Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

International Collaboration Framework for the Calculation of Performance Loss Rates: Data Quality, Benchmarks, and Trends

Within the IEA PVPS Task 13, a group of experts representing several leading R&D centres, universities and industry companies, is developing a framework for the calculation of Performance Loss Rates (PLR) on a large number of commercial and research PV power plants and related weather data coming from various climatic zones. Various methodologies are applied for the calculation of PLR which are benchmarked in terms of uncertainties and 'true' values. The aim of the international collaboration is to show how to calculate the PLR on high quality (high time resolution, reliable data, irradiance, yield, etc.) and on low quality data (low time resolution, only energy data available). Various algorithms and models, along with different time averaging and filtering criteria, can be applied for the calculation of PLR each of which can have an impact on the results. The approach considers three pathways to ensure broad collaboration and increase the statistical relevance of the study: i) use of shared methodologies on shared time series, ii) use of confidential methodologies on shared time series, iii) use of shared methodologies on confidential time series. The data is used for benchmarking activities and to define which methodologies clusters around a 'true value' of PLR. The combination of metrics (PR or power based) and methodologies are benchmarked in terms of deviation from the average value and in terms of standard deviation. The combination of temperature corrected PR with the use of Year on Year (YOY) or Seasonal Trend decomposition using Loess (STL) performs well for all systems; other methodologies seems to be more depending on the filtering applied. Another set of data is represented by the IEA PVPS Task 13 'PV performance database' which includes more than 120 PV plants from different climates. The applied methodologies were STL and the YoY approach. STL results in an averaged PLR over all systems of -0.78%/a while YoY yields -0.63%/a. STL is better suited if the time series data are of higher resolution and high-quality weather data are available. One important outcome of this study is the setting of a framework for the contribution to a clear and structured quality classification for PV time series data and a guideline for PLR calculations in dependency of the data categorization.

14 SOLAR ENERGY↗

Performance Evaluation of HYCOM-GOM for Hydrokinetic Resource Assessment in the Florida Strait

The U.S. Department of Energy (DoE) is assessing and mapping the potential off-shore ocean current hydrokinetic energy resources along the U.S. coastline, excluding tidal currents, to facilitate market penetration of water power technologies. This resource assessment includes information on the temporal and three-dimensional spatial distribution of the daily averaged power density, and the overall theoretical hydrokinetic energy production, based on modeled historical simulations spanning a 7-year period of record using HYCOM-GOM, an ocean current observation assimilation model that generates a spatially distributed three-dimensional representation of daily averaged horizontal current magnitude and direction time series from which power density time series and their statistics can be derived. This study ascertains the deviation of HYCOM-GOM outputs, including transport (flow) and power density, from outputs based on three independent observation sources to evaluate HYCOM-GOM performance. The three independent data sources include NOAA s submarine cable data of transport, ADCP data at a high power density location, and HF radar data in the high power density region of the Florida Strait. Comparisons with these three independent observation sets indicate discrepancies with HYCOM model outputs, but overall indicate that the HYCOM-GOM model can provide an adequate assessment of the ocean current hydrokinetic resource in high power density regions like the Florida Strait. Additional independent observational data, in particular stationary ADCP measurements, would be useful for expanding this model performance evaluation study. ADCP measurements are rare in ocean environments not influenced by tides, and limited to one location in the Florida Strait. HF radar data, although providing great spatial coverage, is limited to surface currents only.

ADCP↗

Improving the space surveillance telescope's performance using multi-hypothesis testing

The Space Surveillance Telescope (SST) is a Defense Advanced Research Projects Agency program designed to detect objects in space like near Earth asteroids and space debris in the geosynchronous Earth orbit (GEO) belt. Binary hypothesis test (BHT) methods have historically been used to facilitate the detection of new objects in space. In this paper a multi-hypothesis detection strategy is introduced to improve the detection performance of SST. In this context, the multi-hypothesis testing (MHT) determines if an unresolvable point source is in either the center, a corner, or a side of a pixel in contrast to BHT, which only tests whether an object is in the pixel or not. The images recorded by SST are undersampled such as to cause aliasing, which degrades the performance of traditional detection schemes. The equations for the MHT are derived in terms of signal-to-noise ratio (S/N), which is computed by subtracting the background light level around the pixel being tested and dividing by the standard deviation of the noise. A new method for determining the local noise statistics that rejects outliers is introduced in combination with the MHT. An experiment using observations of a known GEO satellite are used to demonstrate the improved detection performance of the new algorithm over algorithms previously reported in the literature. The results show a significant improvement in the probability of detection by as much as 50% over existing algorithms. In addition to detection, the S/N results prove to be linearly related to the least-squares estimates of point source irradiance, thus improving photometric accuracy.

