Market optimization and technoeconomic analysis of hydrogen-electricity coproduction systems

Decarbonization efforts across North America, Europe, and beyond rely on variable renewable energy sources such as wind and solar, as well as alternative fuels, such as hydrogen, to support the sustainable energy transition. These advancements have prompted a need for more flexibility in the electric grid to complement non-dispatchable energy sources and increased demand from electrification. Integrated energy systems are well suited to provide this flexibility, but conventional technoeconomic modeling paradigms neglect the time-varying dynamic nature of the grid and thus undervalue resource flexibility. In this work, we develop a computational optimization framework for dynamic market-based technoeconomic comparison of integrated energy systems that coproduce low-carbon electricity and hydrogen (e.g., solid oxide fuel cells, solid oxide electrolysis) against technologies that only produce electricity (e.g., natural gas combined cycle with carbon capture) or only produce hydrogen. Our framework starts with rigorous physics-based process models, built in the open-source Institute for the Design of Advanced Energy Systems (IDAES) modeling and optimization platform, for six energy process concepts. Using these rigorous models and a workflow to optimally design each technology, the framework is shown to be capable of evaluating new and emerging technologies in varying energy markets under a plethora of future scenarios (i.e., renewables penetration, carbon tax, etc.). Ultimately, our framework finds that solid oxide fuel cell-based coproduction systems achieve positive profits for 85% of the analyzed market scenarios. From these market optimization results, we use multivariate linear regression (R 2 values up to 0.99) to determine which electricity price statistics are most significant to predict the optimized annual profit of each system. The proposed framework provides a powerful tool for directly comparing flexible, multi-product energy process concepts to help discern optimal technology and integration options.

08 HYDROGEN↗

Preliminary investigations on the determination of three-dimensional dose distributions using scintillator blocks and optical tomography

Purpose: Clinical QA in teletherapy as well as the characterization of experimental radiation sources for future medical applications requires effective methods for measuring three-dimensional (3D) dose distributions generated in a water-equivalent medium. Current dosimeters based on ionization chambers, diodes, thermoluminescence detectors, radiochromic films, or polymer gels exhibit various drawbacks: High quality 3D dose determination is either very sophisticated and expensive or requires high amounts of effort and time for the preparation or read out. New detectors based on scintillator blocks in combination with optical tomography are studied, since they have the potential to facilitate the desired cost-effective, transportable, and long-term stable dosimetry system that is able to determine 3D dose distributions with high spatial resolution in a short time.Methods: A portable detector prototype was set up based on a plastic scintillator block and four digital cameras. During irradiation the scintillator emits light, which is detected by the fixed cameras. The light distribution is then reconstructed by optical tomography, using maximum-likelihood expectation maximization. The result of the reconstruction approximates the 3D dose distribution. First performance tests of the prototype using laser light were carried out. Irradiation experiments were performed with ionizing radiation, i.e., bremsstrahlung (6 to 21 MV), electrons (6 to 21 MeV), and protons (68 MeV), provided by clinical and research accelerators.Results: Laser experiments show that the current imaging properties differ from the design specifications: The imaging scale of the optical systems is position dependent, ranging from 0.185 mm/pixel to 0.225 mm/pixel. Nevertheless, the developed dosimetry method is proven to be functional for electron and proton beams. Induced radiation doses of 50 mGy or more made 3D dose reconstructions possible. Taking the imaging properties into account, determined dose profiles are in agreement with reference measurements. An inherent drawback of the scintillator is the nonlinear light output for high stopping-power radiation due to the quenching effect. It impacts the depth dose curves measured with the dosimeter. For single Bragg peak distributions this leads to a peak to plateau ratio of 2.8 instead of 4.5 for the reference ionization chamber measurement. Furthermore, the transmission of the clinical bremsstrahlung beams through the scintillator leads to the saturation of one camera, making dose reconstructions in that case presently not feasible.Conclusions: It is shown that distributions of scintillation light generated by proton or electron beams can be reconstructed by the dosimetry system within minutes. The quenching apparent for proton irradiation, and the yet not precisely determined position dependency of the imaging scale, require further investigation and corrections. Upgrading the prototype with larger or inorganic scintillators would increase the detectable proton and electron energy range. The presented results show that the determination of 3D dose distributions using scintillator blocks and optical tomography is a promising dosimetry method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of probe displacement to the thermal resolution limit in photonic force microscopy using a miniature quadrant photodetector

