Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Achieving a near-ideal silicon crystal neutron interferometer using submicrometer fabrication techniques

Perfect-crystal neutron interferometry, which is analogous to Mach-Zehnder interferometry, uses Bragg diffraction to form interfering neutron paths. The measured phase shifts can be used to probe many types of interactions whether it be nuclear, electromagnetic, gravitational, or topological in nature. For a perfect-crystal interferometer to preserve coherence, the crystal must possess a high degree of dimensional tolerance as well as being relatively defect-free with minimal internal stresses. In the past, perfect-crystal neutron interferometers have been produced by a two-step process. First, a resin diamond wheel would be used to remove excess material and shape the interferometer. Afterword, the crystal would be etched to remove surface defects and elevate strains. This process has had limitations in terms of repeatability and in maximizing the final contrast, or fringe visibility, of the interferometer. We have tested various fabrication and post-fabrication techniques on a single perfect-crystal neutron interferometer and measured the interferometer's performance at each step. Here we report a robust, nonetching fabrication process with high final contrast. For the interferometer used in this work, we achieved contrasts of greater than 90% several times and ultimately finished with an interferometer that has 92% contrast and a uniform phase distribution. Published by the American Physical Society 2024

Huber, M. G. (ORCID:0000000237958445)↗

Measuring the angular momentum of a neutron using Earth's rotation

A coupling between Earth's rotation and orbital angular momentum (OAM), known as the Sagnac effect, is observed in entangled neutrons produced using a spin-echo interferometer. After correction for instrument systematics the measured coupling is within 5% of theory, with an uncertainty of 7.2%. The OAM in our setup is transverse to the propagation direction and scales linearly with neutron wavelength (4–12.75 Å), so the Sagnac coupling can be varied without mechanically rotating the device, which avoids systematic errors present in previous experiments. The detected transverse OAM of our beam corresponds to 4098 ± 295 ℏ Å − 1 , 10 5 times lower than in the previous neutron experiments. This demonstrates the feasibility of using the Sagnac effect to definitively measure neutron OAM and paves the way towards a future observation of the quantum Sagnac effect. Published by the American Physical Society 2025

Geerits, Niels (ORCID:0000000248072084)↗

Exploring 𝛽 decay and 𝛽-delayed neutron emission in exotic 46,47 Cl isotopes

In this paper, 𝛽 − and 𝛽-delayed neutron decays of 46,47 Cl are reported from an experiment carried out at the National Superconducting Cyclotron Laboratory using the Beta Counting System. The half-lives of both 46 Cl and 47 Cl were extracted. Based on the delayed 𝛾-ray transitions observed, the level structure of 𝑁=28 46 Ar was determined. Completely different sets of excited states above the first 2 + state in 46 Ar were populated in the 46 Cl 𝛽⁢0⁢𝑛 and 47 Cl 𝛽⁢1⁢𝑛 decay channels. Two new 𝛾-ray transitions in 47 Ar were identified from the very weak 47 Cl 𝛽⁢0⁢𝑛 decay. Furthermore, 46 Cl 𝛽⁢1⁢𝑛 and 47 Cl 𝛽⁢2⁢𝑛 were also observed to yield different population patterns for levels in 45 Ar, including states of different parities. Here, the experimental results allow us to address some of the open questions related to the delayed neutron emission process. For isotopes with large neutron excess and high 𝑄 𝛽 values, delayed neutron emission remains an important decay mode and can be utilized as a powerful spectroscopic tool. Experimental results were compared with shell-model calculations using the FSU and 𝑉 MU effective interactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Seniority Structure in Neutron-Rich Nucleus 128 Ag : Evidence for Robustness of 𝑁 = 82 Shell Closure in Silver Isotopes

The spectroscopic studies of very neutron-rich nucleus 128 Ag have been performed for the first time at the Radioactive Isotope Beam Factory of RIKEN. A new seniority isomer with a half-life of 1.60(7) μs has been identified and is proposed to have a spin-parity of 16 - with a maximally aligned configuration comprising three proton holes in the g 9/2 orbital and one neutron hole in the h 11/2 orbital. The new level structure in 128 Ag is quite well described by shell model calculations without invoking excitations across the Z = 50 and N = 82 shell gaps, and presents a good case of seniority scheme in odd-odd nuclei in the south vicinity of the double-magic nucleus 132 Sn. With a classification of various components of the proton-neutron interaction, the inversion of lowest-lying 9 - and 10 - states between 128 Ag and its neighboring isotone 130 In is found to be dynamically ascribed to the seniority-nonconserving proton-neutron interaction components. The structure above 10 - up to the 16 - isomer in 128 Ag shows remarkable similarities to seniority structures in the semimagic nuclei 128 Pd and 130 Cd. These spectroscopic features in 128 Ag indicate that the N = 82 shell closure is still robust in silver isotopes.

