Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Site Environmental Report for 2016

Lawrence Berkeley National Laboratory (LBNL, Berkeley Lab) is a multi-program scientific facility operated by the University of California (UC) for the U.S. Department of Energy (DOE). Berkeley Lab’s research is focused on the physical, biological, environmental, and computational sciences with the objective of delivering scientific knowledge and discoveries pertinent to DOE’s mission. This annual report describes environmental protection activities and potential impacts resulting from LBNL operations conducted in 2016. The format and content of this report satisfy the requirements of both DOE Order 231.1B Admin Chg 1, Environment, Safety, and Health Reporting, and the operating contract between UC and DOE (DOE Contract No. DE-AC02-05CH11231, also known as Contract 31). Activities are planned and conducted with full regard to protecting employees, the public, and the environment, as well as complying with all applicable environmental, safety, and health laws and regulations. Berkeley Lab implements an Environmental Management System (EMS) to oversee these compliance activities and improve overall environmental performance while maintaining operational capability and sustaining its overall mission. The effectiveness of the EMS and environmental programs is reviewed annually as part of the operating contract’s performance evaluation process. For fiscal year (FY) 2016, which began October 1, 2015, and ended September 30, 2016, the EMS was given a performance rating of A minus for its management of environmental activities (on a scale from A plus as the highest grade to F as the lowest). The measurement and rating system was developed jointly by Berkeley Lab, UC, and DOE. The FY 2016 rating was based on how Berkeley Lab met the objective in DOE’s FY 2017 Performance Evaluation and Measurement Plan (Appendix B in Contract 31, Section J) of providing an efficient and effective EMS. To support this rating, Berkeley Lab prepared a list of projects completed during the performance period that achieved reduced environmental impacts. The EMS was also graded through the federal Office of Management and Budget’s EMS Annual Report Data, in which elements of the International Organization for Standardization (ISO) 14001 standard are rated and the degree of integration between the EMS and Berkeley Lab’s sustainable practices is measured. Overall scores fall into one of three categories: green (highest), yellow (middle), or red (lowest). For FY 2016, Berkeley Lab received a score of green, as described in more detail in Chapter 2. An overview of environmental protection and restoration programs is provided (Chapter 3), including information about compliance activities, operating permits, and regulatory agency inspections that occurred during 2016. Six minor violations issued during these inspections are discussed, one of which was rescinded in 2017. This report also includes information on environmental monitoring performed in 2016 (Chapter 4). The results of these monitoring activities confirmed that groundwater cleanup actions continue to show improving conditions, and all emissions and discharges from LBNL operations were within environmental compliance release limits with the exception of some stormwater discharges. While most stormwater discharges measured throughout the LBNL site fall within acceptable levels established by the state's stormwater permit, iron and aluminum exceeded permitted levels. Berkeley Lab is aggressively implementing controls to reduce iron and aluminum discharge levels. The controls include construction of asphaltic berms to restrain and filter runoff to storm drains, and installation of filtration units in storm drain basins to absorb metal contaminants. The radiological dose assessments (Chapter 5) performed in 2016 concluded that the maximum dose to a hypothetical resident from Berkeley Lab’s airborne radionuclide releases was approximately 0.12% of the DOE and U.S. Environmental Protection Agency annual limit of 10 millirem per year (mrem/year); the dose from all radiation sources at Berkeley Lab was approximately 0.1% of the average natural background radiation dose of 310 mrem/yr in the United States, and about 0.4% of the DOE annual limit of 100 mrem/yr from all sources.

