Search NASA⌕ Search

SEARCH · Search NASA

Results for “Real Time Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Machine Learning-Assisted Distribution System Network Reconfiguration Problem

High penetration from volatile renewable energy resources in the grid and the varying nature of loads raise the need for frequent line switching to ensure the efficient operation of electrical distribution networks. Operators must ensure maximum load delivery, reduced losses, and the operation between voltage limits. However, computations to decide the optimal feeder configuration are often computationally expensive and intractable, making it unfavorable for real-time operations. This is mainly due to the existence of binary variables in the network reconfiguration optimization problem. To tackle this issue, we have devised an approach that leverages machine learning techniques to reshape distribution networks featuring multiple substations. This involves predicting the substation responsible for serving each part of the network. Hence, it leaves simple and more tractable Optimal Power Flow problems to be solved. This method can produce accurate results in a significantly faster time, as demonstrated using the IEEE 37-bus distribution feeder. Compared to the traditional optimization-based approaches, a feasible solution is achieved approximately ten times faster for all the tested scenarios.

deep neural networks↗

Flexibility Reserve in Power Systems: Definition and Stochastic Multi-Fidelity Optimization

This paper defines flexibility reserve trajectory as a single reserve product that not only supplies the energy imbalance in real-time operation but also the resulting ramping requirements by embedding the flexible ramping trajectories as time derivative of the reserve trajectories. Further, a stochastic optimization model is proposed for multi-fidelity co-optimization of energy and flexibility reserve in day-ahead power systems operation. The proposed model integrates operation decisions with different levels of modeling fidelity in a single stochastic optimization problem. More specifically, day-ahead energy trajectories, day-ahead flexibility reserve capacity trajectories, and real-time flexibility reserve deployment trajectories are modeled by Bernstein polynomials with different degrees as required to match the load and renewable generation with different levels of variability in day-ahead and real-time operations. The proposed model is implemented on the IEEE reliability test system using load and solar generation data of California ISO, where the numerical results demonstrate that the proposed model schedules a reserve capacity that more accurately matches the real-time energy imbalance and ramping requirements of net-load, while reducing the total operation cost of the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber-Physical Dynamic System (CPDS) Modeling for Frequency Regulation and AGC Services of Distributed Energy Resources

The substantial integration of renewable energy brings significant challenges to balance the system in real time because of the variability and intermittency of renewable power. For the reliable system operation, the frequency regulation service is used to stabilize the system frequency through automatically balancing the system generation and load. On one hand, with the substantially increasing deployment of renewable energy in electricity system, the requirement of frequency regulation (FR) services increases significantly. On the other hand, the current main resource of FR services, the controllable conventional generation, is continuously decreasing in the system generation mix. This means that in the future high renewable penetration power system, additional and alternative reliable FR services providers such as distributed energy storage (DES) resources should be explored. Although the capability of utility-scale energy storage to provide FR services has been demonstrated, the integrated control and dynamic modeling of distributed energy resource (DER) providing frequency regulation grid services has been rarely explored. There are several challenges to adopt DERs to provide reliable grid services as illustrated in FERC 755. First, the distributed installation of DES requires a comprehensive cyber-physical dynamic system (CPDS) modeling to fully consider the impacts of the communication latency variability on its real time FR provision capability. Unlike the conventional generators, there are two-layer communication between DERs and system operators which increase the communication delay. Second, unlike the conventional generators whose dynamic models have been comprehensively studied, the difference among individual DER components' power-dynamic characteristic brings challenges in the accurate dynamic AGC modeling of its power-frequency relationship. Third, the temporal dependent state of charge uncertainty of DERs challenges DERs' power and frequency regulation capacities scheduling in the look-ahead generation scheduling. Therefore, the aggregator should optimize the frequency regulation provision from individual DER in real time. To overcome these challenges, this project proposes a cyber-physical dynamic system (CPDS) model to handle the uncertainty of DERs two-layer communication latency and power dynamics. The variability of DERs' communication delay and dynamic constraints will be comprehensively modeled. The DERs' AGC model with communication delay is designed to validate DESs' frequency regulation services. Like current performance-based frequency regulation evaluation, the delivery of DERs' frequency regulation will be assessed through post-analysis of the actual AGC response with respect to the AGC control signal from system operators. Consequently, the reliability improvement with DERs providing reliable frequency regulation services can be evaluated from a comprehensive perspective considering all the dynamics of communication and power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization of 3D controlled ELM-free state with recovered global confinement for KSTAR with n = 1 resonant magnetic field perturbation

