Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

LISA Technology Development at GSFC

The prime focus of LISA technology development efforts at NASA/GSFC has been in LISA interferometry, specifically in the area of laser frequency noise mitigation. Laser frequency noise is addressed through a combination of stabilization and common-mode rejection. Current plans call for two stages of stabilization, pre-stabilization to a local frequency reference and further stabilization using the constellation as a frequency reference. In order for these techniques to be used simultaneously, the pre-stabilization step must provide an adjustable frequency offset. Here, we report on a modification to the standard modulation/demodulation techniques used to stabilize to optical cavities that generates a frequency-tunable reference from a fixed-length cavity. This technique requires no modifications to the cavity itself and only minor modifications to the components. The measured noise performance and dynamic range of the laboratory prototype meets the LISA requirements.

Thorpe, James Ira↗

LISA Beyond Einstein: From the Big Bang to Black Holes. LISA Technology Development at GSFC

This viewgraph presentation reviews the work that has been ongoing at the Goddard Space Flight Center (GSFC) in the development of the technology to be used in the Laser Interferometer Space Antenna (LISA) spacecrafts. The prime focus of LISA technology development efforts at NASA/GSFC has been in LISA interferometry. Specifically efforts have been made in the area of laser frequency noise mitigation. Laser frequency noise is addressed through a combination of stabilization and common-mode rejection. Current plans call for two stages of stabilization, pre-stabilization to a local frequency reference and further stabilization using the constellation as a frequency reference. In order for these techniques to be used simultaneously, the pre-stabilization step must provide an adjustable frequency offset. This presentation reports on a modification to the standard modulation/demodulation technique used to stabilize to optical cavities that generates a frequency-tunable reference from a fixed length cavity. This technique requires no modifications to the cavity itself and only minor modifications to the components. The measured noise performance and dynamic range of the laboratory prototype meet the LISA requirements.

Thorpe, James Ira↗

Preliminary results of ultraviolet photometry of shell stars

Photometry of 40 B stars acquired by the OAO-2 has been examined for systematic differences between the 25 standard stars and 15 program objects. The latter include shell and Be stars and a few objects with at least a modest infrared excess. Although individual deviations did occur, no definite distinction between the program and comparison stars was found. A possible, but very weak, tendency for the program objects to lie somewhat below the standards in color-color plots is discussed, especially with reference to errors of misclassification and variability of the ultraviolet reddening law.

Bottemiller, R. L.↗

Geologic exploration: The contribution of LANDSAT-4 thematic mapper data

The major advantages of the TM data over that of MSS systems are increased spatial resolution and a greater number of narrow, strategically placed spectral bands. The 30 meter pixel size permits finer definition of ground features and improves reliability of the photointerpretation of geologic structure. The value of the spatial data increases relative to the value of the spectral data as soil and vegetation cover increase. In arid areas with good exposure, it is possible with careful digital processing and some inventive color compositing to produce enough spectral differentiation of rock types and thereby produce facsimiles of standard geologic maps with a minimum of field work or reference to existing maps. Hue-saturation value images are compared with geological maps of Death Valley, California, the Big Horn/Wind River Basin of Wyoming, the area around Cement, Oklahoma, and Detroit. False color composites of the Ontario region are also examined.

Everett, J. R.↗

An assembly to provide a time reference for the JPL Network Operations Control Center, Real-Time

A device is described which provides the value of date coordinated universal time (date UTC) to the JPL Network Operations Control Center, Real Time (NOCC-RT) facility. The NOCC-RT is the real time portion of the NOCC upgrade task. The time scale is generated in the NOCC-RT clock processor; however, there is a continuous reference to UTC, as realized by the National Institute of Standards and Technology and transmitted by Earth orbiting satellites. An important functional design requirement is the 99.9 pct. availability.

Clements, P. A.↗

Standard atmosphere - tables and data

Detailed tables of pressures and densities are given for altitudes up to 20,000 meters and to 65,000 feet. In addition to the tables the various data pertaining to the standard atmosphere have been compiled in convenient form for ready reference. This report is an extension of NACA-TR-147.

