Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Introducing a novel technique for measuring hydrogen crossover in membrane-based electrochemical cells

Hydrogen crossover that is the unwanted hydrogen permeation across the membrane driven by the difference of gas concentrations causes a critical concern of safety and efficiency for electrochemical cells, such as fuel cells and electrolyzer cells. Although the hydrogen crossover measurement in fuel cells that employ platinum based catalysts is simple and widely used in laboratory settings, it is questionable to apply existing limiting current method to water electrolyzer cells and alkaline exchange membrane (AEM) systems, which is due to the typical catalyst materials used and membrane properties, respectively. In this work, we demonstrate the operation of a compact and low-cost method of measuring hydrogen crossover that works for both AEM and proton exchange membrane (PEM) systems. The method entails a tandem configuration that utilizes an upstream crossover cell with a downstream cell in hydrogen pump configuration to measure the crossover in the cell of interest. We have successfully measured the hydrogen crossover with different membranes at various differential pressures. The developed method can be applied to catalyst-free membranes (both PEM and AEM) as well as PGM free catalyst containing cells. It will be a promising technique for measuring hydrogen crossover in-situ for a real operating membraned-based electrochemical cell or stack.

08 HYDROGEN↗

Blower-door techniques for measuring interzonal leakage

Abstract The standard blower door test methods, such as ASTM E779, describe how to use a single blower door to determine the total leakage of a single-zone structure such as a detached single-family home. There are no standard test methods for measuring interzonal leakage in a two-zone or multi-zone building envelope such as might be encountered in with an attached garage or in a multifamily building. Some practitioners have been using techniques that involve making multiple measurements with a single blower door as well as combined measurements using multiple blower doors. Even for just two zones there are dozens of combinations of one-door and two-door test protocols that could conceivably be used to determine the interzonal air tightness. We examined many of these two-zone configurations using both simulation and measured data to estimate the accuracy and precision of each technique for realistic measurement scenarios. We also considered the impact of taking measurements at a single pressure versus over multiple pressures. We compared the various techniques and evaluated them for specific uses. Some techniques work better in one leakage regime; some are more sensitive to wind and other noise; some are more suited to determining only a subset of the leakage values. This paper makes recommendations on which techniques to use or not use for various cases and provides data that could be used to develop future test methods.

99 GENERAL AND MISCELLANEOUS↗

Assessment of Techniques for Measuring Tropospheric H Sub x O Sub Y: Summary

The objectives were: (1) to provide an assessment of the capability of the existing sensors of HxOy species at levels characteristic of the nonurban troposphere; (2) to identify those techniques adaptable to real-time measurement (sampled or continuous) onboard an aircraft platform; (3) to address the concern for intercalibration and intercomparison of techniques for measuring specific species; and (4) to recommend promising technologies for research and development for measuring important species for which a capability does not now exist or is presently of inadequate sensitivity.

Source record↗

A Comprehensive Methodology to Evaluate Losses and Process Variations in Silicon Solar Cell Manufacturing

Novel, high-throughput metrology methods are used in this paper for detailed performance loss analysis of approximately 400 industrial crystalline silicon solar cells, all coming from the same production line. The characterization sequence combines traditional global cell measurements (e.g., current-voltage, Suns-VOC) with camera-based cell imaging of voltage distribution and power dissipation from photoluminescence and lock-in thermography, respectively. Spatial variations in current collection are visualized using a high-speed external quantum efficiency and reflectance measurement technique. A nondestructive transfer length method (TLM) measurement technique is also implemented, featuring circular TLM structures hidden within the busbars of the cells. The variance of individual loss parameters and their impact on cell performance are quantified for this large group of cells. Based on correlations performed across parameters, recombination losses in the bulk and rear surface of the cell are shown to be the primary limiting factor for the cell efficiency. The nature of these distributions and correlations provide important insights about loss mechanisms in industrial solar cells, helping to prioritize efforts for optimizing the performance of the production line. Additionally, many of the parameters extracted from these techniques can be tied back to incoming material quality issues (e.g., poor bulk carrier lifetime, nonuniform wafer doping) and to individual unit processes (e.g., texturing, phosphorus diffusion, silicon nitride deposition, metallization), allowing the data to be used directly for process control in manufacturing. All of the datasets are made available for download.

