Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mechanical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Efficient loading of reduced data ensembles produced at ORNL SNS/HFIR neutron time-of-flight facilities

We present algorithmic improvements to the loading operations of certain reduced data ensembles produced from neutron scattering experiments at Oak Ridge National Laboratory (ORNL) facilities. Ensembles from multiple measurements are required to cover a wide range of the phase space of a sample material of interest. They are stored using the standard NeXus schema on individual HDF5 files. This makes it a scalability challenge, as the number of experiments stored increases in a single ensemble file. The present work follows up on our previous efforts on data management algorithms, to address identified input output (I/O) bottlenecks in Mantid, an open-source data analysis framework used across several neutron science facilities around the world. We reuse an in-memory binary-tree metadata index that resembles data access patterns, to provide a scalable search and extraction mechanism. In addition, several memory operations are refactored and optimized for the current common use cases, ranging most frequently from 10 to 180, and up to 360 separate measurement configurations. Results from this work show consistent speed ups in wall-clock time on the Mantid LoadMD routine, ranging from 19% to 23% on average, on ORNL production computing systems. The latter depends on the complexity of the targeted instrument-specific data and the system I/O and compute variability for the shared computational resources available to users of ORNL’s Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR) instruments. Nevertheless, we continue to highlight the need for more research to address reduction challenges as experimental data volumes, user time and processing costs increase.

Godoy, William↗

Pretest Modeling A Spent Nuclear Fuel Seismic Shake Test

The U.S. Department of Energy Spent Fuel and Waste Science and Technology (SFWST) program is planning to conduct a series of full-scale shake table tests to simulate hypothetical earthquake conditions and record the response of surrogate spent nuclear fuel (SNF) assemblies in a dry canister storage system mockup. The shake table motions will represent a range of hypothetical earthquake conditions at hypothetical locations in the continental U.S. to generally define the range of mechanical loads that SNF can be expected to experience during extended dry storage periods. This paper describes the pretest predictions made with LS-DYNA models of the mockup storage systems. The test will use two dry storage system configurations, a mockup vertical concrete cask (VCC) and a mockup horizontal storage module (HSM). The test will use a production-quality canister and basket. Within the canister will be four instrumented fuel assemblies with fuel rods containing surrogate mass and 28 instrumented dummy assemblies that are intended to match the mass and outer dimension of a fuel assembly. The finite element models include models of the VCC and HSM on the shake table to calculate the system level dynamic responses and separate single fuel assembly models to calculate stress and strain in fuel assembly components. Both types of models include nonlinear behavior like rod-to-rod contact and the ability for VCC’s to rock and slide. This paper presents the expected response of the VCC, HSM, and fuel assemblies to the shake table testing that is planned to start in April of 2024. The earthquake conditions represent seismic hazards in the 2,000-to-20,000-year return period range. The test data is expected to confirm the expectation that fuel rod cladding will remain intact, fuel assembly structural components like guide tubes will remain intact, and no significant VCC sliding or tipping will occur in the range of conditions to be tested with the shake table.

Klymyshyn, Nicholas A.↗

Monte Carlo calculations of the extraction of scintillation light from cryogenic $N$-type GaAs

We report the high scintillation luminosity of n-type GaAs at 10 °K is surprising because (1) with a refractive index of 3.5, escape is inhibited by total internal reflection and (2) narrow-beam experiments at 90 °K report infrared absorption coefficients of several per cm. This paper presents Monte Carlo calculations showing that the high luminosity at 10 °K can be explained if (1) the narrow-beam absorption is almost all optical scattering and (2) the absolute absorption coefficient is below 0.1 per cm. Sixteen surface reflector configurations are simulated for a range of internal scattering and absolute absorption coefficients, and these can guide the design of cryogenic scintillating GaAs targets for the direct detection of dark matter. The discussion section presents a possible infrared scattering mechanism based on the metallic nature of n-type GaAs. A supplement file describes (1) the Monte Carlo program steps in detail and (2) how narrow-beam and integrating sphere experiments can measure the cryogenic optical scattering and absolute absorption coefficients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photoelectron spectroscopy with entangled photons; enhanced spectrotemporal resolution

