Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference state”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Gap-filled methane and carbon dioxide fluxes across two ecosystem states at the US-OWC AmeriFlux site (2015−2016, 2020−2022)

This dataset contains gap-filled measurements of methane flux (FCH4), net ecosystem CO2 exchange (NEE) partitioned into gross primary productivity (GPP) and ecosystem respiration (RE), as well as latent heat flux (LE) from a Great Lakes coastal freshwater wetland at the US-OWC AmeriFlux site. The dataset covers the peak growing seasons (June−September) of 2015−2016, dominated by Typha spp., and 2020−2022, characterized by floating-leaved species (lotus and water lily). These data were generated to investigate how rising water levels and vegetation shifts influence CH4 and CO2 fluxes across two distinct ecosystem states in this wetland. The dataset, provided in CSV format, includes half-hourly gap-filled flux data from June to September for 2015, 2016, 2020, 2021, and 2022. The gap-filled data refers to measurements where missing values due to instrument issues or quality control were filled using artificial neural networks (ANNs).

54 ENVIRONMENTAL SCIENCES↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

Decoupling electrode kinetics to elucidate reaction mechanisms in alkaline water electrolysis

Alkaline water electrolysis (AWE) presents key advantages, including reduced material costs, enhanced operational stability, and compatibility with non-precious metal catalysts, positioning it as a scalable route for hydrogen production. In this study, we introduce a minimally invasive single-cell configuration incorporating a reference electrode via diaphragm extension to form an internal ion channel. This setup, combined with an interfaced potentiostat and auxiliary electrometer, enables real-time, independent monitoring of anode and cathode behavior, offering high-resolution electrochemical diagnostics. While it is well established that the hydrogen evolution reaction (HER) exhibits sluggish kinetics in alkaline media, our study reveals that this limitation persists even in practical AWE systems where nickel-based substrates are used as electrodes. This observation is supported by both experimental data and voltage breakdown modeling. Arrhenius-type analysis reveals that localized electric fields induced by catalysts shift the reaction kinetics from classical Butler–Volmer behavior toward a Marcus-like regime, where interfacial molecular dynamics and bimolecular charge transfer dominate. We propose a semi-empirical model and a surficial reaction mechanism to describe these dynamics. This work underscores the critical need for cathode innovation and provides a rational framework for designing advanced catalysts and electrode architectures to optimize AWE performance.

08 HYDROGEN↗

Beyond Single-Reference Fixed-Node Approximation in Ab Initio Diffusion Monte Carlo Using Antisymmetrized Geminal Power Applied to Systems with Hundreds of Electrons

Diffusion Monte Carlo (DMC) is an exact technique to project out the ground state (GS) of a Hamiltonian. Since the GS is always bosonic, in Fermionic systems, the projection needs to be carried out while imposing antisymmetric constraints, which is a nondeterministic polynomial hard problem. In practice, therefore, the application of DMC on electronic structure problems is made by employing the fixed-node (FN) approximation, consisting of performing DMC with the constraint of having a fixed, predefined nodal surface. How do we get the nodal surface? The typical approach, applied in systems having up to hundreds or even thousands of electrons, is to obtain the nodal surface from a preliminary mean-field approach (typically, a density functional theory calculation) used to obtain a single Slater determinant. This is known as single reference. In this paper, we propose a new approach, applicable to systems as large as the C 60 fullerene, which improves the nodes by going beyond the single reference. In practice, we employ an implicitly multireference ansatz (antisymmetrized geminal power wave function constraint with molecular orbitals), initialized on the preliminary mean-field approach, which is relaxed by optimizing a few parameters of the wave function determining the nodal surface by minimizing the FN-DMC energy. We highlight the improvements of the proposed approach over the standard single-reference method on several examples and, where feasible, the computational gain over the standard multireference ansatz, which makes the methods applicable to large systems. We also show that physical properties relying on relative energies, such as binding energies, are affordable and reliable within the proposed scheme.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Next-generation large-scale binary protein interaction network for Drosophila melanogaster

Generating reference maps of interactome networks illuminates genetic studies by providing a protein-centric approach to finding new components of existing pathways, complexes, and processes. We apply state-of-the-art methods to identify binary protein-protein interactions (PPIs) for Drosophila melanogaster. Four all-by-all yeast two-hybrid (Y2H) screens of > 10,000 Drosophila proteins result in the ‘FlyBi’ dataset of 8723 PPIs among 2939 proteins. Testing subsets of data from FlyBi and previous PPI studies using an orthogonal assay allows for normalization of data quality; subsequent integration of FlyBi and previous data results in an expanded binary Drosophila reference interaction network, DroRI, comprising 17,232 interactions among 6511 proteins. We use FlyBi data to generate an autophagy network, then validate in vivo using autophagy-related assays. The deformed wings (dwg) gene encodes a protein that is both a regulator and a target of autophagy. Altogether, these resources provide a foundation for building new hypotheses regarding protein networks and function.

