Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

R-Matrix Analysis of the Neutron-Induced Cross Sections on 143 Nd Measured at LANSC [Slides]

An established use of R-Matrix codes is being implemented at LANSCE. There are unique features accessible with detectors at LANSCE that can be used to perform more complete R-Matrix analysis. Further, Spin separation is a powerful technique that can be applied in DANCE measurements. Additionally, a unique method to measure transmission with DICER is being undertaken. Transmission and capture data were analyzed in this work. The study can be extended to other channels. The results of the 143 Nd data are presented in this work. New resonances found in this work: 21 compared to ENDF/B-VIII.0 and JEFF-3.3, and 24 compared to JENDL-5. Wrong spin assignment in 23 resonances in ENDF/B-VIII.0, 25 in JEFF-3.3 and 26 in JENDL-5. The 143 Nd and 147,149 Sm have been analyzed. Exciting future for new measurements and analysis!

97 MATHEMATICS AND COMPUTING↗

Extinct superheavy element in the Allende meteorite

Radiochemical neutron activation analysis of seven Allende samples for 26 trace elements were conducted. In addition, Cr and Fe were studied with the aid of instrumental neutron activation analysis. The investigation had the objective to identify the extinct superheavy element which was present in meteorites and decayed to Xe isotopes by spontaneous fission. The superheavy element was found to reside mainly in a rare mineral (probably a Fe, Ni, Cr, Al-sulfide), comprising only 0.04% of the meteorite. It is pointed out that of the nine volatile superheavy elements 111 to 119, only 115, 114, and 113 are expected to condense as sulfides in the temperature interval between 400 and 500 K corresponding to mineral formation conditions in the solar nebula.

Anders, E.↗

Lunar meteorites - Siderophile element contents, and implications for the composition and origin of the moon

Data for 10 siderophile elements in all of the known lunar meteorites except for Y793274 are reported. Bulk compositional data for Ni, Ge, Cd, Re, Os, Ir, and Au were obtained from radiochemical neutron activation analysis (Warren et al., 1986). Data for Fe, Co, and Zn, and additional data for Ni, Ir, and Au were obtained by instrumental neutron activation analysis (Kallemeyn et al., 1988). Except for the case of Au in Y791197, there was good agreement between the results obtained by the two methods. The differences observed between the lunar-meteoritic regolith samples and central nearside highlands regolith samples are discussed.

Warren, Paul H.↗

A sensitivity analysis to predict the neutronics behavior of samples irradiated in the VTR rabbit system

We report a low-order neutronics model is developed to carry out hundreds of simulations efficiently and investigate the neutronics behavior of samples being irradiated in a test reactor setting under different geometrical constraints. The low-order model allowed for simulations that yield the expected neutronics behavior of any irradiated sample in any environment and allows for the calculation of highly accurate spatially averaged statistics and idealized spatial distributions in the neutron flux. Several benchmarks are performed to evaluate the performance and limitations of the low-order model revealing many important findings. The low-order model predicted the LHGR in the EBR-II driver fuel to within 2.34% by only simulating the fuel rod by itself, which served as a validation for the model. Sensitivity studies investigated 3% enriched UO 2 and U-10Zr being irradiated in the Versatile Test Reactor rabbit system. The analyses investigated a range of combinations of 15 radii and 5 heights for each sample in the rabbit system. Similar data sets are also provided for irradiations in the Advanced Test Reactor’s B-10 irradiation position, which is a thermal neutron spectrum environment. Generalized fits and fit coefficients are obtained for sample heating, reaction rate densities, and local multiplication rate characteristics, allowing the predictions of the neutronics behavior of the samples based on their geometrical constraints. The analyses and fits laid the groundwork for developing a user-end Multiphysics analysis framework to assist and accelerate irradiation experiment design and optimization.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design and Benchmarking of a Proton Recoil Neutron Detector

