Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

The Disk Physical Conditions of 48 Persei Constrained by Contemporaneous Hα Spectroscopy and Interferometry

We utilize a multi-step modeling process to produce synthetic interferometric and spectroscopic observables, which are then compared to their observed counterparts. Our extensive set of interferometric observations of the Be star 48 Per, totaling 291 data points, were obtained at the Navy Precision Optical Interferometer from 2006 November 07 to 23. Our models were further constrained by comparison with contemporaneous Hα line spectroscopy obtained at the John S. Hall Telescope at the Lowell Observatory on 2006 November 1. Theoretical spectral energy distributions, SEDs, for 48 Per were confirmed by comparison with observations over a wavelength regime of 0.4–60 μm from Touhami et al. and Vieira et al. Our best-fitting combined model from Hα spectroscopy, Hα interferometry, and SED fitting has a power-law density fall off, n, of 2.3 and an initial density at the stellar surface of ρ{sub 0}=1.0×10{sup −11} g cm{sup −3} with an inclination constrained by Hα spectroscopy and interferometry of 45{sup ∘}±5{sup ∘}. The position angle for the system, measured east from north, is 114° ± 18°. Our best-fit model shows that the disk emission originates in a moderately large disk with a radius of 25 R {sub *}, which is consistent with a disk mass of approximately 5 × 10{sup 24} g or 3 × 10{sup −10} M {sub *}. Finally, we compare our results with previous studies of 48 Per by Quirrenbach et al. and find agreement, whereas our disk size does not agree with Delaa et al., based on a much smaller visibility set.

79 ASTRONOMY AND ASTROPHYSICS↗

Directionally asymmetric nonlinear optics in ferrorotational MnTiO 3

Ferrorotationally ordered materials possess a planar chiral lattice of electric dipoles that are a promising platform for exhibiting directionally asymmetric response functions. A key characteristic of such order is that enantiomorph conversion occurs when the solid is flipped by 180° about an in-plane axis. Using second-harmonic interferometry, we show here that when circularly polarized light is incident on MnTiO 3 , the generated harmonic intensity depends on whether the incident light is parallel or antiparallel to the ferrorotational axis. For a particular photon helicity, constructive interference occurs in one direction while destructive interference occurs in the other. Here, our observations represent a fundamentally new optical effect, associated with circularly polarized light in ferrorotational solids, that is distinct from conventional optical activity observed in three-dimensional chiral and Faraday media.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Early time studies of cylindrical liner implosions at 1 MA on COBRA

Tests of the magnetized liner inertial fusion (MagLIF) concept will make use of the 27 MA Z machine at Sandia National Laboratories, Albuquerque, to implode a cylindrical metal liner to compress and heat preheated, magnetized plasma contained within it. While most pulsed power machines produce much lower currents than the Z-machine, there are issues that can still be addressed on smaller scale facilities. Recent work on the Cornell Beam Research Accelerator (COBRA) has made use of 10 mm long and 4 mm diameter metal liners having different wall thicknesses to study the initiation of plasma on the liner’s surface as well as axial magnetic field compression [P.-A. Gourdain et al., Nucl. Fusion 53, 083006 (2013)]. This report presents experimental results with non-imploding liners, investigating the impact the liner’s surface structure has on initiation and ablation. Extreme ultraviolet (XUV) imaging and optical 12 frame camera imaging were used to observe and assess emission non-uniformities as they developed. Axial and side-on interferometry was used to determine the distribution of plasma near the liner surface, including the impact of non-uniformities during the plasma initiation and ablation phases of the experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monolithic Spatial Heterodyne Raman Spectrometers (mSHRS): Toward highly miniature chemical sensors for deployment on moving platforms (Final Report, Phase I)

This report covers phase 1 (year 1) of the mSHRS project. Our ultimate long-term goal is to develop highly miniature Raman analyzers, known as spatial heterodyne Raman spectrometers (SHRS), that are deployable as in-situ chemical sensors on moving platforms. During Phase I (FY19/20) funding, our team focused our efforts solely on the key innovation needed toward realizing that goal: the development of the monolithic interferometer comprising the beam splitter and gratings with the appropriate design parameters and tolerances to enable Raman interferometry. We successfully developed and characterized the performance of the first monolithic SHRS devices including a monolithic version that incorporates field-widened optics. Our solid-state design approach integrated all optical components as a single monolithic unit for maintaining precise optical alignment during sensor operation, a requirement for operating in a vibration prone environment. This project has two principle activities: (1) Design and fabricate monolithic SHRS devices (i.e. monolithic device task) and (2) characterize the mSHRS devices in terms of performance (i.e. the Monolithic SHRS characterization task).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Semiconductor point defect concentration profiles measured using coherent acoustic phonon waves

