Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quality Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Science & Technology Review March/April 2008

This month's issue has the following articles: (1) Science and Security in Sharp Focus--Commentary by William H. Goldstein; (2) Extending the Search for Extrasolar Planets--The Gemini Planet Imager will delve deep into the universe to identify planets that cannot be detected with current instrumentation; (3) Standardizing the Art of Electron-Beam Welding--The Laboratory's EBeam Profiler makes electron-beam welds consistent and improves quality control; (4) Molecular Building Blocks Made of Diamonds--Livermore physicists are exploring the electrical properties of diamondoids, tiny molecules of diamond; and (5) Animation Brings Science to Life--Animation helps scientists and engineers effectively communicate their ideas and research in a visually compelling way.

36 MATERIALS SCIENCE↗

Epithermal Neutron Activation Analysis of the Asian Herbal Plants

Asian medicinal herbs Chrysanthemum (Spiraea aquilegifolia Pall.) and Red Sandalwood (Pterocarpus Santalinus) are widely used in folk and Ayurvedic medicine for healing and preventing some diseases. The modern medical science has proved that the Chrysanthemum (Spiraea aquilegifolia Pall.) possesses the following functions: reducing blood press, dispelling cancer cell, coronary artery's expanding and bacteriostating and Red Sandalwood (Pterocarpus Santalinus) is recommended against headache, toothache, skin diseases, vomiting and sometimes it is taken for treatment of diabetes. Species of Chrysanthemums were collected in the north-eastern and central Mongolia, and the Red Sandalwood powder was imported from India. Samples of Chrysanthemums (branches, flowers and leaves)(0.5 g) and red sandalwood powder (0.5 g) were subjected to the multi-element instrumental neutron activation analysis using epithermal neutrons (ENAA) at the IBR-2 reactor, Frank Laboratory of Neutron Physics (FLNP) JINR, Dubna. A total of 41 elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Cr, Mn, Fe, Co, Ni, Zn, As, Se, Br, Rb, Sr, Zr, Mo, Cd, Cs, Ba, La, Hf, Ta, W, Sb, Au, Hg, Ce, Nd, Sm, Eu, Tb, Dy, Yb, Th, U, Lu) were determined. For the first time such a large group of elements was determined in the herbal plants used in Mongolia. The quality control of the analytical results was provided by using certified reference material Bowen Cabbage. The results obtained are compared to the ''Reference plant? data (B. Markert, 1992) and interpreted in terms of excess of such elements as Se, Cr, Ca, Fe, Ni, Mo, and rare earth elements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dual-headed SPECT for awake animal brain imaging

Abstract- Motion-corrected awake animal imaging is needed for normal-state investigations of models of neurological disease and brain activity. The awake animal brain SPECT/CT system, AwakeSPECT at Johns Hopkins University has in the past used a single gamma camera for imaging. Enhancements have been made by adding a pinhole collimator to the second gamma camera at the opposite side which has been previously equipped parallel hole collimator. Geometry calibration was performed using a custom built quality control phantom containing three Co-57 point sources and applied to the tomographic reconstruction code. Hot-rod phantom scans with Tc-99m were performed to test sensitivity and resolution improvements. The reconstruction results show significant resolution and sensitivity improvements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Defect Detection in Fuel Cell Gas Diffusion Electrodes Using Infrared Thermography

Polymer electrolyte membrane fuel cells are energy conversion devices that offer high power densities and high efficiencies for mobile and other applications. Successful introduction into the marketplace requires addressing cost barriers such as production volumes and platinum loading. For cost reduction, it is vital to minimize waste and maximize quality during the manufacturing of platinum-containing electrodes, including gas diffusion electrodes (GDEs). In this work, we report on developing a quality control diagnostic for GDEs, involving creating an ex situ exothermic reaction on the electrode surface and using infrared thermography to measure the resulting temperature profile. Experiments with a moving GDE containing created defects were conducted to demonstrate the applicability of the diagnostic for real-time web-line inspection.

