Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Coordinated net-load management

A management device includes at least one processor communicatively coupled to at least one energy resource controller controlling at least one energy resource and to at least one deferrable load controller controlling power to at least one deferrable load. The is configured to receive an indication, determined based on a frequency value of an electrical network and a nominal frequency value, that a frequency anomaly event has occurred. Responsive to receiving the indication that the frequency anomaly event has occurred, the processor is also configured to determine, for at least one of the energy resource and the deferrable load, based on the frequency value, the nominal frequency value, and a power value of the electrical network, a respective power command, and cause at least one of the at least one energy resource and the at least one deferrable load to modify operation based on the respective power command.

42 ENGINEERING↗

Dissimilar joining of ZEK100 and AA6022 for automotive application

Mg and Al joining is problematic due to different high temperature flow characteristics that often results in weld defects and brittle intermetallic compounds (IMC). We present process development on lap joining of 1.27 mm 6022 (top sheet) and 1.5mm ZEK100 (bottom sheet) for an automotive door application. We conducted process development in linear welding using power control mode (modulating torque and spindle speed) with multiple tool designs, and welding parameters. Process variables were correlated to joint micro-structure and mechanical properties. A 2D computational model was created to understand the failure mechanism and contribution of mechanical interlocking towards joint strength. For a thin (< 2 mm) automotive sheet with softer material as a bottom sheet, adequate control of process variables is critical to maintain weld stability and avoid excessive IMC layer at the interface. A combination of mechanical anchoring and metallurgical reaction is likely responsible for bonding.

Das, Hrishikesh↗

Peak Power Reduction for HVAC Operations in Multi-unit Commercial Buildings

The load profiles of most commercial consumers are characterized by brief periods of very high power consumption followed by intervals of relatively lower demand. In order to flatten commercial load profiles, several power utilities in addition to billing energy consumption, levy a demand charge (DC) on the monthly peak demand. In this work, we consider the problem of joint optimization of energy costs (EC) and DC incurred by a multi-unit building which follows a demand response (DR) program. Despite the non-linear structure of the problem, we show how the optimal solutions can be obtained efficiently using linear programming. We evaluate the performance of the proposed power control scheme for various climate zones in the US. We show that depending on the ambient conditions and the prescribed tariff structure, our strategy can result in savings of up to nearly 19% compared to the baseline.

Raza Naqvi, Syed A.↗

Coordinated net-load management

A management device includes at least one processor communicatively coupled to at least one energy resource controller controlling at least one energy resource and to at least one deferrable load controller controlling power to at least one deferrable load. The is configured to receive an indication, determined based on a frequency value of an electrical network and a nominal frequency value, that a frequency anomaly event has occurred. Responsive to receiving the indication that the frequency anomaly event has occurred, the processor is also configured to determine, for at least one of the energy resource and the deferrable load, based on the frequency value, the nominal frequency value, and a power value of the electrical network, a respective power command, and cause at least one of the at least one energy resource and the at least one deferrable load to modify operation based on the respective power command.

Lundstrom, Blake Richard↗

Evaluation of Communication Issues in Primal-Dual-Based Distributed Energy Resource Management Systems (DERMS): Preprint

With the increasing adoption of distributed energy resources (DERs) in distribution networks, DERMS is becoming an attractive option to coordinate the control of DERs, especially primal-dual-based DERMS which is a well-developed class of them. In order to help lower the uncertainty in commercializing them, we evaluate and find the upper limits of severity for some common issues that can occur within the communication systems on which a primal-dual-based DERMS relies on; these include packet losses, link failures, and delays. This information can help a DERMS operator decide on the specifications for the communication infrastructure it will invest in for the DERMS. Our evaluation is based on numerical simulations of a real-world feeder with around 2,000 nodes and a DERMS that controls 163 PV generators and 140 energy storage batteries. In general, we found that the DERMS becomes less resistant to communication issues as the information flows closer to the DERs implementing the controllable power injections.