59 BASIC BIOLOGICAL SCIENCES↗

Wind Turbine Water Setbacks: Ordinances (2022) and Extrapolated Trends, 115 Hub Height 170 Rotor Diameter

This dataset represents wind energy setback requirements from water based on existing county ordinances as of April 2022. A setback requirement is a minimum distance from water that an energy project may be developed, and these varied widely across the counties in which they existed. Two versions are provided: one reflecting only the county ordinances and another incorporating extrapolated trends. In the extrapolated version, a median setback equivalent to 1.1 times the turbine tip-height was applied in counties that lacked specific water setback regulations. A TIF data file and a PNG map of the data are provided for both versions, showing areas where wind energy is prohibited or permitted across the contiguous United States. The turbine parameters used were a hub-height of 115 meters and a rotor diameter of 170 meters, as obtained from the Annual Technology Baseline (ATB) 2022. For further details and citation, please refer to the publication linked below: Lopez, Anthony, Pavlo Pinchuk, Michael Gleason, Wesley Cole, Trieu Mai, Travis Williams, Owen Roberts, Marie Rivers, Mike Bannister, Sophie-Min Thomson, Gabe Zuckerman, and Brian Sergi. 2024. Solar Photovoltaics and Land-Based Wind Technical Potential and Supply Curves for the Contiguous United States: 2023 Edition. Golden, CO: National Renewable Energy Laboratory. NREL/TP-6A20-87843.

Array↗

Wind Turbine Transmission Setbacks: Ordinances (2022) and Extrapolated Trends, 115 Hub Height 170 Rotor Diameter

This dataset represents wind energy setback requirements from transmission based on existing county ordinances as of April 2022. A setback requirement is a minimum distance from transmission infrastructure that an energy project may be developed, and these varied widely across the counties in which they existed. Two versions are provided: one reflecting only the county ordinances and another incorporating extrapolated trends. In the extrapolated version, a median setback equivalent to 1.1 times the turbine tip-height was applied in counties that lacked specific transmission setback regulations. A TIF data file and a PNG map of the data are provided for both versions, showing areas where wind energy is prohibited or permitted across the contiguous United States. The turbine parameters used were a hub-height of 115 meters and a rotor diameter of 170 meters, as obtained from the Annual Technology Baseline (ATB) 2022. For further details and citation, please refer to the publication linked below: Lopez, Anthony, Pavlo Pinchuk, Michael Gleason, Wesley Cole, Trieu Mai, Travis Williams, Owen Roberts, Marie Rivers, Mike Bannister, Sophie-Min Thomson, Gabe Zuckerman, and Brian Sergi. 2024. Solar Photovoltaics and Land-Based Wind Technical Potential and Supply Curves for the Contiguous United States: 2023 Edition. Golden, CO: National Renewable Energy Laboratory. NREL/TP-6A20-87843.

Array↗

Wind Turbine Structure Setbacks: Ordinances (2022) and Extrapolated Trends, 115 Hub Height 170 Rotor Diameter

This dataset represents wind energy setback requirements from structures based on existing county ordinances as of April 2022. A setback requirement is a minimum distance from a structure that an energy project may be developed, and these varied widely across the counties in which they existed. Two versions are provided: one reflecting only the county ordinances and another incorporating extrapolated trends. In the extrapolated version, a median setback equivalent to 2 times the turbine tip-height was applied in counties that lacked specific structure setback regulations. A TIF data file and a PNG map of the data are provided for both versions, showing areas where wind energy is prohibited or permitted across the contiguous United States. The turbine parameters used were a hub-height of 115 meters and a rotor diameter of 170 meters, as obtained from the Annual Technology Baseline (ATB) 2022. For further details and citation, please refer to the publication linked below: Lopez, Anthony, Pavlo Pinchuk, Michael Gleason, Wesley Cole, Trieu Mai, Travis Williams, Owen Roberts, Marie Rivers, Mike Bannister, Sophie-Min Thomson, Gabe Zuckerman, and Brian Sergi. 2024. Solar Photovoltaics and Land-Based Wind Technical Potential and Supply Curves for the Contiguous United States: 2023 Edition. Golden, CO: National Renewable Energy Laboratory. NREL/TP-6A20-87843.