In this theoretical study, we show how photoelectron signals generated by time-energy entangled photon pairs can monitor ultrafast excited state dynamics of molecules with high joint spectral and temporal resolutions, not limited by the Fourier uncertainty of classical light. This technique scales linearly, rather than quadratically, with the pump intensity, allowing the study of fragile biological samples with low photon fluxes. Since the spectral resolution is achieved by electron detection and the temporal resolution by a variable phase delay, this technique does not require scanning the pump frequency and the entanglement times, which significantly simplifies the experimental setup, making it feasible with current instrumentation. Application is made to the photodissociation dynamics of pyrrole calculated by exact nonadiabatic wave packet simulations in a reduced two nuclear coordinate space. This study demonstrates the unique advantages of ultrafast quantum light spectroscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In Situ High Energy X-ray Diffraction Characterization of Phase Transformations and Mechanical Behaviors in Rapidly Solidified Titanium and Stainless Steel Alloys [Thesis]

Advanced manufacturing techniques like additive manufacturing (AM) have poised themselves to revolutionize metal manufacturing. A wide range of AM techniques are capable of manufacturing metal components with unique, complex geometries and hastening the scientific-engineering-development cycle. Metal AM relies on a layer-by-layer rapid manufacturing process to build components from the substrate up. Rapid solidification is a large departure from traditional metal manufacturing due to its complex physics. Characterization of rapid solidification is difficult, stemming from the small volumes used in AM and the fast dynamics of the process. High energy X-ray diffraction (HEXRD) is a solution to the characterization problems of rapidly solidified alloys and AM. HEXRD can probe small volumes at fast rates and provides a wide range of thermomechanical and kinetic information. This thesis presents the application of HEXRD to rapidly solidified titanium and stainless steel alloys through a series of case studies. In the first two studies, HEXRD is applied to rapidly solidified titanium and stainless steel welds. The materials are characterized for their temperature history, phase changes, kinetics, and microstructural evolution. In the next case study, HEXRD is applied to characterize phase changes in elastocaloric NiTi shape memory alloys (SMAs) under thermomechanical load. HEXRD, in conjunction with other tools, is used to explain the superior performance of the additively manufactured SMAs. In the final two case studies, HEXRD is used to measure the mechanical response of AM parts with complex geometries; namely, the octet truss lattice. Diffraction reveals a wide range of materials information about the AM microstructure including unexpected phases, texture, and mechanical response to loading. The mechanical results from HEXRD and then compared with theoretical predictions about the performance of octet truss lattices. Summarily, HEXRD is a diverse tool that is poised to address the complex characterization problems of many aspects of the additive manufacturing process.

36 MATERIALS SCIENCE↗

Defect Characterization of Monocrystalline Silicon Solar Cells with Polysilicon Passivated Contact Using Electrically-Detected Magnetic Resonance (EDMR) Spectroscopy

As the c-Si based solar cell efficiencies are approaching over 26%, it is becoming critical to characterize the low concentrations of the defects – as low as 10^10-10^11 cm-3 (for e.g., iron contamination in high-lifetime Ga-doped wafers3 and n-type wafers), and further reduce them. Also, atomistic level understanding of the mechanisms of the low concentration process-induced-defects and reliability limiting defects (such as light and elevated temperature induced degradation, surface passivation degradation) is needed to design the mitigation strategies. The conventional characterization techniques are limited due to their detection limitations. Some of the techniques based on lifetime spectroscopies can still be used for low concentration characterization however, they are based on estimations and theoretical models and hence, indirect and cannot fully reveal information about the microscopic mechanism of the defects. Thus, we present the application of an ultrasensitive magnetic resonance-based technique for the direct spectroscopic detection of the defects in Si PV - electrically detected magnetic resonance (EDMR). In this work, we aim to focus on establishing a process flow for fabrication of minicells with (miniature replica of the larger-area cells) and setting up the routine for EDMR measurements on them with the EDMR instrumentation capability at NREL. For the EDMR measurements, sample size is limited by the dimensions of sample holder tube (width less than 3.2 mm, active area - 20 mm). Thus, we have designed c-Si based minicells with polysilicon (poly-Si) passivated contacts same as the larger-area cells that we fabricate in our group at NREL. We also modified our minicell process flow for fabricating the textured minicells for preserving the texture during processing and taking care of the laser-ablation edge damage which can significantly affect the performance of such small devices. We have achieved comparable performance on these newly fabricated minicells as that of our 4 cm2 devices with same structure (comparable VOC, JSC, FF). We also conducted EDMR measurements on the minicells and observed a distinct EDMR signal at g-value ~2.005 at temperatures 30K and above, as shown in Fig. 2. We associate this signal to the presence of silicon dangling bonds based on the g-value. We also observed an EDMR signal at g-value ~1.998 at temperature ~5K. The origin of this signal is still being investigated. Thus, we show the proof of concept of minicells and EDMR measurements with which we now aim to study some of the unknown defects in silicon solar cell devices.