54 ENVIRONMENTAL SCIENCES↗

Site Environmental Report for 2017

Lawrence Berkeley National Laboratory (LBNL, Berkeley Lab) is a multi-program scientific facility operated by the University of California (UC) for the U.S. Department of Energy (DOE). Berkeley Lab’s research is focused on the physical, biological, environmental, and computational sciences with the objective of delivering scientific knowledge and discoveries pertinent to DOE’s mission. This annual report describes environmental protection activities and potential impacts resulting from LBNL operations conducted in 2017. The format and content of this report satisfy the requirements of both DOE Order 231.1B, Administrative Change 1 (Environment, Safety, and Health Reporting) and the operating contract between UC and DOE (DOE Contract No. DE-AC02-05CH11231, also known as Contract 31). Activities are planned and conducted with full regard to protecting employees, the public, and the environment, as well as complying with all applicable environmental, safety, and health laws and regulations. Berkeley Lab implements an Environmental Management System (EMS) to oversee these compliance activities and continually improve overall environmental performance while maintaining operational capability and sustaining its overall mission. The effectiveness of the EMS and environmental programs is reviewed annually as part of the performance evaluation process of Contract 31. For fiscal year (FY) 2017, which began October 1, 2016, and ended September 30, 2017, the EMS was given a performance rating of B plus for its management of environmental activities (on a scale from A plus as the highest grade to F as the lowest). The measurement and rating system was developed jointly by Berkeley Lab, UC, and DOE. The FY 2017 rating was based on how Berkeley Lab met the objective in DOE’s FY 2017 Performance Evaluation and Measurement Plan (Appendix B in Contract 31, Section J) of providing an efficient and effective EMS. Six significant accomplishments, which ranged from effective teaming on projects and with regulatory agencies to improved program assessment approaches, were factors in the rating. The EMS was also graded through the federal Office of Management and Budget’s annual EMS performance metrics, in which a reporting scorecard rates elements of the International Organization for Standardization (ISO) 14001 standard and the degree of integration between the EMS and Berkeley Lab’s sustainable practices. Overall scores fall into one of three categories: green (highest), yellow (middle), or red (lowest). For FY 2017, Berkeley Lab received a score of green, as described in more detail in Chapter 2. An overview of environmental protection and restoration programs is provided, including information about compliance activities, operating permits, and regulatory agency inspections that occurred during 2017. Thirteen minor violations issued during City of Berkeley inspections of above and underground storage tanks, treatment units, and hazardous waste storage areas are discussed in this chapter. This report also includes information on environmental monitoring performed in 2017. The results of these monitoring activities confirmed that groundwater cleanup actions continue to show improving conditions, and all emissions and discharges from LBNL operations were within environmental compliance release limits, with the exception of some stormwater discharges. Most stormwater discharges measured throughout the LBNL site fall within acceptable levels established by the state’s stormwater permit; however, iron and aluminum exceeded Numeric Action Levels. To reduce iron and aluminum discharge levels, Berkeley Lab is aggressively implementing controls such as construction of asphaltic berms and check dams to restrain and filter runoff to storm drains, and installation of filtration units in storm drain basins to collect sediment and absorb metal contaminants. The radiological dose assessments performed in 2017 concluded that the maximum potential dose to a hypothetical resident from Berkeley Lab’s airborne radionuclide releases was approximately 0.1% of the DOE and U.S. Environmental Protection Agency annual limit of 10 millirem per year (mrem/yr); the potential dose from all radiation sources at Berkeley Lab was approximately 0.06% of the average natural background radiation dose of 310 mrem/yr in the United States, and about 0.2% of the DOE annual limit of 100 mrem/yr from all sources.