Array↗

Wind Turbine Road Setbacks: Ordinances (2022) and Extrapolated Trends, 115 Hub Height 170 Rotor Diameter

This dataset represents wind energy setback requirements from roads based on existing county ordinances as of April 2022. A setback requirement is a minimum distance from a road that an energy project may be developed, and these varied widely across the counties in which they existed. Two versions are provided: one reflecting only the county ordinances and another incorporating extrapolated trends. In the extrapolated version, a median setback equivalent to 1.1 times the turbine tip-height was applied in counties that lacked specific railroad setback regulations. A TIF data file and a PNG map of the data are provided for both versions, showing areas where wind energy is prohibited or permitted across the contiguous United States. The turbine parameters used were a hub-height of 115 meters and a rotor diameter of 170 meters, as obtained from the Annual Technology Baseline (ATB) 2022. For further details and citation, please refer to the publication linked below: Lopez, Anthony, Pavlo Pinchuk, Michael Gleason, Wesley Cole, Trieu Mai, Travis Williams, Owen Roberts, Marie Rivers, Mike Bannister, Sophie-Min Thomson, Gabe Zuckerman, and Brian Sergi. 2024. Solar Photovoltaics and Land-Based Wind Technical Potential and Supply Curves for the Contiguous United States: 2023 Edition. Golden, CO: National Renewable Energy Laboratory. NREL/TP-6A20-87843.

Array↗

Wind Turbine Railroad Setbacks: Ordinances (2022) and Extrapolated Trends, 115 Hub Height 170 Rotor Diameter

This dataset represents wind energy setback requirements from railroad based on existing county ordinances as of April 2022. A setback requirement is a minimum distance from a railroad that an energy project may be developed, and these varied widely across the counties in which they existed. Two versions are provided: one reflecting only the county ordinances and another incorporating extrapolated trends. In the extrapolated version, a median setback equivalent to 1.1 times the turbine tip-height was applied in counties that lacked specific railroad setback regulations. A TIF data file and a PNG map of the data are provided for both versions, showing areas where wind energy is prohibited or permitted across the contiguous United States. The turbine parameters used were a hub-height of 115 meters and a rotor diameter of 170 meters, as obtained from the Annual Technology Baseline (ATB) 2022. For further details and citation, please refer to the publication linked below: Lopez, Anthony, Pavlo Pinchuk, Michael Gleason, Wesley Cole, Trieu Mai, Travis Williams, Owen Roberts, Marie Rivers, Mike Bannister, Sophie-Min Thomson, Gabe Zuckerman, and Brian Sergi. 2024. Solar Photovoltaics and Land-Based Wind Technical Potential and Supply Curves for the Contiguous United States: 2023 Edition. Golden, CO: National Renewable Energy Laboratory. NREL/TP-6A20-87843.

Array↗

Wind Turbine Oil and Gas Pipeline Setbacks: Ordinances (2022) and Extrapolated Trends, 115 Hub Height 170 Rotor Diameter

This dataset represents wind energy setback requirements from oil and gas pipelines. A setback requirement is a minimum distance from a pipeline that an energy project may be developed. As of April 2022, no ordinances were discovered for any counties. Such ordinances are likely to arise as regulations continue to expand. Therefore, this dataset applies a median setback equivalent to 1.1 times the turbine tip-height, sourced from trends in other infrastructure. A TIF data file and a PNG map of the data are provided, showing areas where wind energy is prohibited or permitted across the contiguous United States. The turbine parameters used were a hub-height of 115 meters and a rotor diameter of 170 meters, as obtained from the Annual Technology Baseline (ATB) 2022. For further details and citation, please refer to the publication linked below: Lopez, Anthony, Pavlo Pinchuk, Michael Gleason, Wesley Cole, Trieu Mai, Travis Williams, Owen Roberts, Marie Rivers, Mike Bannister, Sophie-Min Thomson, Gabe Zuckerman, and Brian Sergi. 2024. Solar Photovoltaics and Land-Based Wind Technical Potential and Supply Curves for the Contiguous United States: 2023 Edition. Golden, CO: National Renewable Energy Laboratory. NREL/TP-6A20-87843.

