Search NASA⌕ Search

SEARCH · Search NASA

Results for “QUALITY FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

High Power Co-Axial SRF Coupler

There are over 35 coupler designs for SRF cavities ranging in frequency from 325 to 1500 MHz. Two-thirds of these designs are coaxial couplers using disk or cylindrical ceramics in various combinations and configurations. While it is well known that dielectric losses go down by several orders of magnitude at cryogenic temperatures, it not well known that the thermal conductivity also goes down, and it is the ratio of thermal conductivity to loss tangent (SRF ceramic Quality Factor) and ceramic volume which will determine the heat load of any given design. We describe a novel robust co-axial SRF coupler design which uses compressed window technology. This technology will allow the use of highly thermally conductive materials for cryogenic windows. The mechanical designs will fit into standard-sized ConFlat® flanges for ease of assembly. Two windows will be used in a coaxial line. The distance between the windows is adjusted to cancel their reflections so that the same window can be used in many different applications at various frequencies.

36 MATERIALS SCIENCE↗

High-Q microsphere integrated with a tapered fiber suitable for biosensing applications

We propose a novel whispering gallery mode (WGM) microsphere resonator integrated with a tapered optical fiber. In the proposed structure, the surface of the silica microsphere is coated with a thin layer of Hafnia (Hafnium dioxide). The results from analytical and numerical simulations indicated that the WGMs can be efficiently excited with quality factors, Q, up to 1.9 × 10{sup 5} in a silica-coated microsphere with a diameter of 24.08 μm, coupled to a tapered silica fiber with 1 μm core radius. The sensitivity, S, and figure of merit, FOM, of the proposed structure were 69 nm/R.I.U (nanometers per refractive index unit) and 1.3 × 10{sup 7}, respectively. Integration of microspheres and coupling system with High-Q and Ultra-High-S can be used for various applications such as detection and biosensing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extremely high transmission of light through a nanohole inside a photonic crystal

The transmission of light through single nanoholes with diameters considerably smaller than the wavelength of light (smaller than {lambda}/10) is experimentally studied. The nanoholes were made in a gold film, which is a part of a photonic crystal forming a microcavity with the quality factor Q Almost-Equal-To 100. A 28-fold increase in the transmission of light through a nanohole inside the microcavity compared to transmission through a nanohole in a gold film is demonstrated. The high spectral selectivity of light transmission through a nanohole is discovered, which is characterized by two features: (i) the transmission maximum is located at the resonance wavelength of the microcavity and (ii) the peak full width at half-maximum is about {lambda}/90.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Characterizing the Distribution of Microwave Surface Resistance of HTS Film Based on Metal Ring

This paper presents a novel method for measuring the microwave surface resistance distribution of high-temperature superconducting thin films by a dielectric resonator with a metal ring. After calibration, the effect of metal ring loss on measurement accuracy is negligible. The measurement resolution is determined by the internal diameter of the metal ring, which makes the design of the device more flexible. Therefore, measurement with high resolution and convenience can be achieved simultaneously by using a metal ring with proper size and operating at a relatively low frequency. A test device working at 32 GHz with TE{sub 01(1 + δ)} mode was developed. Its resolution is a circular area with a diameter of 5 mm and an area of 19.6 mm{sup 2}. The unloaded quality factor of the test device is more than 140,000, when it is loaded by the calibration cavity. The test device has a relative uncertainty of less than 6%, which complies with the uncertainty (20%) specified by the international standard for the microwave surface resistance measurement of high-temperature superconducting (HTS) thin film. The surface resistance distribution of a 2-in. YBCO/LAO/YBCO superconducting film sample was measured by this test device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Introduction of DC line structures into a superconducting microwave 3D cavity

We report a technique that can noninvasively add multiple DC wires into a 3D superconducting microwave cavity for electronic devices that require DC electrical terminals. We studied the influence of our DC lines on the cavity performance systematically. We found that the quality factor of the cavity is reduced if any of the components of the electrical wires cross the cavity equipotential planes. Using this technique, we were able to incorporate a quantum dot (QD) device into a 3D cavity. We then controlled and measured the QD transport signal using the DC lines. We have also studied the heating effects of the QD by the microwave photons in the cavity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Narrowband thermal radiation from closed-end microcavities