Mitigation of deleterious heat flux from edge-localized modes (ELMs) on fusion reactors is often attempted with 3D perturbations of the confining magnetic fields. However, the established technique of resonant magnetic perturbations (RMPs) also degrades plasma performance, complicating implementation on future fusion reactors. Here, we introduce an adaptive real-time control scheme on the KSTAR tokamak as a viable approach to achieve an ELM-free state and simultaneously recover high-confinement (βN ~ 1.91, β p ~ 1.53, and H 98 ~ 0.9), demonstrating successful handling of a volatile complex system through adaptive measures. We show that, by exploiting a salient hysteresis process to adaptively minimize the RMP strength, stable ELM suppression can be achieved while actively encouraging confinement recovery. This is made possible by a self-organized transport response in the plasma edge which reinforces the confinement improvement through a widening of the ion temperature pedestal and promotes control stability, in contrast to the deteriorating effect on performance observed in standard RMP experiments. These results establish the real-time approach as an up-and-coming solution toward an optimized ELM-free state, which is an important step for the operation of ITER and reactor-grade tokamak plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of an integrated core–edge scenario using the super H-mode

An optimized pedestal regime called the super-H (SH) mode is leveraged to couple a fusion relevant core plasma with a high density scrape-off layer appropriate for realistic reactor power exhaust solutions. Recent DIII-D experiments have expanded the operating space of the SH regime using advanced control algorithms and investigated optimization of impurity seeding, deuterium gas puffing, and 3D magnetic perturbations. Simultaneous real-time control of the pedestal density and radiated power with in-vessel coils and nitrogen seeding enable optimal coupled divertor and pedestal conditions. Four case studies are analysed with varied levels of radiated power in the divertor volume ranging from 0 (no seeding) to 8.5 MW radiated from carbon and nitrogen emission. Plasmas with a 4.5 MW radiated power target establish a radiative mantle, leading to divertor temperatures of ~16 eV while maintaining SH-mode, and with only marginal impact on the pedestal and core performance. Increased levels of N 2 seeding with a 7.5 MW radiated power target facilitate detachment onset and divertor temperatures <5 eV, with no degradation in stored energy and the operational point remaining inside the SH-mode channel for $ > 2.5{\tau }_{\text{E}}$. Finally, a 8.5 MW radiated power target leads to partial detachment, which is so far associated with the loss of access to SH-mode pedestal conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimized Dispatch of Distributed Energy Resources for Resiliency and Power Quality Improvements at the Grid-Edge

Distributed Energy Resources (DERs) installed on low-voltage distribution systems, both utility-owned and nonutility owned may be employed to make improvements to system resiliency and power quality, in addition to simply serving load demand. By selectively dispatching active and reactive power from these existing DERs, improvements in voltage profiles and service availability during adverse events may be achieved. Further benefits can be gained by optimally choosing which DERs to dispatch power from, and the distribution of power from those DERs. For a given operating condition, using Linear Programming methods, optimal power dispatch values for individual DERs can be determined, while considering variables such as voltage gains, losses in the lines and the DERs, and DER reserve capacities. One such optimization technique is developed in this paper, and results from a real-time simulation study on a modified IEEE 13-bus distribution system with three DERs, are being presented. The operation of the optimized DER selection and dispatch algorithm is shown during normal operation of the transmission system when the DERs operate in grid-connected mode. Similar analyses can drive decision making during transmission system failure when the DERs operate in grid-forming or islanded mode.

Chowdhury, Prithwiraj Roy↗

Real-Time Alpine Measurement System Using Wireless Sensor Networks

Monitoring the snow pack is crucial for many stakeholders, whether for hydro-power optimization, water management or flood control. Traditional forecasting relies on regression methods, which often results in snow melt runoff predictions of low accuracy in non-average years. Existing ground-based real-time measurement systems do not cover enough physiographic variability and are mostly installed at low elevations. We present the hardware and software design of a state-of-the-art distributedWireless Sensor Network (WSN)-based autonomous measurement system with real-time remote data transmission that gathers data of snow depth, air temperature, air relative humidity, soil moisture, soil temperature, and solar radiation in physiographically representative locations. Elevation, aspect, slope and vegetation are used to select network locations, and distribute sensors throughout a given network location, since they govern snow pack variability at various scales. Three WSNs were installed in the Sierra Nevada of Northern California throughout the North Fork of the Feather River, upstream of the Oroville dam and multiple powerhouses along the river. The WSNs gathered hydrologic variables and network health statistics throughout the 2017 water year, one of northern Sierra’s wettest years on record. These networks leverage an ultra-low-power wireless technology to interconnect their components and offer recovery features, resilience to data loss due to weather and wildlife disturbances and real-time topological visualizations of the network health. Data show considerable spatial variability of snow depth, even within a 1 km 2 network location. In conclusion, combined with existing systems, these WSNs can better detect precipitation timing and phase in, monitor sub-daily dynamics of infiltration and surface runoff during precipitation or snow melt, and inform hydro power managers about actual ablation and end-of-season date across the landscape.

