Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE ANGLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Calculating frequency at loads in simulations of electro-mechanical transients

This paper introduces a new method for calculating frequency at an electrical load in simulations of electro-mechanical transients. The method is designed for simulation studies that require accurate models of sensors such as phasor measurement units and F-Net devices, which measure frequency at locations away from generating plants. These sensors are poised to become critical components in the control systems of electrical power grids, and therefore simulation tools that incorporate accurate models of these devices are essential. The method proposed here corrects two drawbacks of using numerically computed phase angle derivatives to approximate frequency. First, it eliminates spurious spikes in frequencies calculated at loads. Second, it eliminates instabilities induced by the simulator in studies of frequency responsive loads. The proposed method is derived from a simplified model of the generators and loads in an electrical system, but in the final analysis does not depend critically on these simplifications and is therefore applicable to more sophisticated models. The method is demonstrated with the simplified model applied to the IEEE 14 and 300 bus systems.

42 ENGINEERING↗

Survivability of Autonomous Microgrid during Overload Events

Grid-forming sources are voltage sources that draw necessary currents to meet any load changes. A load step can cause part or all of these sources to become overloaded in a microgrid. This paper presents an overload mitigation controller that addresses the two overload issues in a microgrid by actively controlling the sources’ frequency. When part of the sources in a microgrid is overloaded, the controller autonomously transfers the extra load to other sources by rapidly reducing its frequency. The frequency difference between sources during transient results in a change of phase angle, which redistributes the power flow. When all sources in a microgrid are overloaded, each source keeps dropping the frequency. Therefore, under frequency load shedding can be used to trip the non-critical loads resulting in the survival of microgrid. The advantages of these concepts are that communications between sources are not needed during transient, and the robust voltage control is maintained. Lastly, simulation and field tests from CERTS/AEP microgrid test site verify that the control strategy is effective in both purely inverter-based microgrids and inverter & generator mixed microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Two-Stage Kalman Filter Approach for Robust and Real-Time Power System State Estimation

As electricity demand continues to grow and renewable energy increases its penetration in the power grid, realtime state estimation becomes essential for system monitoring and control. Recent development in phasor technology makes it possible with high-speed time-synchronized data provided by Phasor Measurement Units (PMU). In this paper we present a two-stage Kalman filter approach to estimate the static state of voltage magnitudes and phase angles, as well as the dynamic state of generator rotor angles and speeds. Kalman filters achieve optimal performance only when the system noise characteristics have known statistical properties (zero-mean, Gaussian, and spectrally white). However in practice the process and measurement noise models are usually difficult to obtain. Thus we have developed the Adaptive Kalman Filter with Inflatable Noise Variances (AKF with InNoVa), an algorithm that can efficiently identify and reduce the impact of incorrect system modeling and/or erroneous measurements. In stage one, we estimate the static state from raw PMU measurements using the AKF with InNoVa; then in stage two, the estimated static state is fed into an extended Kalman filter to estimate the dynamic state. Simulations demonstrate its robustness to sudden changes of system dynamics and erroneous measurements.

Zhang, Jinghe↗

Unique Method for Generating Design Earthquake Time History Seeds

A method has been developed which takes a single seed earthquake time history and produces multiple similar seed earthquake time histories. These new time histories possess important frequency and cumulative energy attributes of the original while having a correlation less than 30% (per the ASCE/SEI 43-05 Section 2.4 [1]). They are produced by taking the fast Fourier transform of the original seed. The averaged amplitudes are then pared with random phase angles and the inverse fast Fourier transform is taken to produce a new time history. The average amplitude through time is then adjusted to encourage a similar cumulative energy curve. Next, the displacement is modified to approximate the original curve using Fourier techniques. Finally, the correlation is checked to ensure it is less than 30%. This process does not guarantee that the correlation will be less than 30% for all of a given set of new curves. It does provide a simple tool where a few additional iterations of the process should produce a set of seed earthquake time histories meeting the correlation criteria.