54 ENVIRONMENTAL SCIENCES↗

Site Environmental Report for 2018

Lawrence Berkeley National Laboratory (LBNL, Berkeley Lab) is a multi-program scientific facility operated by the University of California (UC) for the U.S. Department of Energy (DOE). Berkeley Lab’s research is focused on the physical, biological, environmental, and computational sciences, with the objective of delivering scientific knowledge and discoveries pertinent to DOE’s mission. This annual report describes environmental protection activities and potential impacts resulting from LBNL operations conducted in 2018. The format and content of this report satisfy the requirements of both DOE Order 231.1B, Administrative Change 1 (Environment, Safety, and Health Reporting) and the operating contract between UC and DOE (DOE Contract No. DE-AC02-05CH11231, also known as Contract 31). LBNL activities are planned and conducted with full regard to protecting employees, the public, and the environment, as well as complying with all applicable environmental, safety, and health laws and regulations. As presented in Chapter 2, Berkeley Lab implements an Environmental Management System (EMS) to oversee environmental compliance activities and continually improve overall environmental performance while maintaining operational capability and sustaining its overall mission. The effectiveness of the EMS and environmental programs is reviewed annually as part of the performance evaluation process of Contract 31. For fiscal year (FY) 2018, which began October 1, 2017, and ended September 30, 2018, the EMS was given a performance rating of B plus for its management of environmental activities (on a scale from A plus as the highest grade, to F as the lowest). The measurement and rating system was developed jointly by Berkeley Lab, UC, and DOE. The FY 2018 rating was based on how Berkeley Lab met the objective in DOE’s FY 2018 Performance Evaluation and Measurement Plan (Appendix B in Contract 31, Section J) of providing an efficient and effective EMS. Six significant accomplishments, which ranged from effective teaming on projects and with regulatory agencies to improved program assessment approaches, were factors in the rating. The EMS was also graded through the federal Office of Management and Budget’s annual EMS performance metrics, in which a reporting scorecard rates elements of the International Organization for Standardization (ISO) 14001 standard and the degree of integration between the EMS and Berkeley Lab’s sustainable practices. Overall scores fall into one of three categories: green (highest), yellow (middle), or red (lowest). For FY 2018, Berkeley Lab received a score of green. A week-long formal conformity audit of the EMS was conducted at the end of July by a qualified external party, as is required every three years. The audit team found that Berkeley Lab’s EMS continues to conform to the ISO standard with no major nonconformance. An overview of environmental protection and restoration programs is provided in Chapter 3, including information about compliance activities, operating permits, and regulatory agency inspections and audits that occurred during 2018. Twenty-one minor violations and two Class II violations were issued during agency inspections of programs governing aboveground and underground storage tanks, hazardous waste treatment units, hazardous waste storage areas, hazardous materials management, and wastewater, stormwater, and air emission sources. This report also includes information on environmental monitoring performed in 2018 (Chapter 4). The results of these monitoring activities confirmed that groundwater cleanup actions have been effective in reducing concentrations of volatile organic compounds (VOCs) in the groundwater, although concentrations appear to be reaching asymptotic levels in some areas. Site groundwater plumes are stable or are attenuating, and VOCs are not migrating off site. All emissions and discharges from LBNL operations were within environmental compliance release limits except oxides of nitrogen and carbon monoxide from boilers (under 5 million BTUs) from Buildings 2, 66, and 88. The radiological dose assessments (Chapter 5) performed in 2018 concluded that the maximum potential dose to a hypothetical resident from Berkeley Lab’s airborne radionuclide releases was approximately 0.04% of the DOE and U.S. Environmental Protection Agency annual limit of 10 millirem per year (mrem/yr); the potential dose from all radiation sources at Berkeley Lab was approximately 0.15% of the average natural background radiation dose of 310 mrem/yr in the United States, and about 0.5% of the DOE annual limit of 100 mrem/yr from all sources.

54 ENVIRONMENTAL SCIENCES↗

Fusion of CT Angiography or MR Angiography with Unenhanced CBCT and Fluoroscopy Guidance in Endovascular Treatments of Aorto-Iliac Steno-Occlusion: Technical Note on a Preliminary Experience

AimTo evaluate the feasibility of image fusion (IF) of pre-procedural arterial-phase CT angiography or MR angiography with intra-procedural fluoroscopy for road-mapping in endovascular treatment of aorto-iliac steno-occlusive disease.Materials and MethodsBetween September and November, 2014, we prospectively evaluated 5 patients with chronic aorto-iliac steno-occlusive disease, who underwent endovascular treatment in the angiography suite. Fusion image road-mapping was performed using angiographic phase CT images or MR images acquired before and intra-procedural unenhanced cone-beam CT. Radiation dose of the procedure, volume of intra-procedural iodinated contrast medium, fluoroscopy time, and overall procedural time were recorded. Reasons for potential fusion imaging inaccuracies were also evaluated.ResultsImage co-registration and fusion guidance were feasible in all procedures. Mean radiation dose of the procedure was 60.21 Gycm2 (range 55.02–63.75 Gycm2). The mean total procedure time was 32.2 min (range 27–38 min). The mean fluoroscopy time was 12 min and 3 s. The mean procedural iodinated contrast material dose was 24 mL (range 20–40 mL).ConclusionsIF gives Interventional Radiologists the opportunity to use new technologies in order to improve outcomes with a significant reduction of contrast media administration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-381: Radio-Dynamic Therapy (RDT) for the Treatment of Late-Stage Cancers