High spectral selectivity of thermal radiation is important for achieving high-efficiency energy systems. In this study, intense, narrowband, and low directional absorption/radiation were observed in closed-end microcavity which is a conventional open-end microcavity covered by a semi-transparent thin metal film. The quality factor (Q factor) of optical absorption band strongly depended on the film electrical conductivity. Asymmetric and narrow absorption band with a Q factor of 25 at 1.28 μm was obtained for a 6-nm-thick Au film. Numerical simulations suggest that the formation of a fixed-end mode at the cavity aperture contributes to the narrowband optical absorption. The closed-end microcavity filled with SiO{sub 2} exhibits intense and isotropic thermal radiation over a wide solid angle according to numerical simulation. The narrow and asymmetric absorption spectrum was experimentally confirmed in a model of closed-end microcavity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Epitaxial NbN/AlN/NbN tunnel junctions on Si substrates with TiN buffer layers

We have developed epitaxial NbN/AlN/NbN tunnel junctions on Si (100) substrates with a TiN buffer layer. A 50-nm-thick (200)-oriented TiN thin film was introduced as the buffer layer for epitaxial growth of NbN/AlN/NbN trilayers on Si substrates. The fabricated NbN/AlN/NbN junctions demonstrated excellent tunneling properties with a high gap voltage of 5.5 mV, a large I{sub c}R{sub N} product of 3.8 mV, a sharp quasiparticle current rise with a ΔV{sub g} of 0.4 mV, and a small subgap leakage current. The junction quality factor R{sub sg}/R{sub N} was about 23 for the junction with a J{sub c} of 47 A/cm{sup 2} and was about 6 for the junction with a J{sub c} of 3.0 kA/cm{sup 2}. X-ray diffraction and transmission electron microscopy observations showed that the NbN/AlN/NbN trilayers were grown epitaxially on the (200)-orientated TiN buffer layer and had a highly crystalline structure with the (200) orientation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of the neutron leakage from a dedicated intraoperative radiation therapy electron linear accelerator and a conventional linear accelerator for 9, 12, 15(16), and 18(20) MeV electron energies

The issue of neutron leakage has recently been raised in connection with dedicated electron-only linear accelerators used for intraoperative radiation therapy (IORT). In particular, concern has been expressed about the degree of neutron production at energies of 10 MeV and higher due to the need for additional, perhaps permanent, shielding in the room in which the device is operated. In particular, three mobile linear accelerators available commercially offer electron energies at or above the neutron threshold, one at 9 MeV, one at 10 MeV, and the third at 12 MeV. To investigate this problem, neutron leakage has been measured around the head of two types of electron accelerators at a distance of 1 m from the target at azimuthal angles of 0 deg., 45 deg., 90 deg., 135 deg., and 180 deg. The first is a dedicated electron-only (nonmobile) machine with electron energies of 6 (not used here), 9, 12, 15, and 18 MeV and the second a conventional machine with electron energies of 6 (also not used here), 9, 12, 16, and 20 MeV. Measurements were made using neutron bubble detectors and track-etch detectors. For electron beams from a conventional accelerator, the neutron leakage in the forward direction in Sv/Gy is 2.1x10{sup -5} at 12 MeV, 1.3x10{sup -4} at 16 MeV, and 4.2x10{sup -4} at 20 MeV, assuming a quality factor (RBE) of 10. For azimuthal angles >0 deg., the leakage is almost angle independent [2x10{sup -6} at 12 MeV; (0.7-1.6)x10{sup -5} at 16 MeV, and (1.6-2.9)x10{sup -5} at 20 MeV]. For the electron-only machine, the neutron leakage was lower than for the conventional linac, but also independent of azimuthal angle for angles >0 deg. : ([0 deg. : 7.7x10{sup -6} at 12 MeV; 3.0x10{sup -5} at 15 MeV; 1.0x10{sup -4} at 18 MeV]; [other angles: (2.6-5.9)x10{sup -7} at 12 MeV; (1.4-2.2)x10{sup -6} at 15 MeV; (2.7-4.7)x10{sup -6} at 18 MeV]). Using the upper limit of 6x10{sup -7} Sv/Gy at 12 MeV for the IORT machine for azimuthal angles >0 deg. and assuming a workload of 200 Gy/wk and an inverse square factor of 10, the neutron dose equivalent is calculated to be 0.012 mSv/wk. For the primary beam at 12 MeV (0 deg. ), the 10x higher dose would be compensated by the attenuation of a primary beam stopper in a mobile linear accelerator. These neutron radiation levels are below regulatory values (National Council on Radiation Protection and Measurements, 'Limitation of exposure to ionizing radiation', NCRP Report No. 116, NCRP Bethesda, MD, 1993)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characteristics of a Laser Resonant Ultrasonic Spectroscopy System for Measuring the Elastic Constants of Materials

