and the maximum carboxylation rate of Rubisco (Vcmax) affect photosynthetic rates, and can potentially also influence the percentage of respiratory and photorespiratory CO 2 being refixated (Pr) by mesophyll cells. Here we investigated how various leaf anatomical traits (e.g. leaf mass per area [LMA] and leaf dry matter content [LDMC]) influenced rm in leaves of mature forest trees. We further explored how rm and Vcmax in turn affected Pr, and if these traits varied among species and leaves along a light gradient. Photosynthetic CO 2 response of leaves grown in high-, medium-, and low-light environments was measured, from Pinus sylvestris [Scots pine], Picea abies [Norway spruce], Quercus robur [English oak], and Betula pendula [Silver birch] in southern Sweden. A modified version of the Farquhar-von Caemmerer-Berry model was fitted to the leaf gas exchange data to estimate Vcmax, rm and Pr. We found that of all leaf traits measured, only LMA for Q. robur was significantly higher in leaves from high-light environments. When comparing species, both rm and LMA were significantly higher in the conifers, and rm had a negative correlation with Vcmax. We found that Pr was similar between different species and functional groups, with an average of 73.2% (and SD of ±10.4) across all species. There was a strong, positive correlation between Pr and Vcmax in broadleaves, and we hypothesise that this effect might derive from a higher CO 2 drawdown near Rubisco in leaves with high Vcmax.

59 BASIC BIOLOGICAL SCIENCES↗

A mechanistic understanding of oxygen isotopic changes in the Western United States at the Last Glacial Maximum

At the Last Glacial Maximum (LGM), records suggest drier conditions in the northwest United States and wetter conditions in the southwest United States relative to present-day as well as widespread changes in the isotopic composition of water. However, the mechanisms responsible for these changes remain ambiguous. Here, we explore differences in western United States hydroclimate between the LGM and preindustrial with a water isotope tracer enabled Earth System Model. We then use proxy forward models to compare simulated and recorded δ 18 O in speleothems. We find that the pattern of hydroclimate response in the western United States at the LGM relates to a combination of 1) increased frequency and southward shifted wintertime extratropical cyclones in the North Pacific, 2) greater rainout of moisture as it moves over the continent, and 3) reduced evaporation in the cooler LGM climate. The simulated lower δ 18 O of precipitation at the LGM relates predominantly to an increase in cool season moisture removal efficiency, with a secondary contribution from relatively more cool season precipitation. Both surface temperatures and North American ice sheets contribute to these hydroclimate changes at the LGM. Comparisons between δ 18 O from proxy forward models and speleothem records in the western United States show general agreement at the LGM, with increasing depletion moving towards the continental interior. Finally, this study highlights the similarities and differences between hydrologic and δ 18 O changes at the LGM and emphasizes the utility of model-proxy comparison for interpretation.

54 ENVIRONMENTAL SCIENCES↗

Climate reconstructions for the Last Glacial Maximum from a simple cirque glacier in Fiordland, New Zealand

Mountain glacier records offer important constraints on the timing and magnitude of climate variability during the last glacial cycle. Existing moraine chronologies from the central Southern Alps indicate maximum ice extent was achieved during marine isotope stages 3–4, followed by repeated advances of similar, but gradually declining extent during marine isotope stage 2, until onset of the glacial termination. Questions remain over the precise role of climate in driving these changes, as most existing moraine chronologies come from large, complex former valley glacier systems, where non-climatic influences such as changing bed topography and proglacial lake formation may have influenced glacier length changes. In this work, we address this problem via a new cosmogenic 10Be chronology and equilibrium line altitude reconstruction from a cirque glacier situated in Fiordland, New Zealand. Our chronology shows moraine deposition at 32 ± 11 ka, 18.7 ± 0.2 ka, 18.1 ± 0.1 ka, and c. 17.2 ± 0.3 ka. The simple geometry of the former glacier supports the role of climate in driving a net decline of regional ice volume during marine isotope stages 3–2. Close spacing and good preservation of the 19–17 ka moraines permits 2D glacier reconstruction which suggests the equilibrium line altitude remained depressed by c.1130 m (equivalent to 5.8 ± 0.6 °C colder than present) during this interval. Onset of warming after 17.2 ± 0.2 ka is consistent with climate proxy evidence for a sustained southward shift in the southern westerly winds, which may have promoted deglaciation via shifting ocean currents and promoting increases in atmospheric carbon dioxide.

54 ENVIRONMENTAL SCIENCES↗