Luo, D. W. [Peking University, Beijing (China); et↗

Beta-Delayed Neutron Emission of 𝑁=84 132Cd

Using the time-of-flight technique, we measured the beta-delayed neutron emission of 132 Cd . From our large-scale shell model (LSSM) calculation using the N3⁢LO interaction [, Phys. Rev. Lett. 131, 022501 (2023)], we suggest the decay is dominated by the transformation of a neutron in the 𝑔7/2 orbital, deep below the Fermi surface, into a proton in the 𝑔9/2 orbital. We compare the beta-decay half-lives and neutron branching ratios of nuclei with 𝑍<50 and 𝑁 ≥82 obtained with our LSSM with those of leading “global” models such as finite-range droplet model (FRDM). Our calculations match known half-lives and neutron branching ratios well and suggest that current leading models overestimate the yet-to-be-measured half-lives. Our model, backed by the 132 Cd decay data presented here, offers robust predictive power for nuclei of astrophysical interest such as 𝑟-process waiting points.

Madurga, M [Department of Physics and Astronomy, U↗

Resonant neutron scattering lengths

Unlike most of the periodic table, many rare-earth elements display considerable resonant scattering for thermal neutrons. Although this property is accompanied by strong neutron absorption, modern high-intensity neutron sources make diffraction experiments possible with these elements. Computation of scattering intensities is accomplished by fitting the variation in resonant scattering lengths ( b 0 , b ′ and b ′′) to a semi-empirical Breit–Wigner formalism, which can be evaluated over the range of neutron energies useful for diffraction, typically E = 10–600 meV; λ = 0.4–2.8 Å (with good extrapolation to longer wavelengths).

Von Dreele, Robert B. (ORCID:0000000253390634)↗

Transient Optimization of the Cryogenic Moderator System Controller at the Spallation Neutron Source for Improved Performance

The high-energy neutron beam generated at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is moderated to use cold (slow) neutrons for scientific discoveries. The Cryogenic Moderator System (CMS) removes heat from the neutron beam using cryogenic hydrogen (H 2 ) moderators connected via heat exchangers to a helium (He) refrigeration loop that dissipates heat using a compressor-brake system. However, the CMS is affected by sporadic losses in beam power, referred to as "beam trips," as these events generate significant disturbances in cooling requirements. To accommodate the heat load transients during beam trips, the CMS uses a decentralized control strategy consisting of four flow valves and one electric heater adjusted by independent proportional-integral (PI) controllers. During the CMS’s initial commissioning, the PI gains were calibrated based only on tracking performance, overlooking their effectiveness in disturbance rejection. A data-driven, control-oriented closed-loop model was developed to recalibrate the PI gains and minimize the transient disturbances caused by beam trips. The model consists of three main components: (1) a physics-based model of the He refrigeration loop, (2) a machine-learning model of the cryogenic H 2 cooling trains, and (3) the control logic used for feedback set-point tracking. Experimental results showed that the recalibrated gains obtained in this study improved the CMS’s transient response during beam trips.

Maldonado Puente, Bryan↗

X-ray and Neutron Radiography for Quantitative Material Reconstructions

Radiography is a powerful tool to determine the interior structure of objects. X-ray radiography is widely used and provides high-resolution images, though X-rays have limited transmission through materials of high atomic number (Z) and density. In contrast, neutrons can penetrate many materials that are heavily attenuating to X-rays, such as metals, providing contrast in the inner layers of highly attenuating items. Past work has shown the value in using both X-ray and neutron radiography for estimating material thicknesses, though that work was limited to simulated data. Here, we demonstrate quantitative material reconstructions using experimental X-ray and neutron radiography data from lab-based systems, accurately modeling radiography system responses to within a few percent to enable quantitative measures of material thickness. We demonstrate the utility of neutron radiography and X-ray radiography for these quantitative reconstructions and introduce methods for using their complementarity to improve image quality and optimize experimental design.