30 DIRECT ENERGY CONVERSION↗

Analysis of Carbamate Pesticides: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS666

The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method for analysis of aldicarb, bromadiolone, carbofuran, oxamyl, and methomyl in water by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS), titled Method EPA MS666. This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to validate and verify the analytical procedures described in MS666 for analysis of carbamate pesticides in aqueous samples. The gathered data from this validation study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of Method EPA MS666 can be determined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Ethanolamines: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS888

The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method titled 'Analysis of Diethanolamine, Triethanolamine, n-Methyldiethanolamine, and n-Ethyldiethanolamine in Water by Single Reaction Monitoring Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS): EPA Method MS888'. This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to validate and verify the analytical procedures described in 'EPA Method MS888' for analysis of the listed ethanolamines in aqueous samples. The gathered data from this validation study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of 'EPA Method MS888' can be determined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A proteomic analysis of Arabidopsis thaliana seedling responses to 3-oxo-octanoyl-homoserine lactone, a bacterial quorum-sensing signal

Highlights: Black-Right-Pointing-Pointer 3OC8-HSL can change the expression of diverse proteins in Arabidopsis. Black-Right-Pointing-Pointer 3OC8-HSL responsive proteins were identified using MALDI-TOF-MS. Black-Right-Pointing-Pointer Plant could have an extensive range of functional responses to bacterial AHL. -- Abstract: N-acyl-homoserine lactones (AHLs) are a class of bacterial quorum-sensing (QS) signals that are commonly used by Gram-negative bacteria for cell-to-cell communication. Recently, it has become evident that AHLs can regulate plant root growth and trigger plant defense responses; however, little is known about the plant response mechanisms to bacterial QS signals. In this study, we used a proteomic approach to investigate the responses of Arabidopsis thaliana seedlings to N-3-oxo-octanoyl-homoserine lactone (3OC8-HSL), a bacterial QS signal. The results revealed that the abundance of 53 protein spots was significantly altered; two thirds of these proteins were found to be up-regulated after 3OC8-HSL treatment. Thirty-four proteins were identified using MALDI-TOF-MS. These 3OC8-HSL-responsive proteins, in addition to one protein of unknown function, are implicated in a variety of physiological processes, including metabolism of carbohydrate and energy, protein biosynthesis and quality control systems, defense response and signal transduction and cytoskeleton remodeling. Our bioinformatic analysis indicated that the chloroplasts are the intracellular organelles most influenced by the exposure to 3OC8-HSL. Our data indicate that plants have an extensive range of functional responses to bacterial AHLs that may play important roles in the interaction between plants and bacteria.

60 APPLIED LIFE SCIENCES↗

TU-A-BRF-01: MR Guided Radiation Therapy

In recent years, there has been an increasing interest in the development of new technologies focused on the deeper integration of MR in radiotherapy. The innovations span from image data acquisition and post-processing to clinical implementation of MR-guided RT systems and workflow development. The session is intended to provide a review of the key and most recent advancements. Targeted discussions will cover topics which currently define the concept of MR-guided radiotherapy including a) system commissioning, quality control and safety, b) MR data manipulation for dose computations and treatment simulation, c) quantification/management of organ motion and treatment delivery guidance. Learning Objectives: Understand the concept and specifics of MR-guided radiotherapy; Understand the requirements for system integration in clinical workflow; Become familiar with the proposed strategies for system commissioning, RT planning and delivery guidance.

60 APPLIED LIFE SCIENCES↗

The Port Hope Area Initiative's Port Granby Project: From Planning to Execution - 17451

The Port Hope Area Initiative's Port Granby Project involves the construction of a new, secure long-term waste management facility (LTWMF) and supporting infrastructure, and the excavation and relocation of some 450,000 m{sup 3} of LLRW and marginally contaminated soil from the former Port Granby Waste Management Facility (PGWMF) to the newly constructed LTWMF. Presented is an overview of the Port Granby Project and a description of the planning needed to execute the project successfully. A comprehensive suite of approximately 40 pre-construction submittals were developed and submitted for review and approval by Canadian Nuclear Laboratories (CNL), the project authority. Importantly, comprehensive training programs were developed and implemented to ensure all project staff fully understood the scope of the planning documents (covering such things as Quality Control, Environmental Monitoring, Radiation Protection, Dust Management, Noise, Radiation Protection etc.) and possess the appropriate competencies for completing the work to which they have been assigned. The effective planning that has been invested in the Port Granby project, from initial design to project planning and implementation, has allowed this complex project to proceed with minimal difficulty. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Phosphonic Acids: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS999