communication delay↗

Test facility for fission chamber assemblies - 239

The Institution -Project Center ITER- with participation of the National Research Nuclear University MEPhI are developing the neutron diagnostics -Divertor Neutron Flux Monitor- (DNFM) for the International Thermonuclear Experimental Reactor (ITER). This diagnostics shall ensure measurement of the total neutron yield and ITER fusion power. Assemblies of fission chambers (FC) with different fissile materials and sensitivities are planned to be used for the neutron flux measurement. Study of fission chambers characteristics and acceptance testing of the diagnostic system will be carried out at the testing facility of the neutronic laboratory of the 'TRINITI' Institute. The facility includes: compact powerful neutron generator with the power, control and monitoring system; remote handling system for FCs positioning and movement; novel three channels data acquisition and processing system. Each acquisition channel contains some measuring circuits with signal processing. This set of circuits provides neutron flux measurement in the range of at least 10 decades for each single FC. Data acquisition and processing system features are: signal digitizing with sample rate up to 125 MHz; real time data processing with computation and data update cycle from 0.1 ms. This paper examines the structure, composition and specification of the test facility. Application software, hardware solutions and the results of fission chambers prototypes tests are discussed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resonance Self-shielding Impact on Neutron Spectrum Determination for Missouri S and T Reactor

Neutron Activation Analysis is a useful technique for characterizing the neutron flux at nuclear facilities. It involves irradiating samples to produce unstable isotopes, which enables qualitative and quantitative analyses of unknown samples. In the process, samples are bombarded with neutrons; new elements then become radioactive isotopes due to absorption of neutrons. These emit different amounts of gamma energy during the decay process, and gamma rays are counted using HPGe. Each reaction product has a known half-life and cross-section, and by measuring the amount of gamma radiation energy emitted from a radioactive isotope, it is possible to identify the isotope and activity. However, the neutron spectrum is not precise or representative of the actual neutron environment because of the self-shielding effect. This occurs with large samples that have large cross-sections or thicknesses in the resonance range of the neutron flux spectrum. Several methods have been used to mitigate this problem, such as thinning or diluting alloys samples, calculating the self-shielding factor for each material, and generating a corrected library for the unfolding procedure code. The Missouri University of Science and Technology Reactor (MSTR) is a pool-type research reactor that operates up to 200 kW. It uses light-water for both moderation and natural convective heat removal. The reactor core consists of 15 fuel elements positioned in a 9 x 6 aluminum grid plate, with four elements used for reactor power control. The fuel element is 19.75% low enriched uranium in 18 curved fuel plates. The reactor has seen various configurations starting with configuration designation 101W and subsequent reconfiguration increases the numeric designation by 1. The current configuration, 120W, was implemented in 2010. The new configuration provides more in-core locations for activation experiments and uses more fuel elements than previous ones. One of the irradiation locations in the MSTR core is the source holder. It is desired to improve the documentation of neutronic characteristics of the MSTR which are cardinal to experiments supported by the facility. One of these characteristics is the neutron spectrum at various locations in the reactor. Successful efforts yielded the neutron spectrum at a known location through the unfolding of the activity of irradiated foils. The purpose of this current study is to investigate the impact of resonance self-shielding of some of the activated foils on the determined spectrum.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Capability-Coordinated Frequency Control Scheme of a Virtual Power Plant with Renewable Energy Sources

Growing trends in the deployment of inverter-based renewable energy will decrease the inertia and frequency control capability of electric power systems by replacing conventional power plants; thus, the frequency of future power systems might be dynamic. This study proposes a capability-coordinated frequency control (CCFC) scheme of a virtual power plant (VPP) including adjustable-speed pumped storage hydropower (AS-PSH), a wind power plant (WPP), and an energy storage system to support the frequency nadir and reduce the steady-state error of system frequency. The CCFC scheme is based on a hierarchical-control structure in which a CCFC organises the output of local frequency control units. To support the frequency nadir, the CCFC dispatches weighted frequency errors that are proportional to the available headroom of the units; thus, the errors are forwarded separately with a system frequency error to the primary control loop of each unit and thereby arrest the frequency nadir at a higher value than a system without the CCFC. To reduce the steady-state error of the system frequency, the CCFC determines a partial active power command by additionally feeding an integrator of the CCFC with a modified frequency error that depends on the unit with the largest control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model predictive control system and method for integrated gasification combined cycle power generation

Control system and method for controlling an integrated gasification combined cycle (IGCC) plant are provided. The system may include a controller coupled to a dynamic model of the plant to process a prediction of plant performance and determine a control strategy for the IGCC plant over a time horizon subject to plant constraints. The control strategy may include control functionality to meet a tracking objective and control functionality to meet an optimization objective. The control strategy may be configured to prioritize the tracking objective over the optimization objective based on a coordinate transformation, such as an orthogonal or quasi-orthogonal projection. A plurality of plant control knobs may be set in accordance with the control strategy to generate a sequence of coordinated multivariable control inputs to meet the tracking objective and the optimization objective subject to the prioritization resulting from the coordinate transformation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of human machine interface (HMI) for digital control rooms in nuclear power plants - 119