A photonic force microscope comprises of an optically trapped micro-probe and a position detection system to track the motion of the probe. Signal collection for motion detection is often carried out using the backscattered light off the probe-however, this mode has problems of low S/N due to the small backscattering cross sections of the micro-probes typically used. The position sensors often used in these cases are quadrant photodetectors. To ensure maximum sensitivity of such detectors, it would help if the detector size matched with the detection beam radius after the condenser lens (which for backscattered detection would be the trapping objective itself). To suit this condition, we have used a miniature displacement sensor whose dimensions makes it ideal to work with 1:1 images of micrometer-sized trapped probes in the backscattering detection mode. The detector is based on the quadrant photo-integrated chip in the optical pick-up head of a compact disc player. Using this detector, we measured absolute displacements of an optically trapped 1.1 {mu}m probe with a resolution of {approx}10 nm for a bandwidth of 10 Hz at 95% significance without any sample or laser stabilization. We characterized our optical trap for different sized probes by measuring the power spectrum for each probe to 1% accuracy, and found that for 1.1 {mu}m diameter probes, the noise in our position measurement matched the thermal resolution limit for averaging times up to 10 ms. We also achieved a linear response range of around 385 nm with cross talk between axes {approx_equal}4% for 1.1 {mu}m diameter probes. The detector has extremely high bandwidth (few MHz) and low optical power threshold-other factors that can lead to its widespread use in photonic force microscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observations of narrow bipolar events reveal how lightning is initiated in thunderstorms

A long-standing but fundamental question in lightning studies concerns how lightning is initiated inside storms, given the absence of physical conductors. The issue has revolved around the question of whether the discharges are initiated solely by conventional dielectric breakdown or involve relativistic runaway electron processes. Here we report observations of a relatively unknown type of discharge, called fast positive breakdown, that is the cause of high-power discharges known as narrow bipolar events. We find that the breakdown has a wide range of strengths and is the initiating event of numerous lightning discharges. It appears to be purely dielectric in nature and to consist of a system of positive streamers in a locally intense electric field region. It initiates negative breakdown at the starting location of the streamers, which leads to the ensuing flash. The observations show that many or possibly all lightning flashes are initiated by fast positive breakdown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multipoint vibrometry with dynamic and static holograms

We report on two multipoint vibrometers with user-adjustable position of the measurement spots. Both systems are using holograms for beam deflection. The measurement is based on heterodyne interferometry with a frequency difference of 5 MHz between reference and object beam. One of the systems uses programmable positioning of the spots in the object volume but is limited concerning the light efficiency. The other system is based on static holograms in combination with mechanical adjustment of the measurement spots and does not have such a general efficiency restriction. Design considerations are given and we show measurement results for both systems. In addition, we analyze the sensitivity of the systems which is a major limitation compared to single point scanning systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new APDS approach - alarm processing based on alarm prioritization - 201

We take for granted that the advances in technology bring improvements to the conditions in which humans perform activities associated to them. Is that the case for digital alarm systems in nuclear power plants? The answer is not that simple. A review of the related literature, shows that still, the single most significant problem with alarm systems, is the large number of alarm messages presented to the operator at once. This is an issue that affects analog I and C control rooms with conventional annunciators and gets aggravated in digital I and C based control rooms. Digital alarm systems present the alarms in the form of lists in computer screens. This kind of presentation forces the operator to scroll or navigate pages to review the active alarms. Also, the alarm lists do not allow the operator to apply the pattern recognition practices acquired during training when using with fixed position alarm systems. An Alarm Processing and Diagnostic System (APDS) facilitates the alarm monitoring task by applying alarm reduction techniques based on alarm priorities. It allows the operators to focus on the most important alarms during plant upsets. A new generation of APDS should be based in an improved alarm analysis methodology. To develop such methodology, Tecnatom reviewed applicable standards and our own alarm analysis experiences. This paper documents the process and conclusions of the methodology development. (authors)