14 SOLAR ENERGY↗

Atom-interferometric techniques for measuring uniform magnetic field gradients and gravitational acceleration

We discuss techniques for probing the effects of a constant force acting on cold atoms using two configurations of a grating echo-type atom interferometer. Laser-cooled samples of {sup 85}Rb with temperatures as low as 2.4 {mu}K have been achieved in a new experimental apparatus with a well-controlled magnetic environment. We demonstrate interferometer signal lifetimes approaching the transit time limit in this system ({approx}270 ms), which is comparable to the time scale achieved by Raman interferometers. Using these long time scales, we experimentally investigate the influence of a homogeneous magnetic field gradient using two- and three-pulse interferometers, which enable us to sense changes in externally applied magnetic field gradients as small as {approx}4x10{sup -5} G/cm. We also provide an improved theoretical description of signals generated by both interferometer configurations that accurately models experimental results. With this theory, absolute measurements of B gradients at the level of 3x10{sup -4} G/cm are achieved. Finally, we contrast the suitability of the two- and three-pulse interferometers for precision measurements of the gravitational acceleration, g.

74 ATOMIC AND MOLECULAR PHYSICS↗

Doppler techniques for measuring fluid velocities

Report gives detailed overview of current laser- and acoustic-Doppler techniques and is used as reference for application of technology to measurement of fluid velocities. Report provides background information, gives detailed summary of specific techniques with emphasis on advantages and disadvantages of each, error sources, and appropriateness of each method for particular applications.

Cliff, W. C.↗

Microwave resonance lamp absorption technique for measuring temperature and OH number density in combustion environments

A simple technique for simultaneous determination of temperature and OH number density is described, along with characteristic results obtained from measurements using a premixed, hydrogen air flat flame burner. The instrumentation is based upon absorption of resonant radiation from a flowing microwave discharge lamp, and is rugged, relatively inexpensive, and very simple to operate.

Lempert, Walter R.↗

Electroluminescence Imaging: A Quantitative Characterization Technique to Measure Dust Occlusion of Solar Cells

Electroluminescence (EL) imaging is a qualitative characterization technique that is typically used to identify cracks, corrosion, and other defects in solar cells. It consists of imaging a cell under forward bias, where the solar cell emits photons due to radiative electron-hole pair recombination. Over the past few years, our team has expanded this into a quantitative technique with the help of image processing. We have primarily used this method to investigate lunar dust occlusion of solar cells and arrays. Lunar dust accumulation on solar cells is a major concern because it directly limits light accessible to the cell, decreasing power output. Many teams are working to develop dust mitigation technology to protect these arrays on the surface of the Moon, but thoroughly characterizing their efficacy is important to ensure their success prior to launch. Here, we present EL as a quantitative characterization technique to observe dust coverage on solar cells that, when coupled with IV performance measurements, can offer unique insights into how dust coverage impacts power output. Quantitative electroluminescence imaging works by running EL images through an image processing script that first grayscales the image then plots a histogram of the brightness of each pixel. On its own, it does not offer much insight into a solar cell’s performance. However, when comparing images to a baseline pristine, undamaged, or uncoated solar cell, it can quickly provide information about the impacts of surface contaminants or damage to the cell. Here, we present a case study where quantitative EL is used to measure the efficacy of dust mitigation technology for flexible solar arrays and discuss the lessons learned about dust mitigation, testing with lunar simulant, and this characterization technique.

photovoltaics↗

SU-E-T-379: Evaluation of An EPID-Based System for Daily Dosimetry Check by Comparison with a Widely-Used Ionization Chamber-Based Device

Purpose: To examine the feasibility of using Varian’s EPID-based Machine Performance Check (MPC) system to track daily machine output through comparison with Sun Nuclear’s DailyQA3 (DQA) device. Methods: Daily machine outputs for two photon energies (6 and 16MV) and five electron energies (6, 9, 12, 16, 20MeV) were measured for one month using both MPC and DQA. Baselines measurements for MPC were taken at the start of the measurement series, while DQA baselines were set at an earlier date. In order to make absolute comparisons with MPC, all DQA readings were referenced to the average of the first three DQA readings in that series, minimizing systematic differences between the measurement techniques due to baseline differences. In addition to daily output measurements, weekly averages were also calculated and compared. Finally, the electron energy dependence of each measurement technique was examined by comparing energy-specific measurements to the average electron output of all energies each day. Results: For 6 and 16MV photons, the largest absolute percent differences between MPC and DQA were 0.60% and 0.73%, respectively. Weekly averages were within 0.17% and 0.23%, respectively. For all five electron energies, the greatest absolute percent differences between MPC and DQA for each energy ranged from 0.49%–0.83%. Weekly averages ranged from 0.07%–0.28%. DQA energy-specific electron readings matched the average electron output within 0.29% for all days and all energies. MPC energy-specific readings matched the average within 0.21% for 9–20MeV. However, 6MeV showed a larger distribution about the average with four days showing a difference greater than 0.30% and a maximum difference of 0.51%. Conclusion: MPC output measurements correlated well with the widely-used DQA3 for most beam energies, making it a reliable back up technique for daily output monitoring. However, MPC may display an energy dependence for lower electrons energies, requiring additional investigation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A technique for measurement of earth station antenna G/T by radio stars and Applications Technology Satellites.

