Exploring the connection between compact object mergers and fast X-ray transients

Context. The connection between compact object mergers and some extragalactic fast X-ray transients (FXRTs) has long been hypothesised but never ultimately established. Aims. In this work, we investigate two FXRTs, the LEIA X-ray Transient LXT 240402A and the Einstein Probe EP 250207b, whose precise positions lie close to nearby (z ≲ 0.1) quiescent galaxies with a negligible probability of chance coincidence, identifying them as particularly promising cases of merger-driven explosions in the local Universe. Methods. We used Chandra to derive accurate localisations for both events and secure otherwise ambiguous associations with their optical counterparts. Deep optical and near-infrared observations with VLT, GTC, and LBT were performed to characterise the surrounding environment and search for kilonova emission, the hallmark of neutron star mergers. Complementary early-time X-ray monitoring with Swift and Einstein Probe was used to constrain the non-thermal afterglow. Results. We find that both FXRTs remain compatible with a compact binary merger progenitor, which produced low-mass ejecta and kilonova emission subdominant to the afterglow. However, alternative explanations such as a distant (z ≳ 1) core-collapse supernova cannot be conclusively ruled out.

79 ASTRONOMY AND ASTROPHYSICS↗

Active Cancellation of Servo-Induced Noise on Stabilized Lasers via Feedforward

Many precision laser applications require active frequency stabilization. However, such stabilization loops operate by pushing noise to frequencies outside their bandwidth, leading to large “servo bumps” that can have deleterious effects for certain applications. The prevailing approach to filtering this noise is to pass the laser through a high-finesse optical cavity, which places constraints on the system design. Here, we propose and demonstrate a different approach where a frequency error signal is derived from a beat note between the laser and the light that passes through the reference cavity. The phase noise derived from this beat note is fed forward to an electro-optic modulator after the laser, carefully accounting for relative delay, for real-time frequency correction. With a hertz-line-width laser, we show ≳20 dB noise suppression at the peak of the servo bump (approximately 250 kHz) and a noise-suppression bandwidth of approximately 5 MHz—well beyond the servo bump. By simulating the Rabi dynamics of a two-level atom with our measured data, we demonstrate substantial improvements to the pulse fidelity over a wide range of Rabi frequencies. Here, our approach offers a simple and versatile method for obtaining a clean spectrum of a narrow-line-width laser, as required in many emerging applications of cold atoms, and is readily compatible with commercial systems that may even include wavelength conversion.

47 OTHER INSTRUMENTATION↗

Micromachined Silicon Platform for Precise Assembly of 2D Multilayer Laue Lenses for High-Resolution X-ray Microscopy

We report on a developed micromachined silicon platform for the precise assembly of 2D multilayer Laue lenses (MLLs) for high-resolution X-ray microscopy. The platform is 10 × 10 mm2 and is fabricated on ~500 µm thick silicon wafers through multiple steps of photolithography and deep reactive-ion etching. The platform accommodates two linear MLLs in a pre-defined configuration with precise angular and lateral position control. In this work, we discuss the design and microfabrication of the platform, and characterization regarding MLLs assembly, position control, repeatability, and stability. The results demonstrate that a micromachined platform can be used for the assembly of a variety of MLLs with different dimensions and optical parameters. The angular misalignment of 2D MLLs is well controlled in the range of the designed accuracy, down to a few millidegrees. The separation distance between MLLs is adjustable from hundreds to more than one thousand micrometers. The use of the developed platform greatly simplifies the alignment procedure of the MLL optics and reduces the complexity of the X-ray microscope. It is a significant step forward for the development of monolithic 2D MLL nanofocusing optics for high-resolution X-ray microscopy.

36 MATERIALS SCIENCE↗

Into the UV: A Precise Transmission Spectrum of HAT-P-41b Using Hubble’s WFC3/UVIS G280 Grism

