Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Wide-Field InfraRed Survey Telescope (WFIRST) Slitless Spectrometer: Design, Prototype, and Results

The slitless spectrometer plays an important role in the Wide-Field InfraRed Survey Telescope (WFIRST) mission for the survey of emission-line galaxies. This will be an unprecedented very wide field, HST quality 3D survey of emission line galaxies. The concept of the compound grism as a slitless spectrometer has been presented previously. The presentation briefly discusses the challenges and solutions of the optical design, and recent specification updates, as well as a brief comparison between the prototype and the latest design. However, the emphasis of this paper is the progress of the grism prototype: the fabrication and test of the complicated diffractive optical elements and powered prism, as well as grism assembly alignment and testing. Especially how to use different tools and methods, such as IR phase shift and wavelength shift interferometry, to complete the element and assembly tests. The paper also presents very encouraging results from recent element tests to assembly tests. Finally we briefly touch the path forward plan to test the spectral characteristic, such as spectral resolution and response.

Grism↗

Characterization of NiC Multilayer Coating Stress for X-Ray Optic Applications

NiC multilayers have been identified as a promising coating design for hard X-ray astrophysical imaging applications enabling bandpass extension beyond the Pt K-edge of approximately 78 keV. However, these coatings are difficult to deposit with low interfacial roughness below a bilayer thickness of about 35 ˚A. Utilizing a DC magnetron sputtering system, NiC multilayer of varying d-spacings are deposited on flat Si wafers and characterized using 8.048 keV X-ray reflectometry measurements. The residual coating stress is also measured using interferometry. We investigate how deposition parameters affect both the coating quality (i.e. surface/interfacial roughness, density, etc.) and the residual coating stress. From these experimental results conducted on flat substrates, we employ FEM and ray trace simulations to determine how NiC multilayer stress could impact the figure, and therefore performance, of full shell X-ray optics.

mulitlayer↗

The Lunar and Planetary Laboratory and its telescopes.

The campus and observatory facilities of the Lunar and Planetary Laboratory at the University of Arizona are described, with particular reference to the Space Sciences Building and its Optical Shop. The Catalina Observatory (located on a peak of the Catalina Mountains, 36 miles from the University) and its facilities intended for planetary photography, near-infrared spectroscopy and interferometry, far-infrared broadband photometry and image scanning, and studies of asteroids, comets, and other stellar studies are discussed. The layout, facilities, and telescopes of the Mount Lemmon Observatory intended for infrared astronomical research are also covered.

Kuiper, G. P.↗

Holographic interferometry with an injection seeded Nd:YAG laser and two reference beams

The performance of twin injection seeded Nd:YAG lasers is compared with the performance of an argon-ion laser for recording dual-reference-beam holograms in AGFA 8E56 emulsion. Optical heterodyning is used to measure interference, and the results are expressed in terms of heterodyning signal level and intensity signal-to-noise. The Nd:YAG laser system is to be used for optical inspections of structures for cracks, defects, gas leaks, and structural changes.

Decker, Arthur J.↗

Holographic interferometry with an injection seeded Nd:YAG laser and two reference beams

The performance of twin injection seeded Nd:YAG lasers is compared with the performance of an argon-ion laser for recording dual-reference-beam holograms in AGFA 8E56 emulsion. Optical heterodyning is used to measure interference, and the results are expressed in terms of heterodyning signal level and intensity signal-to-noise. The Nd:YAG laser system is to be used for optical inspections of structures for cracks, defects, gas leaks, and structural changes.

Decker, Arthur J.↗

A sounding rocket program in extreme and far ultraviolet interferometry

A self-compensating, all reflection interferometric (SCARI) spectrometer was developed that can provide high resolution measurements of spectral features at any wavelength. Several mechanical components were developed that aid the instrument's performance at the short wavelength range. Examples include an optical bench and modular removable precision mechanisms for alignment. Upon alignment and lock down of the interferometer with the latter, the device is removed to minimize weight. A ray-trace code was developed to simulate the instrument's performance. Interference patterns were obtained at the shortest wavelength: the hydrogen Lyman alpha (1216 A). A laboratory instrument was developed that will be flown aboard a Black Brant sounding rocket to study the very local interstellar medium.