Purpose: Photo-dynamic therapy (PDT) is an effective treatment modality because of the preferential absorption of photosensitizing agent in tumor cells than in surrounding normal tissues. A limitation of PDT for cancer therapy is the finite penetration of laser light to activate the targeting agent in deep-seated tumors. Radio-dynamic therapy (RDT) is designed to overcome this problem by the combination of high-energy (up to 45MV) photon beams and photo/radio-sensitizers. This work investigates the feasibility of PDT for late-stage cancer patients who are no longer respond to conventional therapies available. Methods: The high-energy photon beams are generated using a LA45 RaceTrack Microtron (Top Grade Medical, Beijing, China). The targeting agent investigated is 5- aminolevulinic acid (5-ALA). Both in vitro cell lines and in vivo animal models have been used to investigate the mechanisms of RDT and its therapeutic effects and normal tissue toxicities. Oral 5-ALA (30-60 mg/kg) was administered 4-6 hours before the radiation treatment and the total radiation dose varied between 0.1-4.0Gy in 1-4 fractions. Clinical trials are initiated in China for late-stage cancer patients targeting both primary tumors utilizing localized therapies such as 3DCRT/IMRT and metastases using TBI. Results: There is clear correlation between the cell death and the 5-ALA concentration/radiation dose. The therapeutic effect of RDT is demonstrated using an animal model where the volume of parotid tumors for the RT only group continued to grow after 3Gy irradiation while the RDT group showed a complete response with the same radiation dose. The preliminary clinical results showed encouraging clinical outcome. Conclusion: RDT is a novel treatment technique that may be developed into an effective cancer treatment modality. Further studies on the mechanisms of RDT and its potential clinical applications are warranted.

60 APPLIED LIFE SCIENCES↗

SU-D-201-02: Prediction of Delivered Dose Based On a Joint Histogram of CT and FDG PET Images

Purpose: To investigate whether pre-treatment images can be used in predicting microsphere distribution in tumors. When intra-arterial radioembolization using Y90 microspheres was performed, the microspheres were often delivered non-uniformly within the tumor, which could lead to an inefficient therapy. Therefore, it is important to estimate the distribution of microspheres. Methods: Early arterial phase CT and FDG PET images were acquired for patients with primary liver cancer prior to radioembolization (RE) using Y90 microspheres. Tumor volume was delineated on CT images and fused with FDG PET images. From each voxel (3.9×3.9×3.3 mm3) in the tumor, the Hounsfield unit (HU) from the CT and SUV values from the FDG PET were harvested. We binned both HU and SUV into 11 bins and then calculated a normalized joint-histogram in an 11×11 array.Patients also underwent a post-treatment Y90 PET imaging. Radiation dose for the tumor was estimated using convolution of the Y90 distribution with a dose-point kernel. We also calculated a fraction of the tumor volume that received a radiation dose great than 100Gy. Results: Averaged over 40 patients, 55% of tumor volume received a dose greater than 100Gy (range : 1.1 – 100%). The width of the joint histogram was narrower for patients with a high dose. For patients with a low dose, the width was wider and a larger fraction of tumor volume had low HU. Conclusion: We have shown the pattern of joint histogram of the HU and SUV depends on delivered dose. The patterns can predict the efficacy of uniform intra-arterial delivery of Y90 microspheres.

60 APPLIED LIFE SCIENCES↗

Commentary 2 to Cox and Little: radiation-induced oncogenic transformation: the interplay between dose, dose protraction, and radiation quality

There is now a substantial body of evidence for end points such as oncogenic transformation in vitro, and carcinogenesis and life shortening in vivo, suggesting that dose protraction leads to an increase in effectiveness relative to a single, acute exposure--at least for radiations of medium linear energy transfer (LET) such as neutrons. Table I contains a summary of the pertinent data from studies in which the effect is seen. [table: see text] This phenomenon has come to be known as the "inverse dose rate effect," because it is in marked contrast to the situation at low LET, where protraction in delivery of a dose of radiation, either by fractionation or low dose rate, results in a decreased biological effect; additionally, at medium and high LET, for radiobiological end points such as clonogenic survival, the biological effectiveness is independent of protraction. The quantity and quality of the published reports on the "inverse dose rate effect" leaves little doubt that the effect is real, but the available evidence indicates that the magnitude of the effect is due to a complex interplay between dose, dose rate, and radiation quality. Here, we first summarize the available data on the inverse dose rate effect and suggest that it follows a consistent pattern in regard to dose, dose rate, and radiation quality; second, we describe a model that predicts these features; and, finally, we describe the significance of the effect for radiation protection.