The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method titled Analysis of Diisopropyl Methylphosphonate, Ethyl Hydrogen Dimethylamidophosphate, Isopropyl Methylphosphonic Acid, Methylphosphonic Acid, and Pinacolyl Methylphosphonic Acid in Water by Multiple Reaction Monitoring Liquid Chromatography/Tandem Mass Spectrometry: EPA Version MS999. This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to validate and verify the analytical procedures described in EPA Method MS999 for analysis of the listed phosphonic acids and surrogates in aqueous samples. The gathered data from this validation study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of EPA Method MS999 can be determined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of MLC leaf position, collimator rotation angle, and gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma

The purpose of this study was to investigate the effect of multileaf collimator (MLC) leaf position, collimator rotation angle, and accelerator gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma. To compare dosimetric differences between the simulating plans and the clinical plans with evaluation parameters, 6 patients with nasopharyngeal carcinoma were selected for simulation of systematic and random MLC leaf position errors, collimator rotation angle errors, and accelerator gantry rotation angle errors. There was a high sensitivity to dose distribution for systematic MLC leaf position errors in response to field size. When the systematic MLC position errors were 0.5, 1, and 2 mm, respectively, the maximum values of the mean dose deviation, observed in parotid glands, were 4.63%, 8.69%, and 18.32%, respectively. The dosimetric effect was comparatively small for systematic MLC shift errors. For random MLC errors up to 2 mm and collimator and gantry rotation angle errors up to 0.5°, the dosimetric effect was negligible. We suggest that quality control be regularly conducted for MLC leaves, so as to ensure that systematic MLC leaf position errors are within 0.5 mm. Because the dosimetric effect of 0.5° collimator and gantry rotation angle errors is negligible, it can be concluded that setting a proper threshold for allowed errors of collimator and gantry rotation angle may increase treatment efficacy and reduce treatment time.

61 RADIATION PROTECTION AND DOSIMETRY↗

KNOW THE STAR, KNOW THE PLANET. II. SPECKLE INTERFEROMETRY OF EXOPLANET HOST STARS

A study of the host stars to exoplanets is important for understanding their environment. To that end, we report new speckle observations of a sample of exoplanet host primaries. The bright exoplanet host HD 8673 (= HIP 6702) is revealed to have a companion, although at this time we cannot definitively establish the companion as physical or optical. The observing lists for planet searches and for these observations have for the most part been pre-screened for known duplicity, so the detected binary fraction is lower than what would otherwise be expected. Therefore, a large number of double stars were observed contemporaneously for verification and quality control purposes, to ensure that the lack of detection of companions for exoplanet hosts was valid. In these additional observations, 10 pairs are resolved for the first time and 60 pairs are confirmed. These observations were obtained with the USNO speckle camera on the NOAO 4 m telescopes at both KPNO and CTIO from 2001 to 2010.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of Thiodiglycol: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS777

The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method for the analysis of thiodiglycol, the breakdown product of the sulfur mustard HD, in water by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS), titled Method EPA MS777 (hereafter referred to as EPA CRL SOP MS777). This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to verify the analytical procedures described in MS777 for analysis of thiodiglycol in aqueous samples. The gathered data from this study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of Method EPA MS777 can be determined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of German and American fabrication standards for transportation and storage containments of high level radioactive material type B packages - 15055

