Search NASA⌕ Search

SEARCH · Search NASA

Results for “READOUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

TinyTPC: A TEST STAND FOR LAr DOPING

TinyTPC is a small scale liquid-argon time projection chamber (LArTPC) that studies how photosensitive dopants can improve the energy resolution of low energy events in LArTPCs. Bench tests to resolve high voltage breakdown issues and to improve the low voltage system readout are described. Experimental data with a radioactive source of Th-228 for the calibration of the pixelated readout and the characterization of TinyTPC's energy resolution is explained. Provisional results from the addition of isobutylene (photosensitive dopant) and xenon (wavelength shifter) to liquid-argon (LAr) are also presented. Further steps to improve voltage system and enhance the data collection are discussed.

Rodriguez Thorne, Paloma↗

Real-time Anomaly Detection at the L1 Trigger of CMS Experiment

We present the preparation, deployment, and testing of an autoencoder trained for unbiased detection of new physics signatures in the CMS experiment Global Trigger (GT) test crate FPGAs during LHC Run 3. The GT makes the final decision whether to readout or discard the data from each LHC collision, which occur at a rate of 40 MHz, within a 50 ns latency. The Neural Network makes a prediction for each event within these constraints, which can be used to select anomalous events for further analysis. The GT test crate is a copy of the main GT system, receiving the same input data, but whose output is not used to trigger the readout of CMS, providing a platform for thorough testing of new trigger algorithms on live data, but without interrupting data taking. We describe the methodology to achieve ultra low latency anomaly detection, and present the integration of the DNN into the GT test crate, as well as the monitoring, testing, and validation of the algorithm during proton collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Intelligent Pixel Detectors: Towards a Radiation Hard ASIC with On-Chip Machine Learning in 28 nm CMOS

Detectors at future high energy colliders will face enormous technical challenges. Disentangling the unprecedented numbers of particles expected in each event will require highly granular silicon pixel detectors with billions of readout channels. With event rates as high as 40 MHz, these detectors will generate petabytes of data per second. To enable discovery within strict bandwidth and latency constraints, future trackers must be capable of fast, power efficient, and radiation hard data-reduction at the source. We are developing a radiation hard readout integrated circuit (ROIC) in 28nm CMOS with on-chip machine learning (ML) for future intelligent pixel detectors. We will show track parameter predictions using a neural network within a single layer of silicon and hardware tests on the first tape-outs produced with TSMC. Preliminary results indicate that reading out featurized clusters from particles above a modest momentum threshold could enable using pixel information at 40 MHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensor Co-design for $\textit{smartpixels}$

Pixel tracking detectors at upcoming collider experiments will see unprecedented charged-particle densities. Real-time data reduction on the detector will enable higher granularity and faster readout, possibly enabling the use of the pixel detector in the first level of the trigger for a hadron collider. This data reduction can be accomplished with a neural network (NN) in the readout chip bonded with the sensor that recognizes and rejects tracks with low transverse momentum (p$_T$) based on the geometrical shape of the charge deposition (``cluster''). To design a viable detector for deployment at an experiment, the dependence of the NN as a function of the sensor geometry, external magnetic field, and irradiation must be understood. In this paper, we present first studies of the efficiency and data reduction for planar pixel sensors exploring these parameters. A smaller sensor pitch in the bending direction improves the p$_T$ discrimination, but a larger pitch can be partially compensated with detector depth. An external magnetic field parallel to the sensor plane induces Lorentz drift of the electron-hole pairs produced by the charged particle, broadening the cluster and improving the network performance. The absence of the external field diminishes the background rejection compared to the baseline by $\mathcal{O}$(10%). Any accumulated radiation damage also changes the cluster shape, reducing the signal efficiency compared to the baseline by $\sim$ 30 - 60%, but nearly all of the performance can be recovered through retraining of the network and updating the weights. Finally, the impact of noise was investigated, and retraining the network on noise-injected datasets was found to maintain performance within 6% of the baseline network trained and evaluated on noiseless data.