47 OTHER INSTRUMENTATION↗

Creating an Advanced Sensor Network to calculate real-time, mass-weighted flue gas composition and air heater leakage of a coal-fired utility boiler under dynamic operating conditions

Utilization of renewable energy sources to minimize the environmental impact of energy production has changed the way utility boilers operate, requiring frequent load cycling between full load and partial loads as low as 30%. Dynamic operation of coal-fired utility boilers significantly reduces boiler efficiency when compared to steady state at full load. Data-driven plant optimization has shown success with coal-fired utility boilers under dynamic operating conditions. The purpose of this work was to create an Advanced Sensor Network (ASN) to provide more extensive real-time data to inform dynamic plant optimization of Net Unit Heat Rate (NUHR). The ASN consists of gas sampling grids in the convective pass of the boiler and downstream of the air heater. These sampling grids allow for quantification of spatial variation of flue gas within the boiler and calculation of mass-weighted composition of flue gas through the combination of composition, velocity, and temperature measurements. The comparison of O 2 between the inlet and outlet of the air heater is used to calculate air leakage in real time. Flue gas composition and air heater leakage are both important factors in boiler efficiency and NUHR. Further, the results of this work support the value of mass-weighted averages for determining flue gas composition accurately. The measurements from the ASN show increased composition stratification during dynamic operation, with an average standard deviation 38% higher than observed during steady-state operation. Air heater leakage was also observed to increase from 2.8% to 5.1% following a load change. Prior to the installation of the ASN, these data would not have been available for dynamic control. These real-time data will be leveraged to calculate and optimize for NUHR during dynamic operation in future work.

42 ENGINEERING↗

SU-F-T-592: A Delivery QA-Free Approach for Adaptive Therapy of Prostate Cancer with Static Intensity Modulated Radiotherapy

Purpose: Clinical implementations of adaptive radiotherapy (ART) are limited mainly by the requirement of delivery QA (DQA) prior to the treatment. Small segment size and small segment MU are two dominant factors causing failures of DQA. The aim of this project is to explore the feasibility of ART treatment without DQA by using a partial optimization approach. Methods: A retrospective simulation study was performed on two prostate cancer patients treated with SMLC-IMRT. The prescription was 180cGx25 fractions with daily CT-on-rail imaging for target alignment. For each patient, seven daily CTs were selected randomly across treatment course. The contours were deformablely transferred from the simulation CT onto the daily CTs and modified appropriately. For each selected treatment, dose distributions from original beams were calculated on the daily treatment CTs (DCT plan). An ART plan was also created by optimizing the segmental MU only, while the segment shapes were preserved and the minimum MU constraint was respected. The overlaps, between PTV and the rectum, between PTV and the bladder, were normalized by the PTV volume. This ratio was used to characterize the difficulty of organs-at-risk (OAR) sparing. Results: Comparing to the original plan, PTV coverage was compromised significantly in DCT plans (82% ± 7%) while all ART plans preserved PTV coverage. ART plans showed similar OAR sparing as the original plan, such as V40Gy=11.2cc (ART) vs 11.4cc (original) for the rectum and D10cc=4580cGy vs 4605cGy for the bladder. The sparing of the rectum/bladder depends on overlap ratios. The sparing in ART was either similar or improved when overlap ratios in treatment CTs were smaller than those in original plan. Conclusion: A partial optimization method is developed that may make the real-time ART feasible on selected patients. Future research is warranted to quantify the applicability of the proposed method.