As the competent authority for the evaluation of German radioactive material (RAM) transport and storage packages, BAM (the German Federal Institute for Materials Research and Testing) has evaluated various international cask manufacturers regarding compliance with the German Type B(U) licensing requirements. The US NRC has recommended paragraphs in the ASME Boiler and Pressure Vessel (B and PV) Code, Section III, Division 3, as the measure to quantify the safety requirements of the US regulations regarding fabrication of RAM transportation and storage containments. The objective of this study is to compare the fabrication criteria of the German Dangerous Goods Procedural Rules (BAM-GGR) and the German Institute for Standardization (DIN) with the US quantitative measures for fabrication of RAM package containment vessels. This comparison will cover major similarities and differences between the requirements of the German standards and the ASME Code requirements for Type B package containment fabrication QC (quality control). While the material most often used for German RAM containment applications is ductile cast iron (DCI), in the US forged austenitic stainless steel is typically used. This study focuses on fabrication QC measures required to ensure reproducible and acceptable properties for DCI containments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Examination of a Size-Change Test for Photovoltaic Encapsulation Materials: Preprint

We examine a proposed test standard that can be used to evaluate the maximum representative change in linear dimensions of sheet encapsulation products for photovoltaic modules (resulting from their thermal processing). The proposed protocol is part of a series of material-level tests being developed within Working Group 2 of the Technical Committee 82 of the International ElectrotechnicalCommission. The characterization tests are being developed to aid module design (by identifying the essential characteristics that should be communicated on a datasheet), quality control (via internal material acceptance and process control), and failure analysis. Discovery and interlaboratory experiments were used to select particular parameters for the size-change test. The choice of a sandsubstrate and aluminum carrier is explored relative to other options. The temperature uniformity of +/- 5C for the substrate was confirmed using thermography. Considerations related to the heating device (hot-plate or oven) are explored. The time duration of 5 minutes was identified from the time-series photographic characterization of material specimens (EVA, ionomer, PVB, TPO, and TPU). Thetest procedure was revised to account for observed effects of size and edges. The interlaboratory study identified typical size-change characteristics, and also verified the absolute reproducibility of +/- 5% between laboratories.

14 SOLAR ENERGY↗

Prevention of a wrong-location misadministration through the use of an intradepartmental incident learning system

Purpose: A series of examples are presented in which potential errors in the delivery of radiation therapy were prevented through use of incident learning. These examples underscore the value of reporting near miss incidents. Methods: Using a departmental incident learning system, eight incidents were noted over a two-year period in which fields were treated 'out-of-sequence,' that is, fields from a boost phase were treated, while the patient was still in the initial phase of treatment. As a result, an error-prevention policy was instituted in which radiation treatment fields are 'hidden' within the oncology information system (OIS) when they are not in current use. In this way, fields are only available to be treated in the intended sequence and, importantly, old fields cannot be activated at the linear accelerator control console. Results: No out-of-sequence treatments have been reported in more than two years since the policy change. Furthermore, at least three near-miss incidents were detected and corrected as a result of the policy change. In the first two, the policy operated as intended to directly prevent an error in field scheduling. In the third near-miss, the policy operated 'off target' to prevent a type of error scenario that it was not directly intended to prevent. In this incident, an incorrect digitally reconstructed radiograph (DRR) was scheduled in the OIS for a patient receiving lung cancer treatment. The incorrect DRR had an isocenter which was misplaced by approximately two centimeters. The error was a result of a field from an old plan being scheduled instead of the intended new plan. As a result of the policy described above, the DRR field could not be activated for treatment however and the error was discovered and corrected. Other quality control barriers in place would have been unlikely to have detected this error. Conclusions: In these examples, a policy was adopted based on incident learning, which prevented several errors, at least one of which was potentially severe. These examples underscore the need for a rigorous, systematic incident learning process within each clinic. The experiences reported in this technical note demonstrate the value of near-miss incident reporting to improve patient safety.

60 APPLIED LIFE SCIENCES↗

Rhodium self-powered neutron detector as a suitable on-line thermal neutron flux monitor in BNCT treatments

