At least 559 records · Page 31

Reynolds-Averaged Navier-Stokes Solutions to Flat Plate Film Cooling Scenarios

The predictions of several Reynolds-Averaged Navier-Stokes solutions for a baseline film cooling geometry are analyzed and compared with experimental data. The Fluent finite volume code was used to perform the computations with the realizable k-epsilon turbulence model. The film hole was angled at 35 to the crossflow with a Reynolds number of 17,400. Multiple length-to-diameter ratios (1.75 and 3.5) as well as momentum flux ratios (0.125 and 0.5) were simulated with various domains, boundary conditions, and grid refinements. The coolant to mainstream density ratio was maintained at 2.0 for all scenarios. Computational domain and boundary condition variations show the ability to reduce the computational cost as compared to previous studies. A number of grid refinement and coarsening variations are compared for further insights into the reduction of computational cost. Liberal refinement in the near hole region is valuable, especially for higher momentum jets that tend to lift-off and create a recirculating flow. A lack of proper refinement in the near hole region can severely diminish the accuracy of the solution, even in the far region. The effects of momentum ratio and hole length-to-diameter ratio are also discussed.

Johnson, Perry L.↗

Development of the Glenn Heat-Transfer (Glenn-HT) Computer Code to Enable Time-Filtered Navier-Stokes (TFNS) Simulations and Application to Film Cooling on a Flat Plate Through Long Cooling Tubes

Computational fluid dynamics (CFD) analysis using Reynolds-averaged Navier-Stokes (RANS) formulation for turbomachinery-related flows has enabled improved engine component designs. RANS methodology has limitations that are related to its inability to accurately describe the spectrum of flow phenomena encountered in engines. Examples of flows that are difficult to compute accurately with RANS include phenomena such as laminar/turbulent transition, turbulent mixing due to mixing of streams, and separated flows. Large eddy simulation (LES) can improve accuracy but at a considerably higher cost. In recent years, hybrid schemes that take advantage of both unsteady RANS and LES have been proposed. This study investigated an alternative scheme, the time-filtered Navier-Stokes (TFNS) method applied to compressible flows. The method developed by Shih and Liu was implemented in the Glenn-Heat-Transfer (Glenn-HT) code and applied to film-cooling flows. In this report the method and its implementation is briefly described. The film effectiveness results obtained for film cooling from a row of 30deg holes with a pitch of 3.0 diameters emitting air at a nominal density ratio of unity and two blowing ratios of 0.5 and 1.0 are shown. Flow features under those conditions are also described.

Ameri, Ali↗

Computational Fluid Dynamics Uncertainty Analysis Applied to Heat Transfer over a Flat Plate

There have been few discussions on using Computational Fluid Dynamics (CFD) without experimental validation. Pairing experimental data, uncertainty analysis, and analytical predictions provides a comprehensive approach to verification and is the current state of the art. With pressed budgets, collecting experimental data is rare or non-existent. This paper investigates and proposes a method to perform CFD uncertainty analysis only from computational data. The method uses current CFD uncertainty techniques coupled with the Student-T distribution to predict the heat transfer coefficient over a at plate. The inputs to the CFD model are varied from a specified tolerance or bias error and the difference in the results are used to estimate the uncertainty. The variation in each input is ranked from least to greatest to determine the order of importance. The results are compared to heat transfer correlations and conclusions drawn about the feasibility of using CFD without experimental data. The results provide a tactic to analytically estimate the uncertainty in a CFD model when experimental data is unavailable

Computational↗

Development of the Glenn-HT Computer Code to Enable Time-Filtered Navier-Stokes (TFNS) Simulations and Application to Film Cooling on a Flat Plate Through Long Cooling Tubes

Computational fluid dynamics (CFD) analysis using Reynolds-averaged Navier-Stokes (RANS) formulation for turbomachinery-related flows has enabled improved engine component designs. RANS methodology has limitations which are related to its inability to accurately describe the spectrum of flow phenomena encountered in engines. Examples of flows that are difficult to compute accurately with RANS include phenomena such as laminarturbulent transition, turbulent mixing due to mixing of streams, and separated flows. Large eddy simulation (LES) can improve accuracy but at a considerably higher cost. In recent years, hybrid schemes which take advantage of both unsteady RANS and LES have been proposed. This study investigated an alternative scheme, the time-filtered Navier-Stokes (TFNS) method applied to compressible flows. The method developed by Shih and Liu was implemented in the Glenn-HT code and applied to film cooling flows. In this report the method and its implementation is briefly described. The film effectiveness results obtained for film cooling from a row of 30 holes with a pitch of 3.0 diameters emitting air at a nominal density ratio of unity and four blowing ratios of 0.5, 1.0, 1.5 and 2.0 are shown. Flow features under those conditions are also described.

infrared↗

Development of the Glenn-Heat-Transfer (Glenn-HT) Computer Code to Enable Time-Filtered Navier Stokes (TFNS) Simulations and Application to Film Cooling on a Flat Plate Through Long Cooling Tubes