60 APPLIED LIFE SCIENCES↗

Operational and Strategic Implementation of Dynamic Line Rating for Optimized Wind Energy Generation Integration

One primary goal of rendering today’s transmission grid “smarter” is to optimize and better manage its power transfer capacity in real time. Power transfer capacity is affected by three main elements: stability, voltage limits, and thermal ratings. All three are critical, but thermal ratings represent the greatest opportunity to quickly, reliably and economically utilize the grid’s true capacity. With the “Smarter Grid”, new solutions have been sought to give operators a better grasp on real time conditions, allowing them to manage and extend the usefulness of existing transmission infrastructure in a safe and reliable manner. The objective of the INL Wind Program is to provide industry a Dynamic Line Rating (DLR) solution that is state of the art as measured by cost, accuracy and dependability, to enable human operators to make informed decisions and take appropriate actions without human or system overloading and impacting the reliability of the grid. In addition to mitigating transmission line congestion to better integrate wind, DLR also offers the opportunity to improve the grid with optimized utilization of transmission lines to relieve congestion in general. As wind-generated energy has become a bigger part of the nation’s energy portfolio, researchers have learned that wind not only turns turbine blades to generate electricity, but can cool transmission lines and increase transfer capabilities significantly, sometimes up to 60 percent. INL’s DLR development supports EERE and The Wind Energy Technology Office’s goals by informing system planners and grid operators of available transmission capacity, beyond typical Static Line Ratings (SLR). SLRs are based on a fixed set of conservative environmental conditions to establish a limit on the amount of current lines can safely carry without overheating. Using commercially available weather monitors mounted on industry informed custom brackets developed by INL in combination with Computational Fluid Dynamics (CFD) enhanced weather analysis and DLR software, INL’s project offers the potential of safely providing line ampacities up to 40 percent or more above existing SLRs, by using real time information rather than overly conservative SLR.

17 WIND ENERGY↗

Teeport: Break the Wall Between the Optimization Algorithms and Problems

Optimization algorithms/techniques such as genetic algorithm, particle swarm optimization, and Gaussian process have been widely used in the accelerator field to tackle complex design/online optimization problems. However, connecting the algorithm with the optimization problem can be difficult, as the algorithms and the problems may be implemented in different languages, or they may require specific resources. We introduce an optimization platform named Teeport that is developed to address the above issues. This real-time communication-based platform is designed to minimize the effort of integrating the algorithms and problems. Once integrated, the users are granted a rich feature set, such as monitoring, controlling, and benchmarking. Some real-life applications of the platform are also discussed.

97 MATHEMATICS AND COMPUTING↗

Quantum Computing – Real-Time Data Processing from a Dilution Refrigerator

This poster presents a real-time data visualization system for monitoring and displaying data from a Bluefors control unit connected to a dilution refrigerator. The goal is to provide an aesthetically pleasing and user-friendly web-based interface that continuously updates and displays critical data such as temperature and flow rates at various points within the refrigerator. Leveraging WebSocket technology, the system establishes multiple connections to the dilution refrigerators, enabling simultaneous monitoring of several units. The interactive webpage dynamically updates the data, providing researchers and operators with instant insights into the system's performance. The system's ability to stream and visualize data in real-time enhances the understanding of the dilution refrigerator's behavior, aiding in optimizing its operation and ensuring efficient scientific experiments. The application's web-based nature makes it easily accessible from any device with internet connectivity, promoting seamless collaboration and remote monitoring capabilities. Overall, this poster offers a comprehensive solution for real-time data visualization and analysis of dilution refrigerators, catering to the needs of researchers and scientists working in low-temperature physics and quantum computing fields.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A precise non-invasive blood glucose measurement system using NIR spectroscopy and Huber’s regression model

Diabetes is one of the prominent diseases around the world. Presently, invasive techniques need a finger prick blood sample . A repetitively painful procedure that produces the chance of infection. To resolve this issue, non-invasive measurement approach is proposed. In this paper, an efficient NIR wave based optical detection system is proposed with optimized post-processing regression model. After real-time data analysis, it has been found that the coefficient of determination (R{sup 2}) is improved with the value of 0.9084 using proposed regression model. Mean absolute derivative is also increased with 3.87 mg/dl corresponding to predicted blood glucose concentration. Mean absolute relative difference has exceeded to 3.25%, and average error is improved with 3.77% using proposed regression model. Average accuaracy has been analyzed 94–95% for predicted blood glucose concentration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synergistic data analytics for electromechanical oscillation in electric power systems

