Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

EFFECTS OF ASYMMETRIC FLOWS IN SOLAR CONVECTION ON OSCILLATION MODES

Many helioseismic measurements suffer from substantial systematic errors. A particularly frustrating one is that time-distance measurements suffer from a large center to limb effect which looks very similar to the finite light travel time, except that the magnitude depends on the observable used and can have the opposite sign. This has frustrated attempts to determine the deep meridional flow in the solar convection zone, with Zhao et al. applying an ad hoc correction with little physical basis to correct the data. In this Letter, we propose that part of this effect can be explained by the highly asymmetrical nature of the solar granulation which results in what appears to the oscillation modes as a net radial flow, thereby imparting a phase shift on the modes as a function of observing height and thus heliocentric angle.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High resolution 3D gas-jet characterization

We present a tomographic characterization of gas jets employed for high-intensity laser-plasma interaction experiments where the shape can be non-symmetrically. With a Mach-Zehnder interferometer we measured the phase shift for different directions through the neutral density distribution of the gas jet. From the recorded interferograms it is possible to retrieve 3-dimensional neutral density distributions by tomographic reconstruction based on the filtered back projections. We report on criteria for the smallest number of recorded interferograms as well as a comparison with the widely used phase retrieval based on an Abel inversion. As an example for the performance of our approach, we present the characterization of nozzles with rectangular openings or gas jets with shock waves. With our setup we obtained a spatial resolution of less than 60 {mu}m for an Argon density as low as 2 x 10{sup 17} cm{sup -3}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical exploration of laser-parameter effects on the generation of an isolated attosecond pulse from two-color high-order harmonic generation

In the present work, laser-parameter effects on the isolated attosecond pulse generation from two-color high-order harmonic generation (HHG) process are theoretically investigated by use of a wave-packet dynamics method. A 6-fs, 800-nm, 6x10{sup 14}W/cm{sup 2}, linearly polarized laser pulse serves as the fundamental driving pulse and parallel linearly polarized control pulses at 400 nm (second harmonic) and 1600 nm (half harmonic) are superimposed to create a two-color field. Of the two techniques, we demonstrate that using a half-harmonic control pulse with a large relative strength and zero phase shift relative to the fundamental pulse is a more promising way to generate the shortest attosecond pulses. As a consequence, an isolated 12-as pulse is obtained by Fourier transforming an ultrabroad xuv continuum of 300 eV in the HHG spectrum under half-harmonic control scheme when the relative strength {radical}(R)=0.6 and relative phase =0.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Holotomography Phase-Retrieval

Holotomography is a non-destructive x-ray imaging technique which allows to visualize the interior morphology of object without damaging them. It is similar to x-ray computed tomography (CT), but unlike conventional CT, which is based on the attenuation of x-rays passing through the object, holotomography exploits the phase shift caused by the sample. This phase-contrast imaging allows to increase image contrast by recovering refractive index of materials and is proven to be more sensitive to density variations than conventional absorption-based X-ray imaging when applied to low-Z materials. In holotomography, the phase is retrieved by measuring the variations in intensity of the object at different sample to detector distances. Several algorithms exist to perform this task such as, contrast transfer function (CTF), transport of intensity equation (TIE), and a mixed approach which combine both TIE and CTF.

Forien, Jean-Baptiste↗

TOWARD A MAGNETOHYDRODYNAMIC THEORY OF THE STATIONARY ACCRETION SHOCK INSTABILITY: TOY MODEL OF THE ADVECTIVE-ACOUSTIC CYCLE IN A MAGNETIZED FLOW