The ultraviolet–visible wavelength range holds critical spectral diagnostics for the chemistry and physics at work in planetary atmospheres. To date, time-series studies of exoplanets to characterize their atmospheres have relied on several combinations of modes on the Hubble Space Telescope’s STIS/COS instruments to access this wavelength regime. Here for the first time, we apply the Hubble WFC3/UVIS G280 grism mode to obtain exoplanet spectroscopy from 200 to 800 nm in a single observation. We test the G280 grism mode on the hot Jupiter HAT-P-41b over two consecutive transits to determine its viability for the characterization of exoplanet atmospheres. We obtain a broadband transit depth precision of 29–33 ppm and a precision of on average 200 ppm in 10 nm spectroscopic bins. Spectral information from the G280 grism can be extracted from both the positive and negative first-order spectra, resulting in a 60% increase in the measurable flux. Additionally, the first Hubble Space Telescope orbit can be fully utilized in the time-series analysis. We present detailed extraction and reduction methods for use by future investigations with this mode, testing multiple techniques. We find the results to be fully consistent with STIS measurements of HAT-P-41b from 310 to 800 nm, with the G280 results representing a more observationally efficient and precise spectrum. HAT-P-41b’s transmission spectrum is best fit with a model with T {sub eq} = 2091 K, high metallicity, and significant scattering and cloud opacity. With these first-of-their-kind observations, we demonstrate that WFC3/UVIS G280 is a powerful new tool to obtain UV–optical spectra of exoplanet atmospheres, adding to the UV legacy of Hubble and complementing future observations with the James Webb Space Telescope.

79 ASTRONOMY AND ASTROPHYSICS↗

Hydrophilic, light active coating for membranes

A porous membrane provides enhanced filtration of pollutants and particles by coating the membrane with conformal thin films of doped titanium dioxide via atomic layer deposition or, alternatively, sequential infiltration synthesis. The membrane can either be organic or inorganic, and the doping of the membrane, usually with nitrogen, is an important feature that shifts the optical absorption of the TiO2 from the UV range into the visible-light range. This enables the use of lower energy light, including sunlight, to activate the photocatalytic function of the film. The coating described in the present invention is compatible with virtually any porous membrane and allows for precise tuning of the pore size with molecular precision. The present invention presents a new coating process and chemical structure that provides catalytic activity, strongly enhanced by light, to both mitigate fouling and break down various organic pollutants in the process stream.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ACCESS: An Optical Transmission Spectrum of the High-gravity Hot Jupiter HAT-P-23b

We present a new ground-based visible transmission spectrum of the high-gravity, hot Jupiter HAT-P-23b, obtained as part of the ACCESS project. We derive the spectrum from five transits observed between 2016 and 2018, with combined wavelength coverage between 5200 Å and 9269 Å in 200 Å bins, and with a median precision of 247 ppm per bin. HAT-P-23b’s relatively high surface gravity (g ≈ 30 m s{sup −2}), combined with updated stellar and planetary parameters from Gaia DR2, gives a five-scale-height signal of 384 ppm for a hydrogen-dominated atmosphere. Bayesian models favor a clear atmosphere for the planet with the tentative presence of TiO, after simultaneously modeling stellar contamination, using spots parameter constraints from photometry. If confirmed, HAT-P-23b would be the first example of a high-gravity gas giant with a clear atmosphere observed in transmission at optical/near-IR wavelengths; therefore, we recommend expanding observations to the UV and IR to confirm our results and further characterize this planet. This result demonstrates how combining transmission spectroscopy of exoplanet atmospheres with long-term photometric monitoring of the host stars can help disentangle the exoplanet and stellar activity signals.

47 OTHER INSTRUMENTATION↗

Finding Multiply Lensed and Binary Quasars in the DESI Legacy Imaging Surveys

The time delay between multiple images of strongly lensed quasars is a powerful tool for measuring the Hubble constant ( H 0 ). To achieve H 0 measurements with higher precision and accuracy using the time delay, it is crucial to expand the sample of lensed quasars. We conduct a search for strongly lensed quasars in the Dark Energy Spectroscopic Instrument (DESI) Legacy Imaging Surveys. The DESI Legacy Surveys comprise 19,000 deg 2 of the extragalactic sky observed in three optical bands ( g , r , and z ), making it well suited for the discovery of new strongly lensed quasars. We apply an autocorrelation algorithm to ~5 million objects classified as quasars in the DESI Quasar Sample. These systems are visually inspected and ranked. Here, we present 436 new multiply lensed and binary quasar candidates, 65 of which have redshifts from Sloan Digital Sky Survey Data Release 16. We provide redshifts for an additional 18 candidates from the SuperNova Integral Field Spectrograph.