Review, Tutorial↗

Shielding Design for Prototype Generation-IV Sodium-Cooled Fast Reactor

A Prototype Generation-IV Sodium-cooled Fast Reactor (PGSFR) with 150 MWe power rating is being developed jointly by the Korea Atomic Energy Research Institute (KAERI) and Argonne National Laboratory (ANL). KAERI is responsible for the overall project with the ANL contributions integrated into the KAERI activities. Shielding concept of PGSFR was developed to ensure that the safety limit on internal structural damage and working personnel received dose is not exceeded. The first part evaluated the Displacement Per Atoms (DPA) and fast neutron fluence on the structures inside the reactor vessel, such as lower grid, Upper Internal Structure (UIS), barrel, Redan, and reactor vessels. The analysis determined the thickness of shields required to satisfy the DPA and fast fluence limit. The second part of the shielding analysis evaluated the radiation dose rate above the reactor head due to the primary sodium activation inside the reactor vessel. The analysis determined the necessary thickness of reactor head and additional shield to ensure that the dose rate received by personnel working on top of the reactor is below the safety limit. The last part of the shielding analysis investigated the dose rate received by personnel working near the secondary loop. The secondary sodium is activated inside the Intermediate heat exchanger (IHX). The activated secondary sodium flows out of the reactor vessel and emits high energy photons along the way. The shielding designs both inside the reactor vessel and around the pipes of the secondary loop were investigated. The shielding concept for the PGSFR was developed to minimize radiation exposure to plant personnel and the irradiation damage of the internal structural components. The damage of the internal structural components are mainly due to the loss of the ductility by the neutron irradiation, and the activated gammas of primary and secondary sodium coolants are the major radiation sources that are required to be shielded. Thicker and denser shielding structures are favorable to reduce the radiation dose and protect personnel who work in the plant; however, which enlarges the in-vessel space to accommodate the shielding structures. Thus, in order to install the shielding structures in a reasonable reactor to satisfy the DPA or dose rate limit size, the PGSFR shielding parameters were determined from the sensitivity study, which includes the compositions of the shielding materials and dimensions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-516: Investigation of a Novel Radiochromic Radiation Reporting System Utilizing the Reduction of Ferric Ion

Purpose To introduce and characterize a new “reverse-Fricke” radiation reporting system utilizing the reduction of ferric ions (Fe{sup 3+}) to ferrous ions (Fe{sup 2+}). Methods Two formulations of the radiochromic reporting system, referred to as A and B, were prepared for investigation. Formulation-A consisted of 14 mM 1,10-phenanthroline, 42 mM ethanol, and 57 mM ammonium ferric oxalate in water. Formulation-B consisted of 27 mM 1,10-phenanthroline, 42 mM ethanol, and 28 mM ammonium ferric oxalate in water. Solutions were prepared immediately prior to irradiation with a Cobalt-60 unit with radiation doses of 0, 1, 5, 10, 15, 20, and 25 Gy. The change in optical density over the visible range of 450–650 nm was measured using a spectrophotometer immediately after irradiation. The effective atomic numbers of the formulations were calculated using Mayneord’s formula. Results Ionizing radiation energy absorbed in the solutions causes the reduction of ferric ions (Fe{sup 3+}) into ferrous ions (Fe{sup 2+}), which then forms a 1:3 red colored complex with 1,10-phenanthroline ([(C{sub 1} {sub 2}H{sub 8}N{sup 2}){sub 3}Fe]{sup 2+}) that can be measured spectrophotometrically. The absorbance spectra of the resulting complex displayed a peak maximum at 512 nm with a greater change in absorbance for Formulation-B after receiving comparable radiation doses. The change in absorbance relative to dose exhibited a linear response up to 25 Gy for both Formulation-A (R{sup 2} = 0.98) and Formulation-B (R{sup 2} = 0.97). The novel formulations were also nearly water equivalent (Zeff = 7.42) with effective atomic numbers of 7.65 and 7.52 and mass densities within 0.2% of water. Conclusion Both formulations displayed visible Fe{sup 2+} complex formation with 1,10-phenanthroline after irradiation using a Cobalt-60 source. The higher sensitivity measured for Formulation-B is attributed to the increase in 1,10-phenanthroline concentration and the increase in the 1,10-phenanthroline to ammonium ferric oxalate ratio. Further investigation of this radiation reporting system in a 3D matrix material is encouraged. NSF GRFP Grant Award #LH-102SPS.