The effect of a magnetic field on the linear phase of the advective-acoustic instability is investigated as a first step toward a magnetohydrodynamic (MHD) theory of the stationary accretion shock instability taking place during stellar core collapse. We study a toy model where the flow behind a planar stationary accretion shock is adiabatically decelerated by an external potential. Two magnetic field geometries are considered: parallel or perpendicular to the shock. The entropy-vorticity wave, which is simply advected in the unmagnetized limit, separates into five different waves: the entropy perturbations are advected, while the vorticity can propagate along the field lines through two Alfven waves and two slow magnetosonic waves. The two cycles existing in the unmagnetized limit, advective-acoustic and purely acoustic, are replaced by up to six distinct MHD cycles. The phase differences among the cycles play an important role in determining the total cycle efficiency and hence the growth rate. Oscillations in the growth rate as a function of the magnetic field strength are due to this varying phase shift. A vertical magnetic field hardly affects the cycle efficiency in the regime of super-Alfvenic accretion that is considered. In contrast, we find that a horizontal magnetic field strongly increases the efficiencies of the vorticity cycles that bend the field lines, resulting in a significant increase of the growth rate if the different cycles are in phase. These magnetic effects are significant for large-scale modes if the Alfven velocity is a sizable fraction of the flow velocity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Remarks on the origin of Castillejo-Dalitz-Dyson poles

Castillejo-Dalitz-Dyson (CDD) poles are known to be connected with bound states and resonances. We discuss a new type of CDD pole associated with primitives i.e., poles of the P matrix that correspond to zeros of the D function on the unitary cut. The Low scattering equation is generalized for amplitudes with primitives. The relationship between the CDD poles and the primitives is illustrated by a description of the S-wave nucleon-nucleon phase shifts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hard-X-Ray Phase-Difference Microscopy Using a Fresnel Zone Plate and a Transmission Grating

Novel hard x-ray phase imaging microscopy that simply uses an objective and a transmission grating is described. The microscope generated an image that exhibited twin features of a sample with an opposite phase contrast having a separation of a specific distance. Furthermore, the twin features were processed to generate an image mapping the x-ray phase shift through a simple algorithm. The presence of the grating did not degrade the spatial resolution of the microscope. The sensitivity of our microscope to light elements was about 2 orders of magnitude higher than that of the absorption contrast microscope that was attained by simply removing the grating. Our method is attractive for easily appending a quantitative phase-sensitive mode to normal x-ray microscopies, and it has potentially broad applications in biology and material sciences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Some Boussinesq Equations with Saturation

We investigate numerically some Boussinesq type equations with square or cubic and saturated nonlinearity. We examine the propagation, interaction and overtake interaction of soliton solutions. Moreover, we examine the effect of the saturation term on the solution and compare it with the classical case of the square or cubic nonlinearity without saturation. We calculate numerically the phase shift experienced by the solitons upon collision and conclude the impact of saturation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Off-resonance photoemission dynamics studied by recoil frame F1s and C1s photoelectron angular distributions of CH{sub 3}F

F1s and C1s photoelectron angular distributions are considered for CH{sub 3}F, a molecule which does not support any shape resonance. In spite of the absence of features in the photoionization cross section profile, the recoil frame photoelectron angular distributions (RFPADs) exhibits dramatic changes depending on both the photoelectron energy and polarization geometry. Time-dependent density functional theory calculations are also given to rationalize the photoionization dynamics. The RFPADs have been compared with the theoretical calculations, in order to assess the accuracy of the theoretical method and rationalize the experimental findings. The effect of finite acceptance angles for both ionic fragments and photoelectrons has been included in the calculations, as well as the effect of rotational averaging around the fragmentation axis. Excellent agreement between theory and experiment is obtained, confirming the good quality of the calculated dynamical quantities (dipole moments and phase shifts)

74 ATOMIC AND MOLECULAR PHYSICS↗

Motion as a perturbation: Measurement-guided dose estimates to moving patient voxels during modulated arc deliveries