A new technique has been developed to accurately measure the G/T of a small aperture antenna using geostationary satellites and the well established radio star method. A large aperture antenna having the capability of accurately measuring its G/T by using a radio star of known power density is used to obtain an accurate G/T to use as a reference. The CNR of both the large and small aperture antennas are then measured using an Applications Technology Satellite (ATS). After normalizing the two C/N ratios to the large antenna system noise temperature the G/T or the gain G of the small aperture antenna can then be determined.

Kochevar, H. J.↗

Surface roughness of flat and curved optical surfaces

Surface roughness measurement has several applications. Even a few A roughness will cause scattered light in optical systems. Smooth surfaces are required in a wide variety of instruments. For example, the outputs of the high power lasers are limited by the surface roughness of mirrors and windows. Similarly, the information storage capacity of magnetic media is limited by the roughness of the surface. Roughness reduces the resolving power of optics and distorts images. The performance of certain thin film components in electronic industries is affected by the roughness on the film surface. X-ray astronomical telescopes require smooth curved surfaces. To improve the surface quality, super sensitive detection methods are required. Wide ranging measurement techniques are developed based on interferometry, electron microscopy, C-rays, ellipsometry, light scattering, and using mechanical stylus, etc. Though there are several techniques available for measurement and evaluation of the surfaces, no single technique is fully adequate. Also, the technique used should be nondestructive and highly sensitive. So, an optical heterodyne profilometer was fabricated. Its current sensitivity is much better than 10A rms. It is a noncontact and nondestructive technique. The instrument can be operated even by unskilled personnel for routine measurements.

George, M. C.↗

Direct current magnetic Hall probe technique for measurement of field penetration in thin film superconductors for superconducting radio frequency resonators

Superconducting Radio Frequency (SRF) cavities used in particle accelerators are typically formed from or coated with superconducting materials. Currently, high purity niobium is the material of choice for SRF cavities that have been optimized to operate near their theoretical field limits. This brings about the need for significant R & D efforts to develop next generation superconducting materials that could outperform Nb and keep up with the demands of new accelerator facilities. To achieve high quality factors and accelerating gradients, the cavity material should be able to remain in the superconducting Meissner state under a high RF magnetic field without penetration of quantized magnetic vortices through the cavity wall. Therefore, the magnetic field at which vortices penetrate a superconductor is one of the key parameters of merit of SRF cavities. Techniques to measure the onset of magnetic field penetration on thin film samples need to be developed to mitigate the issues with the conventional magnetometry measurements that are strongly influenced by the film orientation and shape and edge effects. In this work, we report the development of an experimental setup to measure the field of full flux penetration through films and multi-layered superconductors. Our system combines a small superconducting solenoid that can generate a magnetic field of up to 500 mT at the sample surface and three Hall probes to detect the full flux penetration through the superconductor. We report this setup can be used to study alternative materials that could potentially outperform niobium, as well as superconductor–insulator–superconductor (SIS) multilayer coatings on niobium.

47 OTHER INSTRUMENTATION↗

Development of a dual phantom technique for measuring the fast neutron component of dose in boron neutron capture therapy