60 APPLIED LIFE SCIENCES↗

Deciphering decomposition pathways of high explosives with cryogenic X-ray Raman spectroscopy

We employed cryogenic X-ray Raman spectroscopy to investigate the early-stage decomposition of the high explosive molecule hexanitrohexaazaisowurtzitane (CL-20). By systematically varying the radiation dose under cryogenic conditions, we induced the decomposition of the molecule using ionizing radiation and observed the evolution of spectral features at the carbon, nitrogen, and oxygen K edges. Through extensive first-principles calculations, we identified key intermediates in the early stages of the decomposition process, resulting from C–C and C–N bond cleavage which leads to the opening of the internal cage structure. A detailed analysis of spectral trends and fingerprints provided evidence supporting N–NO 2 homolytic cleavage as the primary initial decomposition pathway. The combination of advanced core-level spectroscopy methods and state-of-the-art theoretical calculations enabled a comprehensive characterization of the molecular changes induced by controlled radiation dose exposures. In conclusion, our findings establish a benchmark for understanding the decomposition chemistry of high-explosive materials, offering important insights into their stability and reactivity under extreme conditions.

X-ray Raman spectroscopy↗

Recent Progress on the Stochastic Objective Decision Aide (SODA) Application

Idaho State University, in collaboration with Idaho National Laboratory, is engaged in development of a simple to use software application that utilizes stochastic techniques for the calculation of radiation doses associated with hypothetical radioactive material releases. This work is being performed through a grant from the U.S. Department of Energy (DOE) Nuclear Safety Research and Development (NSR and D) Program. Initial progress on the application was reported previously. Recent additions to the application are reported here. The Stochastic Objective Decision Aide (SODA) provides an easy to use software application to help decision makers support their judgment about the need or lack of need for safety structures, systems, and components. SODA is not intended to replace traditional design basis accident dose calculation methodology, nor is it intended to replace existing software used to perform formal dose consequence calculations. Rather, SODA is intended to supplement information obtained from existing codes to give a decision maker more information about an accident scenario. SODA also provides a simple method to perform parametric or sensitivity studies on individual input parameters. Non-reactor nuclear facilities operated under the approval authority of the US DOE use unmitigated hazard evaluations to determine if potential radiological doses associated with design basis events challenge dose evaluation guidelines. Unmitigated events that sufficiently challenge dose evaluation guidelines merit the selection of safety structures, systems, or components (SSCs) to prevent or mitigate the hazard. Dose consequence calculations traditionally involve use of the 'five-factor' formula: ST = MAR.DR.ARF.RF.LPF where ST is the source term (Bq), MAR is the total available material-at-risk (Bq), DR is the damage ratio (no units), ARF is the airborne release fraction (no units), RF is the respirable fraction (no units), and LPF is the leak path factor (no units). Potential radiation doses are then calculated using: CED = χ/Q.BR.ST.DCF (2) where CED is the committed effective dose (Sv), χ/Q is the plume dispersion (s/m{sup 3}), BR is the breathing rate (m{sup 3}/s), ST is the source term (Bq), and DCF is the dose conversion factor (Sv/Bq). Conservative single value input parameters are typically used to represent ARF, RF, LPF and BR. The traditional methodology, while conservative, can lead to skewed conclusions in the balance between cost and risk reduction resulting in over engineered systems with greater design, construction and operating costs. Rather than using a bounding single point value for each parameter in the dose consequence calculation, SODA uses distributions for some or all of the parameters. Each input parameter distribution is stochastically sampled and the resulting dose consequence calculation is repeated many times to develop a dose consequence distribution. The resulting distribution provides more information for the decision maker to rely upon when determining the need for safety SSCs. The SODA application was developed using MATLAB and it incorporates the use of Monte Carlo techniques as well as a graphical user interface (GUI). The application includes user selection of the governing distribution for parameters such as the MAR, DR, ARF, RF, LPF,χ/Q, BR, and DCF. While MATLAB was used for the development work, the application is distributed as a self-contained executable program. Features of the application include pull down menus with available distributions for the various parameters. The user has the option to plot the input parameter distribution that results from the random sampling process. The resulting dose consequence distribution is automatically analyzed to determine its similarity to well know distributions. This was done using the Bayesian Information Criterion method. If the resulting distribution is sufficiently similar to a well-known distribution, the application provides information about the distributions such as the mean value and other parameters. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MTL_TX: A Multi-Task Transformer Model for Improved Radiation Time-Series Estimation