42 ENGINEERING↗

Voltage waveform tailoring for high aspect ratio plasma etching of SiO 2 using Ar/CF 4 /O 2 mixtures: Consequences of ion and electron distributions on etch profiles

The quality of high aspect ratio (HAR) features etched into dielectrics for microelectronics fabrication using halogen containing low temperature plasmas strongly depends on the energy and angular distribution of the incident ions (IEAD) onto the wafer, as well as potentially that of the electrons (EEAD). Positive ions, accelerated to high energies by the sheath electric field, have narrow angular spreads and can penetrate deeply into HAR features. Electrons typically arrive at the wafer with nearly thermal energy and isotropic angular distributions and so do not directly penetrate deeply into features. These differences can lead to positive charging of the insides of the features that can slow etching rates and produce geometric defects such as twisting. In this work, we computationally investigated the plasma etching of HAR features into SiO 2 using tailored voltage waveforms in a geometrically asymmetric capacitively coupled plasma sustained in an Ar/CF 4 /O 2 mixture at 40 mTorr. The tailored waveform consisted of a sinusoidal wave and its higher harmonics with a fundamental frequency of 1 MHz. We found that some degree of control of the IEADs and EEADs is possible by adjusting the phase of higher harmonics φ through the resulting generation of electrical asymmetry and electric field reversal. However, the IEADs and EEADs cannot easily be separately controlled. The control of IEADs and EEADs is inherently linked. The highest quality feature was obtained with a phase angle φ = 0° as this value generated the largest (most negative) DC self-bias and largest electric field reversal for accelerating electrons into the feature. That said, the consequences of voltage waveform tailoring (VWT) on etched features are dominated by the change in the IEADs. Although VWT does produce EEADs with higher energy and narrower angular spread, the effect of these electrons on the feature compared to thermal electrons is not large. Finally, this smaller impact of VWT produced EEADs is attributed to thermal electrons being accelerated into the feature by electric fields produced by the positive in-feature charging.

47 OTHER INSTRUMENTATION↗

Rheological diagnostic tools for state transitions

Thermodynamic or kinetic state transitions of six polymeric systems were probed using rheology in isothermal and nonisothermal isochronal experiments. The polymeric systems were representative of three different types of transitions: Gelation, macrophase separation, and order-disorder transitions. A phenomenological dimensionless parameter termed the relative elasticity, R, was found to be particularly sensitive to these transitions and was finitely bound by the viscous limit and the elastic limit with values of zero and one, respectively. In addition, the (time or temperature) derivative of R and tan δ (with δ being the phase angle) proved to be more sensitive to transitions as compared to the respective pure values. When compared to other methods found in literature, these new phenomenological protocols are found to be robust while providing a convenient and precise means of detecting transitions. Hence, they may complement existing methods, whereas they are beneficial to industrial or other systems exhibiting multiple transitions due to their high sensitivity.

42 ENGINEERING↗

Detecting trihalomethanes using nanoporous-carbon coated surface-acoustic-wave sensors

We study nanoporous-carbon (NPC) grown via pulsed laser deposition (PLD) as a sorbent coating on 96.5-MHz surface-acoustic-wave (SAW) devices to detect trihalomethanes (THMs), regulated byproducts from the chemical treatment of drinking water. Using both insertion-loss and isothermal-response measurements from known quantities of chloroform, the highest vapor pressure THM, we optimize the NPC mass-density at 1.05 ± 0.08 g/cm3 by controlling the background argon pressure during PLD. Precise THM quantities in a chlorobenzene solvent are directly injected into a separation column and detected as the phase-angle shift of the SAW device output compared to the drive signal. Using optimized NPC-coated SAWs, we study the chloroform response as a function of operating temperatures ranging from 10–50°C. Finally, we demonstrate individual responses from complex mixtures of all four THMs, with masses ranging from 10–2000 ng, after gas chromatography separation. As a result, estimates for each THM detection limit using a simple peak-height response evaluation are 4.4 ng for chloroform and 1 ng for bromoform; using an integrated-peak area response analysis improves the detection limits to 0.73 ng for chloroform and 0.003 ng bromoform.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A stochastic electricity market clearing formulation with consistent pricing properties