Purpose: Research and development of various accelerator-based irradiation systems for boron neutron capture therapy (BNCT) is underway throughout the world. Many of these systems are nearing or have started clinical trials. Before the start of treatment with BNCT, the relative biological effectiveness (RBE) for the fast neutrons (over 10 keV) incident to the irradiation field must be estimated. Measurements of RBE are typically performed by biological experiments with a phantom. Although the dose deposition due to secondary gamma rays is dominant, the relative contributions of thermal neutrons (below 0.5 eV) and fast neutrons are virtually equivalent under typical irradiation conditions in a water and/or acrylic phantom. Uniform contributions to the dose deposited from thermal and fast neutrons are based in part on relatively inaccurate dose information for fast neutrons. This study sought to improve the accuracy in the dose estimation for fast neutrons by using two phantoms made of different materials in which the dose components can be separated according to differences in the interaction cross sections. The development of a “dual phantom technique” for measuring the fast neutron component of dose is reported. Methods: One phantom was filled with pure water. The other phantom was filled with a water solution of lithium hydroxide (LiOH) capitalizing on the absorbing characteristics of lithium-6 (Li-6) for thermal neutrons. Monte Carlo simulations were used to determine the ideal mixing ratio of Li-6 in LiOH solution. Changes in the depth dose distributions for each respective dose component along the central beam axis were used to assess the LiOH concentration at the 0, 0.001, 0.01, 0.1, 1, and 10 wt. % levels. Simulations were also performed with the phantom filled with 10 wt. % {sup 6}LiOH solution for 95%-enriched Li-6. A phantom was constructed containing 10 wt. % {sup 6}LiOH solution based on the simulation results. Experimental characterization of the depth dose distributions of the neutron and gamma-ray components along the central axis was performed at Heavy Water Neutron Irradiation Facility installed at Kyoto University Reactor using activation foils and thermoluminescent dosimeters, respectively. Results: Simulation results demonstrated that the absorbing effect for thermal neutrons occurred when the LiOH concentration was over 1%. The most effective Li-6 concentration was determined to be enriched {sup 6}LiOH with a solubility approaching its upper limit. Experiments confirmed that the thermal neutron flux and secondary gamma-ray dose rate decreased substantially; however, the fast neutron flux and primary gamma-ray dose rate were hardly affected in the 10%-{sup 6}LiOH phantom. It was confirmed that the dose contribution of fast neutrons is improved from approximately 10% in the pure water phantom to approximately 50% in the 10%-{sup 6}LiOH phantom. Conclusions: The dual phantom technique using the combination of a pure water phantom and a 10%-{sup 6}LiOH phantom developed in this work provides an effective method for dose estimation of the fast neutron component in BNCT. Improvement in the accuracy achieved with the proposed technique results in improved RBE estimation for biological experiments and clinical practice.

60 APPLIED LIFE SCIENCES↗

An intercomparison technique for measuring thermal attachment cross sections and rate constants in distinct final channels

A new technique is introduced for comparing negative-ion signal rates in which a common ion is produced by dissociative attachment in a series of molecules. Measurements are carried out at electron energies less than 100 MeV and at resolutions of 6-8 MeV (FWHM). The technique is demonstrated by detection of the Cl(-) signal in CFCl3, CCl4, CF2Cl2, 1,1,2-C2Cl3F3, 1,1,1-C2Cl3F3 and C2Cl4. Measurements for 1,1,1-C2Cl3F3 show that there is a significant open channel, other than Cl(-) formation, which accounts for about 60 percent of negative-ion formation in thermal-multiple-collision (swarm) experiments. Channel cross sections and rate constants are given for the process Cl(-)/1,1,1-Cl2Cl3F3, as well as in C2Cl4, for the separate channels Cl(-)/C2Cl4 and C2Cl4(-)/C2Cl4.

Alajajian, S. H.↗

Optimization of the tungsten oxide technique for measurement of atmospheric ammonia

Hollow tubes coated with tungstic acid have been shown to be of value in the determination of ammonia and nitric acid in ambient air. Practical application of this technique was demonstrated utilizing an automated sampling system for in-flight collection and analysis of atmospheric samples. Due to time constraints these previous measurements were performed on tubes that had not been well characterized in the laboratory. As a result the experimental precision could not be accurately estimated. Since the technique was being compared to other techniques for measuring these compounds, it became necessary to perform laboratory tests which would establish the reliability of the technique. This report is a summary of these laboratory experiments as they are applied to the determination of ambient ammonia concentration.

Brown, Kenneth G.↗

Apparatus description and data analysis of a radiometric technique for measurements of spectral and total normal emittance

The development of a radiometric technique for determining the spectral and total normal emittance of materials heated to temperatures of 800, 1100, and 1300 K by direct comparison with National Bureau of Standards (NBS) reference specimens is discussed. Emittances are measured over the spectral range of 1 to 15 microns and are statistically compared with NBS reference specimens. Results are included for NBS reference specimens, Rene 41, alundum, zirconia, AISI type 321 stainless steel, nickel 201, and a space-shuttle reusable surface insulation.

Edwards, S. F.↗