A neutron spectroscopy detector was designed for analysis of neutrons produced by Lawrence Livermore National Laboratory's neutron imaging project. The detector was built and benchmarked at Lawrence Berkeley National Laboratory's Deuteron-Breakup Neutron Facility. Similar to a proton-recoil telescope, the setup detects protons elastically scattered from neutrons incident on a thin sheet of polyethylene. A silicon charged-particle detector several centimeters away detects the protons in a small angular range, such that the energies of the incident neutrons can be reconstructed from the energy of the detected proton and the scattering angle. A quick benchmarking experiment demonstrated that large backgrounds would be a significant challenge, and that additional measures must be taken to reduce these backgrounds. A Geant4 model of the detector was used to predict the sources of these backgrounds and how best to reduce them.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Implementation of TSL Evaluations Beyond the Incoherent Approximation [Slides]

This presentation discusses the motivation behind the project, which is to facilitate the production of TSL libraries that contain high fidelity physics including coherent inelastic effects, such as graphite and beryllium. High fidelity TSL libraries are of interest in various applications, for example in relation to neutron scattering instrument response analysis and directional biases (reflection) in neutronic analysis. In summation, the removal of typical approximations, in terms of incoherent, cubic, and atom site are examined. The application of generalized equations to crystalline graphite and beryllium TSL evaluations and the validation of data and data formats is also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Extension of Case's method to the two-region critical cylinder and its application as an analytic standard

The normal mode expansion technique is applied to the transformed monoenergetic integral transport equation to develop a solution for the rotationally invariant and axially infinite, critical, two-region cylinder with a finite outer reflector boundary. Isotropic scattering and identical neutron mean free paths in the core and reflector regions are assumed. The solution in terms of singular integral equations is obtained by applying a completeness theorem found for the singular eigenfunctions. Numerical results for a variety of core and reflector multiplying properties and reflector thickness are presented and compared with the results of other method. An example of this type of application is given in a study of approximations inherent in the neutronic design analysis of a small, fast-neutron-spectrum reactor concept proposed as a space power source.

Westfall, R. M.↗

Activation product analysis in a mixed sample containing both fission and neutron activation products

Activation analysis of gold (Au) is used to estimate neutron fluence resulting from a criticality event; however, such analyses are complicated by simultaneous production of other gamma-emitting fission products. Confidence in neutron fluence estimates can be increased by quantifying additional activation products such as platinum (Pt), tantalum (Ta), and tungsten (W). This work describes a radiochemical separation procedure for the determination of these activation products. Anion exchange chromatography is used to separate anionic forms of these metals in a nitric acid matrix; thiourea is used to isolate the Au and Pt fraction, followed by removal of the Ta fraction using hydrogen peroxide. W, which is not retained on the first anion exchange column, is transposed to an HCl/HF matrix to enhance retention on a second anion exchange column and finally eluted using HNO3/HF. Chemical separations result in a reduction in the minimum detectable activity by a factor of 287, 207, 141, and 471 for 182Ta, 187W, 197Pt, and 198Au respectively, with greater than 90% recovery for all elements. These results represent the highest recoveries and lowest minimum detectable activities for 182Ta, 187W, 197Pt, and 198Au from mixed fission-activation product samples to date, enabling considerable refinement in the measurement uncertainties for neutron fluences in highly complex sample matrices.

anion exchange↗

X-Ray Measurements Of A Thermo Scientific P385 DD Neutron Generator

Idaho National Laboratory is experimenting with electrical neutron generators, as potential replacements for californium-252 radioisotopic neutron sources in its PINS prompt gamma-ray neutron activation analysis (PGNAA) system for the identification of military chemical warfare agents and explosives. In addition to neutron output, we have recently measured the x-ray output of the Thermo Scientific P385 deuterium-deuterium neutron generator. X rays are a normal byproduct from neutron generators, but depending on their intensity and energy, x rays can interfere with gamma rays from the object under test, increase gamma-spectrometer dead time, and reduce PGNAA system throughput. The P385 x-ray energy spectrum was measured with a high-purity germanium (HPGe) detector, and a broad peak is evident at about 70 keV. To identify the source of the x rays within the neutron generator assembly, it was scanned by collimated scintillation detectors along its long axis. At the strongest x-ray emission points, the generator also was rotated 60 deg. between measurements. The scans show the primary source of x-ray emission from the P385 neutron generator is an area 60 mm from the neutron production target, in the vicinity of the ion source. Rotation of the neutron generator did not significantly alter the x-ray count rate, and its x-ray emission appears to be axially symmetric. A thin lead shield, 3.2 mm (1/8 inch) thick, reduced the 70-keV generator x rays to negligible levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Dosimetry for the University of Central Florida (UCF3) Irradiation in ATR