Gilbert, Andrew J.↗

Neutron and Gamma-Ray Imaging of Th-232 and Cm-244 Using Organic Glass Scintillators

Modern nuclear safeguards require detection and characterization capabilities suitable for a wide variety of radiation sources and applications. Field-deployable detection systems have also had to modernize to meet changing needs. Recent developments in organic scintillator technology have resulted in the creation of an organic glass scintillator (OGS) at Sandia National Laboratory which is composed of a 9:1 mixture of glass compounds C42H36Si and C51H44Si. The novel scintillator composition was implemented into the design for a dual-particle capable imaging system at the University of Michigan. This work presents new results from two experiments demonstrating the gamma-ray and fast-neutron imaging capabilities of the organic glass system. Gamma spectroscopy was also performed using CeBr3 scintillators that are part of the imager design. Measurements were performed at Lawrence Livermore National Laboratory using 232Th metal hemishells and an encapsulated 244Cm oxide source. Successful gamma-ray imaging of the 232Th distributed sources is demonstrated with the glass imager, but there were no appreciable neutrons from the 232Th for neutron imaging. Promising neutron and gamma-ray imaging results of 244Cm are demonstrated despite limited imaging event statistics available in this measurement. Gamma-ray spectroscopy results were able to identify 232Th using prominent emissions at 239, 338, 583, and 911 keV. 244Cm was identified from emissions of 43, 99, and 153 keV. These results demonstrate the potential of organic glass imaging for nuclear nonproliferation or characterization efforts.

Lopez, Ricardo [Univ. of Michigan, Ann Arbor, MI (↗

Integrated Neutronics Modeling for Inertial Fusion Energy Systems: Development and Application to LD-FIRST

Lawrence Livermore National Laboratory (LLNL) is proposing a new Laser Driven Fusion Integration Research and Science Test Facility (LD-FIRST) with the goal of providing an experimental testbed for future Inertial Fusion Energy (IFE) systems. However, IFE systems require detailed and accurate multiphysics modeling to quantify material damage, thermal loading, and tritium breeding within complex chamber environments. This article presents the first step in an integrated multiphysics framework that couples meshed CAD-based geometry within Monte Carlo neutronic simulations to enable high-fidelity analysis of IFE chamber concepts, with future coupling to external codes. The neutronics workflow utilizes OpenMC and its third-party capability to use CAD-based geometries through DAGMC and tally on unstructured meshes with Libmesh to evaluate neutron transport behavior, geometric fidelity, and material performance under reactor-relevant conditions. The use of tailored tallies on unstructured meshes in this framework allows direct transfer without interpolating to CFD simulation tools. Two IFE chambers were evaluated, both conceived by LLNL: HYLIFE-II and Laser IFE (LIFE). This work produced high-fidelity conformal surface and volumetric meshes of the HYLIFE-II and LIFE chambers with mapped spatial insight into material damage, thermal loading, and tritium breeding. The HYLIFE-II model was built utilizing available resources and used as a test case to verify that the neutronics framework can handle complex geometries. The LIFE chamber CAD was provided by LLNL and was the main focus of this work. This work analyzes multiple ternary alloy breeding materials for the LIFE chamber, across different 6 Li enrichments to produce data relevant to the LD-FIRST project. This work also investigates the level of model fidelity for the LIFE chamber, and results show that inclusion of detailed first wall and coolant structures increased the predicted tritium breeding ratio (TBR) by ~30%, highlighting the sensitivity of tritium breeding and the need for a high-fidelity simulation framework for IFE chambers. These developments provide a scalable toolset for the design and optimization of next-generation IFE chambers, forming a solid foundation for future coupled multiphysics analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of shape/phase transition regions on neutron capture cross sections

Abstract A recent study found a new, purely empirical correlation between two-neutron separation energies and neutron capture cross sections in keV neutron energy regimes. In shape/phase transition regimes, such as that near A= 150, S $$_{2n}$$ 2 n values show an anomaly—a flattening of the normal near linear decrease with neutron number. This paper addresses two questions: (1) Using this new correlation, is this anomaly in S $$_{2n}$$ 2 n values sizeable enough to produce an observable effect in capture cross sections? and (2) Can the correlation be used to quantitatively reproduce the cross sections in the transition region? It is found that the answer to both questions is in the affirmative. Possible relations to the r -process are briefly discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Universality of Collective Density Fluctuations in Liquids at and away from Equilibrium – An Integrated Neutron Scattering, Theoretical, and Computational Study (Final Technical Report)