Coherent acoustic phonon interferometry is used to quantitatively measure depth-dependent point defect concentrations in semiconductor systems with a depth range of the order of tens of microns. Using time-resolved pump-probe techniques, the optical response of ion-beam irradiated GaAs crystals is analyzed as a function of defect concentration ranging over four orders of magnitude. Varying the ion dose quantitatively relates changes in the optical response to local defect concentrations. Thermal annealing is shown to reduce the effect on the optical response, indicating recovery of the crystal lattice through self-interstitial-vacancy recombination.

36 MATERIALS SCIENCE↗

Assessment of the grindability of robocast silicon carbide

The demand for high-performance lightweight optics has driven interest in silicon carbide (SiC) due to its exceptional thermal stability, hardness, and strength-to-weight ratio. This study investigates the potential of robocasting, an additive manufacturing process, as a viable method for producing lightweighted SiC components for optical applications. Four samples with varied starting powder phases (α and β) and sintering conditions were fabricated and evaluated. Post-sintering surface and form were assessed using coherence scanning interferometry (CSI) and coordinate measuring machine (CMM) techniques. A three-stage grinding process was applied to each sample, with surface roughness assessed at each stage. Results demonstrate that samples with predominantly α-phase SiC and smaller particle sizes achieved superior surface finish, particularly sample D2-α-2135 °C, which displayed the lowest post-grinding Sq value of 0.178 µm. The analysis also indicated no significant print-through effect from the lightweighting structure, or print artifacts, at this stage of grinding. However, β-phase samples showed poorer grindability, increased surface roughness, and pitting. These findings suggest that phase composition and particle size are critical for achieving the desired surface quality in robocast SiC optics. Future work will incorporate additional samples and finer grinding wheels to refine surface quality further, supporting the development of SiC for high-precision optical applications.

Barrett, Taylor [ORNL]↗

Atom chip apparatus for experiments with ultracold rubidium and potassium gases

We present a dual chamber atom chip apparatus for generating ultracold {sup 87}Rb and {sup 39}K atomic gases. The apparatus produces quasi-pure Bose-Einstein condensates of 10{sup 4} {sup 87}Rb atoms in an atom chip trap that features a dimple and good optical access. We have also demonstrated production of ultracold {sup 39}K and subsequent loading into the chip trap. We describe the details of the dual chamber vacuum system, the cooling lasers, the magnetic trap, the multicoil magnetic transport system, the atom chip, and two optical dipole traps. Due in part to the use of light-induced atom desorption, the laser cooling chamber features a sufficiently good vacuum to also support optical dipole trap-based experiments. The apparatus is well suited for studies of atom-surface forces, quantum pumping and transport experiments, atom interferometry, novel chip-based traps, and studies of one-dimensional many-body systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

The bound coherent neutron scattering length of the oxygen isotopes

The technique of neutron interferometry was used to measure the bound coherent neutron scattering length bcoh of the oxygen isotopes 17O and 18O. From the measured difference in optical path between two water samples, either H2 17O or H2 18O versus H2 natO, where nat denotes the natural isotopic composition, we obtain bcoh , 17O = 5.867(4) fm and bcoh , 18O = 6.009(5) fm, based on the accurately known value of bcoh , natO = 5.805(4) fm which is equal to bcoh , 16O within the experimental uncertainty. Our results for bcoh , 17O and bcoh , 18O differ appreciably from the standard tabulated values of 5.6(5) fm and 5.84(7) fm, respectively. In particular, our measured scattering length contrast of 0.204(3) fm between 18O and natO is nearly a factor of 6 greater than the tabulated value, which renders feasible neutron diffraction experiments using 18O isotope substitution and thereby offers new possibilites for measuring the partial structure factors of oxygen-containing compounds, such as water.