79 ASTRONOMY AND ASTROPHYSICS↗

A robust calibration of the clumped isotopes to temperature relationship for foraminifers

The clumped isotope (Δ 47 ) proxy is a promising geochemical tool to reconstruct past ocean temperatures far back in time and in unknown settings, due to its unique thermodynamic basis that renders it independent from other environmental factors like seawater composition. Although previously hampered by large sample-size requirements, recent methodological advances have made the paleoceanographic application of Δ 47 on small (<5 mg) foraminifer samples possible. Previous studies show a reasonable match between Δ 47 calibrations based on synthetic carbonate and various species of planktonic foraminifers. However, studies performed before recent methodological advances were based on relatively few species and data treatment that is now outdated. To overcome these limitations and elucidate species-specific effects, we analyzed 14 species of planktonic foraminifers in sediment surface samples from 13 sites, covering a growth temperature range of ~0-28 °C. We selected mixed layer-dwelling and deep-dwelling species from a wide range of ocean settings to evaluate the feasibility of temperature reconstructions for different water depths. Various techniques to estimate foraminifer calcification temperatures were tested in order to assess their effects on the calibration and to find the most suitable approach. Results from this study generally confirm previous findings that there are no species-specific effects on the Δ 47 -temperature relationship in planktonic foraminifers, with one possible exception. Various morphotypes of Globigerinoides ruber were found to often deviate from the general trend determined for planktonic foraminifers. Our data are in excellent agreement with a recent foraminifer calibration study that was performed with a different analytical setup, as well as with a calibration based exclusively on benthic foraminifers. A combined, methodologically homogenized dataset also reveals very good agreement with an inorganic calibration based on travertines. Our findings highlight the potential of the Δ 47 paleothermometer to be applied to recent and extinct species alike to study surface ocean temperatures as well as thermocline variability for a multitude of settings and time scales.

58 GEOSCIENCES↗

Concurrent Inter-Model Spread of Boreal Winter Westerly Jet Meridional Positions Between the Northern and Southern Hemispheres in CMIP6 Models

Here, this study investigates the inter-model spread of climatological extratropical westerly jets in boreal winter, using the historical simulation of 52 Coupled Model Intercomparison Project phase 6 (CMIP6) models from 1851 to 2014. The results show that there is a substantial spread in the latitude of the upper-tropospheric westerly jet across models, characterised by large inter-model standard deviations to both the poleward and equatorward sides of the jet axis, although the multi-model ensemble mean (MME) performs well in simulating meridional position of westerly jets. Furthermore, we detect the consistency of inter-model jet position spread between the Northern and Southern Hemispheres, based on the inter-model empirical orthogonal function (EOF) decomposition and correlation of regional-averaged zonal winds. Specifically, the models that simulate the westerly jets poleward/equatorward relative to the MME position in one hemisphere also tend to simulate the jets poleward/equatorward in the other hemisphere. Accordingly, we define a global jet spread index to depict the concurrence of jet shift in the two hemispheres. The results of inter-model regression analyses based on this index indicate that the models positioning the jets poleward than the MME tend to simulate a wider Hadley Cell, a poleward-shifted Ferrel Cell in the Southern Hemisphere, enhanced precipitation in the subtropics and suppressed precipitation in the tropics, and warmer sea surface temperatures in the subtropics and mid-latitudes. The present results suggest that improving the simulation of jet positions in climate models requires a comprehensive consideration of thermal states in the tropics and subtropics/mid latitudes.