Purpose: A rhodium self-powered neutron detector (Rh SPND) has been specifically developed by the Comision Nacional de Energia Atomica (CNEA) of Argentina to measure locally and in real time thermal neutron fluxes in patients treated with boron neutron capture therapy (BNCT). In this work, the thermal and epithermal neutron response of the Rh SPND was evaluated by studying the detector response to two different reactor spectra. In addition, during clinical trials of the BNCT Project of the CNEA, on-line neutron flux measurements using the specially designed detector were assessed. Methods: The first calibration of the detector was done with the well-thermalized neutron spectrum of the CNEA RA-3 reactor thermal column. For this purpose, the reactor spectrum was approximated by a Maxwell-Boltzmann distribution in the thermal energy range. The second calibration was done at different positions along the central axis of a water-filled cylindrical phantom, placed in the mixed thermal-epithermal neutron beam of CNEA RA-6 reactor. In this latter case, the RA-6 neutron spectrum had been well characterized by both calculation and measurement, and it presented some marked differences with the ideal spectrum considered for SPND calibrations at RA-3. In addition, the RA-6 neutron spectrum varied with depth in the water phantom and thus the percentage of the epithermal contribution to the total neutron flux changed at each measurement location. Local (one point-position) and global (several points-positions) and thermal and mixed-field thermal neutron sensitivities were determined from these measurements. Thermal neutron flux was also measured during BNCT clinical trials within the irradiation fields incident on the patients. In order to achieve this, the detector was placed on patient's skin at dosimetric reference points for each one of the fields. System stability was adequate for this kind of measurement. Results: Local mixed-field thermal neutron sensitivities and global thermal and mixed-field thermal neutron sensitivities derived from measurements performed at the RA-6 were compared and no significant differences were found. Global RA-6-based thermal neutron sensitivity showed agreement with pure thermal neutron sensitivity measurements performed in the RA-3 spectrum. Additionally, the detector response proved nearly unchanged by differences in neutron spectra from real (RA-6 BNCT beam) and ideal (considered for calibration calculations at RA-3) neutron source descriptions. The results confirm that the special design of the Rh SPND can be considered as having a pure thermal response for neutron spectra with epithermal-to-thermal flux ratios up to 12%. In addition, the linear response of the detector to thermal flux allows the use of a mixed-field thermal neutron sensitivity of 1.95 {+-} 0.05 x 10{sup -21} A n{sup -1}{center_dot}cm{sup 2}{center_dot}s. This sensitivity can be used in spectra with up to 21% epithermal-to-thermal flux ratio without significant error due to epithermal neutron and gamma induced effects. The values of the measured fluxes in clinical applications had discrepancies with calculated results that were in the range of -25% to +30%, which shows the importance of a local on-line independent measurement as part of a treatment planning quality control system. Conclusions: The usefulness of the CNEA Rh SPND for the on-line local measurement of thermal neutron flux on BNCT patients has been demonstrated based on an appropriate neutron spectra calibration and clinical applications.

07 ISOTOPE AND RADIATION SOURCES↗

Quality Assurance of Radiation Therapy Planning Systems: Current Status and Remaining Challenges

Computerized radiation therapy planning systems (RTPSs) are pivotal for treatment planning. The acceptance, commissioning, and quality control of RTPSs are uniquely complex and are described in the American Association of Physicists in Medicine Task Group Report 53 (1998) and International Atomic Energy Agency Technical Report Series No. 430 (2004). The International Atomic Energy Agency also developed a document and data package for use by vendors and purchasers to aid with acceptance testing of RTPSs. This document is based on International Electrotechnical Commission standard 62083 (2000) and describes both 'type' tests to be performed in the factory and 'site' tests to be performed in the clinic. The American Association of Physicists Task Group Report 67 described benchmark tests for the validation of dose calculation algorithms. Test data are being produced with the backing of the U.S. National Cancer Institute. However, significant challenges remain. Technology keeps evolving rapidly, thus requiring new quality assurance (QA) procedures. Intensity-modulated radiation therapy with its use of inverse optimization has added a new dimension to QA, because the results are not intuitively obvious. New technologies such as real-time ultrasound guidance for brachytherapy, TomoTherapy, and Cyberknife, require their own specialized RTPSs with unique QA requirements. On-line imaging allows for the generation of dose reconstructions using image warping techniques to determine the daily dose delivered to the patient. With increasing computer speeds, real-time reoptimization of treatment plans will become a reality. Gating technologies will require four-dimensional dose calculations to determine the actual dose delivered to tissue voxels. With these rapidly changing technologies, it is essential that a strong QA culture is invoked in every institution implementing these procedures and that new protocols are developed as a part of the clinical implementation process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