Controlling radiation doses at potential radioactive facilities is critical to ensuring the safety of both personnel and the public. At the Thomas Jefferson National Accelerator Facility (JLab), multiple sensors are deployed around the three experimental halls to monitor key parameters, including single-beam current, energy levels, current leakage, and radiation values during accelerator operations. In this study, we developed a Multi-task Transformer model, MTL_TX, to accurately estimate radiation doses at sensor locations based on historical data, with the aim of enhancing safety in accelerator facilities and surrounding public areas. To improve estimation accuracy, we integrated two innovative components into the proposed model: hierarchical feature embedding (HFE) and multi-level decomposition attention (MDA). Additionally, the multi-task learning (MTL) framework effectively leverages correlations among multiple sensors, enabling individual estimations for each sensor. MTL_TX achieved outstanding results on data collected in 2018, with an MSE of 0.1464, an RMSE of 0.2353, and an R 2 score of 0.8584. Furthermore, when trained on 2018 data, MTL_TX exhibited excellent generalization capability to unseen datasets from 2016 to 2019, achieving an MSE of 0.1407, an RMSE of 0.2263, and an R 2 score of 0.8831. These results demonstrate a significant improvement over existing state-of-the-art models.

Transformer↗

Solar particle event predictions for manned Mars missions

Manned space missions to Mars require consideration of the effects of high radiation doses produced by solar particle events (SPE). Without some provision for protection, the radiation doses from such events can exceed standards for maximum exposure and may be life threatening. Several alternative ways of providing protection require a capability for predicting SPE in time to take some protective actions. The SPE may occur at any time during the eleven year solar cycle so that two year missions cannot be scheduled to insure avoiding them although they are less likely to occur at solar minimum. The present forecasts are sufficiently accurate to use for setting alert modes but are not accurate enough to make yes/no decisions that have major mission operational impacts. Forecasts made for one to two year periods can only be done as probabilistic forecasts where there is a chance of SPE occurring. These are current capabilities but are not likely to change significantly by the year 2000 with the exception of some improvement in the one to ten day forecasts. The effects of SPE are concentrated in solar longitudes near where their parent solar flares occur, which will require a manned Mars mission to carry its own small solar telescope to monitor the development of potentially dangerous solar activity. The preferred telescope complement includes a solar X-ray imager, a hydrogen-alpha scanner, and a solar magnetograph.

Heckman, Gary↗

Prospective Coronary Heart Disease Screening in Asymptomatic Hodgkin Lymphoma Patients Using Coronary Computed Tomography Angiography: Results and Risk Factor Analysis