54 ENVIRONMENTAL SCIENCES↗

Inclusive production cross sections at N 3 LO

We present for the first time the inclusive cross section for associated Higgs boson production with a massive gauge boson at next-to-next-to-next-to-leading order in QCD. Furthermore, we introduce n3loxs, a public, numerical program for the evaluation of inclusive cross sections at the third order in the strong coupling constant. Our tool allows to derive predictions for charged- and neutral-current Drell-Yan production, gluon- and bottom-quark-fusion Higgs boson production and Higgs boson associated production with a heavy gauge boson. We discuss perturbative and parton distribution function (PDF) uncertainties of the aforementioned processes. We perform a comparison of global PDF sets for a variety of process including associated Higgs boson production and observe 1σ deviations among predictions for several processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Stationary Distribution and Perturbation Bounds for a Stochastic Inventory Model

In this paper, we use the theory of generalized inverses to compute the stationary distribution of the (s, S) inventory model directly from the transition matrix of the underlying Markov chain and to provide perturbation bounds. Indeed, approximations are employed to build a tractable model, and statistical methods are used to estimate the unknown parameters and distributions. Hence, the system is subject to perturbations that may cause deviation in the characteristics. The proposed perturbation bound provides a means to estimate the impact of the perturbations on the performance measures of the considered inventory system.

97 MATHEMATICS AND COMPUTING↗

Validation of Supervised Automated Algorithm for Fast Quantitative Evaluation of Organ Motion on Magnetic Resonance Imaging

Purpose: To validate a correlation coefficient template-matching algorithm applied to the supervised automated quantification of abdominal-pelvic organ motion captured on time-resolved magnetic resonance imaging. Methods and Materials: Magnetic resonance images of 21 patients across four anatomic sites were analyzed. Representative anatomic points of interest were chosen as surrogates for organ motion. The point of interest displacements across each image frame relative to baseline were quantified manually and through the use of a template-matching software tool, termed 'Motiontrack.' Automated and manually acquired displacement measures, as well as the standard deviation of intrafraction motion, were compared for each image frame and for each patient. Results: Discrepancies between the automated and manual displacements of {>=}2 mm were uncommon, ranging in frequency of 0-9.7% (liver and prostate, respectively). The standard deviations of intrafraction motion measured with each method correlated highly (r = 0.99). Considerable interpatient variability in organ motion was demonstrated by a wide range of standard deviations in the liver (1.4-7.5 mm), uterus (1.1-8.4 mm), and prostate gland (0.8-2.7 mm). The automated algorithm performed successfully in all patients but 1 and substantially improved efficiency compared with manual quantification techniques (5 min vs. 60-90 min). Conclusion: Supervised automated quantification of organ motion captured on magnetic resonance imaging using a correlation coefficient template-matching algorithm was efficient, accurate, and may play an important role in off-line adaptive approaches to intrafraction motion management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Interfraction Prostate Motion Using Megavoltage Cone Beam Computed Tomography

Purpose: Determine the degree of interfraction prostate motion and its components measured by using daily megavoltage (MV) cone beam computed tomography (CBCT) imaging. Methods and Materials: A total of 984 daily MV CBCT images from 24 patients undergoing definitive intensity-modulated radiotherapy for localized prostate cancer were analyzed retrospectively. Pretreatment couch shifts, based on physician registration of MV CBCT to planning CT data sets, were used as a measure of daily interfraction motion. Off-line bony registration was performed to separate bony misalignment from internal organ motion. Interobserver and intraobserver variation studies were performed on 20 MV CBCT images. Results: Mean interfraction prostate motion was 6.7 mm, with the greatest single-axis deviation in the anterior-posterior (AP) direction. The largest positional inaccuracy was accounted for by systematic deviations in bony misalignment, whereas random deviations occurred from bony misalignment and internal prostate motion. In the aggregate, AP motion did not correlate with days elapsed since beginning therapy or on average with rectal size at treatment planning. Interobserver variation was greatest in the AP direction, decreased in experienced observers, and further decreased in intraobserver studies. Mean interfraction motion during the first 6 days of therapy, when used as a subsequent offset, reduced acceptable AP planning target volume margins by 50%. Conclusion: The MV CBCT is a practical direct method of daily localization that shows significant interfraction motion with respect to conventional three-dimensional conformal and intensity-modulated radiotherapy margins, similar to that measured in other modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Point defects diagrams for pure and doped copper oxide Cu{sub 2{+-}{delta}}O in the temperature range of 873-1473 K