Fischer, Henry E↗

Role of pump coherence in two-photon interferometry

We use a parametric down-conversion source pumped by a short-coherence-length continuous-wave (CW) diode laser to perform two-photon interferometry in an intermediate regime between the more familiar Franson-type experiments with a long-coherence-length pump laser, and the short pulsed pump ''time-bin'' experiments pioneered by Gisin's group. The use of a time-bin-like Mach-Zehnder interferometer in the CW pumping beam induces coherence between certain two-photon amplitudes, while the CW nature of the experiment prevents the elimination of remaining incoherent ones. The experimental results highlight the role of pump coherence in two-photon interferometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-accuracy Aspheric X-ray Mirror Metrology Using Software Configurable Optical Test System/deflectometry

The Software Configurable Optical Test System (SCOTS) uses deflectometry to measure surface slopes of general optical shapes without the need for additional null optics. Careful alignment of test geometry and calibration of inherent system error improve the accuracy of SCOTS to a level where it competes with interferometry. We report a SCOTS surface measurement of an off-axis superpolished elliptical x-ray mirror that achieves <1 nm<1 nm root-mean-square accuracy for the surface measurement with low-order term included.

42 ENGINEERING↗

Decoherence-free neutron interferometry

Perfect single-crystal neutron interferometers are adversely sensitive to environmental disturbances, particularly mechanical vibrations. The sensitivity to vibrations results from the slow velocity of thermal neutrons and the long measurement time that are encountered in a typical experiment. Consequently, to achieve a good interference solutions for reducing vibration other than those normally used in optical experiments must be explored. Here we introduce a geometry for a neutron interferometer that is less sensitive to low-frequency vibrations. This design may be compared with both dynamical decoupling methods and decoherence-free subspaces that are described in quantum information processing. By removing the need for bulky vibration isolation setups, this design will make it easier to adopt neutron interferometry to a wide range of applications and increase its sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray Irradiance Distribution for an Interferometer with a Curved Biprism Array

The development of interferometry-based X-ray phase contrast imaging systems that provide highly resolved X-rays with spatially-modulated intensity is enabling the full potential of X-ray optics to image phase, attenuation, and small angle scatter properties of soft tissue. In this work we present analytical formulations of a new hardware concept for X-ray phase contrast imaging wherein the phase grating is replaced with an array of Fresnel biprisms. We derive expressions for the irradiance distribution pattern of a biprism interferometer composed of a curved biprism array with multiple biprisms and multiple point sources. These expressions are used to plot fringe patterns for X-ray design parameters, including 1) size, number, and period of X-ray point sources; 2) biprism parameters of material composition, angle, number, and period; and 3) biprism array to X-ray source and detector distances. Analytical results show that the biprism interferometer provides a longitudinally-nonperiodic pattern of spatially modulated intensity different from the Talbot longitudinally-periodic pattern common in grating interferometry. The curvature of the biprism array brings a sharper longitudinal fringe pattern. Experiments are being performed to verify the analytical calculations for a biprism plastic material of SU-8 using a synchrotron source. X-ray biprism material has widely varied indexes of refraction relative to wavelength and thus the separation of the virtual sources and resulting interference fringe period also varies with X-ray wavelength. Our aim is to develop biprism interferometry imaging systems with excellent polychromatic performance that produce high-contrast fringes with spatially incoherent X-ray illumination. Biprism interferometry will potentially provide higher fringe visibility with better image quality to that of diffraction grating interferometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prism-pair interferometry by homodyne interferometers with a common light source for high-accuracy measurement of the absolute refractive index of glasses

A prism-pair interferometer comprising two homodyne interferometers with a common light source was developed for high-precision measurements of the refractive index of optical glasses with an uncertainty of the order of 10{sup -6}. The two interferometers measure changes in the optical path length in the glass sample and in air, respectively. Uncertainties in the absolute wavelength of the common light source are cancelled out by calculating a ratio between the results from the interferometers. Uncertainties in phase measurement are suppressed by a quadrature detection system. The combined standard uncertainty of the developed system is evaluated as 1.1x10{sup -6}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Conceptual design of the tangentially viewing combined interferometer-polarimeter for ITER density measurements