Diehl, Walter S↗

The First SIMBIOS Radiometric Intercomparison (SIMRIC-1), April-September 2001

This report describes the first SIMBIOS (Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies) Radiometric Intercomparison (SIMRIC-1). The purpose of the SIMRIC-1 is to ensure a common radiometric scale of the calibration facilities that are engaged in calibrating in situ radiometers used for ocean color related research and to document the calibration procedures and protocols. SIMBIOS staff visited the seven participating laboratories for at least two days each. The SeaWiFS Transfer Radiometer SXR-II measured the calibration radiances produced in the laboratories. The measured radiances were compared with the radiances expected by the laboratories. Typically, the measured radiances were higher than the expected radiances by 0 to 2%. This level of agreement is satisfactory. Several issues were identified, where the calibration protocols need to be improved, especially the reflectance calibration of the reference plaques and the distance correction when using the irradiance standards at distances greater than the 50 cm. The responsivity of the SXR-II changed between 0.3% (channel 6) and 1.6% (channel 2) from December 2000 to December 2001. Monitoring the SXR-II with a portable light source showed a linear drift of the calibration, except for channel 1, where a 2% drop occurred in summer.

Meister, Gerhard↗

Investigation of electrolyte measurement in diluted whole blood using spectroscopic and chemometric methods

The feasibility of using near-infrared (NIR) spectroscopy in combination with partial least-squares (PLS) regression was explored to measure electrolyte concentration in whole blood samples. Spectra were collected from diluted blood samples containing randomized, clinically relevant concentrations of Na+, K+, and Ca2+. Sodium was also studied in lysed blood. Reference measurements were made from the same samples using a standard clinical chemistry instrument. Partial least squares (PLS) was used to develop calibration models for each ion with acceptable results (Na+, R2 = 0.86, CVSEP = 9.5 mmol/L; K+, R2 = 0.54, CVSEP = 1.4 mmol/L; Ca2+, R2 = 0.56, CVSEP = 0.18 mmol/L). Slightly improved results were obtained using a narrower wavelength region (470-925 nm) where hemoglobin, but not water, absorbed indicating that ionic interaction with hemoglobin is as effective as water in causing measurable spectral variation. Good models were also achieved for sodium in lysed blood, illustrating that cell swelling, which is correlated with sodium concentration, is not required for calibration model development.

Non-NASA Center↗

Increased gait unsteadiness in community-dwelling elderly fallers

OBJECTIVE: To test the hypothesis that quantitative measures of gait unsteadiness are increased in community-dwelling elderly fallers. STUDY DESIGN: Retrospective, case-control study. SETTING: General community. PARTICIPANTS: Thirty-five community-dwelling elderly subjects older than 70 years of age who were capable of ambulating independently for 6 minutes were categorized as fallers (age, 82.2 +/- 4.9 yrs [mean +/- SD]; n = 18) and nonfallers (age, 76.5 +/- 4.0 yrs; n = 17) based on history; 22 young (age, 24.6 +/- 1.9 yrs), healthy subjects also participated as a second reference group. MAIN OUTCOME MEASURES: Stride-to-stride variability (standard deviation and coefficient of variation) of stride time, stance time, swing time, and percent stance time measured during a 6-minute walk. RESULTS: All measures of gait variability were significantly greater in the elderly fallers compared with both the elderly nonfallers and the young subjects (p < .0002). In contrast, walking speed of the elderly fallers was similar to that of the nonfallers. There were little or no differences in the variability measures of the elderly nonfallers compared with the young subjects. CONCLUSIONS: Stride-to-stride temporal variations of gait are relatively unchanged in community-dwelling elderly nonfallers, but are significantly increased in elderly fallers. Quantitative measurement of gait unsteadiness may be useful in assessing fall risk in the elderly.