Liquids, ubiquitous on earth, are prototypical disordered condensed matter. As the mediate phase between non-structured gases and ordered solids, liquids p ossess intriguing complexities that are absent on either extreme counter phase, especially when they are driven away from equilibrium. Despite decades of studies, the physics of liquids still keeps surprising us and challenges our understanding of condensed matter, emergent phenomena, and complex systems. Among the many interesting properties, the nature of collective dynamics in liquids remains elusive because of both the presence of strong interactions and the absence of translational invariance. This project studied the universal features of collective density fluctuations (or collective modes), which include both phonon-like excitations and collective relaxations, in the Q-dependent generalized hydrodynamic regime in liquids and liquid-like matter both at and away from equilibrium. We performed systematic studies of the fast collective dynamics (including both phonon-like excitations and collective relaxations) of four classes of liquids characterized by different fragilities and interactions using synergistically integrated coherent neutron scattering experiments (Inelastic Neutron Scattering (INS), Quasi-Elastic Neutron Scattering (QENS), and Neutron Spin Echo (NSE)), a ViscoElastic Hydrodynamics theory we have been developing, andMolecular Dynamics (MD) simulations and our analysis package LiquidLib. The transformative knowledge of the collective dynamics in liquids is important to understand and ultimately control the transport of mass, energy, and charge in liquids, both at and away from thermal equilibrium, which may will likely impact a wide range of disciplines.

36 MATERIALS SCIENCE↗

Status Report on Characterization of High Burnup Fuel with Advanced Nondestructive Pulsed Neutron PIE

Characterizing irradiated or spent nuclear fuels with pulsed neutron techniques provides microstructural data such as phase fractions as well as crystallographic data, e.g. lattice parameters, from diffraction analysis. Diffraction characterization is complemented by spatially resolved mapping of isotope densities from energy-resolved neutron imaging, in particular neutron absorption resonance imaging, and overall bulk isotope assay with better sensitivity for minority isotopes from neutron absorption resonance spectroscopy without spatial resolution. Furthermore, after characterization at ambient condition, heating of irradiated or spent fuel will allow to characterize differences of e.g. lattice thermal expansion or phase transition temperature and kinetics compared to fresh fuel as well as enable the study of disappearance of irradiation defects. This data enables benchmarking of predictions of properties of irradiated fuels for which otherwise experimental data is sparse. The effort described here strives to characterize a section cut from a high-burnup fuel. Volumes smaller than entire fuel pellets or rodlets as proposed here, e.g. sections cut from a fuel pellet, to pave the way to characterize entire pellets or rodlets in the future.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Identification Capabilities in MicroBooNE Through the Application of Machine Learning with Blips

Neutrinos (ν) are subatomic particles first observed in 1956 by LANL physicists Clyde Cowan and Frederick Reines but first theorized by Wolfgang Pauli in 1930. Neutrinos are the least massive known particle and are classified as leptons with 3 flavors corresponding to their leptonic counterparts (electron, muon, and tau). We know that they are abundant, 65 billion neutrinos travel through your fingertip every second, and elusive, a single neutrino could fly through a lightyear of lead without interacting at all. Though, there is much still unknown and a better characterization of these “ghostly” particles can give us clues as to the matter/anti-matter asymmetry in the early universe and possible glimpses into new physics. To measure a particle that is extremely light and rarely interacting, physicists have developed an extremely sensitive detector known as a Liquid Argon Time Projection Chamber (LArTPC). The fiducial volume (or TPC) is bombarded with neutrinos, some of which interact with argon (Ar) atoms to produce particles that in turn excite and ionize the Ar. The products of these are free electrons which then drift through the TPC’s applied magnetic field towards a multi-plane wire readout system. The electrons’ charge is collected at this anode and the light from the initial interactions is collected by photomultiplier tubes (PMTs). In conjunction, these mechanisms allow LArTPCs to achieve millimeter spatial resolution and sub-MeV energy thresholds. The detector of interest in this study is the MicroBooNE Experiment at Fermilab. MicroBooNE is an above ground LArTPC with dimensions of approximately 10m × 2.5m × 2.3m, about the size of a school bus. Its purpose is to study neutrinos, so to improve rates of measured ν interactions, the detector is squarely in the path of the Booster Neutrino Beam (BNB) at Fermilab. A major challenge in neutrino studies is energy reconstruction, much of the neutrino’s original energy is lost in interactions that the detector is not sensitive to, often due to low-energy products. The initial goal of this analysis was to better identify neutrons, the main source of poor energy reconstruction in neutrino events. Because neutrons are neutral particles, like neutrinos, we can only directly measure the products of their interactions in LArTPCs. Most of these products are low-energy signals and while each one contributes a negligible amount of energy, collectively these signals make up most of the lost energy in each neutrino event. We define these signals as blips; point-like, isolated depositions of charge in the detector. Blips have MeV-scale energies and are the size of a single hit (charge deposition) or a cluster of a few hits on at least two wire planes. Blips are the principal detector features used to study low-energy physics; thus, they are the key to unlocking information not only about neutrons but gamma photons, supernova and solar neutrinos as well as helping us better identify certain particles. Therefore, this analysis strives to use blips for improved neutron identification (ID) and characterization.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron Fluence and Kerma Responses to Bare, Steel-Reflected, and Lucite-Reflected Steady-State Operations of the ORNL Health Physics Research Reactor