PNNL project 74242 involves the analysis of neutron fluence monitors irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00236287 and Statement of Work No. 17370, Rev. 0, PNNL Analysis of NSUF Flux and Melt Wire Capsules. This report is for the University of Central Florida (UCF)-3 third stage experiment which was conducted in position B8 of the ATR. Three other irradiations included in the scope of work are reported separately. The neutron fluence monitors were prepared by PNNL and loaded into the UCF-3 assemblies at INL prior to irradiation. Following irradiation, the capsules were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma analysis, and the measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at 8 fluence monitor locations. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Non-Destructive Study of Bulk Crystallinity and Elemental Composition of Natural Gold Single Crystal Samples by Energy-Resolved Neutron Imaging

Energy-resolved neutron imaging enables non-destructive analyses of bulk structure and elemental composition, which can be resolved with high spatial resolution at bright pulsed spallation neutron sources due to recent developments and improvements of neutron counting detectors. This technique, suitable for many applications, is demonstrated here with a specific study of ~5–10mm thick natural gold samples. Through the analysis of neutron absorption resonances the spatial distribution of palladium (with average elemental concentration of ~0.4 atom% and ~5 atom%) is mapped within the gold samples. At the same time, the analysis of coherent neutron scattering in the thermal and cold energy regimes reveals which samples have a single-crystalline bulk structure through the entire sample volume. A spatially resolved analysis is possible because neutron transmission spectra are measured simultaneously on each detector pixel in the epithermal, thermal and cold energy ranges. With a pixel size of 55μm and a detector-area of 512 by 512 pixels, a total of 262,144 neutron transmission spectra are measured concurrently. The results of our experiments indicate that high resolution energy-resolved neutron imaging is a very attractive analytical technique in cases where other conventional nondestructive methods are ineffective due to sample opacity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coupled 3D-neutronics / thermal-hydraulics analysis of an unprotected loss-of-flow accident for a 3600 MWth SFR core

The core behaviour of a large (3600 MWth) sodium-cooled fast reactor (SFR) is investigated in this paper with the use of a coupled TRACE/PARCS model. The SFR neutron spectrum is characterized by several performance advantages, but also leads to one dominating neutronics drawback - a positive sodium void reactivity. This implies a positive reactivity effect when sodium coolant is removed from the core. In order to evaluate such feedback in terms of the dynamics, a representative unprotected loss-of-flow (ULOF) transient, i.e. flow run-down without SCRAM in which sodium boiling occurs, is analyzed. Although analysis of a single transient cannot allow general conclusions to be drawn, it does allow better understanding of the underlying physics and can lead to proposals for improving the core response during such an accident. The starting point of this study is the reference core design considered in the framework of the Collaborative Project on the European Sodium Fast Reactor (CP-ESFR). To reduce the void effect, the core has been modified by introducing an upper sodium plenum (along with a boron layer) and by reducing the core height-to-diameter ratio. For the ULOF considered, a sharp increase in core power results in melting of the fuel in the case of the reference core. In the modified core, a large dryout leads to melting of the clad. It seems that, for the hypothetical event considered, fuel failure cannot be avoided with just improvement of the neutronics design; therefore, thermal-hydraulics optimization has been considered. An innovative assembly design is proposed to prevent sodium vapour blocking the fuel channel. This results in preventing a downward propagation of the sodium boiling to the core center, thus limiting it to the upper region. Such a void map introduces a negative coolant density reactivity feedback, which dominates the total reactivity change. As a result, the power level and the fuel temperature are effectively reduced, and a large dryout is prevented. As a next step, the classical sodium plenum is replaced by a fission gas plenum (with lower sodium fraction), thus improving flow stability. Stable boiling at a steady power level is achieved in this final configuration. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

PWR core design, neutronics evaluation and fuel cycle analysis for thorium-uranium breeding recycle