Resonant ultrasound spectroscopy (RUS) is a useful technique for measuring the elastic properties of materials. In this study, two experimental approaches for performing RUS are experimentally analyzed and compared: 1) contact transduction using piezoelectric transducers (PZT) and 2) laser transduction using pulse laser excitation and laser interferometric detection. A single Zircaloy sample cut from a nuclear pressure tube was used for this study. By virtue of the non-contact nature, the quality factor, Q, for laser RUS is shown to be higher than the contact RUS. In addition, the probe beam for laser-RUS can be scanned to form a 2D image of each vibrational mode, which in turn enables unique mode identification. These defining characteristics of laser-RUS enable straightforward discrimination of closely spaced resonant modes and provide key advantages for improving the resolution of resonant ultrasound spectroscopy.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of feature-size dependent etching on the optical properties of photonic crystal devices

Feature size dependence in Ar/Cl{sub 2} chemically assisted ion beam etching of InP-based photonic crystals (PhCs) and its influence on the optical properties of PhC devices operating in the band gap are investigated. The analysis of the measured quality factors, the determined mirror reflectivities, and losses of one-dimensional Fabry-Perot cavities clearly demonstrates the importance of feature-size dependent etching. The optical properties show a dramatic improvement up to a hole depth of about 3.5 {mu}m that is primarily due to a significant reduction in extrinsic losses. However, beyond this hole depth, the improvement is at a lower rate, which suggests that extrinsic losses, although present, are not dominant.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determining the microwave coupling and operational efficiencies of a microwave plasma assisted chemical vapor deposition reactor under high pressure diamond synthesis operating conditions

The microwave coupling efficiency of the 2.45 GHz, microwave plasma assisted diamond synthesis process is investigated by experimentally measuring the performance of a specific single mode excited, internally tuned microwave plasma reactor. Plasma reactor coupling efficiencies (η) > 90% are achieved over the entire 100–260 Torr pressure range and 1.5–2.4 kW input power diamond synthesis regime. When operating at a specific experimental operating condition, small additional internal tuning adjustments can be made to achieve η > 98%. When the plasma reactor has low empty cavity losses, i.e., the empty cavity quality factor is >1500, then overall microwave discharge coupling efficiencies (η{sub coup}) of >94% can be achieved. A large, safe, and efficient experimental operating regime is identified. Both substrate hot spots and the formation of microwave plasmoids are eliminated when operating within this regime. This investigation suggests that both the reactor design and the reactor process operation must be considered when attempting to lower diamond synthesis electrical energy costs while still enabling a very versatile and flexible operation performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic shielding for the Fermilab Vertical Cavity Test Facility

A superconducting RF cavity has to be shielded from magnetic fields present during cool down below the critical temperature to avoid freezing in the magnetic flux at localized impurities, thereby degrading the cavity intrinsic quality factor Q{sub 0}. The magnetic shielding designed for the Fermilab vertical cavity test facility (VCTF), a facility for CW RF vertical testing of bare ILC 1.3 GHz 9-cell SRF cavities, was recently completed. For the magnetic shielding design, we used two cylindrical layers: a room temperature 'outer' shield of Amumetal (80% Ni alloy), and a 2K 'inner' shield of Cryoperm 10. The magnetic and mechanical design of the magnetic shielding and measurement of the remanent magnetic field inside the shielding are described.

43 PARTICLE ACCELERATORS↗

Resonant cavity mode dependence of anomalous and inverse spin Hall effect

The direct current electric voltage induced by the Inverse Spin Hall Effect (ISHE) and Anomalous Hall Effect (AHE) was investigated in the TE{sub 011} and TE{sub 102} cavities. The ISHE and AHE components were distinguishable through the fitting of the voltage spectrum. The unwanted AHE was minimized by placing the DUT (Device Under Test) at the center of both the TE{sub 011} and TE{sub 102} cavities. The voltage of ISHE in the TE{sub 011} cavity was larger than that in the TE{sub 102} cavity due to the higher quality factor of the former. Despite optimized centering, AHE voltage from TE{sub 011} cavity was also higher. The reason was attributed to the E-field distribution inside the cavity. In the case of the TE{sub 011} cavity, the DUT was easily exposed to the E-field in all directions. Therefore, the parasitic AHE voltage in the TE{sub 102} cavity was less sensitive than that in the TE{sub 011} cavity to decentering problem.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Frequency-tunable superconducting resonators via nonlinear kinetic inductance

We have designed, fabricated, and tested a frequency-tunable high-Q superconducting resonator made from a niobium titanium nitride film. The frequency tunability is achieved by injecting a DC through a current-directing circuit into the nonlinear inductor whose kinetic inductance is current-dependent. We have demonstrated continuous tuning of the resonance frequency in a 180 MHz frequency range around 4.5 GHz while maintaining the high internal quality factor Q{sub i} > 180 000. This device may serve as a tunable filter and find applications in superconducting quantum computing and measurement. It also provides a useful tool to study the nonlinear response of a superconductor. In addition, it may be developed into techniques for measurement of the complex impedance of a superconductor at its transition temperature and for readout of transition-edge sensors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficient and robust analysis of complex scattering data under noise in microwave resonators