Accurate real-time estimation of the four electromechanical oscillation properties, i.e., dominant oscillation modes, mode shapes, participation factors, and coherent groups, is of great importance to assess and mitigate potential electromechanical oscillations in interconnected power systems. While eigenvalue analysis can realize such estimation, it requires precise linearized dynamic models and accurate parameters, which are highly difficult to obtain in practice. Data fusion-based modal estimation methods can extract the properties of electromechanical oscillations from measurement data without the power system model and parameters, but most of the time only one or two property assessments can be accomplished each time. To overcome this challenge, this paper presents a synergistic data analytics solution to characterize the dynamic behaviors of electromechanical oscillations from real-time measurement data. Here, the proposed method uses optimized variable projection, and it is capable of estimating all four electromechanical oscillation behavior properties from measured responses. Case studies are performed using the simulated measurement data of a 16-generator 68-bus test system and the field measurements collected by the PMUs deployed in the Yunnan Power Grid. The results demonstrate that the proposed synergistic data analytics solution can achieve satisfactory performance in capturing the properties of electromechanical oscillations from measurement data and exhibit strong robustness against measurement noise when compared with existing measurement-based methods.

42 ENGINEERING↗

Online eco-routing for electric vehicles using combinatorial multi-armed bandit with estimated covariance

Identifying energy-efficient routes in real-time has significant implications for the energy-optimal operations of electric vehicles (EVs). Here, this study proposes a novel model for EV online eco-routing problem, which obtains the minimal expected energy consumption paths (MECPs) for multiple origin-destination (OD) pairs simultaneously. Specifically, we formulate the routing problem as a bandit problem and solve it with online algorithms. We extend the algorithms by implementing a path elimination mechanism to reduce the candidate path set and introducing the variance and covariance of the energy consumption to reduce the uncertainties. The numerical results show that the proposed algorithms can efficiently obtain near-optimal MECPs, and the solution is significantly better than the widely used shortest trip time path algorithm (STTP) and shortest trip distance path algorithm (SDP). The variation considering link energy covariance and path elimination generates paths that save 4.1% of energy compared to the SDP and 5.4% to the STTP.

33 ADVANCED PROPULSION SYSTEMS↗

Refining Jets for CMS Run 3 using Fast Simulation

As the LHC moves into its high-luminosity phase, the CMS experiment must handle more complex data collected at much higher rates. While the Geant4-based simulation application (FullSim) provides highly accurate simulation to complement real data, FullSim’s intensive consumption of computing resources becomes an increasing liability as the rates increase, while faster tools offer an advantage. The fast MC production application (FastSim) delivers a complete simulation with a factor of 10 speedup over FullSim, but introduces inaccuracies in some observables. A specialized refinement method, Fast Perfekt, employs machine learning to improve the accuracy of FastSim. An initial report of this work focused on the refinement of jet flavor tagging observables. This article presents an update on the refinement, focusing on PUPPI jets with Run 3 data-taking conditions. Refinement is extended to include jet transverse momentum as well as its propagation to missing transverse momentum. A gridbased framework and real-time monitoring system have been developed to facilitate optimization and scaling of the refinement to a large number of target variables.

Güngördü, Açelya Deniz [Istanbul Tech. U.]↗

Optimisation of the blank shape for micro deep drawing of rectangular parts

In this investigation the blank shape for micro deep drawing of rectangular parts was for the first time optimized using FEM method with consideration of the real process conditions in micro forming, i.e. the coefficient of friction and the flow curves of thin foils. The acquired optimized blank shape was then validated by applying it to experiments. For both numerical and experimental investigations a punch with a section of 2x1 mm{sup 2} was used. Aluminum Al99.5 with a sheet thickness of 20 {mu}m was used as blank material in this investigation. A flange free drawn part was successfully obtained from experiment using the blank shape and blank holder force optimized using FEM.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An Introduction to the Federated Architecture for Secure and Transactive Distributed Energy Management Solutions (FAST-DERMS)

Deployment and capability of distributed energy resources (DER) in power systems is growing rapidly. These resources present an opportunity for low-cost provision of energy and grid services. The Federal Energy Regulatory Commission recently provided rulings to enable market participation of these distribution-connected resources, but the prevailing strategies for their management may not scale well to meet future needs. This paper introduces the Federated Architecture for Secure and Transactive Distributed Energy Management Solutions (FAST-DERMS) which was designed to address this need. In it we describe the architectural features of the approach, and a reference controls implementation employing a hierarchical coordination that includes stochastic optimization, model predictive control, and a simple real-time management scheme. Sample results from simulation show firm transmission-level service provision measured at the distribution substation.

grid architecture↗