Chakrabarti, S.↗

Stroboscopic Interferometer for Measuring Mirror Vibrations

Stroboscopic interferometry is a technique for measuring the modes of vibration of mirrors that are lightweight and, therefore, unavoidably flexible. The technique was conceived especially for modal characterization of lightweight focusing mirror segments to be deployed in outer space; however, the technique can be applied to lightweight mirrors designed for use on Earth as well as the modal investigation of other optical and mechanical structures. To determine the modal structure of vibration of a mirror, it is necessary to excite the mirror by applying a force that varies periodically with time at a controllable frequency. The excitation can utilize sinusoidal, square, triangular, or even asynchronous waveforms. Because vibrational modes occur at specific resonant frequencies, it is necessary to perform synchronous measurements and sweep the frequency to locate the significant resonant modes. For a given mode it is possible to step the phase of data acquisition in order to capture the modal behavior over a single cycle of the resonant frequency. In order to measure interferometrically the vibrational response of the mirror at a given frequency, an interferometer must be suitably aligned with the mirror and adjustably phase-locked with the excitation signal. As in conventional stroboscopic photography, the basic idea in stroboscopic interferometry is to capture an image of the shape of a moving object (in this case, the vibrating mirror) at a specified instant of time in the vibration cycle. Adjusting the phase difference over a full cycle causes the interference fringes to vary over the full range of motion for the mode at the excitation frequency. The interference-fringe pattern is recorded as a function of the phase difference, and, from the resulting data, the surface shape of the mirror for the given mode is extracted. In addition to the interferometer and the mirror to be tested, the equipment needed for stroboscopic interferometry includes an arbitrary-function generator (that is, a signal generator), an oscilloscope, a trigger filter, and an advanced charge-coupled-device (CCD) camera. The optical components are positioned to form a pupil image of the mirror under test on the CCD chip, so that the interference pattern representative of the instantaneous mirror shape is imaged on the CCD chip.

Stahl, H. Philip↗

Terrestrial Planet Finder cryogenic delay line development

Delay lines provide the path-length compensation that makes the measurement of interference fringes possible. When used for nulling interferometry, the delay line must control path-lengths so that the null is stable and controlled throughout the measurement. We report on a low noise, low disturbance, and high bandwidth optical delay line capable of meeting the TPF interferometer optical path length control requirements at cryogenic temperatures.

cryogenic↗

Single-dish and VLBI Observations of Cygnus X-3 During the 2016 Giant Flare Episode

In 2016 September, the microquasar Cygnus X-3 underwent a giant radio flare, which was monitored for 6 d with the Medicina Radio Astronomical Station and the Sardinia Radio Telescope. Long observations were performed in order to follow the evolution of the flare on an hourly scale, covering six frequency ranges from 1.5 to 25.6 GHz. The radio emission reached a maximum of 13.2 +/- 0.7 Jy at 7.2 GHz and 10 +/- 1 Jy at 18.6 GHz. Rapid flux variations were observed at high radio frequencies at the peak of the flare, together with rapid evolution of the spectral index: α steepened from 0.3 to 0.6 (with Sν ∝ ν −α) within 5 h. This is the first time that such fast variations are observed, giving support to the evolution from optically thick to optically thin plasmons in expansion moving outward from the core. Based on the Italian network (Noto, Medicina and SRT) and extended to the European antennas (Torun, Yebes, Onsala), very long baseline interferometry (VLBI) observations were triggered at 22 GHz on five different occasions, four times prior to the giant flare, and once during its decay phase. Flux variations of 2 h duration were recorded during the first session. They correspond to a mini-flare that occurred close to the core 10 d before the onset of the giant flare. From the latest VLBI observation we infer that 4 d after the flare peak the jet emission was extended over 30 mas.

Egron, E.↗

Portable fiber optic coupled Doppler interferometer system for detonation and shock wave diagnostics

Testing and analysis of shock wave characteristics such as detonators and ground shock propagation frequently require a method of measuring velocity and displacement of the surface of interest. One method of measurement is Doppler interferometry. The VISAR (Velocity Interferometer System for Any Reflector) uses Doppler interferometry and has gained wide acceptance as the preferred tool for shock measurement. An important asset of VISAR is that it measures velocity and displacement nonintrusively.

Fleming, Kevin J.↗

Results from the TOM3 testbed: thermal deformation of optics at the picometer Level

We have discussed the TOM3 testbed developed to assess the thermo-opto-mechanical stability of optical assembly such as SIM's siderostat and telescope in flight-like thermal conditions. Although limited by the metrology sensor noise, test results show that optical wavefront stability of SIM's optical assembly is compatible with single micro-arcsecond astrometry.

Space Interferometer Mission (SIM)↗

Atom Interferometry for Detection of Gravitational Waves: NASA Institute for Advanced Concepts (NIAC) - Phase 1 Final Report