79 ASTRONOMY AND ASTROPHYSICS↗

Decoding ultrafast polarization responses in lead halide perovskites by the two-dimensional optical Kerr effect

Significance Optoelectronic devices, such as photovoltaics or light-emitting diodes, are based on the interaction of light with charges in the active material. Lead halide perovskites (LHPs) have emerged as excellent materials for optoelectronics, but mysteries remain as to how these materials interact with light. Here, we develop a spectroscopic method to observe the nearly instantaneous responses of LHPs to propagating light fields. This method has allowed us to precisely trace a nonlinear material response resulting from the mixing of different light components overtaking each other during propagation. The resulting oscillatory signals could be easily confused with collective motions of ions or molecules, but are quantitatively accounted by strong nonlinear mixing and polarization-dressed light propagation in single-crystal LHPs.

14 SOLAR ENERGY↗

Ultracool Dwarfs Observed with the Spitzer Infrared Spectrograph. I. An Accurate Look at the L-to-T Transition at ~300 Myr from Optical Through Mid-infrared Spectrophotometry

Here we present Spitzer IRS 5–14 μm spectra and 16 μm and 22 μm photometry of the T2.5 companion to the ~300 Myr old G0V star HN Peg. We incorporate previous 0.8–5 μm observations to obtain the most comprehensive spectral energy distribution (SED) of an intermediate-gravity L/T-transition dwarf that, together with an accurate Gaia EDR3 parallax of the primary, enables us to derive precise fundamental parameters. We find that young (≈0.1–0.3 Gyr) early-T dwarfs on average have ≈140 K lower effective temperatures, ≈20% larger radii, and similar bolometric luminosities compared to ≳1 Gyr old field dwarfs with similar spectral types. Our accurate infrared spectrophotometry offers new detail at wavelengths where the dominant carbon-bearing molecules have their strongest transitions: at 3.4 μm for methane and at 4.6 μm for carbon monoxide. We assess the performance of various widely available photospheric models and find that models with condensates and/or clouds better reproduce the full SED of this moderately young early-T dwarf. However, cloud-free models incorporating a more general convective instability treatment reproduce at least the low-resolution near-infrared spectrum similarly well. Our analysis of R ≈ 2300 J-band spectra shows that the near-infrared potassium absorption lines in HN Peg B have similar strengths to those seen in both younger and older T2–T3 dwarfs. We conclude that while alkali lines are well established as surface gravity indicators for L-type or warmer stars, they are insensitive to surface gravity in early-T dwarfs.

79 ASTRONOMY AND ASTROPHYSICS↗

Surface oxygen exchange kinetics of mixed conducting oxides: Dilatometric vs electrical conductivity relaxation study

The surface oxygen exchange kinetics of mixed ionic-electronic conducting (MIEC) oxides play a crucial role in a variety of applications, including solid oxide fuel/electrolysis cells (SOFCs/SOECs), permeation membranes and sensors. To date, a variety of methods, including isotope exchange, electrical conductivity, optical absorptivity and thermogravimetry relaxation, and impedance spectroscopy have been used to measure the oxygen exchange coefficient of MIEC oxides. Each of these methods have their advantages and limitations, depending on the physical and chemical properties of the investigated materials and their sample dimensions and densities. Here, we demonstrate the ability to precisely measure the surface oxygen exchange coefficient (k chem ) of MIEC model material Pr 0.1 Ce 0.9 O 2-δ (PCO) by use of dilatometric relaxation measurements, particularly of interest for materials that exhibit larger chemical expansion coefficients. This is achieved by use of porous bulk specimens to ensure that the contribution of oxygen exchange to the overall kinetics is dominant. We demonstrate that k chem values extracted from chemical expansion relaxation measurements on PCO are nearly identical to those derived from electrical conductivity relaxation measurements. As a result, this provides the opportunity to precisely investigate the oxygen exchange and chemical expansion kinetics of a wide range of materials used in high-temperature applications, particularly where more conventional methods are difficult or inappropriate to apply.

(Pr,Ce)O2-x↗

Control of quantum electrodynamical processes by shaping electron wavepackets

Fundamental quantum electrodynamical (QED) processes, such as spontaneous emission and electron-photon scattering, encompass phenomena that underlie much of modern science and technology. Conventionally, calculations in QED and other field theories treat incoming particles as single-momentum states, omitting the possibility that coherent superposition states, i.e., shaped wavepackets, can alter fundamental scattering processes. Here, we show that free electron waveshaping can be used to design interferences between two or more pathways in a QED process, enabling precise control over the rate of that process. As an example, we show that free electron waveshaping modifies both spatial and spectral characteristics of bremsstrahlung emission, leading for instance to enhancements in directionality and monochromaticity. The ability to tailor general QED processes opens up additional avenues of control in phenomena ranging from optical excitation (e.g., plasmon and phonon emission) in electron microscopy to free electron lasing in the quantum regime.

