Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microchannels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Improved Bacterial and Viral Recoveries from 'Complex' Samples using Electrophoretically Assisted Acoustic Focusing

Automated front-end sample preparation technologies can significantly enhance the sensitivity and reliability of biodetection assays [1]. We are developing advanced sample preparation technologies for biowarfare detection and medical point-of-care diagnostics using microfluidic systems with continuous sample processing capabilities. Here we report an electrophoretically assisted acoustic focusing technique to rapidly extract and enrich viral and bacterial loads from 'complex samples', applied in this case to human nasopharyngeal samples as well as simplified surrogates. The acoustic forces capture and remove large particles (> 2 {micro}m) such as host cells, debris, dust, and pollen from the sample. We simultaneously apply an electric field transverse to the flow direction to transport small ({le} 2 {micro}m), negatively-charged analytes into a separate purified recovery fluid using a modified H-filter configuration [Micronics US Patent 5,716,852]. Hunter and O'Brien combined transverse electrophoresis and acoustic focusing to measure the surface charge on large particles, [2] but to our knowledge, our work is the first demonstration combining these two techniques in a continuous flow device. Marina et al. demonstrated superimposed dielectrophoresis (DEP) and acoustic focusing for enhanced separations [3], but these devices have limited throughput due to the rapid decay of DEP forces. Both acoustic standing waves and electric fields exert significant forces over the entire fluid volume in microchannels, thus allowing channels with larger dimensions (> 100 {micro}m) and high throughputs (10-100 {micro}L/min) necessary to process real-world volumes (1 mL). Previous work demonstrated acoustic focusing of microbeads [4] and biological species [5] in various geometries. We experimentally characterized our device by determining the biological size-cutoff where acoustic radiation pressure forces no longer transport biological particles. Figure 1 shows images of E.Coli ({approx}1 {micro}m) and yeast ({approx}4-5 {micro}m) flowing in a microchannel (200 {micro}m deep, 500 {micro}m wide) at a flow rate of 10 {micro}L/min. The E.Coli does not focus in the acoustic field while the yeast focuses at the channel centerline. This result suggests the acoustic size-cutoff for biological particles in our device lies between 2 and 3 {micro}m. Transverse electrophoresis has been explored extensively in electric field flow fractionation [6] and isoelectric focusing devices [7]. We demonstrated transverse electrophoretic transport of a wide variety of negatively-charged species, including fluorophores, beads, viruses, E.Coli, and yeast. Figure 2 shows the electromigration of a fluorescently labeled RNA virus (MS2) from the lower half of the channel to the upper half region with continuous flow. We demonstrated the effectiveness of our electrophoretically assisted acoustic focusing device by separating virus-like particles (40 nm fluorescent beads, selected to aid in visualization) from a high background concentration of yeast contaminants (see Figure 3). Our device allows for the efficient recovery of virus into a pre-selected purified buffer while background contaminants are acoustically captured and removed. We also tested the device using clinical nasopharyngeal samples, both washes and lavages, and demonstrated removal of unknown particulates (>2 ?m size) from the sample. Our future research direction includes spiking known amounts of bacteria and viruses into clinical samples and performing quantitative off-chip analysis (real-time PCR and flow cytometry).

42 ENGINEERING↗

Method for dialysis on microchips using thin porous polymer membrane

Laser-induced phase-separation polymerization of a porous acrylate polymer is used for in-situ fabrication of dialysis membranes inside glass microchannels. A shaped 355 nm laser beam is used to produce a porous polymer membrane with a thickness of about 15 .mu.m, which bonds to the glass microchannel and forms a semi-permeable membrane. Differential permeation through a membrane formed with pentaerythritol triacrylate was observed and quantified by comparing the response of the membrane to fluorescein and fluorescently tagging 200 nm latex microspheres. Differential permeation was observed and quantified by comparing the response to rhodamine 560 and lactalbumin protein in a membrane formed with SPE-methylene bisacrylamide. The porous membranes illustrate the capability for the present technique to integrate sample cleanup into chip-based analysis systems.

36 MATERIALS SCIENCE↗

Dialysis membrane for separation on microchips

Laser-induced phase-separation polymerization of a porous acrylate polymer is used for in-situ fabrication of dialysis membranes inside glass microchannels. A shaped 355 nm laser beam is used to produce a porous polymer membrane with a thickness of about 15 .mu.m, which bonds to the glass microchannel and forms a semi-permeable membrane. Differential permeation through a membrane formed with pentaerythritol triacrylate was observed and quantified by comparing the response of the membrane to fluorescein and fluorescently tagging 200 nm latex microspheres. Differential permeation was observed and quantified by comparing the response to rhodamine 560 and lactalbumin protein in a membrane formed with SPE-methylene bisacrylamide. The porous membranes illustrate the capability for the present technique to integrate sample cleanup into chip-based analysis systems.