Point defects diagrams for the Cu{sub 2{+-}{delta}}O, both pure and doped with M{sup 2+} metal ions with all the types of defects in the cation sublattice considered are presented in this work. The calculations of the diagrams were performed by a novel method. The calculations were based on the data from the results of the studies of the deviation from stoichiometry and the electrical conductivity in the temperature range of 873-1473 K. The values of {Delta}G{sup o} of the formation of Frenkel-type defects, of copper vacancies, and of interstitial copper atoms were determined and their temperature dependence. It was shown that character of the dependence of the sum of concentrations of electronic defects ([h{sup Bullet }]+b[e Prime ]) on p{sub O{sub 2}} is fully consistent with its dependence of the electrical conductivity. Their mobility ({mu}{sub e}/{mu}{sub h}=b), vary from 1300 to 30. The dope M{sup 2+} increases the concentration of electrons and shifts the minimum of electrical conductivity toward higher oxygen pressures. - Graphical abstract: This work presents point defects diagrams for the Cu{sub 2{+-}{delta}}O, with all the types of defects in the cation sublattice considered. Highlights: Black-Right-Pointing-Pointer The point defects diagrams. Copper oxide Cu{sub 2{+-}{delta}}O, for pure and M{sup 2+} doped. Black-Right-Pointing-Pointer The values of {Delta}G{sup o} of the formation of Frenkel-type defects were determined. Black-Right-Pointing-Pointer The values of {Delta}G{sup o} of the formation QUOTE QUOTE of singly-ionized copper vacancies were determined. Black-Right-Pointing-Pointer The values of {Delta}G{sup o} of the formation of electroneutral copper vacancies were determined. Black-Right-Pointing-Pointer The values of {Delta}G{sup o} of the formation and of interstitial copper atoms were determined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Ground State Electronic Energy of Benzene

We report here on the findings of a blind challenge devoted to determining the frozen-core, full configuration interaction (FCI) ground-state energy of the benzene molecule in a standard correlation-consistent basis set of double-ζ quality. As a broad international endeavor, our suite of wave function-based correlation methods collectively represents a diverse view of the high-accuracy repertoire offered by modern electronic structure theory. In our assessment, the evaluated high-level methods are all found to qualitatively agree on a final correlation energy, with most methods yielding an estimate of the FCI value around -863 mE H . However, we find the root-mean-square deviation of the energies from the studied methods to be considerable (1.3 mE H ), which in light of the acclaimed performance of each of the methods for smaller molecular systems clearly displays the challenges faced in extending reliable, near-exact correlation methods to larger systems. While the discrepancies exposed by our study thus emphasize the fact that the current state-of-the-art approaches leave room for improvement, we still expect the present assessment to provide a valuable community resource for benchmark and calibration purposes going forward.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular simulation of thermodynamic and transport properties for the H{sub 2}O+NaCl system

Molecular dynamics and Monte Carlo simulations have been carried out to obtain thermodynamic and transport properties of the binary mixture H{sub 2}O+NaCl at temperatures from T = 298 to 473 K. In particular, vapor pressures, liquid densities, viscosities, and vapor-liquid interfacial tensions have been obtained as functions of pressure and salt concentration. Several previously proposed fixed-point-charge models that include either Lennard-Jones (LJ) 12-6 or exponential-6 (Exp6) functional forms to describe non-Coulombic interactions were studied. In particular, for water we used the SPC and SPC/E (LJ) models in their rigid forms, a semiflexible version of the SPC/E (LJ) model, and the Errington-Panagiotopoulos Exp6 model; for NaCl, we used the Smith-Dang and Joung-Cheatham (LJ) parameterizations as well as the Tosi-Fumi (Exp6) model. While none of the model combinations are able to reproduce simultaneously all target properties, vapor pressures are well represented using the SPC plus Joung-Cheathem model combination, and all LJ models do well for the liquid density, with the semiflexible SPC/E plus Joung-Cheatham combination being the most accurate. For viscosities, the combination of rigid SPC/E plus Smith-Dang is the best alternative. For interfacial tensions, the combination of the semiflexible SPC/E plus Smith-Dang or Joung-Cheatham gives the best results. Inclusion of water flexibility improves the mixture densities and interfacial tensions, at the cost of larger deviations for the vapor pressures and viscosities. The Exp6 water plus Tosi-Fumi salt model combination was found to perform poorly for most of the properties of interest, in particular being unable to describe the experimental trend for the vapor pressure as a function of salt concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microgrids for Service Restoration to Critical Load in a Resilient Distribution System