NASA Discipline Cardiopulmonary↗

Synthesis of Submillimeter Radiation for Spectroscopy

The frequency-multiplier submillimeter spectrometer (FMSS) is a laboratory apparatus for far-infrared molecular spectroscopy, embodying several advances over prior such apparatuses. The most innovative part of the FMSS is a source of monochromatic submillimeter- wavelength radiation that can be tuned over a wide frequency range, as needed for trace gas analyses and molecular- structure studies for which such apparatuses are typically used. The radiation source features a modular design and is built mostly from commercially available components. It includes a computer-controlled radio-frequency synthesizer, amplifiers, and frequency multipliers of a type heretofore used in local oscillators for heterodyne far-infrared receivers. In conjunction with the rest of the apparatus, this source makes it possible to perform measurements over large portions of the submillimeter-wavelength spectrum with resolution, accuracy, and sensitivity greater than those achievable in Fourier-transform infrared spectroscopy. In comparison with prior laboratory submillimeter- wavelength radiation sources, this source is much lighter in weight, less cumbersome, less power-hungry, and capable of sustained operation with less intervention by laboratory personnel. Also, unlike some prior submillimeter-wavelength sources, this source does not require a high-voltage power source. As shown in more detail in the figure, the radiation source includes a sweep frequency synthesizer connected to an external waveform generator, the output of which is used as a reference signal. The synthesizer is computer-controlled through a standard general-purpose interface bus (GPIB) and is operated in phase-locked continuous- wave mode for all measurements. The synthesizer output ranges in frequency from 11 to 18 GHz. For suppression of frequency spurs and harmonics, the output of the frequency synthesizer is fed through a tunable yttrium iron garnet (YIG) filter, which is swept in frequency simultaneously with the frequency synthesizer.

Maiwald, Frank↗

Aero-Heating of Shallow Cavities in Hypersonic Freestream Flow

The purpose of these experiments and analysis was to augment the heating database and tools used for assessment of impact-induced shallow-cavity damage to the thermal protection system of the Space Shuttle Orbiter. The effect of length and depth on the local heating disturbance of rectangular cavities tested at hypersonic freestream conditions has been globally assessed using the two-color phosphor thermography method. These rapid-response experiments were conducted in the Langley 31-Inch Mach 10 Tunnel and were initiated immediately prior to the launch of STS-114, the initial flight in the Space Shuttle Return-To-Flight Program, and continued during the first week of the mission. Previously-designed and numerically-characterized blunted-nose baseline flat plates were used as the test surfaces. Three-dimensional computational predictions of the entire model geometry were used as a check on the design process and the two-dimensional flow assumptions used for the data analysis. The experimental boundary layer state conditions were inferred using the measured heating distributions on a no-cavity test article. Two test plates were developed, each containing 4 equally-spaced spanwise-distributed cavities. The first test plate contained cavities with a constant length-to-depth ratio of 8 with design point depth-to-boundary-layer-thickness ratios of 0.1, 0.2, 0.35, and 0.5. The second test plate contained cavities with a constant design point depth-to-boundary-layer-thickness ratio of 0.35 with length-to-depth ratios of 8, 12, 16, and 20. Cavity design parameters and the test condition matrix were established using the computational predictions. Preliminary results indicate that the floor-averaged Bump Factor (local heating rate nondimensionalized by upstream reference) at the tested conditions is approximately 0.3 with a standard deviation of 0.04 for laminar-in/laminar-out conditions when the cavity length-to-boundary-layer thickness is between 2.5 and 10 and for cavities in the depth-to-boundary-layer-thickness range of 0.3 to 0.8. Over this same range of conditions and parameters, preliminary results also indicate that the maximum Bump Factor on the cavity centerline falls between 2.0 and 2.75, as long as the cavity-exit conditions remain laminar. Cavities with length-to-boundary-layer-thickness ratio less than 2.5 can not be easily classified with this approach and require further analysis.

Everhart, Joel L.↗

Sensitivity of C-Band Polarimetric Radar-Based Drop Size Distribution Measurements to Maximum Diameter Assumptions