Shekar, Danush [Illinois U., Chicago]↗

Enhancing ICARUS and REDTOP Software and Hardware: Event Generator Interface Development and Calorimeter Tile Prototype

ICARUS (Imaging Cosmic And Rare Underground Signals) is a liquid argon time projection chamber (LArTPC) detector that pursues the sterile neutrino, which relies on accurate simulations of neutrino-argon interactions. REDTOP (Rare Eta Decays To Observe new Physics) is a proposed low-energy, high-intensity meson factory designed to explore rare $\eta$/$\eta'$ meson decays and probe physics beyond the Standard Model. As a next-generation experiment, this requires both accurate simulations and innovative detector technologies. This project contributes to both ICARUS, from a simulation perspective, and REDTOP, from both a simulation and detection perspective, through the event generation of lepton-nucleon interactions and the physical enhancement of the calorimeter technology within the REDTOP detector. We developed an interface between ACHILLES (A CHIcago Land Lepton Event Simulator), a theory-driven lepton-level event generator, and GENIE, a robust event generator framework used for neutrino physics. By incorporating the precise theoretical cross-section calculations of ACHILLES into the experimental realism of GENIE, the interface allows for improved accuracy of neutrino-nucleon simulations, which can be adapted for the proton beam specifications of the REDTOP meson factory as well as for the ICARUS experiment. In parallel, we developed an improved prototype for the ADRIANO2 (A Dual Readout Integrally Active Non-segmented Option) dual-readout calorimeter tiles for the REDTOP detector. To improve the efficiency of the lead-glass tiles trapping Cherenkov light for energy reconstruction and particle identification, we optimized the application of a highly reflective coating. Through viscosity and thickness control, masking, and a custom spray technique, we refined the coating process to reduce surface defects and improve light yield. Together, these efforts strengthen the ICARUS neutrino program and REDTOP's capability of detecting rare decay events.

Visser, Erin [Michigan State U.] (ORCID:0009000184↗

Setup and Testing of PSEC5 ASIC Boards

The PSEC5 ASIC is a high-speed waveform sampling chip developed for precise measurements. This report presents the design review, test board configurations, and results from functional validation of the PSEC5 device. Key aspects examined include power integrity, voltage-controlled oscillator (VCO) behavior, SPI register functionality, clock division characteristics, readout performance, and analog biasing response. Tests were conducted across two boards under varied voltage conditions and signal configurations. Notable observations include robust VCO output, SPI communication irregularities, and anomalous readout conditions. The findings support design iterations for improved ASIC operability and firmware integration.

Fahey, Alexander [North Central Coll.]↗

Surrogate Neural Architecture Codesign Package (SNAC-Pack)

Neural architecture search (NAS) is a powerful approach for automating model design, but existing methods often optimize for accuracy alone or rely on proxy metrics such as bit operations (BOPs) that correlate poorly with hardware cost. This gap is particularly large for FPGA deployment, where cost is dominated by a multi-dimensional budget of lookup tables, DSPs, flip-flops, BRAM, and latency. We present the Surrogate Neural Architecture Codesign Package (SNAC-Pack), an open-source AutoML framework for hardware-aware neural architecture codesign and end-to-end FPGA deployment. SNAC-Pack runs a multi-objective global search with Optuna and NSGA-II, loading trials to a shared SQLite store that enables parallel workers across compute nodes. A hardware surrogate model outputs per-trial resource and latency estimates, avoiding the synthesis cost that would otherwise dominate the search loop. A local search stage then applies quantization-aware training (QAT) together with iterative magnitude pruning in a combined compression loop, after which the final model is synthesized to FPGA firmware via the hls4ml Python library. A YAML configuration and an optional agentic frontend let users run the pipeline on new datasets without modifying the framework. We demonstrate SNAC-Pack on jet classification at the Large Hadron Collider and superconducting qubit readout, discovering compact architectures that match or exceed strong baselines on the task metric while reducing FPGA resource utilization and, in the qubit readout case, reducing the design space exploration process from months of manual fine-tuning to hours of automated search.