icrogrids can act as emergency sources to serve critical loads when utility power is unavailable. This paper proposes a resiliency-based methodology that uses microgrids to restore critical loads on distribution feeders after a major disaster. Due to limited capacity of distributed generators (DGs) within microgrids, dynamic performance of the DGs during the restoration process becomes essential. In this paper, the stability of microgrids, limits on frequency deviation, and limits on transient voltage and current of DGs are incorporated as constraints of the critical load restoration problem. The limits on the amount of generation resources within microgrids are also considered. By introducing the concepts of restoration tree and load group, restoration of critical loads is transformed into a maximum coverage problem, which is a linear integer program (LIP). The restoration paths and actions are determined for critical loads by solving the LIP. A 4-feeder, 1069-bus unbalanced test system with four microgrids is utilized to demonstrate the effectiveness of the proposed method. The method is applied to the distribution system in Pullman, WA, resulting in a strategy that uses generators on the Washington State University campus to restore service to the Hospital and City Hall in Pullman.

Xu, Yin (ORCID:0000000209459024)↗

Super B Progress Report for Physics

Super B is a high luminosity e + e - collider that will be able to indirectly probe new physics at energy scales far beyond the reach of any man made accelerator planned or in existence. Just as detailed understanding of the Standard Model of particle physics was developed from stringent constraints imposed by flavour changing processes between quarks, the detailed structure of any new physics is severely constrained by flavour processes. In order to elucidate this structure it is necessary to perform a number of complementary studies of a set of golden channels. With these measurements in hand, the pattern of deviations from the Standard Model behavior can be used as a test of the structure of new physics. If new physics is found at the LHC, then the many golden measurements from Super B will help decode the subtle nature of the new physics. However if no new particles are found at the LHC, Super B will be able to search for new physics at energy scales up to 10-100 TeV. In either scenario, flavour physics measurements that can be made at Super B play a pivotal role in understanding the nature of physics beyond the Standard Model. Examples for using the interplay between measurements to discriminate New Physics models are discussed in this document.s detail the Physics case of the Super B Project.

43 PARTICLE ACCELERATORS↗

Qualification for PowerInsight accuracy of power measurements

Accuracy of component based power measuring devices forms a necessary basis for research in the area of power-efficient and power-aware computing. The accuracy of these devices must be quantified within a reasonable tolerance. This study focuses on PowerInsight, an out- of-band embedded measuring device which takes readings of power rails on compute nodes within a HPC system in realtime. We quantify how well the device performs in comparison to a digital oscilloscope as well as PowerMon2. We show that the accuracy is within a 6% deviation on measurements under reasonable load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of the Repeatability of the Delta Q Duct Leakage Testing TechniqueIncluding Investigation of Robust Analysis Techniques and Estimates of Weather Induced Uncertainty