The estimation of rain drop size distribution (DSD) parameters from polarimetric radar observations is accomplished by first establishing a relationship between differential reflectivity (Z(sub dr)) and the central tendency of the rain DSD such as the median volume diameter (D0). Since Z(sub dr) does not provide a direct measurement of DSD central tendency, the relationship is typically derived empirically from rain drop and radar scattering models (e.g., D0 = F[Z (sub dr)] ). Past studies have explored the general sensitivity of these models to temperature, radar wavelength, the drop shape vs. size relation, and DSD variability. Much progress has been made in recent years in measuring the drop shape and DSD variability using surface-based disdrometers, such as the 2D Video disdrometer (2DVD), and documenting their impact on polarimetric radar techniques. In addition to measuring drop shape, another advantage of the 2DVD over earlier impact type disdrometers is its ability to resolve drop diameters in excess of 5 mm. Despite this improvement, the sampling limitations of a disdrometer, including the 2DVD, make it very difficult to adequately measure the maximum drop diameter (D(sub max)) present in a typical radar resolution volume. As a result, D(sub max) must still be assumed in the drop and radar models from which D0 = F[Z(sub dr)] is derived. Since scattering resonance at C-band wavelengths begins to occur in drop diameters larger than about 5 mm, modeled C-band radar parameters, particularly Z(sub dr), can be sensitive to D(sub max) assumptions. In past C-band radar studies, a variety of D(sub max) assumptions have been made, including the actual disdrometer estimate of D(sub max) during a typical sampling period (e.g., 1-3 minutes), D(sub max) = C (where C is constant at values from 5 to 8 mm), and D(sub max) = M*D0 (where the constant multiple, M, is fixed at values ranging from 2.5 to 3.5). The overall objective of this NASA Global Precipitation Measurement Mission (GPM/PMM Science Team)-funded study is to document the sensitivity of DSD measurements, including estimates of D0, from C-band Z(sub dr) and reflectivity to this range of D(sub max) assumptions. For this study, GPM Ground Validation 2DVD's were operated under the scanning domain of the UAHuntsville ARMOR C-band dual-polarimetric radar. Approximately 7500 minutes of DSD data were collected and processed to create gamma size distribution parameters using a truncated method of moments approach. After creating the gamma parameter datasets the DSD's were then used as input to a T-matrix model for computation of polarimetric radar moments at C-band. All necessary model parameterizations, such as temperature, drop shape, and drop fall mode, were fixed at typically accepted values while the D(sub max) assumption was allowed to vary in sensitivity tests. By hypothesizing a DSD model with D(sub max) (fit) from which the empirical fit to D0 = F[Z(sub dr)] was derived via non-linear least squares regression and a separate reference DSD model with D(sub max) (truth), bias and standard error in D0 retrievals were estimated in the presence of Z(sub dr) measurement error and hypothesized mismatch in D(sub max) assumptions. Although the normalized standard error for D0 = F[Z(sub dr)r] can increase slightly (as much as from 11% to 16% for all 7500 DSDs) when the D(sub max) (fit) does not match D(sub max) (truth), the primary impact of uncertainty in D(sub max) is a potential increase in normalized bias error in D0 (from 0% to as much as 10% over all 7500 DSDs, depending on the extent of the mismatch between D(sub max) (fit) and D(sub max) (truth)). For DSDs characterized by large Z(sub dr) (Z(sub dr) > 1.5 to 2.0 dB), the normalized bias error for D0 estimation at C-band is sometimes unacceptably large (> 10%), again depending on the extent of the hypothesized D(sub max) mismatch. Modeled errors in D0 retrievals from Z(sub dr) at C-band are demonstrated in detail and comparedo similar modeled retrieval errors at S-band and X-band where the sensitivity to D(sub max) is expected to be less. The impact of D(sub max) assumptions to the retrieval of other DSD parameters such as Nw, the liquid water content normalized intercept parameter, are also explored. Likely implications for DSD retrievals using C-band polarimetric radar for GPM are assessed by considering current community knowledge regarding D(sub max) and quantifying the statistical distribution of Z(sub dr) from ARMOR over a large variety of meteorological conditions. Based on these results and the prevalence of C-band polarimetric radars worldwide, a call for more emphasis on constraining our observational estimate of D(sub max) within a typical radar resolution volume is made

Carey, Lawrence D.↗

Lambert’s Problem – A Geometric Approach

A fundamental problem in spacecraft mission design is to find a free flight path from one place to another in a chosen travel time. Lambert studied this problem for free flight in an inverse square central force field, and Lagrange produced a solution in 1778. Although this is an old problem, a new approach may be of some value. There are two steps to the new solution. First, find every ellipse with focus at the origin that intersects two circles both centered at the origin. Then select only those ellipses that have a specified angle between the intersection points of the ellipse with the inner and outer circles. Second, find the travel times between intersections for each ellipse. These are all the possible travel times from which one may choose. Standard solutions to Lambert’s problem can be found in references [1-4].

Easton, Robert↗

Formal Analysis of the Compact Position Reporting Algorithm

This presentation documents the formal analysis of the compact position reporting (CPR) algorithm. CPR is a fundamental part of Automatic Dependent Surveillance - Broadcast (ADS-B), which is a global protocol for aircraft communication. The formal analysis found and corrected issues with the algorithm, proposed simplifications, and created a formally verified reference implementation, all of which are incorporated in the governing standards document.