42 ENGINEERING↗

Fusion of {sup28}Si + {sup28,30}Si: Different Trends at Sub-Barrier Energies

Background: The fusion excitation function of the system Si-28 + Si-28 at energies near and below the Coulomb barrier is known only down to similar or equal to 15 mb. This precludes any information on both coupling effects on sub-barrier cross sections and the possible appearance of hindrance. For Si-28 + Si-30 even if the fusion cross section is measured down to similar or equal to 50 mu b, the evidence of hindrance is marginal. Both systems have positive fusion Q values. While Si-28 has a deformed oblate shape, Si-30 is spherical. Purpose: We investigate 1. the possible influence of the different structure of the two Si isotopes on the fusion excitation functions in the deep sub-barrier region and 2. whether hindrance exists in the Si + Si systems and whether it is strong enough to generate an S-factor maximum, thus allowing a comparison with lighter heavy-ion systems of astrophysical interest. Methods: Si-28 beams from the XTU Tandem accelerator of the INFN Laboratori Nazionali di Legnaro were used. The setup was based on an electrostatic beam separator, and fusion evaporation residues (ER) were detected at very forward angles. Angular distributions of ER were measured. Results: Fusion cross sections of Si-28 + Si-28 have been obtained down to similar or equal to 600 nb. The slope of the excitation function has a clear irregularity below the barrier, but no indication of a S-factor maximum is found. For Si-28 + Si-30 the previous data have been confirmed and two smaller cross sections have been measured down to similar or equal to 4 mu b. The trend of the S-factor reinforces the previous weak evidence of hindrance. Conclusions: The sub-barrier cross sections for Si-28 + Si-28 are overestimated by coupled-channels calculations based on a standard Woods-Saxon potential, except for the lowest energies. Calculations using the M3Y+repulsion potential are adjusted to fit the Si-28 + Si-28 and the existing Si-30 + Si-30 data. An additional weak imaginary potential (probably simulating the effect of the oblate Si-28 deformation) is required to fit the low-energy trend of Si-28 + Si-28. The parameters of these calculations are applied to predict the ion-ion potential for Si-28 + Si-30. Its cross sections are well reproduced by also including one-and successive two-neutron transfer channels, besides the low-lying surface excitations.

Montagnoli, G.↗

EPRI Demonstration of an Autonomous Site Characterization Vehicle - 20523

A substantial effort is applied in performing radiological characterization of structures and land areas during decommissioning of a nuclear facility. This includes multiple surveys of land areas and large structures to support eventual site release under the Multi Agency Survey and Site Investigation Manual (MARSSIM, Reference 1). These surveys are typically performed using manually delivered systems, which is time consuming and labor intensive. Radiological surveys intentionally follow a prescribed protocol with respect to areas covered, scan speeds, responses to elevated readings, required detector offsets, the need for repeat measurements, etc. Based on these attributes, combined with the repetitive effort of performing surveys over large areas, automation of radiological characterization techniques has a high potential to be successful and promises substantial benefit. EPRI has performed a project that resulted in the development and demonstration of an autonomous site characterization system. This EPRI project focused on building surfaces and the surfaces of large land areas as these configurations lend themselves more readily to automated survey. The project included: - Identification of the requirements for an autonomous site characterization system; - A survey of existing control systems that use automation to conduct characterization of structures and land areas. - As no fully adequate systems were identified, a complete system was developed that utilized commercially available detection and analysis systems and a self driving vehicle owned by EPRI. The system was demonstrated at the Kewaunee nuclear power plant site in the fall of 2019. The demonstration included: - Autonomous surveys of floor areas inside the Auxiliary Building at Kewaunee after manually controlled mapping of the survey areas. - For land areas, the vehicle autonomously surveyed areas using travel paths had been preprogrammed onto an internet available map of area. In this case, GPS coordinates from the preprogramming were used for navigation by the vehicles guidance system. This paper summarizes the characterization system development and system demonstration which will also be published in an EPRI report in the first half of 2020. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-J-236: Audiovisual Biofeedback Improves Breath-Hold Lung Tumor Position Reproducibility Measured with 4D MRI