36 MATERIALS SCIENCE↗

Characteristics of fast timing MCP-PMTs in magnetic fields

Here, the motivation of this paper is to explore the parameters that affect the performance of Microchannel Plate Photomultiplier Tubes (MCP-PMTs) in magnetic fields with the goal to guide their design to achieve a high magnetic field tolerance. MCP-PMTs based on two different designs were tested. The magnetic field tolerance of MCP-PMT based on a design providing independently biased voltages showed a significant improvement (up to 0.7 T) compared to the one utilizing an internal resistor chain design (up to 0.1 T), indicating the importance of individually adjustable voltages. The effects of the rotation angle of the MCP-PMT relative to the magnetic field direction and of the bias voltage between the photocathode and the top MCP were extensively investigated using the MCP-PMT based on the independently biased voltage design. It was found that the signal amplitude of the MCP-PMT exhibits an enhanced performance at a tilt angle of ±8°, due to the 8°bias angle of the MCP pores. Fianlly, the maximum signal amplitude was observed at different bias voltages depending on the magnetic field strength.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design complexity and performance analysis in additively manufactured heat exchangers

The main objective of this research is to investigate the tradeoffs between design complexity and thermal performance in additively manufactured metallic heat exchangers. Such heat exchangers have become a favorite topic for investigation in various fields ranging from air conditioning to aircraft gas turbine engines. In particular, high manufacturing cost has emerged as the major drawback in broad applications of manifold-microchannel heat exchanger (MMHXs). The possibility of cost-effective manufacturing has generated wide interest in applying additive manufacturing (AM) for fabricating MMHXs. Furthermore, AM technologies will provide an opportunity for enhanced design and superior heat transfer performance. In this study, innovative MMHXs are designed and fabricated through selective laser melting. An experimental setup was designed to measure pressure drop and heat transfer for the developed MMHXs with a wide range of Reynolds numbers. Furthermore, the coefficient of performance was calculated based on the heat flow rate, air pressure drop, and air flow rate. Measurement results demonstrated that in some scenarios adding more internal features, i.e., increasing design complexity, does not necessarily improve the MMHX performance.

10 SYNTHETIC FUELS↗

Capacitively coupled pickup in MCP-based photodetectors using a conductive metallic anode

We have designed and tested a robust 20×20 cm 2 thin metal film internal anode capacitively coupled to an external array of signal pads or micro-strips for use in fast microchannel plate photodetectors. The internal anode, in this case a 10 nm-thick NiCr film deposited on a 96% pure Al 2 O 3 3 mm-thick ceramic plate and connected to HV ground, provides the return path for the electron cascade charge. The multi-channel pickup array consists of a printed-circuit card or glass plate with metal signal pickups on one side and the signal ground plane on the other. The pickup can be put in close proximity to the bottom outer surface of the sealed photodetector, with no electrical connections through the photodetector hermetic vacuum package other than a single ground connection to the internal anode. Two pickup patterns were tested using a small commercial MCP-PMT as the signal source: 1) parallel 50 Ω 25-cm-long micro-strips with an analog bandwidth of 1.5 GHz, and 2) a 20×20 cm 2 array of 2-dimensional square ‘pads’ with sides of 1.27 cm or 2.54 cm. The rise-time of the fast input pulse is maintained for both pickup patterns. For the pad pattern, we observe 80% of the directly coupled amplitude. For the strip pattern we measure 34% of the directly coupled amplitude on the central strip of a broadened signal. The physical decoupling of the photodetector from the pickup pattern allows easy customization for different applications while maintaining high analog bandwidth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large Area Picosecond Photodetector (LAPPD TM ) - Pilot production and development status

Here, we discuss performance results achieved for fully functional sealed Large Area Picosecond Photodetectors (LAPPD (TM)) in tests performed at Incom Inc., as well as independent test results reported by our early adopters. The LAPPD is a microchannel plate (MCP) based large area picosecond photodetector, capable of imaging with single-photon sensitivity at high spatial and temporal resolutions in a hermetic package. The LAPPD has an active area of 350 square centimeters in an all-glass hermetic package with a fused silica window and bottom plate and sidewalls made of borosilicate float glass. Signals are generated by a bi-alkali Na 2 KSb photocathode and amplified with a stacked chevron pair of MCPs produced by applying resistive and emissive atomic layer deposition coatings to glass capillary array (GCA) substrates. Signals are collected on RF stripline anodes applied to the bottom plates which exit the detector via pin-free hermetic seals under the side walls. LAPPD test and performance results for product produced and delivered to early adopter customers during the first half of 2018 are reviewed. These results include electron gains ≥ 7.5 x 10 6 @ 850/950 V (entry/exit MCP), low dark noise rates (22 Cts/s/cm 2 ), single photoelectron (PE) timing resolution of 64 picoseconds RMS, and single photoelectron spatial resolution along and across strips of 2.8 mm and 1.3 mm RMS respectively. Many of these devices also had very high QE photocathodes that were uniform over the full 195 mm x 195 mm window active area (LAPPD #15 QE% @ 365 nm Max/Avg/Min = 25.8/22.3 ± 3/15.7). An update is additionally provided of developments that enable capacitive signal coupling from the detector to application specific pads or stripline readout patterns deployed on printed circuit boards positioned beneath the file, outside of the vacuum package. We conclude with examples of how sensors offering picosecond timing, in diverse applications can bring transformative change to detector technology and applications in future experiments.