This report presents the results of the 2012-2013 NASA Institute for Advanced Concepts (NIAC) Phase 1 "Atom Interferometry for Detection of Gravitational Waves" project. The origin of this GW (Gravitational Wave) detection concept using atoms can be traced to theoretical work that first appeared in 2008 and also to a satellite mission-focused followup study that was done in 2011. The goal of the current project was to explore both theoretical and technical issues surrounding the implementation of this idea, as well as to begin performing proof-of-concept experiments to validate critical aspects of the proposal.The top level trade space for the detector design is driven by the strategy employed to mitigate laser frequency noise, which, if uncontrolled, can mask GW signatures. One of the advantages of the atom interferometric approach is the possibility of single baseline detection (Fig. 1.1), even in the presence of laser noise. This is enabled by the differential measurement between the two ensembles of atoms, which can result in substantial laser noise suppression. The details of this suppression depend on the atomic physics techniques used to implement the atom interferometry. Specifically, we considered the effect on noise suppression that results from using traditional two-photon Raman transitions (with alkali atoms) and also single-photon transitions (with alkaline earth-like atoms).The interferometers shown in Fig 1.1(b) take advantage of single-photon transitions (as opposed to traditional Raman transitions) because using light pulses from one direction at a time allows for near perfect common-mode cancellation of laser phase noise, even for long baselines. This calls for the use of atomic transitions with an (ideally large) optical energy level difference with a long (greater than 1 second) lifetime, such as high-transitions routinely used for optical atomic clocks in species like Sr, Ca and Yb. Notably, large momentum transfer (LMT) atom optics - and the sensitivity enhancement they confer – can still be realized by simply adding additional pairs of alternating pulses to each beam splitter process. Section 3 reports on the theoretical work we performed to justify this GW detection protocol using single-photon transitions. This approach represents a new method for GW detection using atoms that is distinct from the original proposal from 2008. At the system level, we evaluated three architectures, each of which implements a different solution to the laser frequency noise issue. The first two designs are based on two-photon Raman transitions with Rb atoms. One of these is a three-satellite, multiple baseline design while the other is a two-satellite, single baseline design. The third proposal is a two-satellite, single baseline design that uses single-photon transitions with Sr atoms. These three architectures are described in more detail in Section 2. There are a number of known technical issues that we have started to address using ground-based experiments. These issues include atom technology development needs such as, for example, lower ensemble temperature requirements and large momentum transfer (LMT) atom optics. To this end, we have built a 10-meter scale atom drop tower, where we can perform proof-of-principle demonstrations of the proposed AGIS detector in an environment that permits more than 2.5 seconds of free-fall time. This facility allows for demonstration of atom interferometry with long interrogation time (seconds) and large atom wavepacket

Saif, Babak N.↗

Effect of Injector Geometry on Atomization of a Liquid-Liquid Double Swirl Coaxial Injector Using Non-invasive Laser, Optical and X-ray Techniques

The spray characteristics of a liquid-liquid double swirl coaxial injector were studied using non-invasive optical, laser, and X-ray diagnostics. A parametric study of injector exit geometry demonstrated that spray breakup time, breakup type and sheet stability could be controlled with exit geometry. Phase Doppler interferometry was used to characterize droplet statistics and non-dimensional droplet parameters over a range of inlet conditions and for various fluids allowing for a study on the role of specific fluid properties in atomization. Further, X-ray radiography allowed for investigation of sheet thickness and breakup length to be quantified for different recess exit diameters and inlet pressures. Finally, computed tomography scans revealed that the spray cone was distinctively non-uniform and comprised of several pockets of increased mass flux.

Radke, C. R.↗

Density-Based Optical Diagnostic Techniques at Nasa Langley Research Center

Several density-based optical diagnostic techniques under development for both ground test facilities and flight vehicles at NASA Langley Research Center will be presented. I will first discuss recent development work on focused laser differential interferometry (FLDI) for Langley’s hypersonic test facilities, including multi-point FLDI and co-linear FLDI/schlieren imaging. I will then discuss our work on tomographic background-oriented schlieren (Tomo BOS) and the challenges associated with its implementation in Langley’s ground test facilities. Finally, I will present results obtained with a new self-aligned focusing schlieren technique my team has developed and discuss how this technique is a significant improvement over traditional focusing schlieren systems.

Brett Bathel↗

Mark III very long baseline interferometry positions of eight stellar systems and astrometric comparisons

Accurate positions of eight stellar systems have been obtained from Mark III VLBI observations performed with multistation arrays, and the quality of the celestial frames used by different techniques is compared. The satisfactory agreement found between VLBI and optical positions indicates that the preliminary FK5 optical frame defined by Fricke (1982) is aligned with the VLBI extragalactic reference frame. The VLBI and VLA right ascensions agree, while a large discrepancy is noted between the VLBI and VLA declinations.

Lestrade, Jean-Francois↗

Short baseline phase delay interferometry

The high precision of the phase delay data type allows angular navigation accuracy on relatively short baselines to compete with the angular accuracy achieved with long baseline group delay measurements. Differential phase delay observations of close quasar pairs on both a 5.9-km baseline (DSS 12-DSS 13) and a 253-km baseline (DSS 13-Owens Valley Radio Observatory) have been performed to study the potential navigational precision and accuracy of the short baseline interferometry. As a first step toward demonstration of a connected element system at Goldstone, the DSS 12-DSS 13 baseline was operated coherently, distributing a common frequency reference via a recently installed fiber optic cable. The observed phase delay residuals of about 10 psec or less on both baselines appear to be dominated by short term troposphere fluctuations, and correspond to navigational accuracies of well below 50 nrad for the 253-km baseline. Additional experiments will be required to probe the full range of systematic errors.

Edwards, C. D.↗

Astrometry VLBI in Space (AVS

A proposed new space radio astronomy mission for astrometry is described. The Astrometry VLBI (very long baseline) in Space (AVS) nominal mission includes two identical spacecraft, each with a 4-m antenna sending data to a 70-m ground station. The goals of AVS are improving astrometry accuracy to the microarcsecond level and improving the accuracy of the transformation between the inertial radio and optical coordinate reference frames.

astrometry very long baseline interferometry VLBI↗