Superconducting microwave resonators are reliable circuits widely used for detection and as test devices for material research. A reliable determination of their external and internal quality factors is crucial for many modern applications, which either require fast measurements or operate in the single photon regime with small signal to noise ratios. Here, we use the circle fit technique with diameter correction and provide a step by step guide for implementing an algorithm for robust fitting and calibration of complex resonator scattering data in the presence of noise. The speedup and robustness of the analysis are achieved by employing an algebraic rather than an iterative fit technique for the resonance circle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BPM Button Optimization to Minimize Distortion Due to Trapped Mode Heating

The outer circumference of a BPM button and the inner circumference of the button housing comprise a transmission line. This transmission line typically presents an impedance of a few tens of ohms to the beam, and couples very weakly to the 50 ohm coaxial transmission line that comprises the signal path out of the button. The modes which are consequently excited and trapped often have quality factors of several hundred, permitting resonant excitation by the beam. The thermal distortion resulting from trapped mode heating is potentially problematic for achieving the high precision beam position measurements needed to provide the sub-micron beam position stability required by light source users. We present a button design that has been optimized via material selection and component geometry to minimize both the trapped mode heating and the resulting thermal distortion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of refractive index sensing based on 2D PhC air-slot width-modulated line-defect microcavity

In this paper, we propose an investigated sensor array based on two-dimensional photonic crystal air-slot width-modulated line-defect microcavity. This sensor consists of a waveguide coupled with microcavity. To achieve a high quality factor, we have tuned some parameters of the microcavity. The principle of sensing is based on the resonance wavelength shift when the refractive index is changed. For sensitivity analysis, we proposed various conventional designs (A–D). We demonstrated that the design D has the highest sensitivity. An air-slot is created within the line-defect. The existence of the slots enhances the light-matter interactions. The simulation results are obtained by using finite-deference time-domain method. The sensitivity can achieve 400 nm/RIU, with detection limit of 2.98 × 10{sup −5} RIU.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

KELT-16b: A Highly Irradiated, Ultra-short Period Hot Jupiter Nearing Tidal Disruption

We announce the discovery of KELT-16b, a highly irradiated, ultra-short period hot Jupiter transiting the relatively bright (V = 11.7) star TYC 2688-1839-1/KELT-16. A global analysis of the system shows KELT-16 to be an F7V star with T{sub eff}=6236±54 K, logg{sub ⋆}=4.253{sub −0.036}{sup +0.031}, [Fe/H]=−0.002{sub −0.085}{sup +0.086}, M{sub ⋆}=1.211{sub −0.046}{sup +0.043} M{sub ⊙}, and R{sub ⋆} =1.360{sub −0.053}{sup +0.064}R{sub ⊙}. The planet is a relatively high-mass inflated gas giant with M{sub P}=2.75{sub −0.15}{sup +0.16}M{sub J}, R{sub P}=1.415{sub −0.067}{sup +0.084}R{sub J}, density ρ{sub P}=1.20±0.18 g cm{sup −3}, surface gravity log g{sub P}=3.530{sub −0.049}{sup +0.042}, and T{sub eq}=2453{sub −47}{sup +55} K. The best-fitting linear ephemeris is T{sub C}=2457247.24791±0.00019 BJD{sub TDB} and P=0.9689951±0.0000024 day. KELT-16b joins WASP-18b, −19b, −43b, −103b, and HATS-18b as the only giant transiting planets with P < 1 day. Its ultra-short period and high irradiation make it a benchmark target for atmospheric studies by the Hubble Space Telescope, Spitzer, and eventually the James Webb Space Telescope. For example, as a hotter, higher-mass analog of WASP-43b, KELT-16b may feature an atmospheric temperature–pressure inversion and day-to-night temperature swing extreme enough for TiO to rain out at the terminator. KELT-16b could also join WASP-43b in extending tests of the observed mass–metallicity relation of the solar system gas giants to higher masses. KELT-16b currently orbits at a mere ∼1.7 Roche radii from its host star, and could be tidally disrupted in as little as a few ×10{sup 5} years (for a stellar tidal quality factor of Q{sub ∗}{sup ′}=10{sup 5}). Finally, the likely existence of a widely separated bound stellar companion in the KELT-16 system makes it possible that Kozai–Lidov (KL) oscillations played a role in driving KELT-16b inward to its current precarious orbit.

79 ASTRONOMY AND ASTROPHYSICS↗