EDMR↗

Flow Sensor Test Article (F-STAr) (Design and Fabrication Status Report)

The Flow Sensor Test Article (F-STAr) is a test article currently under construction for the Mechanisms Engineering Test Loop (METL). F-STAr was designed to provide high sodium flowrate capabilities for sensor calibration, component testing, and fluid studies. Figure 1 shows two solid model views of the new test article. F-STAr includes a high-capacity pump that can provide a nominal flowrate of 120 GPM; a test section support structure that can accommodate a wide array of sub-test articles and their instrumentation; and finally, a heating and cooling system to aid in controlling the testing environment. Initially, F-STAr will be configured to test liquid metal flow sensors, specifically field shift sensors like the Eddy Current Flow Sensors (ECFS) based on the RDT C4-7T standard. To test these sensors, two test sections were designed that attempt to model Sodium Fast Reactor (SFR) outlet conditions. Figure 2 shows models of the “Full-Scaled Test Section” (FSTS) that represents a generic SFR fuel handling socket and a “Pseudo-Scaled Test Section” (PSTS) that represents a generic array of scaled fuel handling sockets. While F-STAr will be configured to test ECFS’s, it can also be outfitted to meet other experimental needs. For example, F-STAr could be setup with a test section that includes a fluidic diode or a component test investigating the performance of hydrodynamic bearings. Other test sections include studies of sodium thermal hydraulics like thermal striping. Overall, F-STAr is a flexible test article designed to accommodate many needs. This report will provide a status update on the design and construction of F-STAr. Manufacturing of all components has commenced, and several components have already been completed. These components include the pump and test section assembly stand. Other components, such as the heater, have been completed but were rejected due to the vendor not meeting the requirements of the purchase order. Lastly, the submersible flowmeter and main flange components are under construction, and their status will be reviewed in this report. Overall, most of the F-STAr components and parts will be completed by the end of September 2022.

42 ENGINEERING↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Tunneling Spectroscopy at Megabar Pressures: Determination of the Superconducting Gap in Sulfur

The recent discovery of high-temperature, high-pressure superconductors, such as hydrides and nickelates, has opened exciting avenues in studying high-temperature superconductivity. The primary superconducting properties of these materials are well characterized by measuring various electrical and magnetic properties, despite the challenges posed by the high-pressure environment. Experimental microscopic insight into the pairing mechanism of these superconductors is even more challenging, due to the lack of direct probes of the superconducting gap structures at high pressure conditions. Here, we have developed a planar tunnel junction technique for diamond anvil cells and present ground-breaking tunneling spectroscopy measurements at megabar pressures. We determined the superconducting gap of elemental sulfur at 160 GPa, a key constituent of the high-temperature superconductor H 3 S . High quality tunneling spectra indicate that β -Po phase sulfur is a type II superconductor with a single s -wave gap with a gap value 2 Δ ( 0 ) = 5.6 meV . This technique is compatible with superconducting compounds synthesized in diamond anvil cells and provides insight into the pairing mechanism in novel superconductors under high-pressure conditions. Published by the American Physical Society 2024