The analog control systems of traditional Nuclear Power Plants (NPPs) are being replaced by digital systems due to the fact that analog Instrumentation and Control (I and C) systems are becoming obsolete and such technology is no longer supported by manufacturers. The purpose of this study is to jointly evaluate the performance of an operator with a Human Machine Interface (HMI) in a NPP digital control room ensuring the efficiency and the safety of the NPP. The validity and the accuracy of the operators' actions are the primary goals that have to be preserved through the emergence of the HMI based in digital systems. The transition from analog to digital control systems leads to a more advanced support of the NPP; Video Display Units (VDUs) are used for monitoring the state of the NPP while alarm systems help for directing attention. The operators, in order to monitor information from the different VDUs, have to switch attention between different screens (alarms systems and control systems). Therefore, a well-established HMI is a significant challenge to the overall operation of the NPP, that actually helps the operators to learn from the available information in detecting possible anomalies and making the right decisions, to ensure safety, and in parallel to diminish the human error. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization and controllability of radiated power via extrinsic impurity seeding in strongly negative triangularity plasmas in DIII-D

Experiments with extrinsic impurity seeding in strongly negative triangularity shapes in DIII-D achieved radiated power fractions (relative to input power) of up to ≈85% total radiation and ≈55% core radiation in steady-operating conditions. The relationship between core and total radiation was sensitive to impurity species and input power. Attempts to reach higher radiation levels via higher impurity flows resulted in radiative collapse disruptions. Nitrogen, neon, argon, and krypton were tested. Injection was by gas puffing, usually controlled by feeding back real-time estimates for core or total radiating fractions ($P_\textrm{rad} / P_\textrm{input}$). Argon and krypton were controlled by feeding back total radiating fraction, whereas neon was controlled by feeding back the core radiating fraction, due to the lower efficiency of neon as a divertor radiator. Nitrogen flows were pre-programmed. Reasonable total $P_\textrm{rad}$ control target following was achieved with argon or krypton. Control was more challenging with the neon/core radiation configuration, which was more prone to slow response and overshooting of the control target. Poor particle removal contributed to the control challenge: neon particle inventory within the last closed flux surface was roughly constant for up to 1 s (the longest duration tested) after neon injection was halted. However, separate experiments with laser-blow off of non-recycling impurities measured a short impurity confinement time, on the scale of the energy confinement time of ∼100 ms. Modeling with the Aurora impurity transport simulation matched experimental neon density profiles with full recycling (R = 1.0) and weak pumping but predicted rapid decreases in neon inventory if pumping were increased or recycling decreased. This indicates that changes outside the confined plasma (adding a well-placed pump) would improve controllability for all highly recycling species.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

HIGH POWER RF DISTRIBUTION AND CONTROL FOR MULTI-CAVITY CRYOMODULE TESTING

Qualification of the superconducting radio-frequency (SRF) cavities in the cryomodules for the accelerating performance needs to be done through high power processing. A four-way waveguide power distribution system with independent control of power outputs has been being developed for testing the multi-cavity cryomodules for the SNS linac. SNS is employing two types of cryomodules: one type with three medium beta six-cell cavities and the other with four high beta six-cell cavities. The cryomodule that is being manufactured as a spare and the new crymodules for the future power upgrade project (PUP) of SNS will be high beta types. The four-way power distribution with independently controlled power outputs was considered useful for powering all cavities at the same time with a klystron amplifier since the SNS test facility was configured for a single klystron operation. Since certain interaction between the cavities under severe field emission was suspected in existing cryomodules, this type of high power test can be valuable for characterization of SRF cavities. By implementing a vector modulator at each arm of the splitting system, the amplitudes and the phases of RF outputs can be controlled independently. This paper discusses the present status of the development.

Cryomodule↗

Control of Grid-Connected Multiport MV Power Electronics Energy Hub: Preprint

In this paper a new concept of multiport modular medium-voltage power electronics hub (M3PE-HUB) is introduced for future power grid. The goal for this project is to design, develop, and demonstrate foundational technologies and capabilities for multiport power electronics energy hubs that can serve as intelligent devices to coordinate and control several different sources and loads. In this paper, the architecture of the controller, the central controls, and its verification is presented.

controls↗

Coordinative Real-time Sub-Transmission Volt-VAr Control for Reactive Power Regulation between Transmission and Distribution Systems