42 ENGINEERING↗

Detector architecture and data flow of the CMS HGCAL Phase-2 Endcap Calorimeter Upgrade

The CMS High Granularity Calorimeter (HGCAL) is the Phase-2 endcap calorimeter upgrade for the High-Luminosity Large Hadron Collider, designed to provide precise spatial, energy, and timing measurements in a high-radiation, high-pileup environment. This work presents an overview of the HGCAL assembly process, detector architecture, and end-to-end data flow. The data flow goes from signal generation in silicon sensors and scintillator tiles through front-end electronics, optical transmission, and back-end data acquisition. The study highlights how the integrated detector, electronics, and readout systems enable efficient event reconstruction and support the physics objectives of the HL-LHC.

Osei Boakye, Prince [Grambling State U.]↗

Direct Write of 3D Nanoscale Mesh Objects with Platinum Precursor via Focused Helium Ion Beam Induced Deposition

The next generation optical, electronic, biological, and sensing devices as well as platforms will inevitably extend their architecture into the 3rd dimension to enhance functionality. In focused ion beam induced deposition (FIBID), a helium gas field ion source can be used with an organometallic precursor gas to fabricate nanoscale structures in 3D with high-precision and smaller critical dimensions than focused electron beam induced deposition (FEBID), traditional liquid metal source FIBID, or other additive manufacturing technology. In this work, we report the effect of beam current, dwell time, and pixel pitch on the resultant segment and angle growth for nanoscale 3D mesh objects. We note subtle beam heating effects, which impact the segment angle and the feature size. Additionally, we investigate the competition of material deposition and sputtering during the 3D FIBID process, with helium ion microscopy experiments and Monte Carlo simulations. Our results show complex 3D mesh structures measuring ~300 nm in the largest dimension, with individual features as small as 16 nm at full width half maximum (FWHM). These assemblies can be completed in minutes, with the underlying fabrication technology compatible with existing lithographic techniques, suggesting a higher-throughput pathway to integrating FIBID with established nanofabrication techniques.

36 MATERIALS SCIENCE↗

Measuring Nd(III) Solution Concentration in the Presence of Interfering Er(III) and Cu(II) Ions: A Partial Least Squares Analysis of Ultraviolet–Visible Spectra

Optical spectroscopy is a powerful characterization tool with applications ranging from fundamental studies to real-time process monitoring. However, it can be difficult to apply to complex samples that contain interfering analytes which are common in processing streams. Multivariate (chemometric) analysis has been examined for providing selectivity and accuracy to the analysis of optical spectra and expanding its potential applications. Here we will discuss chemometric modeling with an in-depth comparison to more simplistic analysis approaches and outline how chemometric modeling works while exploring the limits on modeling accuracy. Understanding the limitations of the chemometric model can provide better analytical assessment regarding the accuracy and precision of the analytical result. This will be explored in the context of UV–Vis absorbance of neodymium (Nd 3+ ) in the presence of interferents, erbium (Er 3+ ) and copper (Cu 2+ ) under conditions simulating the liquid–liquid extraction approach used to recycle plutonium (Pu) and uranium (U) in used nuclear fuel worldwide. Finally, the selected chemometric model, partial least squares regression, accurately quantifies Nd 3+ with a low percentage error in the presence of interfering analytes and even under conditions that the training set does not describe.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Unusual Transmission Spectrum for the Sub-Saturn KELT-11b Suggestive of a Subsolar Water Abundance

We present an optical-to-infrared transmission spectrum of the inflated sub-Saturn KELT-11b measured with the Transiting Exoplanet Survey Satellite (TESS), the Hubble Space Telescope (HST) Wide Field Camera 3 G141 spectroscopic grism, and the Spitzer Space Telescope (Spitzer) at 3.6 μm, in addition to a Spitzer 4.5 μm secondary eclipse. The precise HST transmission spectrum notably reveals a low-amplitude water feature with an unusual shape. Based on free-retrieval analyses with varying molecular abundances, we find strong evidence for water absorption. Depending on model assumptions, we also find tentative evidence for other absorbers (HCN, TiO, and AlO). The retrieved water abundance is generally ≲0.1× solar (0.001–0.7× solar over a range of model assumptions), several orders of magnitude lower than expected from planet formation models based on the solar system metallicity trend. We also consider chemical-equilibrium and self-consistent 1D radiative-convective equilibrium model fits and find that they, too, prefer low metallicities ([M/H] ≲ -2, consistent with the free-retrieval results). However, all of the retrievals should be interpreted with some caution because they either require additional absorbers that are far out of chemical equilibrium to explain the shape of the spectrum or are simply poor fits to the data. Finally, we find that the Spitzer secondary eclipse is indicative of full heat redistribution from KELT-11b’s dayside to nightside, assuming a clear dayside. These potentially unusual results for KELT-11b’s composition are suggestive of new challenges on the horizon for atmosphere and formation models in the face of increasingly precise measurements of exoplanet spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Method to derive the infrared complex refractive indices n(λ) and k(λ) for organic solids from KBr pellet absorption measurements