The DeltaQ test is a method of estimating the air leakage from forced air duct systems. Developed primarily for residential and small commercial applications it uses the changes in blower door test results due to forced air system operation. Previous studies established the principles behind DeltaQ testing, but raised issues of precision of the test, particularly for leaky homes on windy days. Details of the measurement technique are available in an ASTM Standard (ASTM E1554-2007). In order to ease adoption of the test method, this study answers questions regarding the uncertainty due to changing weather during the test (particularly changes in wind speed) and the applicability to low leakage systems. The first question arises because the building envelope air flows and pressures used in the DeltaQ test are influenced by weather induced pressures. Variability in wind induced pressures rather than temperature difference induced pressures dominates this effect because the wind pressures change rapidly over the time period of a test. The second question needs to answered so that DeltaQ testing can be used in programs requiring or giving credit for tight ducts (e.g., California's Building Energy Code (CEC 2005)). DeltaQ modeling biases have been previously investigated in laboratory studies where there was no weather induced changes in envelope flows and pressures. Laboratory work by Andrews (2002) and Walker et al. (2004) found biases of about 0.5% of forced air system blower flow and individual test uncertainty of about 2% of forced air system blower flow. The laboratory tests were repeated by Walker and Dickerhoff (2006 and 2008) using a new ramping technique that continuously varied envelope pressures and air flows rather than taking data at pre-selected pressure stations (as used in ASTM E1554-2003 and other previous studies). The biases and individual test uncertainties for ramping were found to be very close (less than 0.5% of air handler flow) to those found in for the pressure station approach. Walker and Dickerhoff also included estimates of DeltaQ test repeatability based on the results of field tests where two houses were tested multiple times. The two houses were quite leaky (20-25 Air Changes per Hour at 50Pa (0.2 in. water) (ACH50)) and were located in the San Francisco Bay area. One house was tested on a calm day and the other on a very windy day. Results were also presented for two additional houses that were tested by other researchers in Minneapolis, MN and Madison, WI, that had very tight envelopes (1.8 and 2.5 ACH50). These tight houses had internal duct systems and were tested without operating the central blower--sometimes referred to as control tests. The standard deviations between the multiple tests for all four houses were found to be about 1% of the envelope air flow at 50 Pa (0.2 in. water) (Q50) that led to the suggestion of this as a rule of thumb for estimating DeltaQ uncertainty. Because DeltaQ is based on measuring envelope air flows it makes sense for uncertainty to scale with envelope leakage. However, these tests were on a limited data set and one of the objectives of the current study is to increase the number of tested houses. This study focuses on answering two questions: (1) What is the uncertainty associated with changes in weather (primarily wind) conditions during DeltaQ testing? (2) How can these uncertainties be reduced? The first question is addressing issues of repeatability. To study this five houses were tested as many times as possible over a day. Weather data was recorded on-site--including the local windspeed. The result from these five houses were combined with the two Bay Area homes from the previous studies. The variability of the tests (represented by the standard deviation) is the repeatability of the test method for that house under the prevailing weather conditions. Because the testing was performed over a day a wide range of wind speeds was achieved following typical diurnal variations of low wind in the early morning and greatest winds in the late afternoon/early evening. Typically about ten tests were performed in each house. To answer the second question, different data analysis techniques were investigated that looked at averaging techniques, elimination of outliers, limiting leak pressures, etc. in order to minimize the influence of changing wind conditions during the test. The objective was to find a reasonable compromise between test precision and robustness--because many of the changes to the analysis to make the test more robust limit its ability to examine wide ranges of pressures and leakage flows. A secondary goal of this study is to show that DeltaQ uncertainties are acceptable for testing low leakage systems. Therefore houses with low duct leakage were deliberately chosen to be tested.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commissioning a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of the quadrupoles. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing such a system. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). A previous study investigated the error associated with each step by using a permanent quadrupole magnet on an optical mover system. The study reported an error of 11{micro}m for step 1 and a repeatability of 4{micro}m for step 2. However, the set up used a FARO arm to measure tooling balls and didn't allow to accurately check step 2 for errors; an uncertainty of 100{micro}m was reported. Therefore, even though the repeatability was good, there was no way to check that the error in step 2 was small. Following the recommendations of that study, we used a CMM (Coordinate Measuring Machine) instead of the FARO arm for measuring the tooling balls. In addition, a roller cam positioner system replaced the optical movers for moving the quadrupole. With the exception of the quadrupole itself, the system was identical to what will be used in fiducializing the undulator quadrupoles. In this study, we investigate the new vibrating wire set up, including the error associated with each step of fiducialization. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note is a continuation of previous work to study the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

Set Up and Test Results for a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of a quadrupole. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing it. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). The following break up of error was suggested for the fiducialization steps: 10{micro}m for step 1 (finding the center), 20{micro}m for step 2 (finding the wire), and 10{micro}m for step 3 (tooling ball measurements). The purpose of this study is to investigate whether the vibrating wire system meets the requirements for LCLS. In particular, if it can reliably fiducialize a quadrupole magnetic center to within 25{micro}m in both vertical and horizontal directions. The behavior of individual system components is compared to the expected performance. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note studies the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