Weitz, Jason [UC, San Diego]↗

Long-term stability-degradation analysis of DUNE SiPMs in Liquid Nitrogen

We developed a cryogenic photon readout system to monitor arrays of DUNE SiPMs operating at various over-voltages in liquid nitrogen (LN2) for over three months. Photoelectron signals were read out simultaneously via weak capacitive coupling to the micro-FEMB, a 32-channel charge sensitive readout board designed for 77 K to 300 K operation in liquid argon time projection chambers (LAr-TPCs). A waveform snippet acquisition scheme was implemented to capture waveform signals whenever they exceeded a predetermined trigger level; consequently, empty waveforms were discarded. Selected SiPM parameters were monitored to detect any deviations beyond statistical fluctuations. While some parameters exhibited ~1σ variations over the 3-month test period, there was no evidence of drift being enhanced when operating at 4 V or 5 V compared to a 3 V over-voltage. However, a discernible PDE drop was observed across all channels, which warrants further investigation. In addition, we demonstrated that our system can simultaneously read out single photons from a selected group of SiPMs at room temperature.

Tsang, Thomas [Brookhaven]↗

Quality Control of Silicon Sensor Modules for Particle Detectors

The High-Luminosity Large Hadron Collider (HL-LHC) will produce a higher rate of particle collisions than the current Large Hadron Collider (LHC), requiring significant upgrades to the Compact Muon Solenoid (CMS) to handle the increased amount of data. An important upgrade is the Phase-2 Outer Tracker Upgrade, which consists of 13,000 silicon sensor modules made of two parallel silicon sensors and readout electronics. These modules undergo careful quality control checks both during and after module assembly to ensure precise and reliable detector performance. This project focuses on precision testing for quality control of silicon sensor modules at Fermilab. Hands-on work includes visual inspection, current-voltage testing, module testing, and ultraviolet (UV) light exposure of modules showing abnormal current-voltage behavior. The ultraviolet exposure process improves the abnormal sensor readout data by placing the selected sensor side of the module directly under the UV light inside a controlled box. In addition to laboratory testing and ultraviolet experiments, I developed a Python-based data tool that connects to a module database and allows selected testing conditions and module information to be retrieved and displayed efficiently. These different testing procedures, experimental processes, and computational tools support the broader goal of identifying module issues and improving modules that will be used in the CMS Outer Tracker Phase-2 Upgrade.

Siddiqui, Hooriya [DuPage Coll.; Fermilab] (ORCID:↗

Graphical User Interface for a Biasing Board for the PSEC6

The PSEC6 is an application-specific integrated circuit (ASIC) designed for a readout system for a large area picosecond photodetector (LAPPD). The PSEC6 is currently in fabrication and pending testing. The testing system for the PSEC5, the previous iteration of the ASIC, required expensive and non-portable equipment, because the ASIC needs twelve adjustable reference voltages. The new testing system consists of an low-cost, open-source, cross-platform graphical user interface (GUI), a digital system, and a biasing board. The digital system is the interface between the GUI and biasing board, and can be implemented on a microcontroller or field-programmable gate array (FPGA). The biasing board contains twelve digital-to-analog converters (DACs) that are configurable via the GUI, which gives users the ability to write voltage values to all or specific DACs. The GUI was developed in C on Linux using the widget library GTK4 and cross-compiled for Windows compatibility. I2C and SPI protocols were implemented on an Adafruit Feather ESP32-S3 microcontroller to write commands to the DACs and PSEC6. A hardware implementation of the I2C protocol is in development on an FPGA. Since LAPPDs will be used by the Accelerator Neutrino Neutron Interaction Experiment (ANNIE) at Fermilab, the PSEC6 testing system in this internship project can potentially benefit future neutrino research. The project is relevant to the Department of Energy’s microelectronics mission, because the PSEC6 is an ASIC that will handle fast time signals arriving from the detector for readout. It also provided experience with building a cross-platform user interface, practicing digital design and implementation in hardware description language (HDL), and using simulations to inform new design iterations.