36 MATERIALS SCIENCE↗

Imaging Nanoscale Energy Transport and Conversion with Ultrafast Electron Microscopy (Final Technical Report)

Light-matter interactions are ubiquitous in nature and reside at the heart of innumerable technologies. The cascade of processes that occur when a material absorbs a photon of light are exceedingly complex and are interwoven in both space and time, rendering precise determination of the atomic-scale and ultrafast mechanisms immensely challenging. The advent of methods for generating short pulses of light several decades ago led to major advances in understanding the initial moments of light absorption and the resultant effects, though directly interrogating the response of the atoms within the material continued to prove challenging. More recently, methods for generating ultrashort pulses of X-rays and fast electrons have opened the way to probing photoinduced structural dynamics of a wide range of matter in multiple phases. An especially promising laboratory-scale method is ultrafast electron microscopy (UEM), wherein the modalities of conventional transmission electron microscopes (imaging, diffraction, spectroscopy) are extended into the femtosecond temporal regime. Here, the ultrafast imaging and diffraction modalities of UEM were used to study the transient structural aspects of photoexcitation of semiconducting materials (e.g., spatially-resolved electron-phonon coupling, excitation and emission of acoustic phonons, and discrete nanoscale scattering processes). The project had three main objectives: (1) determination of the excitation mechanisms of dense, hypersonic charge-carrier waves and the spatially mediated means by which they couple to the lattice via coherent phonon emission, especially with UEM imaging, wherein effects of nanoscale structural and morphological features on the coupling and relaxation dynamics are expected to dictate nucleation sites and preferred wave vectors, (2) elucidation of photoinduced acoustic-phonon seeding, emergence, propagation, and decay over nanoscale crystal regions and especially with respect to local strain fields and atomic-scale disruptions in lattice order, and (3) interwoven with the first two were efforts aimed at realizing combined angstrom-femtosecond spatiotemporal imaging with UEM. The outcomes and impacts of this project were the generation of new knowledge with respect to fundamental light-matter interactions and, especially, the spatially-mediated excitation and evolution of the structural response of materials following coherent photoexcitation. Importantly, the spatial and temporal resolutions of the UEM imaging modalities used are well-suited for such studies and enable spatially-resolved mechanisms to be determined as a function of atomic order, structural features, and morphology. In addition, ultrafast crystallographic measurements were used to correlate real- and reciprocal-space dynamics in order to determine atomic-scale preferential wave vectors and ultrafast scattering mechanisms, especially as dictated by specimen boundary conditions. The obtained results, as detailed in peer-reviewed publications and presentations, illustrate the importance of ultrafast, angstrom-scale real-space imaging for developing a comprehensive understanding of energy transport and conversion in materials.

47 OTHER INSTRUMENTATION↗

Printed Strain Gauges for High Temperature Applications (>300°C)

The real-time understanding of strain and deformation of materials provides prognostic health monitoring of components of current operational reactors and valuable data that shortens the timeline for the development of new nuclear-relevant materials in test reactor experiments. This report discusses the current development and testing of additively manufactured strain gauges. This has potential to improve the sensor design and manufacturing techniques to meet the requirements of the current and advanced nuclear reactors (i.e., in terms of environment conditions, sample geometry, and materials compatibility). The developmental additively manufactured strain gauges are exposed to separate effects testing (i.e., mechanical strain, high temperature) to determine environmental factors that affect the strain gauge. In addition, sensor qualification methodologies are further developed for determining the reliability and robustness at the interface of the AM strain gauge materials.

36 MATERIALS SCIENCE↗

A Perspective into Operando Methods for Probing Catalytic Interfaces

Rational design of electrocatalysts for (photo)electrochemical (PEC) processes like hydrogen and oxygen evolution and CO2 reduction reactions is aided by the recent improvements in capabilities of operando measurements, where morphology, composition, and/or function are probed during active catalysis. Through operando microscopy and spectroscopy, structure, catalytic microenvironment, oxidation state, adsorbates, and products can be measured to gain a better understanding of catalyst behavior and suggest possible improvements. Visualizing evolving catalyst morphologies, surface compositions, and electrochemical behavior also helps address many fundamental research questions for a better understanding of catalytic mechanisms. Correlating morphology with chemical identity or functional behavior using a variety of innovative microscopy methods is particularly promising for guiding development of next generation catalysts, and there are also many recent examples of using AI and robotics tools to innovate and speed development. In this Perspective, advances made over the past few years in operando imaging of catalysts relevant to solar fuels will be explored, followed by an outlook on technological developments in instrumentation, sample design, and computational power that may be applied to this field.