Purpose: To present a framework for measurement-guided VMAT dose reconstruction to moving patient voxels from a known motion kernel and the static phantom data, and to validate this perturbation-based approach with the proof-of-principle experiments. Methods: As described previously, the VMAT 3D dose to a static patient can be estimated by applying a phantom measurement-guided perturbation to the treatment planning system (TPS)-calculated dose grid. The fraction dose to any voxel in the presence of motion, assuming the motion kernel is known, can be derived in a similar fashion by applying a measurement-guided motion perturbation. The dose to the diodes in a helical phantom is recorded at 50 ms intervals and is transformed into a series of time-resolved high-density volumetric dose grids. A moving voxel is propagated through this 4D dose space and the fraction dose to that voxel in the phantom is accumulated. The ratio of this motion-perturbed, reconstructed dose to the TPS dose in the phantom serves as a perturbation factor, applied to the TPS fraction dose to the similarly situated voxel in the patient. This approach was validated by the ion chamber and film measurements on four phantoms of different shape and structure: homogeneous and inhomogeneous cylinders, a homogeneous cube, and an anthropomorphic thoracic phantom. A 2D motion stage was used to simulate the motion. The stage position was synchronized with the beam start time with the respiratory gating simulator. The motion patterns were designed such that the motion speed was in the upper range of the expected tumor motion (1-1.4 cm/s) and the range exceeded the normally observed limits (up to 5.7 cm). The conformal arc plans for X or Y motion (in the IEC 61217 coordinate system) consisted of manually created narrow (3 cm) rectangular strips moving in-phase (tracking) or phase-shifted by 90 Degree-Sign (crossing) with respect to the phantom motion. The XY motion was tested with the computer-derived VMAT MLC sequences. For all phantoms and plans, time-resolved (10 Hz) ion chamber dose was collected. In addition, coronal (XY) films were exposed in the cube phantom to a VMAT beam with two different starting phases, and compared to the reconstructed motion-perturbed dose planes. Results: For the X or Y motions with the moving strip and geometrical phantoms, the maximum difference between perturbation-reconstructed and ion chamber doses did not exceed 1.9%, and the average for any motion pattern/starting phase did not exceed 1.3%. For the VMAT plans on the cubic and thoracic phantoms, one point exhibited a 3.5% error, while the remaining five were all within 1.1%. Across all the measurements (N = 22), the average disagreement was 0.5 {+-} 1.3% (1 SD). The films exhibited {gamma}(3%/3 mm) passing rates {>=}90%. Conclusions: The dose to an arbitrary moving voxel in a patient can be estimated with acceptable accuracy for a VMAT delivery, by performing a single QA measurement with a cylindrical phantom and applying two consecutive perturbations to the TPS-calculated patient dose. The first one accounts for the differences between the planned and delivered static doses, while the second one corrects for the motion.

60 APPLIED LIFE SCIENCES↗

Beam steering via resonance detuning in coherently coupled vertical cavity laser arrays

Coherently coupled vertical-cavity surface-emitting laser arrays offer unique advantages for nonmechanical beam steering applications. We have applied dynamic coupled mode theory to show that the observed temporal phase shift between vertical-cavity surface-emitting array elements is caused by the detuning of their resonant wavelengths. Hence, a complete theoretical connection between the differential current injection into array elements and the beam steering direction has been established. It is found to be a fundamentally unique beam-steering mechanism with distinct advantages in efficiency, compactness, speed, and phase-sensitivity to current.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Low-loss nonlinear polaritonics

We propose a large low-loss cross-phase modulation between two coupled surface polaritons propagating through a double electromagnetically induced transparency medium situated close to a negative-index metamaterial. In particular, a mutual {pi} phase shift is attainable between the two pulses at the single-photon level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase Contrast Imaging

All standard (medical) x-ray imaging technologies, rely primarily on the amplitude properties of the incident radiation, and do not depend on its phase. This is unchanged since the discovery by Roentgen that the intensity of an x-ray beam, as measured by the exposure on a film, was related to the relative transmission properties of an object. However, recently various imaging techniques have emerged which depend on the phase of the x-rays as well as the amplitude. Phase becomes important when the beam is coherent and the imaging system is sensitive to interference phenomena. Significant new advances have been made in coherent optic theory and techniques, which now promise phase information in medical imaging. The development of perfect crystal optics and the increasing availability of synchrotron radiation facilities have contributed to a significant increase in the application of phase based imaging in materials and life sciences. Unique source characteristics such as high intensity, monochromaticity, coherence and high collimating provide an ideal source for advanced imaging. Phase contrast imaging has been applied in both projection and computed tomography modes, and recent applications have been made in the field of medical imaging. Due to the underlying principle of X-ray detection conventional image receptors register only intensities of wave fields and not their phases. During the last decade basically five different methods were developed that translate the phase information into intensity variations. These methods are based on measuring the phase shift {phi} directly (using interference phenomena), the gradient {nabla}{sub {phi}}, or the Laplacian {nabla}{sup 2}{phi}. All three methods can be applied to polychromatic X-ray sources keeping in mind that the native source is synchrotron radiation, featuring monochromatic and reasonable coherent X-ray beams. Due to the vast difference in the coefficients that are driven absorption and phase effects (factor 1,000-10,000 in the energy range suitable for medical imaging) phase based imaging techniques are inherently extremely sensitive.