Computational fluid dynamics (CFD) analysis using Reynolds-averaged Navier-Stokes (RANS) formulation for turbomachinery-related flows has enabled improved engine component designs. RANS methodology has limitations that are related to its inability to accurately describe the spectrum of flow phenomena encountered in engines. Examples of flows that are difficult to compute accurately with RANS include phenomena such as laminar/turbulent transition, turbulent mixing due to mixing of streams, and separated flows. Large eddy simulation (LES) can improve accuracy but at a considerably higher cost. In recent years, hybrid schemes that take advantage of both unsteady RANS and LES have been proposed. This study investigated an alternative scheme, the time-filtered Navier-Stokes (TFNS) method applied to compressible flows. The method developed by Shih and Liu was implemented in the Glenn-Heat-Transfer (Glenn-HT) code and applied to film-cooling flows. In this report the method and its implementation is briefly described. The film effectiveness results obtained for film cooling from a row of 30deg holes with a pitch of 3.0 diameters emitting air at a nominal density ratio of unity and two blowing ratios of 0.5 and 1.0 are shown. Flow features under those conditions are also described.

heat transfer↗

Transition Induced by a Streamwise Array of Roughness Elements on a Supersonic Flat Plate

Roughness is unavoidable on practical high-speed vehicles, so it is critical to determine its impact on boundary layer transition. The flow field downstream of a streamwise array of cylindrical roughness elements is probed with hot-wire anemometry in this experiment. Mean flow distortion is examined in several measurement planes in the wake of the cylindrical roughness using the streak strength profiles and contour plots of the mass flux and total temperature. The roughness element heights and spacings were varied and their instability modes were examined. Cylindrical roughness elements approximately 140 micron tall produce an odd instability mode that grows weakly with downstream distance in the measurement range of this experiment. Cylindrical roughness elements approximately 280 micron tall produce an even instability mode that grows, becomes nonlinear, and then breaks down. Transition onset remains constant relative to the most downstream roughness in the streamwise array when the 280 micron roughness elements are spaced 2 diameters apart. Transition onset occurs at an earlier upstream location relative to the most downstream roughness in the streamwise array when the roughness elements are spaced 4 diameters appear to recover before the next downstream roughness element, so the location of transition shifts with the location of the most downstream roughness element in the array. When the rough- apart. The wake behind roughness elements spaced 2 diameters apart do not ness elements are spaced 4 diameters apart, the flow behind the first roughness element has enough space to recover before feeding into the second roughness element, and thus, moves transition forward.

Chou, Amanda↗

Guarded Flat Plate Cryogenic Test Apparatus and Calorimeter

A test apparatus for thermal energy measurement of disk-shaped test specimens has a cold mass assembly locatable within a sealable chamber with a guard vessel having a guard chamber to receive a liquid fluid and a bottom surface to contact a cold side of a test specimen, and a test vessel having a test chamber to receive a liquid fluid and encompassed on one side by a center portion of the bottom surface shared with the guard vessel. A lateral wall assembly of the test vessel is closed by a vessel top, the lateral wall assembly comprising an outer wall and an inner wall having opposing surfaces that define a thermal break including a condensable vapor pocket to inhibit heat transfer through the lateral wall from the guard vessel to the test vessel. A warm boundary temperature surface is in thermal communication with a lower surface of the test specimen.

Fesmire, James E.↗

Guarded Flat Plate Cryogenic Test Apparatus and Calorimeter (C-600)

A test apparatus for thermal energy measurement of disk-shaped test specimens has a cold mass assembly locatable within a sealable chamber with a guard vessel having a guard chamber to receive a liquid fluid and a bottom surface to contact a cold side of a test specimen, and a test vessel having a test chamber to receive a liquid fluid and encompassed on one side by a center portion of the bottom surface shared with the guard vessel. A lateral wall assembly of the test vessel is closed by a vessel top, the lateral wall assembly comprising an outer wall and an inner wall having opposing surfaces that define a thermal break including a condensable vapor pocket to inhibit heat transfer through the lateral wall from the guard vessel to the test vessel. A warm boundary temperature surface is in thermal communication with a lower surface of the test specimen.

Fesmire, James E.↗

Characterization of Flat-Plate Heat Pipe Functionality for Fuel Cell Application

For many exothermic systems such as proton exchange membrane (PEM) fuel cells, cooling is necessary to maintain consistent and uniform operating temperatures which are generally in the range of 60 to 80°C. A potential solution is a heat pipe employing the principle of conduction in combination with a phase change. The purpose of this study was to fully characterize the operation of a heat pipe with unique geometry designed for fuel cell heat removal at operating temperatures up to 100°C and to assess the suitability of the resulting performance for cooling system integration. Test variables consist of cold sink thermal contact conductance coefficient improving material usage, heat rejection temperature, contact pressure and area, heat pipe orientation, operational hours, and variability between units. The test results showed that heat pipe performance improves through increased condenser and heat sink contact pressure, thermal contact coating usage, greater condenser area utilization, and colder heat sink temperature. Higher initial heat pipe temperature and greater age or operation time reduce the heat pipe capabilities. Placing the condenser lower than the evaporator is the only heat pipe orientation that affects evaporator plate temperature. Condensing fluid in the lower section reduces heat transfer capacity as that orientation requires liquid water to transport by wicking against gravity.