Catalysts↗

Tailoring Negative Thermal Expansion via Tunable Induced Strain in La–Fe–Si-Based Multifunctional Material

Zero thermal expansion (ZTE) composites are typically designed by combining positive (PTE) with negative thermal expansion (NTE) materials acting as compensators and have many diverse applications, including in high-precision instrumentation and biomedical devices. La(Fe 1-x ,Si x )13-based compounds display several remarkable properties, such as giant magnetocaloric effect and very large NTE at room-temperature. Both are linked via strong magnetovolume coupling, which leads to sharp magnetic and volume changes occurring simultaneously across first-order phase transitions; the abrupt nature of these changes makes them unsuitable as thermal expansion compensators. To make these materials more useful practically, the mechanisms controlling the temperature over which this transition occurs and the magnitude of contraction need to be controlled. In this work, ball-milling was used to decrease particles and crystallite sizes and increase the strain in LaFe 11.9 Mn 0.27 Si 1.29 H x alloys. Such size and strain tuning effectively broadened the temperature over which this transition occurs. The material’s NTE operational temperature window was expanded, and its peak was suppressed by up to 85%. This work demonstrates that induced strain is the key mechanism controlling these materials’ phase transitions. This allows the optimization of their thermal expansion towards room-temperature ZTE-applications.

36 MATERIALS SCIENCE↗

Nuclear reactor radiation and temperature effects on piezoelectric surface acoustic wave devices

Surface acoustic wave (SAW) resonators were characterized in-situ in a nuclear reactor environment at high temperature. Devices based on lithium niobate (LiNbO 3 ), aluminum nitride (sc-AlN), and thin-film aluminum nitride on sapphire substrate (AlN/sapphire) were tested up to 400 °C temperature and 1.9 × 10 12 n/cm 2 s neutron flux. Shifts in device resonant frequency were detected in response to temperature and neutron flux. Devices undergo a frequency change when exposed to neutron flux. At 300 °C, AlN/sapphire produced the strongest neutron flux response about 1.02 ppm at 1.27 × 10 12 n/cm 2 s neutron flux (5.7 × 10 4 rad-Si/hr neutron dose rate), compared to 0.30 ppm for LiNbO 3 and 0.17 ppm for sc-AlN. While the transient kinetics in response to step change in neutron flux support the defect-accumulation mechanism, the concurrent measurement of device temperature using resistive temperature sensor suggests additional heating caused by absorption of gamma rays can also play a role. These results make SAW devices attractive candidates for sensor applications in extreme environments.

Aluminum nitride↗

A sensitive and robust thin-film x-ray detector using 2D layered perovskite diodes

Solid-state radiation detectors, using crystalline semiconductors to convert radiation photons to electrical charges, outperform other technologies with high detectivity and sensitivity. Here, we demonstrate a thin-film x-ray detector comprised with highly crystalline two-dimensional Ruddlesden-Popper phase layered perovskites fabricated in a fully depleted p-i-n architecture. It shows high diode resistivity of 10 12 ohm·cm in reverse-bias regime leading to a high x-ray detecting sensitivity up to 0.276 C Gy air –1 cm –3 . Such high signal is collected by the built-in potential underpinning operation of primary photocurrent device with robust operation. The detectors generate substantial x-ray photon–induced open-circuit voltages that offer an alternative detecting mechanism. Furthermore, our findings suggest a new generation of x-ray detectors based on low-cost layered perovskite thin films for future x-ray imaging technologies.