One of the systems planned for the measurement of electron density in ITER is a multi-channel tangentially viewing combined interferometer-polarimeter (TIP). This work discusses the current status of the design, including a preliminary optical table layout, calibration options, error sources, and performance projections based on a CO{sub 2}/CO laser system. In the current design, two-color interferometry is carried out at 10.59 {mu}m and 5.42 {mu}m and a separate polarimetry measurement of the plasma induced Faraday effect, utilizing the rotating wave technique, is made at 10.59 {mu}m. The inclusion of polarimetry provides an independent measure of the electron density and can also be used to correct the conventional two-color interferometer for fringe skips at all densities, up to and beyond the Greenwald limit. The system features five chords with independent first mirrors to reduce risks associated with deposition, erosion, etc., and a common first wall hole to minimize penetration sizes. Simulations of performance for a projected ITER baseline discharge show the diagnostic will function as well as, or better than, comparable existing systems for feedback density control. Calculations also show that finite temperature effects will be significant in ITER even for moderate temperature plasmas and can lead to a significant underestimate of electron density. A secondary role TIP will fulfill is that of a density fluctuation diagnostic; using a toroidal Alfven eigenmode as an example, simulations show TIP will be extremely robust in this capacity and potentially able to resolve coherent mode fluctuations with perturbed densities as low as {delta}n/n Almost-Equal-To 10{sup -5}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dispersion Leverage Coronagraph: a nulling coronagraph for use on primary objective grating telescopes

Here, we present the Dispersion Leverage Coronagraph (DLC), a variation of the Achromatic Interfero Coronagraph (AIC) that is designed for optical systems featuring large, dispersive primary objective gratings. DLC was originally designed for the Diffractive Interfero Coronagraph Exoplanet Resolver (DICER), a notional 20 m class infrared space telescope utilizing the enhanced one-dimensional angular resolution of large diffraction gratings to discover and characterize near-Earth exoplanets. Here we develop the theoretical foundation for DLC, and apply it to DICER as an example use case. We derive important properties of the DLC system, including focal plane transmission maps, stellar leakage, residual optical path difference tolerance, and pointing error/jitter considerations. Ultimately, we found that DLC effectively nulls an on-axis target across the entire spectrum in the focal plane, allowing for 2D/λ diffraction-limited imaging. It requires asymmetrical fine-guidance tolerances on pointing error/jitter. We work through a benchmark DICER design, explaining the need for a second disperser to reduce background from Zodiacal light, and showing that it could plausibly find and characterize ∼4 nearby, habitable exoplanets around Sun-like stars in a 7-year mission; about 30% of the habitable exoplanets within 8 pc were found in our simulation. The DLC may be useful for any application requiring extremely high-resolution, close companion spectroscopy.

AIC↗

High temperature dilatation measurements by in situ laser interferometry under high magnetic field

This article contains a description of a laser interferometer coupled with a furnace for in situ dilatation measurements under high magnetic field. The apparatus fits an 18 T superconducting magnet with a 32 mm diameter room temperature bore. This optical method was chosen for dilatation measurements because it is not perturbated by the magnetic field. The measured sample can be heated up to 1500 K under a controlled atmosphere, and heating and cooling rates can be varied within a range of 10 K/s. The resolution is below 50 nm. As an example of using in situ dilatation measurements to follow phase transformations, the increase in the ferrite/austenite transformation temperature in pure iron in a magnetic field up to 16 T was experimentally evidenced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast temporal phase-resolved nonlinear optical spectroscopy in the molecular frame

In an ultrafast nonlinear optical interaction, the electric field of the emitted nonlinear signal provides direct access to the induced nonlinear transient polarization or transient currents and thus carries signatures of ultrafast dynamics in a medium. Measurement of the electric field of such signals offers sensitive observables to track ultrafast electron dynamics in various systems. In this work, we resolve the real-time phase of the electric field of a femtosecond third-order nonlinear optical signal in the molecular frame. The electric field emitted from impulsively pre-aligned gas-phase molecules at room temperature, in a degenerate four-wave mixing scheme, is measured using a spectral interferometry technique. The nonlinear signal is measured around a rotational revival to extract its molecular-frame angle dependence from pump-probe time-delay scans. By comparing these measurements for two linear molecules, carbon dioxide and nitrogen, we show that the measured second-order phase parameter (temporal chirp) of the signal is sensitive to the valence electronic symmetry of the molecules, whereas the amplitude of the signal does not show such sensitivity. We compare measurements to theoretical calculations of the chirp observable in the molecular frame. This work is an important step towards using electric field measurements in nonlinear optical spectroscopy to study ultrafast dynamics of electronically excited molecules in the molecular frame.

47 OTHER INSTRUMENTATION↗

Plasma and radiation detection via fiber interferometry

Photonic Doppler velocimetry tracks motion during high-speed, single-event experiments using telecommunication fiber components. The same technology can be applied in situations where there is no actual motion, but rather a change in the optical path length. Migration of plasma into vacuum alters the refractive index near a fiber probe, while intense radiation modifies the refractive index of the fiber itself. Lastly, these changes can diagnose extreme environments in a flexible, time-resolved manner.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