79 ASTRONOMY AND ASTROPHYSICS↗

A W/B{sub 4}C Transmission Multilayer as an Achromatic Phase Shifter in the XUV: Some Experimental Aspects

Completing previous investigations we study a W/B{sub 4}C transmission multilayer with 350 periods each 1.74 nm as a phase shifter for polarization analysis between 720 eV and 1020 eV. The FWHM of the Bragg curve is as small as 0.18 deg. = 3 mrad and thus smaller than the inherent accuracy of most polarimeters. We discuss some of the experimental implications and limitations. We obtain a phase shift of up to {Delta} = 24 deg. through out the spectral range.

43 PARTICLE ACCELERATORS↗

Quantum interference in superposed lattices

Charge transport in solids at low temperature reveals a material’s mesoscopic properties and structure. Under a magnetic field, Shubnikov–de Haas (SdH) oscillations inform complex quantum transport phenomena that are not limited by the ground state characteristics and have facilitated extensive explorations of quantum and topological interest in two- and three-dimensional materials. Here, in elemental metal Cr with two incommensurately superposed lattices of ions and a spin-density-wave ground state, we reveal that the phases of several low-frequency SdH oscillations in σ xx (ρ xx ) and σ yy (ρ yy ) are no longer identical but opposite. These relationships contrast with the SdH oscillations from normal cyclotron orbits that maintain identical phases between σ xx (ρ xx ) and σ yy (ρ yy ) . We trace the origin of the low-frequency SdH oscillations to quantum interference effects arising from the incommensurate orbits of Cr’s superposed reciprocal lattices and explain the observed π-phase shift by the reconnection of anisotropic joint open and closed orbits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

QUASI-PERIODIC WIGGLES OF MICROWAVE ZEBRA STRUCTURES IN A SOLAR FLARE

Quasi-periodic wiggles of microwave zebra pattern (ZP) structures with periods ranging from about 0.5 s to 1.5 s are found in an X-class solar flare on 2006 December 13 at the 2.6-3.8 GHz with the Chinese Solar Broadband Radio Spectrometer (SBRS/Huairou). Periodogram and correlation analysis show that the wiggles have two to three significant periodicities and are almost in phase between stripes at different frequencies. The Alfvén speed estimated from the ZP structures is about 700 km s{sup –1}. We find the spatial size of the wave-guiding plasma structure to be about 1 Mm with a detected period of about 1 s. This suggests that the ZP wiggles can be associated with the fast magnetoacoustic oscillations in the flaring active region. The lack of a significant phase shift between wiggles of different stripes suggests that the ZP wiggles are caused by a standing sausage oscillation.

79 ASTRONOMY AND ASTROPHYSICS↗

Three-body continuum states in a microscopic cluster model

We propose a microscopic approach to three-body continuum states in the hyperspherical formalism. The A-nucleon wave functions are defined in the generator coordinate method, based on a three-cluster approximation of the system. We develop a semianalytical treatment of the matrix elements, limited to s clusters. This allows a fast calculation, as well as a direct interpretation of the wave functions, in terms of nucleon exchanges. We apply the method to the {alpha}+n+n three-body phase shifts and confirm the existence of broad structures in the 0{sup +} and 1{sup -} partial waves at low energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-hadron systems in lattice QCD

Lattice QCD is currently entering the stage when it can usefully be applied to systems of multiple hadrons. I briefly review the status of recent calculations of scattering parameters in the two hadron sector and discuss recent calculations of systems composed of many mesons or baryons. In the mesonic case, the NPLQCD collaboration has continued its study of systems of up to twelve pions or kaons and have computed the effect of such a hadronic medium on the static quark potential. High statistics calculations on anisotropic lattices have allowed for precision extraction of the energies and scattering phase shifts of various two baryon systems and, for the first time, the energies of certain three baryon systems have been computed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