We argue that deterministic market clearing formulations introduce arbitrary distortions between day-ahead and expected real-time prices that bias economic incentives. We extend and analyze a previously proposed stochastic clearing formulation in which the social surplus function induces penalties between day-ahead and real-time quantities. We prove that the formulation yields price bounded price distortions, and we show that adding a similar penalty term to transmission flows and phase angles ensures boundedness throughout the network. We prove that when the price distortions are zero, day-ahead quantities equal a quantile of their real-time counterparts. The undesired effects of price distortions suggest that stochastic settings provide significant benefits over deterministic ones that go beyond social surplus improvements. Finally, we propose additional metrics to evaluate these benefits.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Volume and surface area of a spherical harmonic surface approximation to a NIF implosion core defined by HGXI/GXD images from the equator and pole

A solid object, such as a simplified approximation to an implosion core defined by the 17% intensity contour, can be described by a sum of spherical harmonics, following the notation of Butkov (Mathematical Physics, ISBN 0-201-00727-4, 1968; there are other notations so care is required), with Pl(x) being the usual (apparently standard) Legendre polynomial. For the present purposes, finding the volume and surface area of an implosion core defined by P0, P2, P4, M0, and M4, I will restrict the problem to consider only A 00 , A 20 , A 40 , and A 44 , with the phase angle set to eliminate the sin(mΦ) term. Once the volume and surface area are determined, I will explore how these coefficients relate to measured quantities A0, A2/A0, A4/A0, M0, and M4/M0.

36 MATERIALS SCIENCE↗

Demonstration of a Novel Synchrophasor-based Situational Awareness System: Wide Area Power System Visualization, On-line Event Replay and Early Warning of Grid Problems

Since the large North Eastern power system blackout on August 14, 2003, U.S. electric utilities have spent lot of effort on preventing power system cascading outages. Two of the main causes of the August 14, 2003 blackout were inadequate situational awareness and inadequate operator training In addition to the enhancements of the infrastructure of the interconnected power systems, more research and development of advanced power system applications are required for improving the wide-area security monitoring, operation and planning in order to prevent large- scale cascading outages of interconnected power systems. It is critically important for improving the wide-area situation awareness of the operators or operational engineers and regional reliability coordinators of large interconnected systems. With the installation of large number of phasor measurement units (PMU) and the related communication infrastructure, it will be possible to improve the operators’ situation awareness and to quickly identify the sequence of events during a large system disturbance for the post-event analysis using the real-time or historical synchrophasor data. The purpose of this project was to develop and demonstrate a novel synchrophasor-based comprehensive situational awareness system for control centers of power transmission systems. The developed system named WASA (Wide Area Situation Awareness) is intended to improve situational awareness at control centers of the power system operators and regional reliability coordinators. It consists of following main software modules: • Wide-area visualizations of real-time frequency, voltage, and phase angle measurements and their contour displays for security monitoring. • Online detection and location of a major event (location, time, size, and type, such as generator or line outage). • Near-real-time event replay (in seconds) after a major event occurs. • Early warning of potential wide-area stability problems. The system has been deployed and demonstrated at the Tennessee Valley Authority (TVA) and ISO New England system using real-time synchrophasor data from openPDC. Apart from the software product, the outcome of this project consists of a set of technical reports and papers describing the mathematical foundations and computational approaches of different tools and modules, implementation issues and considerations, lessons learned, and the results of lidation processes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Measurement Error on Synchrophasor Applications

Phasor measurement units (PMUs), a type of synchrophasor, are powerful diagnostic tools that can help avert catastrophic failures in the power grid. Because of this, PMU measurement errors are particularly worrisome. This report examines the internal and external factors contributing to PMU phase angle and frequency measurement errors and gives a reasonable explanation for them. It also analyzes the impact of those measurement errors on several synchrophasor applications: event location detection, oscillation detection, islanding detection, and dynamic line rating. The primary finding is that dynamic line rating is more likely to be influenced by measurement error. Other findings include the possibility of reporting nonoscillatory activity as an oscillation as the result of error, failing to detect oscillations submerged by error, and the unlikely impact of error on event location and islanding detection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Processing Package for Cyclic Integrated Reversible Bending Fatigue Testing