Purpose: Audiovisual biofeedback breath-hold (AVBH) was employed to reproduce tumor position on inhale and exhale breath-holds for 4D tumor information. We hypothesize that lung tumor position will be more consistent using AVBH compared with conventional breath-hold (CBH). Methods: Lung tumor positions were determined for seven lung cancer patients (age: 25 – 74) during to two separate 3T MRI sessions. A breathhold training session was performed prior to the MRI sessions to allow patients to become comfortable with AVBH and their exhale and inhale target positions. CBH and AVBH 4D image datasets were obtained in the first MRI session (pre-treatment) and the second MRI session (midtreatment) within six weeks of the first session. Audio-instruction (MRI: Siemens Skyra) in CBH and verbal-instruction (radiographer) in AVBH were used. A radiation oncologist contoured the lung tumor using Eclipse (Varian Medical Systems); tumor position was quantified as the centroid of the contoured tumor after rigid registration based on vertebral anatomy across two MRI sessions. CBH and AVBH were compared in terms of the reproducibility assessed via (1) the difference between the two exhale positions for the two sessions and the two inhale positions for the sessions. (2) The difference in amplitude (exhale to inhale) between the two sessions. Results: Compared to CBH, AVBH improved the reproducibility of two exhale (or inhale) lung tumor positions relative to each other by 33%, from 6.4±5.3 mm to 4.3±3.0 mm (p=0.005). Compared to CBH, AVBH improved the reproducibility of exhale and inhale amplitude by 66%, from 5.6±5.9 mm to 1.9±1.4 mm (p=0.005). Conclusions: This study demonstrated that audiovisual biofeedback can be utilized for improving the reproducibility of breath-hold lung tumor position. These results are advantageous towards achieving more accurate emerging radiation treatment planning methods, in addition to imaging and treatment modalities utilizing breath-hold procedures.

60 APPLIED LIFE SCIENCES↗

Measurement of time delays in gated radiotherapy for realistic respiratory motions

Purpose: Gated radiotherapy is used to reduce internal motion margins, escalate target dose, and limit normal tissue dose; however, its temporal accuracy is limited. Beam-on and beam-off time delays can lead to treatment inefficiencies and/or geographic misses; therefore, AAPM Task Group 142 recommends verifying the temporal accuracy of gating systems. Many groups use sinusoidal phantom motion for this, under the tacit assumption that use of sinusoidal motion for determining time delays produces negligible error. The authors test this assumption by measuring gating time delays for several realistic motion shapes with increasing degrees of irregularity. Methods: Time delays were measured on a linear accelerator with a real-time position management system (Varian TrueBeam with RPM system version 1.7.5) for seven motion shapes: regular sinusoidal; regular realistic-shape; large (40%) and small (10%) variations in amplitude; large (40%) variations in period; small (10%) variations in both amplitude and period; and baseline drift (30%). Film streaks of radiation exposure were generated for each motion shape using a programmable motion phantom. Beam-on and beam-off time delays were determined from the difference between the expected and observed streak length. Results: For the system investigated, all sine, regular realistic-shape, and slightly irregular amplitude variation motions had beam-off and beam-on time delays within the AAPM recommended limit of less than 100 ms. In phase-based gating, even small variations in period resulted in some time delays greater than 100 ms. Considerable time delays over 1 s were observed with highly irregular motion. Conclusions: Sinusoidal motion shapes can be considered a reasonable approximation to the more complex and slightly irregular shapes of realistic motion. When using phase-based gating with predictive filters even small variations in period can result in time delays over 100 ms. Clinical use of these systems for patients with highly irregular patterns of motion is not advised due to large beam-on and beam-off time delays.

60 APPLIED LIFE SCIENCES↗

TU-CD-BRD-00: Incident Learning / RO-ILS

It has long been standard practice in radiation oncology to report internally when a patient’s treatment has not gone as planned and to report events to regulatory agencies when legally required. Most potential errors are caught early and never affect the patient. Quality assurance steps routinely prevent errors from reaching the patient, and these “near misses” are much more frequent than treatment errors. A growing number of radiation oncology facilities have implemented incident learning systems to report and analyze both errors and near misses. Using the term “incident learning” instead of “event reporting” emphasizes the need to use these experiences to change the practice and make future errors less likely and promote an educational, non-punitive environment. There are challenges in making such a system practical and effective. Speakers from institutions of different sizes and practice environments will share their experiences on how to make such a system work and what benefits their clinics have accrued. Questions that will be addressed include: How to create a system that is easy for front line staff to access How to motivate staff to report How to promote the system as positive and educational and not punitive or demeaning How to organize the team for reviewing and responding to reports How to prioritize which reports to discuss in depth How not to dismiss the rest How to identify underlying causes How to design corrective actions and implement change How to develop useful statistics and analysis tools How to coordinate a departmental system with a larger risk management system How to do this without a dedicated quality manager Some speakers’ experience is with in-house systems and some will share experience with the AAPM/ASTRO national Radiation Oncology Incident Learning System (RO-ILS). Reports intended to be of value nationally need to be comprehensible to outsiders; examples of useful reports will be shown. There will be ample time set aside for audience members to contribute to the discussion. Learning Objectives: Learn how to promote the use of an incident learning system in a clinic. Learn how to convert “event reporting” into “incident learning”. See examples of practice changes that have come out of learning systems. Learn how the RO-ILS system can be used as a primary internal learning system. Learn how to create succinct, meaningful reports useful to outside readers. Gary Ezzell chairs the AAPM committee overseeing RO-ILS and has received an honorarium from ASTRO for working on the committee reviewing RO-ILS reports. Derek Brown is a director of http://TreatSafely.org . Brett Miller has previously received travel expenses and an honorarium from Varian. Phillip Beron has nothing to report.

