Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Uncertainty analysis of axial temperature and Seebeck coefficient measurements

Experimental investigations of solid materials at elevated temperatures rely on the optimized thermal design of the measurement system, as radiation becomes a predominant source of heat loss which can lead to large uncertainty in measured temperature and related physical properties of a test sample. Advancements in surface temperature measurements have reduced thermal losses arising from the cold-finger effect using axially inserted thermocouples and from radiation using shields or other thermal guards. The leading technology for temperature sensing at temperatures up to ~900 °C makes use of these design features for measuring thermopower, yet uncertainty analysis estimation of this technique is not known. This study makes use of finite element modeling to determine spatial temperature distributions to obtain the upper limit of confidence expected for the axially inserted thermocouple approach when a heated radiation shield is incorporated into the design. Using an axially inserted thermocouple to measure the sample surface temperature, the temperature variations across the sample hot and cold surfaces at 900 °C for a temperature drop of 0, 5, and 10 °C are calculated to be as low as 0.02, 0.21, and 0.41 °C, respectively, when a heated radiation shield is employed. Uniform temperature distribution on the thermocouple cross-wire geometry indicates that the axial thermocouple measurement design is indeed effective for suppressing the cold-finger effect. Using a heated radiation shield is found to significantly reduce the temperature gradient across the thermocouples.

30 DIRECT ENERGY CONVERSION↗

DESI DR1 Ly α 1D power spectrum: Validation of estimators

The Data Release 1 (DR1) of the Dark Energy Spectroscopic Instrument (DESI) is the largest sample to date for small-scale Lyα forest cosmology, accessed through its one-dimensional power spectrum (P 1D ). The Lyα forest P 1D is extracted from quasar spectra that are highly inhomogeneous (both in wavelength and between quasars) in noise properties due to intrinsic properties of the quasar, atmospheric and astrophysical contamination, and also sensitive to low-level details of the spectral extraction pipeline. We employ two estimators in DR1 analysis to measure P 1D : the optimal estimator and the fast Fourier transform (FFT) estimator. To ensure robustness of our DR1 measurements, we validate these two power spectrum and covariance matrix estimation methodologies against the challenging aspects of the data. First, using a set of 20 synthetic 1D realizations of DR1, we derive the masking bias corrections needed for the FFT estimator and the continuum fitting bias needed for both estimators. We demonstrate that both estimators, including their covariances, are unbiased with these corrections using the Kolmogorov-Smirnov test. Second, we substantially extend our previous suite of CCD image simulations to include 675,000 quasars, allowing us to accurately quantify the pipeline's performance. This set of simulations reveals biases at the highest k values, corresponding to a resolution error of a few percent. We base the resolution systematics error budget of DR1 P 1D on these values, but do not derive corrections from them since the simulation fidelity is insufficient for precise corrections.

Lyman alpha forest↗

Rapid measurement of RH-dependent aerosol hygroscopic growth using a humidity-controlled fast integrated mobility spectrometer (HFIMS)

Abstract. The ability of aerosol particles to uptake water (hygroscopic growth) is an important determinant of aerosol optical properties and radiative effects. Aerosol hygroscopic growth is traditionally measured by humidified tandem differential mobility analyzers (HTDMA), in which size-selected dry particles are exposed to elevated relative humidity (RH), and the size distribution of humidified particles is subsequently measured using a scanning mobility particle sizer. As a scanning mobility particle sizer can measure only one particle size at a time, HTDMA measurements are time consuming, and ambient measurements are often limited to a single RH level. Pinterich et al. (2017b) showed that fast measurements of aerosol hygroscopic growth are possible using a humidity-controlled fast integrated mobility spectrometer (HFIMS). In HFIMS, the size distribution of humidified particles is rapidly captured by a water-based fast integrated mobility spectrometer (WFIMS), leading to a factor of ∼10 increase in measurement time resolution. In this study we present a prototype HFIMS that extends fast hygroscopic growth measurements to a wide range of atmospherically relevant RH values, allowing for more comprehensive characterizations of aerosol hygroscopic growth. A dual-channel humidifier consisting of two humidity conditioners in parallel is employed such that aerosol RH can be quickly stepped among different RH levels by sampling from alternating conditioners. The measurement sequence is also optimized to minimize the transition time between different particle sizes. The HFIMS is capable of measuring aerosol hygroscopic growth of six particle diameters under five RH levels ranging from 20 % to 85 % (30 separate measurements) every 25 min. The performance of this HFIMS is characterized and validated using laboratory-generated ammonium sulfate aerosol standards. Measurements of ambient aerosols are shown to demonstrate the capability of HFIMS to capture the rapid evolution of aerosol hygroscopic growth and its dependence on both size and RH.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-328: Dosimetric Impact of Cobalt-Chrome Stabilization Hardware in Paraspinal Radiation Therapy