This paper was focused on core design, neutronics evaluation and fuel cycle analysis for Thorium-Uranium Breeding Recycle in current PWRs, without any major change to the fuel lattice and the core internals, but substituting the UOX pellet with Thorium-based pellet. The fuel cycle analysis indicates that Thorium-Uranium Breeding Recycle is technically feasible in current PWRs. A 4-loop, 193-assembly PWR core utilizing 17 x 17 fuel assemblies (FAs) was taken as the model core. Two mixed cores were investigated respectively loaded with mixed reactor grade Plutonium-Thorium (PuThOX) FAs and mixed reactor grade {sup 233}U-Thorium (U{sub 3}ThOX) FAs on the basis of reference full Uranium oxide (UOX) equilibrium-cycle core. The UOX/PuThOX mixed core consists of 121 UOX FAs and 72 PuThOX FAs. The reactor grade {sup 233}U extracted from burnt PuThOX fuel was used to fabrication of U{sub 3}ThOX for starting Thorium-. Uranium breeding recycle. In UOX/U{sub 3}ThOX mixed core, the well designed U{sub 3}ThOX FAs with 1.94 w/o fissile uranium (mainly {sup 233}U) were located on the periphery of core as a blanket region. U{sub 3}ThOX FAs remained in-core for 6 cycles with the discharged burnup achieving 28 GWD/tHM. Compared with initially loading, the fissile material inventory in U{sub 3}ThOX fuel has increased by 7% via 1-year cooling after discharge. 157 UOX fuel assemblies were located in the inner of UOX/U{sub 3}ThOX mixed core refueling with 64 FAs at each cycle. The designed UOX/PuThOX and UOX/U{sub 3}ThOX mixed core satisfied related nuclear design criteria. The full core performance analyses have shown that mixed core with PuThOX loading has similar impacts as MOX on several neutronic characteristic parameters, such as reduced differential boron worth, higher critical boron concentration, more negative moderator temperature coefficient, reduced control rod worth, reduced shutdown margin, etc.; while mixed core with U{sub 3}ThOX loading on the periphery of core has no visible impacts on neutronic characteristics compared with reference full UOX core. The fuel cycle analysis has shown that {sup 233}U mono-recycling with U{sub 3}ThOX fuel could save 13% of natural uranium resource compared with UOX once through fuel cycle, slightly more than that of Plutonium single-recycling with MOX fuel. If {sup 233}U multi-recycling with U{sub 3}ThOX fuel is implemented, more natural uranium resource would be saved. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutrino fast flavor oscillations with moments: Linear stability analysis and application to neutron star mergers

Providing an accurate modeling of neutrino physics in dense astrophysical environments such as binary neutron star mergers presents a challenge for hydrodynamic simulations. Nevertheless, understanding how flavor transformation can occur and affect the dynamics, the mass ejection, and the nucleosynthesis will need to be achieved in the future. Computationally expensive, large-scale simulations frequently evolve the first classical angular moments of the neutrino distributions. By promoting these quantities to matrices in flavor space, we develop a linear stability analysis of fast flavor oscillations using only the first two “quantum” moments, which notably requires generalizing the classical closure relations that appropriately truncate the hierarchy of moment equations in order to treat quantum flavor coherence. After showing the efficiency of this method on a well-understood test situation, we perform a systematic search of the occurrence of fast flavor instabilities in a neutron star merger simulation. Here, we discuss the successes and shortcomings of moment linear stability analysis, as this framework provides a time-efficient way to design and study better closure prescriptions in the future.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of NIF experiments with the minimal energy implosion model

We apply a recently developed analytical model of implosion and thermonuclear burn to fusion capsule experiments performed at the National Ignition Facility that used low-foot and high-foot laser pulse formats. Our theoretical predictions are consistent with the experimental data. Our studies, together with neutron image analysis, reveal that the adiabats of the cold fuel in both low-foot and high-foot experiments are similar. That is, the cold deuterium-tritium shells in those experiments are all in a high adiabat state at the time of peak implosion velocity. The major difference between low-foot and high-foot capsule experiments is the growth of the shock-induced instabilities developed at the material interfaces which lead to fuel mixing with ablator material. Furthermore, we have compared the NIF capsules performance with the ignition criteria and analyzed the alpha particle heating in the NIF experiments. Our analysis shows that alpha heating was appreciable only in the high-foot experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