60 APPLIED LIFE SCIENCES↗

TU-CD-BRD-01: Making Incident Learning Practical and Useful: Challenges and Previous Experiences

It has long been standard practice in radiation oncology to report internally when a patient’s treatment has not gone as planned and to report events to regulatory agencies when legally required. Most potential errors are caught early and never affect the patient. Quality assurance steps routinely prevent errors from reaching the patient, and these “near misses” are much more frequent than treatment errors. A growing number of radiation oncology facilities have implemented incident learning systems to report and analyze both errors and near misses. Using the term “incident learning” instead of “event reporting” emphasizes the need to use these experiences to change the practice and make future errors less likely and promote an educational, non-punitive environment. There are challenges in making such a system practical and effective. Speakers from institutions of different sizes and practice environments will share their experiences on how to make such a system work and what benefits their clinics have accrued. Questions that will be addressed include: How to create a system that is easy for front line staff to access How to motivate staff to report How to promote the system as positive and educational and not punitive or demeaning How to organize the team for reviewing and responding to reports How to prioritize which reports to discuss in depth How not to dismiss the rest How to identify underlying causes How to design corrective actions and implement change How to develop useful statistics and analysis tools How to coordinate a departmental system with a larger risk management system How to do this without a dedicated quality manager Some speakers’ experience is with in-house systems and some will share experience with the AAPM/ASTRO national Radiation Oncology Incident Learning System (RO-ILS). Reports intended to be of value nationally need to be comprehensible to outsiders; examples of useful reports will be shown. There will be ample time set aside for audience members to contribute to the discussion. Learning Objectives: Learn how to promote the use of an incident learning system in a clinic. Learn how to convert “event reporting” into “incident learning”. See examples of practice changes that have come out of learning systems. Learn how the RO-ILS system can be used as a primary internal learning system. Learn how to create succinct, meaningful reports useful to outside readers. Gary Ezzell chairs the AAPM committee overseeing RO-ILS and has received an honorarium from ASTRO for working on the committee reviewing RO-ILS reports. Derek Brown is a director of http://TreatSafely.org . Brett Miller has previously received travel expenses and an honorarium from Varian. Phillip Beron has nothing to report.

60 APPLIED LIFE SCIENCES↗

TU-CD-BRD-02: Henry Ford Hospital System Experience, with Focus On Motivating and Reviewing

It has long been standard practice in radiation oncology to report internally when a patient’s treatment has not gone as planned and to report events to regulatory agencies when legally required. Most potential errors are caught early and never affect the patient. Quality assurance steps routinely prevent errors from reaching the patient, and these “near misses” are much more frequent than treatment errors. A growing number of radiation oncology facilities have implemented incident learning systems to report and analyze both errors and near misses. Using the term “incident learning” instead of “event reporting” emphasizes the need to use these experiences to change the practice and make future errors less likely and promote an educational, non-punitive environment. There are challenges in making such a system practical and effective. Speakers from institutions of different sizes and practice environments will share their experiences on how to make such a system work and what benefits their clinics have accrued. Questions that will be addressed include: How to create a system that is easy for front line staff to access How to motivate staff to report How to promote the system as positive and educational and not punitive or demeaning How to organize the team for reviewing and responding to reports How to prioritize which reports to discuss in depth How not to dismiss the rest How to identify underlying causes How to design corrective actions and implement change How to develop useful statistics and analysis tools How to coordinate a departmental system with a larger risk management system How to do this without a dedicated quality manager Some speakers’ experience is with in-house systems and some will share experience with the AAPM/ASTRO national Radiation Oncology Incident Learning System (RO-ILS). Reports intended to be of value nationally need to be comprehensible to outsiders; examples of useful reports will be shown. There will be ample time set aside for audience members to contribute to the discussion. Learning Objectives: Learn how to promote the use of an incident learning system in a clinic. Learn how to convert “event reporting” into “incident learning”. See examples of practice changes that have come out of learning systems. Learn how the RO-ILS system can be used as a primary internal learning system. Learn how to create succinct, meaningful reports useful to outside readers. Gary Ezzell chairs the AAPM committee overseeing RO-ILS and has received an honorarium from ASTRO for working on the committee reviewing RO-ILS reports. Derek Brown is a director of http://TreatSafely.org . Brett Miller has previously received travel expenses and an honorarium from Varian. Phillip Beron has nothing to report.