Purpose: Due to saturation, high density materials Result in an apparent density of 3.2 g/cm{sup 3} in CT images. The true density of traditional titanium stabilization rods (∼4.4 g/cm{sup 3}) is typically ignored in treatment planning. This may not be acceptable for new cobalt-chrome rods with a density of 8.5 g/cm{sup 3}. This study reports the dosimetric impact of cobalt-chrome rods in paraspinal radiotherapy. Methods: For titanium and cobalt-chrome rods, two planning studies were done for both IMRT and VMAT in Varian Eclipse using AAA. 1) The effect of planning without assigning the true rod density was assessed by comparing plans generated with the apparent density and recalculated with the true density for titanium and cobalt-chrome. 2) To test if TPS can compensate for high density rods during optimization. Furthermore, TPS calculation accuracy was verified using MapCheck for a single 20 x 10 cm{sup 2} field. The MapCheck was incrementally shifted to achieve measurement resolution of 1 mm. Results: PTV coverage was ∼0.3% and ∼4.7% lower in plans that were recalculated with the true rod density of titanium and cobalt-chrome, respectively. PTV coverage can be maintained if the correct density is used in optimization. Measurements showed that TPS overestimated the dose locally by up to 11% for cobalt-chrome rods and up to 4% for titanium rods if the density is incorrect. With density corrected, maximum local differences of 6% and 3% were seen for cobalt-chrome and titanium rods, respectively. At 2 cm beneath a rod, electrons scattered from the side of the rod increased the lateral dose and diminished as depth increases. TPS was not able to account for this effect properly even with the true rod density assigned. Conclusion: Neglecting the true density of cobalt-chrome rods can cause under coverage to the PTV. Assigning the correct density during treatment planning can minimize unexpected decrease in PTV dose.

60 APPLIED LIFE SCIENCES↗

Risk-Averse Control of Fractional Diffusion with Uncertain Exponent

In this paper, we introduce and analyze a new class of optimal control problems constrained by elliptic equations with uncertain fractional exponents. We utilize risk measures to formulate the resulting optimization problem. We develop a functional analytic framework, study the existence of solution and rigorously derive the first-order optimality conditions. Additionally, we employ a sample-based approximation for the uncertain exponent and the finite element method to discretize in space. Further, we prove the rate of convergence for the optimal risk neutral controls when using quadrature approximation for the uncertain exponent and conclude with illustrative examples.

finite element method↗

Information theory optimization of signals from small-angle scattering measurements

Small-angle X-ray scattering (SAXS) of particles in solution informs on the conformational states and assemblies of biological macromolecules (bioSAXS) outside of cryo- and solid-state conditions. In bioSAXS, the SAXS measurement under dilute conditions is resolution limited, and through an inverse Fourier transform, the measured SAXS intensities directly relate to the physical space occupied by the particles via the P (r)-distribution. Yet, this inverse transform of SAXS data has been historically cast as an ill-posed, ill-conditioned problem requiring an indirect approach. Here, we show that through the applications of matrix and information theories, the inverse transform of SAXS intensity data is a well-conditioned problem. The so-called ill-conditioning of the inverse problem is directly related to the Shannon number. By exploiting the oversampling enabled by modern detectors, a direct inverse Fourier transform of the SAXS data is possible, provided the recovered information does not exceed the Shannon number. The Shannon limit corresponds to the maximum number of significant singular values that can be recovered in a SAXS experiment, suggesting this relationship is a fundamental property of band-limited inverse integral transform problems. This correspondence reduces the complexity of the inverse problem to the Shannon limit and maximum dimension. We propose a hybrid scoring function using an information theory framework that assesses both the quality of the model-data fit as well as the quality of the recovered P (r)-distribution. The hybrid score utilizes the Akaike information criteria and Durbin-Watson statistic that considers parameter-model complexity, i.e., degrees of freedom, and the randomness of the model-data residuals. The described tests and findings extend the boundaries for bioSAXS by completing the information theory formalism initiated by Peter B. Moore to enable a quantitative measure of resolution in SAXS, robustly determine maximum dimension, and more precisely define the best parameter model appropriately representing the observed scattering data.