A data processing software package has been introduced. The package was developed using MATLAB with the aid of the Curve Fitting Toolbox. The package is made up of four modules: pre-processing, data processing for static testing, data processing for monitoring, and data processing for measurements. CIRFT data are structured with multiple levels of architecture involving group, specimen, session, and scan/block. The degree of complexity of the data structure depends on whether a test is static or cyclic.The test results are presented in figures, scatter plots, and tables. For static testing, the output in tables provides bending mechanical properties and characteristic points of moment–curvature relation: flexural rigidities in linear segments of loading and unloading stages, intersection points between characteristic segments of the curve, and equivalent stress and strain quantities. For cyclic testing, the table output lists control and fatigue life and responsive/dependent quantities including moment, curvature, flexural rigidity, flexural hysteresis, rigidity phase angle, and equivalent stresses and strains. In addition, derivatives such as half-gage length and sensor spacing correction are included. The output also provides standard deviations of the reported quantities when they are applicable or available. The data processing package can serve as a fundamental characterization tool in mechanical study of materials. The package is intended primarily for data processing for the CIRFT process and can also be used in applications for which similar testing requirements exist.

36 MATERIALS SCIENCE↗

TCF-20-20213: Advanced Power Distribution Sensing and Communications through the Cable TV Broadband Network (Final Report. Period of Performance: June 2020 to June 2022)

To enable the rapid, widespread commercial availability of secondary distribution grid voltage and phase angle data, the DOE OE Technology Commercialization Fund (TCF) project: 1) created a new American National Standard for next-generation grid power quality sensing and communications, 2) created a new prototype broadband-based standard-compliant grid power sensing system for use by utilities and others, and 3) improved by several orders of magnitude the spatiotemporal scale of the in-progress DOE CESER project: Situational Awareness of Grid Anomalies (SAGA) for Visual Analytics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DOE SCGSR Final Report - Project Accomplishments and Additional Materials

The major accomplishments of my project were successfully developing and testing the laser interferometry diagnostic on the Plasma Liner Experiment (PLX) at Los Alamos National Laboratory (LANL). This diagnostic helped advance my research by providing a simpler way to obtain electron density measurements of magnetized plasmas compared to other electron density diagnostics such as triple Langmuir probes. The laser used was a 561 nm continuous wave (CW) diode-pumped solid state (DPSS) laser. The PLX laser interferometry diagnostic consists of two parts. These include the launching and receiving sides of the laser diagnostic. The launching side consists of the main laser beam from the DPSS laser being split into five chords(probe beams) and a reference beam which are then directed with fiber optic couplers into fiber optic cables which transmit the probe beamsto the PLX vacuum chamber. The probe beams then pass through the plasma in the chamber and into the receiving side optics where they are again directed through fiber optic cables to be combined with the reference beam. The combined beams are transmitted via multi-mode fiber optic cables to photodiodes to convert the light signals into electrical signals. Before the electrical signals get digitized, they pass through bandpass and low pass filters to eliminate electromagnetic noise and unwanted frequencies. The electrical signals are then processed by IQ demodulators to determine phase angle difference between the probe and reference beams for each chord in order to calculate line-integrated electron density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Subcritical Neutron and Gamma Noise Measurements at the Seven Percent Critical Experiment (7uPCX) [Slides]

Post measurement synchronization of noise signals allowed for the investigation of previously unseen correlations. Noise of gamma, thermal and fast neutron signals performed similarly in estimating the prompt neutron decay constant at various subcritical states. The CPSD amplitude terms displayed different magnitudes. The neutron-based amplitudes suffered more from changes in detector efficiency as the number of fuel rods in the system increased. The time lag between 3 He tubes is observable using the CPSD phase angle and agreed with a simplified diffusion estimation.

3He detectors↗

Study of the Protection Improvements for a Weak Grid Area With High Inverter-Based Resources (IBRs)

This project designs enhanced protection scheme for the real-world weak grid area with a high penetration of IBRs. As the existing protection schemes are originally designed for traditional synchronous machines, we first evaluate if the protection scheme will continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with IBR original equipment manufacturer black-box models is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. Enhanced protection is designed to address the challenge of lack of negative sequence current from IBRs, including increased restraining factors a2 and k2 to block 32Q or using V instead QV ORDER for ground faults, enhanced mho distance element with voltage and phase angle supervision for L-L faults. The efficacy of enhanced protection logic is validated and proven to work reliably. Additionally, IEEE Std. 2800-2022 negative sequence current compliant GFL and GFM IBRs from another vendor are tested and proven to work reliably without need for enhanced logic. Therefore, this work provides valuable decision-making for utilities facing protection system challenges due to IBRs, either designing enhanced protection scheme or requesting their IBRs being IEEE Std. 2800-2022 compliant to produce regulated negative sequence current for protection relay to make correct decision.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrochemical NOx Sensor for Monitoring Diesel Emissions