Formal Methods↗

Comparison Between Ozone Column Depths and Methane Lifetimes Computed By One- and Three-Dimensional Models at Different Atmospheric O(2) Levels

The calculation of ozone column depth as a function of atmospheric O2concentration has been performed multiple times over the past 40 years using one-dimensional (1-D) photochemical models. Several of these calculations [1–3] have been done by the Kasting group. We refer to the current version of that model as the‘standard’1-D model (see §2). Recently, Cooke et al., henceforth C22 ,performed a similar calculation using a three-dimensional (3-D) coupled chemistry-climate model (WACCM6). They found substantially lower ozone column depths at lower pO2levels. For example, at0.01 times the present atmospheric level (PAL) of O(2), Segura et al. calculated 124 Dobson units(DU), whereas C22 calculated a mean column depth of just 66 DU—almost a factor of two lower. This comparison is shown in figure 1. C22 argued, correctly, that 3-D models should be able to do a better job on this problem than 1-D models because ozone column depths are affected by atmospheric transport, e.g. the Brewer–Dobson circulation in the stratosphere that blows ozone from the tropics towards the poles, as well as vertical transport that carries ozone downward from the stratosphere to the troposphere. Meridional transport is absent in 1-D models, and vertical transport is fixed, so model geometry almost certainly contributes to the observed discrepancies in ozone column depth. The 3-D model also has a variable tropopause height (higher at the equator, lower towards the poles), which is difficult to simulate in one dimension.

Atmospheric chemistry↗

Conversion of Environment Files from ORDEM 3 & MEM 3 to STENVI

To perform Micrometeoroid and Orbital Debris (MMOD) analyses, NASA describes the orbital debris particle environment using the ORDEM 3 tool and the micrometeoroid environment using the MEM 3 tool. Both output files that detail the flux of particles as a function of several parameters. European MMOD analyses use different tools to perform similar functions, including the Meteoroid And Space debris Terrestrial Environment Reference (MASTER) environment model, which outputs flux data in the Standard Environment Interface (STENVI) format. The NASA Johnson Space Center Hypervelocity Impact Technology Group was asked to create a converter to translate flux data from the output file formats used by ORDEM 3.x and MEM 3 into the STENVI file format. Validation was performed to ensure that the converter was reproducing the input data correctly. The Bumper 3 MMOD risk assessment tool has a capability for reading ORDEM 3.x, MEM 3, and STENVI environment file formats and was used to compare MMOD risk results generated using the converter’s output STENVI files to the risk results generated using the input ORDEM 3.x and MEM 3 igloo files. Specific point comparisons validated that the converter translated the environment data correctly, producing the intended output. However, realistic risk assessments showed that the bin methodology employed by Bumper for determining particle flux as a function of particle size when reading files in STENVI format produces much higher MMOD risk than the point-interpolation methodology used in Bumper risk assessments using ORDEM and MEM. Modifications to how Bumper 3 reads STENVI files during analyses are considered to improve Bumper’s ability to perform useful analyses with environment files in this format.

STENVI↗

Conversion of ORDEM 3.X & MEM 3 Into STENVI File Format

To perform Micrometeoroid and Orbital Debris (MMOD) analyses, NASA describes the orbital debris particle environment using the ORDEM 3 tool and the micrometeoroid environment using the MEM 3 tool. Both output files that detail the flux of particles as a function of several parameters. European MMOD analyses use different tools to perform similar functions, including the Meteoroid And Space debris Terrestrial Environment Reference (MASTER) environment model, which outputs flux data in the Standard Environment Interface (STENVI) format. The NASA Johnson Space Center Hypervelocity Impact Technology Group was asked to create a converter to translate flux data from the output file formats used by ORDEM 3.x and MEM 3 into the STENVI file format. Validation was performed to ensure that the converter was reproducing the input data correctly. The Bumper 3 MMOD risk assessment tool has a capability for reading ORDEM 3.x, MEM 3, and STENVI environment file formats and was used to compare MMOD risk results generated using the converter’s output STENVI files to the risk results generated using the input ORDEM 3.x and MEM 3 igloo files. Specific point comparisons validated that the converter translated the environment data correctly, producing the intended output. However, realistic risk assessments showed that the bin methodology employed by Bumper for determining particle flux as a function of particle size when reading files in STENVI format produces much higher MMOD risk than the point-interpolation methodology used in Bumper risk assessments using ORDEM and MEM. Modifications to how Bumper 3 reads STENVI files during analyses are considered to improve Bumper’s ability to perform useful analyses with environment files in this format.

STENVI↗