Guerrero, Sasha Camila [North Central Coll.]↗

Online and Offline Data Quality Monitoring for the Mu2e Calorimeter

This thesis presents the design, implementation, and validation of a calorimeter Data Quality Monitoring (DQM) toolchain for the Mu2e experiment at Fermilab. Mu2e searches for charged lepton flavor violation via coherent muon-to-electron conversion in the field of an aluminum nucleus, $\mu^- Al \rightarrow e^-Al$, a process whose observation would constitute clear evidence of physics beyond the Standard Model. Achieving target sensitivity requires stringent control of detector performance and data integrity during acquisition, as subtle issues in readout configuration, data formatting, or electronics behavior can compromise reconstruction and bias downstream analyzes. To address these challenges, this work develops a multi-layer DQM approach spanning both raw data validation and reconstructed digi-level diagnostics. At the low level, a fragment analysis component performs word- and bit-field decoding of calorimeter readout blocks, enabling sanity checks of the expected structure and producing detailed error and integrity statistics useful for commissioning and troubleshooting. At the digi level, the CaloDigiDQM analyzer is implemented within the art framework and transforms each CaloDigiCollection into a structured hierarchy of ROOT histograms designed for fast drill-down diagnostics. The module generates coherent monitoring views at global, disk, board, and channel granularity, including occupancy, waveform-derived features (baseline, RMS, peak amplitude and position), and left-right sensor consistency metrics. Detector-aware channel-to-electronics mapping is performed through the conditions system (CaloDAQMap), ensuring that diagnostics remain aligned with hardware identifiers used in operations. For end-to-end testing without reliance on live DAQ data, a synthetic CaloDigi producer is developed to generate realistic waveforms with controlled noise and pulse shapes. The resulting system supports both offline ROOT-file production and online operation, including optional histogram streaming through otsdaq via ots::HistoSender. This toolchain provides a practical and scalable foundation for calorimeter commissioning and stable data collection, enabling early detection of anomalies and reducing operational risk for Mu2e.

Vakulenko, Mark [Drew U.] (ORCID:0009000276197818)↗

TTDAQ: A Continuous Flow, Timing and Trigger DAQ System

Final Scientific/Technical Report for DOE Award DE-SC0019581, “TTDAQ: A Continuous Flow, Timing and Trigger DAQ System.” The report summarizes Telluric Labs’ Phase II STTR work developing silicon-photonic building blocks for a software-defined, continuous-flow, trigger-less data acquisition system for next-generation high-energy and nuclear-physics detectors. The project focused on radiation-hard photonic integrated circuits, remote optical illumination, dense wavelength-division multiplexing, and a differential microring-resonator transceiver architecture designed to improve high-speed optical link stability and bandwidth. The report describes project objectives, technical accomplishments, AIM Photonics tape-outs, bench characterization, radiation-hardness testing, deferred integration work, and potential applications beyond physics readout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A virtual Frisch-grid geometry-based CZT gamma detector for in-field radioisotope identification

Here, we present a Virtual Frisch-Grid geometry-based CZT gamma detector developed for identifying different radioisotopes over an energy range from a few keV up to 2 MeV, and useful for efficient characterization of CZT crystals. The detector is built with a 3 x 3 matrix of CZT crystals, each measuring approximately 6 mm x 6 mm x 15 mm. The charge generated within the sensor’s active volume is read out via an anode connected directly to the AVG3_Dev integrated circuit. A current signal induced by charge drift is collected on side pads of the crystals, enabling reconstruction of a 3D interaction position. This paper discusses the design, development, and performance of the standalone, mobile detector system, which integrates the AVG3_Dev readout IC developed at Brookhaven National Laboratory, a high-speed FPGA-based with per-channel digital signal processing, and embedded system capabilities. The device is compact, battery-powered, and supports wireless data streaming, making it suitable for field operations for radioisotope identification.