Increasingly stringent emissions regulations will require the development of advanced gas sensors for a variety of applications. For example, compact, inexpensive sensors are needed for detection of regulated pollutants, including hydrocarbons (HCs), CO, and NO{sub x}, in automotive exhaust. Of particular importance will be a sensor for NO{sub x} to ensure the proper operation of the catalyst system in the next generation of diesel (CIDI) automobiles. Because many emerging applications, particularly monitoring of automotive exhaust, involve operation in harsh, high-temperature environments, robust ceramic-oxide-based electrochemical sensors are a promising technology. Sensors using yttria-stabilized zirconia (YSZ) as an oxygen-ion-conducting electrolyte have been widely reported for both amperometric and potentiometric modes of operation. These include the well-known exhaust gas oxygen (EGO) sensor. More recently, ac impedance-based (i.e., impedance-metric) sensing techniques using YSZ have been reported for sensing water vapor, hydrocarbons, CO, and NO{sub x}. Typically small-amplitude alternating signal is applied, and the sensor response is measured at a specified frequency. Most impedance-metric techniques have used the modulus (or magnitude) at low frequencies (< 1 Hz) as the sensing signal and attribute the measured response to interfacial phenomena. Work by our group has also investigated using phase angle as the sensing signal at somewhat higher frequencies (10 Hz). The higher frequency measurements would potentially allow for reduced sampling times during sensor operation. Another potential advantage of impedance-metric NO{sub x} sensing is the similarity in response to NO and NO{sub 2} (i.e., total-NO{sub x} sensing). Potentiometric NO{sub x} sensors typically show higher sensitivity to NO2 than NO, and responses that are opposite in sign. However, NO is more stable than NO{sub 2} at temperatures > 600 C, and thermodynamic calculations predict {approx}90% NO, balance NO{sub 2}. Since automotive exhaust sensors will probably be required to operate at temperatures > 600 C, NO is the dominant component in thermodynamic equilibrium and the target NOx species. Also, the use of upstream catalysts could further promote the conversion of NO{sub x} species to NO. Therefore, the focus of current work is to investigate the response to NO. Nevertheless, minimizing the sensitivity to a variety of competing species is important in order to obtain the accuracy necessary for achieving the emission limits. Mitigating the effect of interfering gases (e.g., O{sub 2}, water vapor, HCs, etc.) is an area of current study. For impedance metric NO{sub x} sensors, our previous work has demonstrated that the cross-sensitivity to O{sub 2} may be accounted for by comparing measurements at multiple frequencies. Other strategies for compensation are also being explored, including calibration using data from existing sensors located nearby. Our current work has made significant advances in terms of developing prototype sensors more suitable for commercialization. Also, dynamometer testing has provided real-world sensor performance data that will be useful in approaching potential suppliers to whom we can transfer the technology for commercialization. The advances are a direct result of understanding the sensing mechanisms responsible for impedance-based NO{sub x} sensing and the effect of materials choice and sensor design/geometry.

36 MATERIALS SCIENCE↗

Influence of Insulation Level on Electric Power Quality and Transformation Efficiency of Grid-Connected Photovoltaic Power Plants

The paper considers the influence of the insolation level on the electric power quality indicators and efficiency of a grid-tie inverter operating as part of a grid-connected photovoltaic power plant. Over the course of a year, data were recorded for Moscow on incoming solar radiation and the grid-tie inverter input and output capacity provided by a 1 kW grid-connected photovoltaic power plant. The insolation threshold values for a Solar River 1100 TL inverter are experimentally established, corresponding to both the beginning and end of stable inverter operation, as well as the required phase angle value for the electric energy supplied to the grid.

14 SOLAR ENERGY↗