47 OTHER INSTRUMENTATION↗

Irradiation Behavior of Piezoelectric Materials for Nuclear Reactor Sensors

In-situ measurement of surface acoustic wave (SAW) resonators were used to characterize piezoelectric materials behavior in a nuclear reactor environment. Lithium niobate and aluminum nitride devices were tested up to 500°C temperature and 450 kW reactor power (1.9x10 12 n/cm 2 s). The resonant frequency responds to step changes in temperature and power. Materials’ response are inferred from the observed resonant frequency changes, in particular the kinetic behavior is used to determine mechanisms responsible for observed changes. The observed response is attributed to two mechanisms: temperature increase from gamma heating and accumulation of radiation-induced defects. Both of these mechanisms alter the physical properties of the piezoelectric materials, particularly the elastic constants. The demonstrated repeatability and reliability of SAW devices are attractive for sensor applications in extreme environments.

36 MATERIALS SCIENCE↗

Role of chemical production and depositional losses on formaldehyde in the Community Regional Atmospheric Chemistry Multiphase Mechanism (CRACMM)

Abstract. Formaldehyde (HCHO) is an important air pollutant with direct cancer risk and ozone-forming potential. HCHO sources are complex because HCHO is both directly emitted and produced from oxidation of most gas-phase reactive organic carbon. We update the secondary production of HCHO in the Community Regional Atmospheric Chemistry Multiphase Mechanism (CRACMM) in the Community Multiscale Air Quality (CMAQ) model. Production of HCHO from isoprene and monoterpenes is increased, correcting an underestimate in the current version. Simulated June–August surface HCHO during peak photochemical production (11:00–15:00 LT, local time) increased by 0.6 ppb (32 %) over the southeastern USA and by 0.2 ppb (13 %) over the contiguous USA. The increased HCHO compares more favorably with satellite-based observations from the TROPOspheric Monitoring Instrument (TROPOMI) and from aircraft-based observations. Evaluation against hourly surface observations indicates a missing nighttime sink that can be improved by increased nighttime deposition, which reduces June–August nocturnal (20:00–04:00 LT) surface HCHO by 1.1 ppb (36 %) over the southeastern USA and 0.5 ppb (29 %) over the contiguous USA. The ability of CRACMM to capture peak levels of HCHO at midday is improved, particularly at sites in the northeastern USA, while peak levels at sites in the southeastern USA are improved, although still lower than observed. Using established risk assessment methods, lifetime exposure of the population in the contiguous USA (∼ 320 million) to ambient HCHO levels predicted here may result in 6200 lifetime cancer cases, with 40 % from controllable anthropogenic emissions of nitrogen oxides and reactive organic compounds. Chemistry updates will be available in CRACMM version 2 (CRACMM2) in CMAQv5.5.

Skipper, T. Nash↗

Measurement of engine-oil fuel dilution using laser induced florescence spectroscopy

An optical diagnostic, based on laser-induced fluorescence (LIF), has been developed for on-engine measurements of real-time fuel dilution of engine oil, or fuel in oil (FiO). Fuel dilution of oil is believed to be one of the underlying mechanisms that promotes low speed pre-ignition (LSPI) during high-load engine operations. While standard (e.g., ASTM D3524-90) methods are not capable of transient measurements, the LIF technique resolves transient dilution on the minutes time scale, making it possible to study the relation between FiO and LSPI. The measurement is based on adding a dye (ca. 500 ppm) to the fuel and monitoring for its presence in the oil via LIF. The instrument contains a 532-nm laser diode, and a spectrometer to resolve the LIF spectra. A fiber-optic assembly links the instrument to the engine measurement location; the probe is in a Y-configuration with the six fibers around one on a common probe end that connects to the engine; the Y-assembly legs are connected to the instrument; the two legs are the six fibers for transporting the laser light, and the single fiber for the fluorescence. We have expanded on our previous work (Parks et al, SAE paper 2007-01-4108, 2007), by demonstrating the diagnostic technique with to measure transient oil dilution on a 2.0-liter GM ECOTEC LNF single cylinder SI engine. The proposed LIF diagnostic will be critical in studying oil-dilution correlation with LSPI events.

Neupane, Sneha↗