60 APPLIED LIFE SCIENCES↗

TU-CD-BRD-03: UCSD Experience, with Focus On Implementing Change

It has long been standard practice in radiation oncology to report internally when a patient’s treatment has not gone as planned and to report events to regulatory agencies when legally required. Most potential errors are caught early and never affect the patient. Quality assurance steps routinely prevent errors from reaching the patient, and these “near misses” are much more frequent than treatment errors. A growing number of radiation oncology facilities have implemented incident learning systems to report and analyze both errors and near misses. Using the term “incident learning” instead of “event reporting” emphasizes the need to use these experiences to change the practice and make future errors less likely and promote an educational, non-punitive environment. There are challenges in making such a system practical and effective. Speakers from institutions of different sizes and practice environments will share their experiences on how to make such a system work and what benefits their clinics have accrued. Questions that will be addressed include: How to create a system that is easy for front line staff to access How to motivate staff to report How to promote the system as positive and educational and not punitive or demeaning How to organize the team for reviewing and responding to reports How to prioritize which reports to discuss in depth How not to dismiss the rest How to identify underlying causes How to design corrective actions and implement change How to develop useful statistics and analysis tools How to coordinate a departmental system with a larger risk management system How to do this without a dedicated quality manager Some speakers’ experience is with in-house systems and some will share experience with the AAPM/ASTRO national Radiation Oncology Incident Learning System (RO-ILS). Reports intended to be of value nationally need to be comprehensible to outsiders; examples of useful reports will be shown. There will be ample time set aside for audience members to contribute to the discussion. Learning Objectives: Learn how to promote the use of an incident learning system in a clinic. Learn how to convert “event reporting” into “incident learning”. See examples of practice changes that have come out of learning systems. Learn how the RO-ILS system can be used as a primary internal learning system. Learn how to create succinct, meaningful reports useful to outside readers. Gary Ezzell chairs the AAPM committee overseeing RO-ILS and has received an honorarium from ASTRO for working on the committee reviewing RO-ILS reports. Derek Brown is a director of http://TreatSafely.org . Brett Miller has previously received travel expenses and an honorarium from Varian. Phillip Beron has nothing to report.

60 APPLIED LIFE SCIENCES↗

TU-CD-BRD-04: UCLA Experience, with Focus On Developing Metrics and Using RO-ILS

It has long been standard practice in radiation oncology to report internally when a patient’s treatment has not gone as planned and to report events to regulatory agencies when legally required. Most potential errors are caught early and never affect the patient. Quality assurance steps routinely prevent errors from reaching the patient, and these “near misses” are much more frequent than treatment errors. A growing number of radiation oncology facilities have implemented incident learning systems to report and analyze both errors and near misses. Using the term “incident learning” instead of “event reporting” emphasizes the need to use these experiences to change the practice and make future errors less likely and promote an educational, non-punitive environment. There are challenges in making such a system practical and effective. Speakers from institutions of different sizes and practice environments will share their experiences on how to make such a system work and what benefits their clinics have accrued. Questions that will be addressed include: How to create a system that is easy for front line staff to access How to motivate staff to report How to promote the system as positive and educational and not punitive or demeaning How to organize the team for reviewing and responding to reports How to prioritize which reports to discuss in depth How not to dismiss the rest How to identify underlying causes How to design corrective actions and implement change How to develop useful statistics and analysis tools How to coordinate a departmental system with a larger risk management system How to do this without a dedicated quality manager Some speakers’ experience is with in-house systems and some will share experience with the AAPM/ASTRO national Radiation Oncology Incident Learning System (RO-ILS). Reports intended to be of value nationally need to be comprehensible to outsiders; examples of useful reports will be shown. There will be ample time set aside for audience members to contribute to the discussion. Learning Objectives: Learn how to promote the use of an incident learning system in a clinic. Learn how to convert “event reporting” into “incident learning”. See examples of practice changes that have come out of learning systems. Learn how the RO-ILS system can be used as a primary internal learning system. Learn how to create succinct, meaningful reports useful to outside readers. Gary Ezzell chairs the AAPM committee overseeing RO-ILS and has received an honorarium from ASTRO for working on the committee reviewing RO-ILS reports. Derek Brown is a director of http://TreatSafely.org . Brett Miller has previously received travel expenses and an honorarium from Varian. Phillip Beron has nothing to report.