47 OTHER INSTRUMENTATION↗

First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber

We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH 4 ) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200–1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.

47 OTHER INSTRUMENTATION↗

ETROC1: the first full chain precision timing prototype ASIC for CMS MTD endcap timing layer upgrade

We present the design and characterization of the first fullchain precision timing prototype ASIC, named ETL Readout Chipversion 1 (ETROC1) for the CMS MTD endcap timing layer (ETL)upgrade. The ETL utilizes Low Gain Avalanche Diode (LGAD) sensors todetect charged particles, with the goal to achieve a time resolutionof 40–50 ps per hit, and 30–40 ps per track with hits from twodetector layers. The ETROC1 is composed of a 5 × 5 pixelarray and peripheral circuits. The pixel array includes a4 × 4 active pixel array with an H-tree shaped networkdelivering clock and charge injection signals. Each active pixel iscomposed of various components, including a bump pad, a chargeinjection circuit, a pre-amplifier, a discriminator, adigital-to-analog converter, and a time-to-digital converter. Thesecomponents play essential roles as the front-end link in processingLGAD signals and measuring timing-related information. Theperipheral circuits provide clock signals and readoutfunctionalities. The size of the ETROC1 chip is7 mm× 9 mm. ETROC1 has been fabricated in a 65 nmCMOS process, and extensively tested under stimuli of chargeinjection, infrared laser, and proton beam. The time resolution ofbump-bonded ETROC1 + LGAD chipsets reaches 42–46 ps per hit in thebeam test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam test performance studies of CMS Phase-2 Outer Tracker module prototypes

A new tracking detector will be installed as part of thePhase-2 upgrade of the CMS detector for the high-luminosity LHC era.This tracking detector includes the Inner Tracker, equipped withsilicon pixel sensor modules, and the Outer Tracker, consisting ofmodules with two parallel stacked silicon sensors. The Outer Trackerfront-end ASICs will be able to correlate hits from chargedparticles in these two sensors to perform on-module discriminationof transverse momenta (p$_{T}$). The p$_{T}$information is generated at a frequency of 40 MHz and will be usedin the Level-1 trigger decision of CMS. Prototypes of theso-called 2S modules were tested at the Test Beam Facility at DESYHamburg between 2019 and 2020. These modules use the finalfront-end ASIC, the CMS Binary Chip (CBC), and for the firsttime the Concentrator Integrated Circuit (CIC), optical readoutand on-module power conversion. In total, seven modules were tested,one of which was assembled with sensors irradiated with protons. Animportant aspect was to show that it is possible to read out modulessynchronously. A cluster hit efficiency of about 99.75 % wasachieved for all modules. The CBC p$_{T}$ discriminationmechanism has been verified to work together with the CIC andoptical readout. The measured module performance meets therequirements for operation in the upgraded CMS tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmic axions revealed via amplified modulation of the ellipticity of a laser

We propose a new axion dark matter detection strategy that employs optical readout of laser beam ellipticity modulations caused by axion-induced electric fields in a microwave cavity, using electro-optic (EO) crystals, enhanced by externally injected radio-frequency (rf) power. Building upon the variance-based probing method [Phys. Rev. D 107, 103005 (2023).], we extend this concept to the optical domain: A weak probe laser interacts with an EO crystal coupled to the resonant microwave cavity field at cryogenic temperatures, and the axion-induced electric field is revealed through induced ellipticity. The injected rf signal coherently interferes with that of the axion field, amplifying the optical response and significantly improving sensitivity. While our EO-based method employs a Fabry-Pérot resonator, we do not require Michelson interferometers. Our method, hence, enables compact, high-frequency axion searches, across the 0.5–50 GHz range. Operating at cryogenic temperatures not only suppresses thermal backgrounds, but, critically, allows the probing method to mitigate the quantum noise. This approach offers a scalable path forward for axion detection over the ∼(few−200) μ⁢eV mass range—covering the preferred parameter space for the postinflationary Peccei-Quinn axion dark matter—using compact, tunable systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