47 OTHER INSTRUMENTATION↗

First experimental demonstration of time-resolved X-ray measurements with next-generation fast-timing MCP-PMT

We report the first successful time-resolved X-ray measurements at the APS 10-ID-B beamline by coupling ultrafast scintillators with photodetectors. Multiple scintillator and sensor pairs (LYSO, plastic scintillator, dynode PMTs, MCP-PMT), as well as a standalone detector (diamond), were tested to demonstrate the time-resolved measurements using hard X-rays at energies of 20 keV and above. The experimental results show that a number of choices exist for time-resolved high-energy X-ray beam measurement. Notably, by gating the photocathode, the Argonne fabricated fast-timing microchannel plate photomultiplier and LYSO crystal pair achieved fast signal detection with a rise time of 6 ns and a decay time of 33 ns. Furthermore, these experiments pave the way towards ultrafast imaging technologies using hard X-rays for many applications.

36 MATERIALS SCIENCE↗

Kelvin-Helmholtz instability as one of the key features for fast and efficient emulsification by hydrodynamic cavitation

The paper investigates the oil–water emulsification process inside a micro-venturi channel. More specifically, the possible influence of Kelvin-Helmholtz instability on the emulsification process. High-speed visualizations were conducted inside a square venturi constriction with throat dimensions of 450 µm by 450 µm, both under visible light and X-Rays. We show that cavity shedding caused by the instability results in the formation of several cavity vortices. Their rotation causes the deformation of the oil stream into a distinct wave-like shape, combined with fragmentation into larger drops due to cavitation bubble collapse. Later on, the cavity collapse further disperses the larger drops into a finer emulsion. Thus, it turns out that the Kelvin-Helmholtz instability is similarly characteristic for hydrodynamic cavitation emulsification inside a microchannel as is the Rayleigh-Taylor instability for acoustically driven emulsion formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A wide dynamic range x-ray streak camera system

An x-ray streak camera with wide dynamic range and a large slit photocathode of 30 mm length has been developed and calibrated. In order to achieve wide dynamic range, a conventional streak tube has been improved and the camera system has been designed without microchannel plate electron amplifier. As a result, a dynamic range of 922 is achieved in a single shot mode with laser pulse of 30 ps (full width at half maximum) at time resolution of better than 31 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Position-Sensitive Detector with GaAs photocathode and high time resolution

The Position-Sensitive Detector (PSD) on base of GaAs photocathode and microchannel plate set has been developed. PSD consists of thick semi-conductor photocathode with quantum efficiency about 48% in the range of 4000-7500 A, two micro-channel plates, and 16-electrode collector. The detector has spatial resolution of 20-40 microns for about 5{center_dot}10{sup 2} pixels, time resolution of 1 {mu}s and effective sensitivity up to 35%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Devices and software for optical panoramic observations with microsecond time resolution

The set of equipment and software of MANIA experiment for search for and study of astrophysical objects variability with time resolution of 1 us is described. Observations are carried out at the Russian 6-meter telescope by means of universal photospectropolarimeter. This device is equipped with different optical units which implement four observational modes--spectroscopic, spectropolarimetric, photometric, and photopolarimetric. The use of position-sensitive detector with set of microchannel plates gives possibility to register object photon fluxes in different colour bands and for different orientations of polarizer simultaneously. Acquisition system ''Quantochron 4-48'' on line with computer accumulates observational data with time resolution of 1 microsecond. The features of software intended for processing of panoramic data of high time resolution are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Fast, Near-Infrared Photodetectors for the ITER Core LIDAR Thomson Scattering