Rambo, Robert P. [Science and Technology Facilitie↗

Data-Driven Optimization for the Design and Control of Large-Scale Systems (LDRD Final Report)

Engineering decisions are often formulated as optimization problems such as the optimal design or control of physical systems. In these applications, the resulting optimization problems are constrained by large-scale simulations involving systems of partial differential equations (PDEs), ordinary differential equations (ODEs), and differential algebraic equations (DAEs). In addition, critical components of these systems are fraught with uncertainty, including unverifiable modeling assumptions, unknown boundary and initial conditions, and uncertain coefficients. Typically, these components are estimated using noisy and incomplete data from a variety of sources (e.g., physical experiments). The lack of knowledge of the true underlying probabilistic characterization of model inputs motivates the need for optimal solutions that are robust to this uncertainty. In this report, we introduce a framework for handling "distributional" uncertainties in the context of simulation-based optimization. This includes a novel measure discretization technique that will lead to an adaptive optimization algorithm tailored to exploit the structures inherent to simulation- based optimization.

42 ENGINEERING↗

Assumed non-persistent environmental chemicals in human adipose tissue; matrix stability and correlation with levels measured in urine and serum

The aim of this study was to (1) optimize a method for the measurement of parabens and phenols in adipose tissue, (2) evaluate the stability of chemical residues in adipose tissue samples, and (3) study correlations of these compounds in urine, serum, and adipose tissue. Samples were obtained from adults undergoing trauma surgery. Nine phenols and seven parabens were determined by isotope diluted TurboFlow-LC-MS/MS. The analytical method showed good accuracy and precision. Limits of detection (LOD) for parabens and phenols ranged from 0.05 to 1.83 ng/g tissue. Good recovery rates were found, even when biological samples remained defrosted up to 24 h. Benzophenone-3 (BP-3; range of values: 70% of adipose tissue samples, while bisphenol-A (BPA; 40% of adipose tissue samples. In general, levels were similar between adipose tissue and serum, while a correlation between adipose tissue and urine was only found for BP-3. In conclusion, adipose tissue samples in this study were found to contain environmental chemicals considered to be non-persistent, whose levels were weakly or not at all correlated with the urine burden. Therefore, adipose tissue may potentially provide additional information to that obtained from other biological matrices. Further investigations are warranted to explore whether adipose tissue might be a suitable matrix for assessment of the consequences for human health of mid/long-term exposure to these chemicals. - Highlights: • We analyzed levels of endocrine disruptors in adipose tissue, serum and urine. • We found BPA, TCS, BP-3, 2-PP and MeP in >40% of the adipose tissue samples. • Adipose tissue levels of npEDCs did not correlate with those in urine or serum. • Adipose tissue levels may have a different biological meaning.

54 ENVIRONMENTAL SCIENCES↗

Machine Learning-Based Technique for Automated Sensor Characterization

The development of novel instrumentation requires an iterative cycle with three stages: design, prototyping, and testing. Recent advancements in simulation and nanofabrication techniques have significantly accelerated the design and prototyping phases. Nonetheless, detector characterization continues to be a major bottleneck in device development. During the testing phase, a significant time investment is required to characterize the device in different operating conditions and find optimal operating parameters. The total effort spent on characterization and parameter optimization can occupy a year or more of an expert s time. In this work, we present a novel technique for automated sensor calibration that aims to accelerate the testing stage of the development cycle. This technique leverages closed-loop Bayesian optimization (BO), using real-time measurements to guide parameter selection and identify optimal operating states. We demonstrate the method with a novel low-noise CCD, showing that the machine learning-driven tool can efficiently characterize and optimize operation of the sensor in a couple of days without supervision of a device expert.

Zepeda, Cuevas [Chicago U., KICP]↗

Automating Sensor Characterization with Bayesian Optimization

The development of novel instrumentation requires an iterative cycle with three stages: design, prototyping, and testing. Recent advancements in simulation and nanofabrication techniques have significantly accelerated the design and prototyping phases. Nonetheless, detector characterization continues to be a major bottleneck in device development. During the testing phase, a significant time investment is required to characterize the device in different operating conditions and find optimal operating parameters. The total effort spent on characterization and parameter optimization can occupy a year or more of an expert's time. In this work, we present a novel technique for automated sensor calibration that aims to accelerate the testing stage of the development cycle. This technique leverages closed-loop Bayesian optimization (BO), using real-time measurements to guide parameter selection and identify optimal operating states. We demonstrate the method with a novel low-noise CCD, showing that the machine learning-driven tool can efficiently characterize and optimize operation of the sensor in a couple of days without supervision of a device expert.