This paper introduces an integrated voltage regulation approach to coordinate the Volt-VAr control between transmission and distribution systems. Distributed photovoltaic (PV) systems are aggregated as a virtual power plant (VPP). At the sub-transmission level, a Coordinated Real-time Sub-Transmission Volt-VAr Control Tool (CReST-VCT) is introduced to coordinate the operation of the shunt devices and the reactive power provided by the VPPs. The CReST-VCT uses an enhanced Volt-VAr control algorithm with weighted voltage control objects that include minimizing losses, maintaining the voltage within desirable levels, and minimizing the number of mechanical switching of shunt elements. The algorithm runs every 5 minutes and is solved using AC optimal power flow (OPF) solution technique. The outputs include the settings for each sub-transmission-level Volt-VAr control devices and the reactive power generation requirements for each VPP. Then, each VPP will run a distribution Volt-VAr control algorithm to select the PV inverters that provide the Volt-VAr control services considering the distribution network topology. The goal of the VPP reactive power control is to meet the transmission level service requirements while maintaining the voltage and line flow in the distribution system within limits. Each VPP will update its voltage regulation capacity every 5 minutes to allow the CReST-VCT to formulate the optimization problem for the next dispatch interval. The proposed tool is simulated on Duke Energy Carolina system to demonstrate the capability of providing voltage support service by dispatching of reactive power of distributed PV as VPP.

Ke, Xinda↗

Laboratory Evaluation of Federated, Hierarchical Controls for Distribution Power System Management: Preprint

The connection of more loads and distributed energy resources (DERs) to the distribution power system brings both challenges and opportunities to system operators. There are opportunities to aggregate flexible loads and DERs to provide transmission grid services, but the coordinated actions of DERs being managed by independent, third-party DER aggregators to support transmission system operations can present challenges. We developed a federated DER management architecture and control framework that aims to manage heterogeneous DERs to deliver reliable transmission grid services while respecting distribution system constraints. The controls include stochastic day-ahead optimization, model predictive control, and a simple real-time management scheme. We present simulation results obtained from a realistic laboratory test bed of federated controls managing DERs within a substation service area to make the substation net power follow the optimal net power determined by the day-ahead optimization based on cost and limiting reverse power flow.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed gradient descent for solving optimal power flow in radial networks

Node controllers and power distribution networks in accordance with embodiments of the invention enable distributed power control. One embodiment includes a node controller comprising a memory containing: a plurality of node operating parameters; and a plurality of node operating parameters describing operating parameters for a set of at least one node selected from the group consisting of at least one downstream node and at least one upstream node; wherein the processor is configured by the node controller application to: receive and store in memory a plurality of coordinator parameters describing operating parameters of a node coordinator by the network interface; and calculate updated node operating parameters using an iterative gradient projection process to determine updated node parameters using node operating parameters that describe operating parameters of node and operating parameters of the set of at least one node, where each iteration is determined by the coordinator parameters.

Gan, Lingwen↗

A VSM-Based DER Dispatch MINLP for Volt-VAR Control in Unbalanced Power Distribution Systems

This paper presents an optimal dispatch algorithm to coordinate customer-owned controllable loads and smart solar inverters with utility-owned voltage regulators and capacitors to meet voltage control objectives. The optimization problem is formulated as a mixed-integer nonlinear programming (MINLP) problem. A voltage sensitivity matrix (VSM) is used to linearize the effect of control actions on the voltage at customer nodes when solving the MINLP. The VSM is recalculated at each time step to improve the computational accuracy. Both discrete switching actions of the capacitor and VRs and the continuous adjustment of real and reactive power from load and smart inverters are considered in the MINLP volt-var problem formulation. The objective function minimizes the cost of all control actions and the magnitude of voltage fluctuations from the previous time period. Constraints ensure that the voltage at each node is maintained within ANSI limits and the feeder power factor is controlled within the desired range. The algorithm is tested using an actual 3-phase unbalanced distribution feeder model. Simulation results demonstrate that the proposed algorithm is computationally feasible on real circuits and improves voltage control while minimizing operational costs.

McEntee, Catie↗

Bifurcations, chaos and adaptive backstepping sliding mode control of a power system with excitation limitation

The bifurcation and Lyapunov exponent for a single-machine-infinite bus system with excitation model are carried out by varying the mechanical power, generator damping factor and the exciter gain, from which periodic motions, chaos and the divergence of system are observed respectively. From given parameters and different initial conditions, the coexisting motions are developed in power system. The dynamic behaviors in power system may switch freely between the coexisting motions, which will bring huge security menace to protection operation. Especially, the angle divergences due to the break of stable chaotic oscillation are found which causes the instability of power system. Finally, a new adaptive backstepping sliding mode controller is designed which aims to eliminate the angle divergences and make the power system run in stable orbits. Numerical simulations are illustrated to verify the effectivity of the proposed method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