Purpose: To prospectively investigate the coronary artery status using coronary CT angiography (CCTA) in patients with Hodgkin lymphoma treated with combined modalities and mediastinal irradiation. Methods and Materials: All consecutive asymptomatic patients with Hodgkin lymphoma entered the study during follow-up, from August 2007 to May 2012. Coronary CT angiography was performed, and risk factors were recorded along with leukocyte telomere length (LTL) measurements. Results: One hundred seventy-nine patients entered the 5-year study. The median follow-up was 11.6 years (range, 2.1-40.2 years), and the median interval between treatment and the CCTA was 9.5 years (range, 0.5-40 years). Coronary artery abnormalities were demonstrated in 46 patients (26%). Coronary CT angiography abnormalities were detected in nearly 15% of the patients within the first 5 years after treatment. A significant increase (34%) occurred 10 years after treatment (P=.05). Stenoses were mostly nonostial. Severe stenoses were observed in 12 (6.7%) of the patients, entailing surgery with either angioplasty with stent placement or bypass grafting in 10 of them (5.5%). A multivariate analysis demonstrated that age at treatment, hypertension, and hypercholesterolemia, as well as radiation dose to the coronary artery origins, were prognostic factors. In the group of patients with LTL measurements, hypertension and LTL were the only independent risk factors. Conclusions: The findings suggest that CCTA can identify asymptomatic individuals at risk of acute coronary artery disease who might require either preventive or curative measures. Conventional risk factors and the radiation dose to coronary artery origins were independent prognostic factors. The prognostic value of LTL needs further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-D-BRD-01: Image Guided SBRT II: Challenges ' Pitfalls

Stereotactic body radiation therapy (SBRT) has been effective treatment for the management of various diseases, which often delivers high radiation dose in a single or a few fractions. SBRT therefore demands precise treatment delivery to the tumor while sparing adjacent healthy tissue. Recent developments in image guidance enable target localization with increased accuracy. With such improvements in localization, image-guided SBRT has been widely adopted into clinical practice. In SBRT, high radiation dose is generally delivered with small fields. Therefore, it is crucial to accurately measure dosimetric data for the small fields during commissioning. In addition, image-guided SBRT demands accurate image localization to ensure safety and quality of patient care. Lately, the reports of AAPM TG 142 and TG 104 have been published and added recommendations for imaging devices that are integrated with the linear accelerator for SBRT. Furthermore, various challenges and potential pitfalls lie in the clinical implementation of image-guided SBRT. In this lecture, these challenges and pitfalls of image-guided SBRT will be illustrated and discussed from dosimetric, technical and clinical perspectives.Being a promising technique, image-guided SBRT has shown great potentials, and will lead to more accurate and safer SBRT treatments. Learning Objectives: To understand dosimetric challenges and pitfalls for IGRT application in SBRT. To understand major clinical challenges and pitfalls for IGRT application in SBRT. To understand major technical challenges and pitfalls for IGRT application in SBRT.

60 APPLIED LIFE SCIENCES↗

TH-AB-209-08: Next Generation Dedicated 3D Breast Imaging with XACT

Purpose: Exposure to radiation increases the risk of cancer. We have designed a new imaging paradigm, X-ray induced acoustic computed tomography (XACT). Applying this innovative technology to breast imaging, an X-ray exposure can generate a 3D acoustic image, which dramatically reduces the radiation dose to patients when compared to conventional breast CT. Methods: Theoretical calculations are done to determine the appropriate X-ray energy and ultrasound frequency in breast XACT imaging. A series of breast CT image along the coronal plane from a patient with calcifications in the breast tissue are used as the source image. HU value based segmentation is done to distinguish the skin, adipose tissue, glandular tissue, breast calcification, and chest bone from each CT image. X-ray dose deposition in each pixel is calculated based on the tissue type by using GEANT4 Monte Carlo toolkits. The initial pressure rise caused by X-ray energy deposition is calculated according to tissue properties. Then, the X-ray induced acoustic wave propagation is simulated by K-WAVE toolkit. Breast XACT images are reconstructed from the recorded time-dependent ultrasound waves. Results: For imaging a breast with large size (16cm in diameter at chest wall), the photon energy of X-ray source and the central frequency of ultrasound detector is determined as 20keV and 5.5MHz. Approximately 10 times contrast between a calcification and the breast tissue can be acquire from XACT image. The calcification can be clearly identified from the reconstructed XACT image. Conclusion: XACT technique takes the advantages of X-ray absorption contrast and high ultrasonic resolution. With the proposed innovative technology, one can potentially reduce radiation dose to patient in 3D breast imaging as compared with current x-ray modalities, while still maintaining high imaging contrast and spatial resolution.

60 APPLIED LIFE SCIENCES↗