Obtaining the complex refractive index vectors $n($$\tilde{v})$ and $k($$\tilde{v})$ allows calculation of the (infrared) reflectance spectrum that is obtained from a solid in any of its many morphological forms. Here, we report an adaptation to the KBr pellet technique using two gravimetric dilutions to derive quantitative $n($$\tilde{v})$/$k($$\tilde{v})$ for dozens of powders with greater repeatability. The optical constants of bisphenol A and sucrose are compared to those derived by other methods, particularly for powdered materials. The variability of the $k$ values for bisphenol A was examined by 10 individual measurements, showing an average coefficient of variation for $k$ peak heights of 5.6%. Though no established standards exist, the pellet-derived $k$ peak values of bisphenol A differ by 11% and 31% from their single-angle- and ellipsometry-derived values, respectively. These values provide an initial estimate of the precision and accuracy of complex refractive indices that can be derived using this method. Limitations and advantages of the method are discussed, the salient advantage being a more rapid method to derive $n$/$k$ for those species that do not readily form crystals or specular pellets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New insights into the mechanism of ultrasonic atomization for the production of metal powders in additive manufacturing

Ultrasonic atomization is one of the promising technologies for producing metal powders for additive manufacturing, where precise control of particle size and morphology is essential. In this study, we coupled an ultrasonic transducer with a carbon fiber plate and atomized liquid droplets and films under different vibration amplitudes. Water, glycerol, and pure aluminum melt were used to study the atomization mechanism and the resulting droplet/powder characteristics, respectively. High-speed optical and ultrafast synchrotron X-ray imaging were used to study in situ the ultrasonic atomization dynamics, including pulsation and clustering of cavities inside the liquid layer/films, development of capillary waves, and formation of liquid droplets. For the first time, we observed and captured the occurrence of cavitation during the atomization of resting drops, films and impact droplets. The inertial cavitation events interfered with the capillary waves across the interphase boundary, puncturing and breaking the boundary to produce atomized mist. The in situ observation revealed the intricate dynamics of ultrasonic atomization and underscored the pivotal role of cavitation events throughout the entire atomization process. We also conducted experiments on ultrasonic atomization of liquid aluminum, producing particles of perfectly spherical shape. The particle size tended to decrease with reduced vibration amplitude Our work has demonstrated the important processing strategies on how to tailor the particle size while ensuring consistent particle shape and morphology, which is the key processing capability for producing high quality powders for additive manufacturing applications.

36 MATERIALS SCIENCE↗

Quantum Plasmonic Sensors

The extraordinary sensitivity of plasmonic sensors is well-known in the optics and photonics community. These sensors exploit simultaneously the enhancement and the localization of electromagnetic fields close to the interface between a metal and a dielectric. This enables, for example, the design of integrated biochemical sensors at scales far below the diffraction limit. Despite their practical realization and successful commercialization, the sensitivity and associated precision of plasmonic sensors are starting to reach their fundamental classical limit given by quantum fluctuations of light—known as the shot-noise limit. To improve the sensing performance of these sensors beyond the classical limit, quantum resources are increasingly being employed. This area of research has become known as “quantum plasmonic sensing”, and it has experienced substantial activity in recent years for applications in chemical and biological sensing. This review aims to cover both plasmonic and quantum techniques for sensing, and it shows how they have been merged to enhance the performance of plasmonic sensors beyond traditional methods. We discuss the general framework developed for quantum plasmonic sensing in recent years, covering the basic theory behind the advancements made, and describe the important works that made these advancements. We also describe several key works in detail, highlighting their motivation, the working principles behind them, and their future impact. The intention of the review is to set a foundation for a burgeoning field of research that is currently being explored out of intellectual curiosity and for a wide range of practical applications in biochemistry, medicine, and pharmaceutical research.

47 OTHER INSTRUMENTATION↗