Cuevas-Zepeda, Julian [Chicago U., KICP; Chicago U↗

Two-sided estimates of minimum-error distinguishability of mixed quantum states via generalized Holevo-Curlander bounds

We prove a concise factor-of-2 estimate for the failure rate of optimally distinguishing an arbitrary ensemble of mixed quantum states, generalizing work of Holevo [Theor. Probab. Appl. 23, 411 (1978)] and Curlander [Ph.D. Thesis, MIT, 1979]. A modification to the minimal principle of Cocha and Poor [Proceedings of the 6th International Conference on Quantum Communication, Measurement, and Computing (Rinton, Princeton, NJ, 2003)] is used to derive a suboptimal measurement which has an error rate within a factor of 2 of the optimal by construction. This measurement is quadratically weighted and has appeared as the first iterate of a sequence of measurements proposed by Jezek et al. [Phys. Rev. A 65, 060301 (2002)]. Unlike the so-called pretty good measurement, it coincides with Holevo's asymptotically optimal measurement in the case of nonequiprobable pure states. A quadratically weighted version of the measurement bound by Barnum and Knill [J. Math. Phys. 43, 2097 (2002)] is proven. Bounds on the distinguishability of syndromes in the sense of Schumacher and Westmoreland [Phys. Rev. A 56, 131 (1997)] appear as a corollary. An appendix relates our bounds to the trace-Jensen inequality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Retrieving the lost fermionic entanglement by partial measurement in noninertial frames

The initial entanglement shared between inertial and accelerated observers degrades due to the influence of the Unruh effect. Here, we show that the Unruh effect can be completely eliminated by the technique of partial measurement. The lost entanglement could be entirely retrieved or even amplified, which is dependent on whether the optimal strength of reversed measurement is state-independent or state-dependent. Our work provides a novel and unexpected method to recover the lost entanglement under Unruh decoherence and exhibits the ability of partial measurement as an important technique in relativistic quantum information.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimal experimental design for prediction based on push-forward probability measures

Incorporating experimental data is essential for increasing the credibility of simulation-aided decision making and design. This paper presents a method which uses a computational model to guide the optimal acquisition of experimental data to produce data-informed predictions of quantities of interest (QoI). Many strategies for optimal experimental design (OED) select data that maximize some utility that measures the reduction in uncertainty of uncertain model parameters, for example the expected information gain between prior and posterior distributions of these parameters. In this paper, we seek to maximize the expected information gained from the pushforward of an initial (prior) density to the push-forward of the updated (posterior) density through the parameter-to-prediction map. The formulation presented is based upon the solution of a specific class of stochastic inverse problems which seeks a probability density that is consistent with the model and the data in the sense that the push-forward of this density through the parameter-to-observable map matches a target density on the observable data. While this stochastic inverse problem forms the mathematical basis for our approach, we develop a one-step algorithm, focused on push-forward probability measures, that leverages inference-for-prediction to bypass constructing the solution to the stochastic inverse problem. A number of numerical results are presented to demonstrate the utility of this optimal experimental design for prediction and facilitate comparison of our approach with traditional OED.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of a new DIII-D Doppler backscattering system for higher wavenumber measurement and signal enhancement

The high density fluctuation poloidal wavenumber, k θ (k θ > 8 cm –1 , k θ ρ s > 5, ρs is the ion gyro radius using the ion sound velocity), measurement capability of a new Doppler backscattering (DBS) system at the DIII-D tokamak has been experimentally evaluated. In DBS, wavenumber (k) matching becomes more important at higher wavenumbers, owing to the exponential dependence of the measured signal loss factor on wave vector mismatch. Wave vector matching allows for the Bragg scattering condition to be satisfied, which minimizes the signal loss at higher k’s. In the previous DBS system, without toroidal wave vector matching, the measured DBS signal-to-noise ratio at higher k θ (>8 cm –1 ) is substantially reduced, making it difficult to measure higher k θ turbulence. The new DBS system has been optimized to access higher wavenumber, k θ ≤ 20 cm –1 , density turbulence measurement. The optimization hardware addresses fluctuation wave vector matching using toroidal steering of the launch mirror to produce a backscattered signal with improved intensity. The probe’s sensitivity to high-k density fluctuations has been increased by approximately an order of magnitude compared to the old system that has been in use at DIII-D. Note that typical measurement locations are above or below the tokamak midplane on the low field side with normalized radial ranges of 0.5–1.0. As a result, the new DBS probe system with the toroidal matching of fluctuation wave vectors is thought to be critical to understanding high-k turbulent transport in fusion-relevant research at DIII-D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