A key component for the ITER core LIDAR Thomson Scattering (TS) diagnostic would be a detector with good sensitivity in the 850-1060 nm near infrared (NIR) spectral region. Covering this spectral region becomes necessary if a Nd:YAG laser system operating at {lambda} = 1.06 {mu}m is used as the laser source, which is a very attractive choice in terms of available energy, repetition rate, reliability and cost. In this paper we review the state of the art of two types of detectors available for the above spectral range: the transferred electron (TE) InGaAs/InP hybrid photodiode and the In{sub x}Ga{sub 1-x}As microchannel plate (MCP) image intensifier and we describe the advancements necessary for a possible application in the ITER LIDAR TS. In addition we describe the preliminary characterization of new GaAsP fast MCP photomultipliers (PMTs) suitable for the detection of the visible part of the LIDAR TS spectrum in JET and ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A photoelectron-photoion coincidence imaging apparatus for femtosecond time-resolved molecular dynamics with electron time-of-flight resolution of {sigma}=18 ps and energy resolution {delta}E/E=3.5%

We report on the construction and performance of a novel photoelectron-photoion coincidence machine in our laboratory in Amsterdam to measure the full three-dimensional momentum distribution of correlated electrons and ions in femtosecond time-resolved molecular beam experiments. We implemented sets of open electron and ion lenses to time stretch and velocity map the charged particles. Time switched voltages are operated on the particle lenses to enable optimal electric field strengths for velocity map focusing conditions of electrons and ions separately. The position and time sensitive detectors employ microchannel plates (MCPs) in front of delay line detectors. A special effort was made to obtain the time-of-flight (TOF) of the electrons at high temporal resolution using small pore (5 {mu}m) MCPs and implementing fast timing electronics. We measured the TOF distribution of the electrons under our typical coincidence field strengths with a temporal resolution down to {sigma}=18 ps. We observed that our electron coincidence detector has a timing resolution better than {sigma}=16 ps, which is mainly determined by the residual transit time spread of the MCPs. The typical electron energy resolution appears to be nearly laser bandwidth limited with a relative resolution of {delta}E{sub FWHM}/E=3.5% for electrons with kinetic energy near 2 eV. The mass resolution of the ion detector for ions measured in coincidence with electrons is about {delta}m{sub FWHM}/m=1/4150. The velocity map focusing of our extended source volume of particles, due to the overlap of the molecular beam with the laser beams, results in a parent ion spot on our detector focused down to {sigma}=115 {mu}m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron radiation microdiffraction of ballistic molten wax microdrops

Using stroboscopic techniques, diffraction patterns of ballistic paraffin wax microdrops have been observed. The microdrops, generated by a high-temperature ink-jet system, travel through the 1 {mu}m synchrotron radiation beam with a speed of about 1.4 m/s. Diffraction patterns were recorded in flight by a charge couple device with a microchannel plate image intensifier stage, which was activated with the microdrop generation frequency of 1000 Hz during 2 {mu}s. The data show liquid microdrops with a constant temperature up to 8 mm from the ink-jet system capillary exit. The general technique could be adapted for studying fast structural processes, such as protein conformational changes in aqueous microdrops.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of heating laser injection time to imploded core plasma by using x-ray framing camera

A simultaneous measurement of imploded core plasma and injection time of heating laser is conducted by using an x-ray framing camera (XFC). The experiments are performed using Gekko XII laser system for implosion of the deuterated polystyrene (CD) plastic shell target and Peta Watt (PW) laser system for heating. The time of PW laser injection is observed as the bright zone in the XFC image. The measured x-ray intensity profiles fit the Gaussian profiles well. The calculations of microchannel plate by using dynode model explain these broadened temporal profiles qualitatively. The peak position of fitted x-ray intensity profile is almost in agreement with the time when the high energy x ray is observed by x-ray streak camera. Moreover, the peak position is delayed corresponding to the delayed setting of PW laser injection time. From these results, it is concluded that we can estimate the heating laser injection time with resolution of the order of 10 ps by using XFC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhancement of the JET edge LIDAR Thomson scattering diagnostic with ultrafast detectors

The edge light detection and ranging (LIDAR) Thomson scattering diagnostic at the Joint European Torus fusion experiment uses a 3 J ruby laser to measure the electron density and temperature profile at the plasma edge. The original system used a 1 GHz digitizer and detectors with response times of {approx_equal}650 ps and effective quantum efficiencies <7%. This system has recently been enhanced with the installation of a new 8 GHz digitizer and four new ultrafast GaAsP microchannel plate photomultiplier tube detectors with response times of <300 ps and effective quantum efficiencies in the range of {approx}13%-20% (averaged over {lambda}=500-700 nm). This upgrade has enabled the spatial resolution to be reduced to {approx}6.3 cm along the laser line of sight for a laser pulse of 300 ps full width at half maximum, which is close to the requirements for the ITER core LIDAR. Performance analysis shows that the new system will have an effective spatial resolution of up to 1 cm in the magnetic midplane via magnetic flux surface mapping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