Smith, Phillip J.↗

Transition Induced by Tandem Rectangular Roughness Elements on a Supersonic Flat Plate

The flow behind two rectangular roughness elements with a height approximately 38-41 percent of the boundary layer thickness was examined with a hot-wire probe. The rectangular roughness elements are oriented so that one element was at a plus 45-degree angle relative to the leading edge of the plate. A second roughness element was placed 7.16 millimeters downstream of the first one with either the same orientation relative to the leading edge of the plate, or an opposing orientation of minus 45 degrees from the leading edge. Mean mass-flux and total-temperature profiles of the flow field downstream of the tandem roughness elements were examined for mean-flow distortion. Using streak strength as a measure of mean-flow distortion, the tandem roughness elements had approximately the same amount of distortion, regardless of their relative orientation. Mass-flux fluctuation profiles show that the dominant mode downstream of the tandem roughness elements with the same orientation was similar to that of a single roughness element and centered at a frequency of approximately 55 kilohertz (kHz). The dominant instability downstream of the tandem roughness elements with opposing orientation was centered at a frequency of 65 kHz and grew more slowly than the instabilities behind the single roughness element.

Chou, Amanda↗

Transition induced by Streamwise Arrays of Roughness Elements on a Flat Plate in Mach 3.5 Flow

The flow behind streamwise arrays of roughness elements was examined with a hot-wire probe. The roughness elements had heights of approximately 20% and 40% of the boundary layer thickness and different spacings and orientations of these roughness elements were tested. The circular roughness elements were spaced two diameters apart or four diameters apart from center to center. Transition moved upstream only when the roughness elements were spaced four diameters apart. The rectangular roughness elements were oriented so that they were at a 45-degree angle relative to the leading edge of the plate. Tandem rectangular elements either had the same orientation or opposing orientation. Mean mass-flux and total-temperature profiles of the flow field downstream of the roughness elements were examined for mean-flow distortion. Mass-flux fluctuation profiles showed that a 45-kHz odd-mode disturbance was present downstream of the shorter circular roughness elements. The dominant instability downstream of the taller circular roughness elements was a 65–85 kHz even-mode disturbance. Mass-flux fluctuation profiles showed that the dominant mode downstream of the tandem rectangular roughness elements with the same orientation was similar to that of a single roughness element and centered at a frequency of approximately 55 kHz. The 55-kHz instability appeared to correspond to increased spanwise shear, and thus was determined to be an odd-like mode. The dominant instability downstream of the tandem roughness elements with opposing orientation was centered at a frequency of 65 kHz and did not transition in the measurement region.

Amanda Chou↗

Transition Induced by an Egg-Crate Roughness on a Flat Plate in Supersonic Flow

Measurements were made in the wake of a roughness patch with a hot wire to determine mode shapes and frequencies of the dominant instabilities. The egg-crate roughness pattern is an analytic function described by a sinusoidal equation, similar to arrays of discrete elements that are positioned in a spanwise and streamwise grid, which were considered in previous computations. This is an intermediate configuration toward understanding the underlying physics of pseudorandom distributed roughness. At a freestream unit Reynolds number of10.8×106/m, the boundary layer did not transition within the measurement region. The largest amplitude boundary layer instability was centered near 53 kHz and appeared to be similar to an antisymmetric mode centered behind the region downstream of all of the peaks in the egg-crate roughness. This mode was similar to a mode found to have the highest N factor in previous computational studies. At a freestream unit Reynolds number of12.6×106/m, the boundary layer transitioned to turbulence. The dominant instability was centered near 74 kHz and grew linearly before saturating and breaking down. The mode shape of the 74-kHz mode was again an antisymmetric mode centered behind all of the peaks in the egg-crate roughness.

Amanda Chou↗

Instabilities in the Wake of Roughness on a Flat Plate in a Quiet Supersonic Tunnel

Roughness-induced transition is an unavoidable reality in practical high-speed vehicles. Typical prediction of transition due to roughness include algebraic correlations and, more recently, semi-empirical methods. In the NASA Langley Research Center Supersonic Low Disturbance Tunnel, a Mach 3.5 quiet tunnel, several transition experiments have been performed in the past decade to better understand the mechanisms by which small roughness causes transition in a supersonic boundary layer. The study started first with isolated roughness elements of different planforms and shapes and progressed to increasingly more complicated geometries before arriving at a pseudorandom roughness, defined by an analytic function. Concurrent computational efforts progressed with these studies as well, starting with the use of linear stability theory and progressing to the use of harmonic linearized Navier-Stokes to predict the growth of boundary layer stabilities.

Amanda Chou↗