The experiments evaluated in this report were conducted at the Health Physics Research Reactor (HPRR), also known as the Fast Burst Reactor. The reactor was designed and built at Oak Ridge National Laboratory (ORNL) in 1961. In this evaluation, a total of 12 experiments were evaluated (6 shield configurations and two responses). Six of them are considered acceptable as benchmark experiments and are thoroughly described: the measurands are bare, steel-shielded and Lucite-shielded neutron fluences and neutron KERMA responses to steady-state operations of the HPRR. It is important to mention that there is a general lack of information in the experimental methodology and neutron spectrum unfolding, and in some cases, unexpected and unexplained discrepancies between calculation and experiment. The HPRR’s unique characteristics were that it is a fast reactor, the use of a Lucite shield as the shielding material, and the use of the neutron fluence as the main benchmark measurand. There are no known, significant correlations between benchmarks in this evaluation and benchmarks in other evaluations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CONNECT Neutronics Initial Report

This report represents the first status update from the Creation of Next-generation Nuclear Energy Computational Technology (CONNECT) effort within the Nuclear Energy Advanced Modeling and Simulation (NEAMS) Program and is intended to satisfy the reporting requirements of the following milestones: • M3MS-24OR0101321: Assess needs, requirements and opportunities for high-fidelity neutronics and transport as used in DOE-NE program. • M3MS-24AN0101301: Generate a community report on the needs, requirements, and opportunities for high-fidelity neutronics and transport as used in DOE-NE programs and industry. • M3MS-24OR0202433: Implement and assess numerical strategies leveraging Monte Carlo neutron transport on GPUs for production analysis. In particular, Sections 1, 2, and 3 detail the assessment of the current state of practice and the landscape of the broader advanced computing world to meet the objectives of M3MS-24OR0101321 and M3MS-24AN0101301, while Sections 4 and 5 describe new work during FY24 to extend current GPU Monte Carlo capabilities in areas relevant to active NEAMS development to satisfy M3MS-24OR0202433. Section 6 offers some thoughts about the potential future impact of Monte Carlo neutronics on NEAMS and the nuclear industry.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Godiva IV Thermal Neutron Dosimetry Modeling and Variance Reduction

The transfer of the Godiva IV experiment from the Los Alamos Critical Experiments Facility (LACEF) to the National Critical Experiments Research Center (NCERC) introduced a vastly different experiment room return to the neutron flux. The contribution of the background to the burst neutron energy spectrum is significant in the thermal and epithermal neutron energies. Target materials may be placed in various locations in the Godiva room, or outside of the room, for thermal neutron activation. Modeling of this dosimetry problem in Monte Carlo N-Particle (MCNP) presented a novel challenge compared to previous Godiva IV glory hole irradiation simulations. An advanced dosimetry modeling framework for high efficiency calculations in locations far from the Godiva IV fission source was desired. The mesh-based weight windows and point detector advanced variance reduction techniques in MCNP were implemented and tested using adaptations of the critical experiment benchmark model of the Godiva IV problem. The models were validated against measured activations of Nickel, Indium, Scandium, and Cobalt foils at locations 2 meters from the Godiva IV core. Dosimetry measurements were performed in collaboration with Sandia National Laboratory. The weight windows and point detector variance reduction coupled method resulted in the highest problem efficiency.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Delayed Neutron Temporal Signatures for Uranium Enrichment Measurement NA-241 SGTech (Final Report)

Nondestructive determination of uranium enrichment is a core capability for nuclear material accounting and control (NMAC) and safeguards verification measurements; however, traditional gamma spectroscopy-based techniques for enrichment measurement rely on significant assumptions of material composition and geometry, precluding their use in scenarios where a heterogeneous spatial distribution of enrichments is encountered. As an alternative, we are developing a technique to use delayed neutron temporal signatures for the measurement of uranium enrichment. Each uranium isotope has unique delayed neutron group yields, resulting in a unique delayed neutron decay time profile which can be analyzed to determine enrichment without the need for calibration sources. As part of this effort, we performed a series of measurement campaigns in which we used an active well coincidence counter (AWCC) retrofitted with commercial D-D and D-T generators to evaluate the operational characteristics of this method in response to a set of uranium enrichment and mass standards, as well as representative diversion scenarios in which either “concealed” enriched uranium is shielded by depleted uranium or declared enriched uranium is “hollowed out” and replaced with a central region of depleted uranium. A standard operating procedure and best practices were compiled to facilitate the use of delayed neutron-based enrichment measurements for international safeguards inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