60 APPLIED LIFE SCIENCES↗

X-ray position detector and implementation in a mirror pointing servo system

An X-ray beam position and stability detector is provided having a first metal blade collinear with a second metal blade, where an edge of the first metal blade is opposite an edge of the second metal blade, where the first metal blade edge and the second metal blade edge are disposed along a centerline with respect to each other, where the metal blades are capable of photoelectron emission when exposed to an x-ray beam, a metal coating on the metal blades that is capable of enhancing the photoelectron emission, or suppressing energy-resonant contaminants, or enhancing the photoelectron emission and suppressing energy-resonant contaminants, a background shielding element having an electrode capable of suppressing photoelectron emission from spurious x-rays not contained in an x-ray beam of interest, and a photoelectron emission detector having an amplifier capable of detecting the photoelectron emission as a current signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the ProtoDUNE Horizontal-Drift position reconstruction using a laser system

Forthcoming in the next decade of neutrino physics advancements is the construction of the Deep Underground Neutrino Experiment (DUNE), a long baseline neutrino oscillation experiment which has the potential to answer fundamental questions such as why there is more matter than antimatter in the universe, and ultimately why we exist at all. A prototype of this experiment, ProtoDUNE, sits in a charged particle test beam at the European Organization for Nuclear Research (CERN) and uses Liquid Argon time projection chambers to image interactions of these particles. ProtoDUNE Single-Phase (ProtoDUNESP) had positively charged hadrons as well as positrons in its initial 2018 beam data run. Because ProtoDUNE is a surface-based time projection chamber, it experiences a constant influx of cosmic rays. These cosmic rays ionize the liquid argon within the detector, resulting in an accumulation of slow moving positive ions towards the cathode. This local charge distribution results in electric field non uniformities, which can have a significant effect on the accuracy of the event reconstruction. This paper outlines a monte carlo simulation study which adapts methodology from the MicroBooNE experiment, another neutrino oscillation experiment, to derive electric field correction maps which can correct for distortions of the electric field within the detector. These correction maps accurately estimate the electric field throughout the detector volume and correct for uncertainties in reconstructed event data enabling for physics discoveries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 09: Impact of the distance of reflective markers from linac isocenter on the positional accuracy of an infrared tracking system

Purpose: The HexaPOD™ six degree of freedom couchtop is equipped with an optical tracking system, consisting of a stereoscopic camera and a reference frame (RF) carrying infrared reflective markers. The manufacturer recommends placing the RF within 50 cm from linac isocenter (ISO), which is a serious limitation since the RF does not fit around the shoulders of most brain patients. This study quantifies the impact of extended RF distances from ISO on positional accuracy. Methods: An in-house tool with an estimated resolution of 0.3 mm and 0.1° was used. It is a large cube and a mathematical model of HexaPOD motion to determine the intersection of room lasers with the ruled cube edges. Combinations of translations (±1 and ±3 cm) and rotations (±2.5°) were executed on two HexaPOD couchtops for multiple RF distances from ISO (35 to 77 cm). For each combination, ten laser readings were fed into a least squares algorithm to determine the executed translations and rotations while minimizing operator reading errors. Results: The usable tracking volume is up to an RF distance of 82 cm from ISO. Positional accuracy of the HexaPOD/iGuide system is 0.6 mm and 0.1° (95% confidence). Positional accuracy variations versus RF distance from ISO are statistically insignificant (p = 0.05). Our results generally confirm recent internal estimates by the manufacturer (for future release). Conclusions: RF distances up to 77 cm from ISO are clinically acceptable, provided performing a patient safety study with a verification scan.

60 APPLIED LIFE SCIENCES↗