Array↗

Slip Tendency Analysis of Fracture Networks to Determine Suitability of Candidate Testbeds for the EGS Collab Hydroshear Experiment

Experiment 2 of the EGS Collab project is aimed at testing stimulation by hydro-shearing of existing natural fractures, versus Experiment 1, which is focused on hydraulic fracturing a rock mass to enhance permeability. The main criterion for the testbed selection in Experiment 2 is the presence of an interconnected network of fractures, at least 10 meters in extent, and with orientations such that shear slip can be induced at injection pressures less than the minimum horizontal stress (Shmin). The feasibility analysis for this experiment requires a well-constrained stress state along with well-characterized fracture networks. The fracture systems at two candidate locations in the Sanford Underground Research Facility (SURF), the 4850 Level (number refers to depth below ground surface in feet) and the 4100 Level, have been characterized to different extents. The 4850 Level has a well-characterized Discrete Fracture Network (DFN) from borehole (drilled for an experimental test bed) and drift observations. In contrast, the 4100 level has a fracture network characterized only by observations from the drift wall, which provides little constraint on fracture extents. This paper will present assessments for the interpreted slip potential for the natural fractures at the two locations. Data uncertainties are addressed by performing a probabilistic analysis that takes into account the uncertainty in the stress state, uncertainty in the fracture properties, and preliminary borehole locations. There is strong evidence of shear stimulation of some natural fractures in Experiment 1 on the 4850 level. We use examples of natural fractures strongly linked to shear stimulation in Experiment 1 from multiple monitoring indicators to test the consistency of the stress model and guide the uncertainty interpretation. This analysis is intended to guide the site selection process for Experiment 2 by highlighting the fracture orientations that are likely to be shear-stimulated in a majority of modeled realizations.

40 EE - Geothermal Technologies Office (EE-4G)↗

Scanning transmission x-ray microscopy (STXM) of plutonium oxide

Scanning transmission x-ray microscopy was used to examine plutonium oxide particles formed by the corrosion of δ-phase plutonium alloy under high-humidity conditions. O K-edge spectra collected from eight distinct particles displayed significant spectral differences, revealing heterogeneity in oxidation states within a single sample batch. Here, this variation suggests complex chemical environments and formation histories, which are important considerations for nuclear forensic investigations. These findings highlight both the potential of synchrotron-based x-ray microscopy for nondestructive, high-resolution analysis of nuclear materials and the need for expanded reference datasets to improve the interpretation and forensic utility of such measurements.

organic↗

An analytic and complete equation of state for condensed phase materials

Analytic equations of state (EOS) are intended to reproduce theoretical and experimental data in a single phase portion of the thermodynamic space. We devise a complete and thermodynamically consistent model with four distinct features: (1) a reference isotherm that remains thermodynamically stable, (2) a flexible specific heat model based on a fourth-order rational polynomial, (3) a Grüneisen parameter that depends on specific volume and temperature, and (4) pressure and internal energy functions that can be inverted analytically in temperature. The model aims to improve the accuracy of existing equations of state while remaining computationally efficient. To demonstrate its features, we include calibrations for single-crystal pentaerythritol tetranitrate (PETN), liquid nitromethane (NM), and hexagonal close-packed beryllium (Be) metal. The parameter optimization uses the specific heat capacity, Grüneisen parameter, and static compression curves obtained from density functional theory for the crystalline solids and molecular dynamics simulations for liquid NM. We also present a velocity autocorrelation function that yields accurate phonon densities of states for the EOS calibration from the molecular dynamics trajectories. Each of the three calibrations is constrained to enforce the ambient state from experimental measurements and validated against experimental Hugoniot data from multiple sources. We also include one-dimensional hydrodynamic simulations of the isentropic compression experiments for beryllium conducted at the Z facility.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

Assessment of Low-Level Pu Isotope Ratio Measurements Using Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS/MS) Equipped with a Pre-Mass Filter

We present an initial investigation into the performance of a multicollector inductively coupled plasmamass spectrometer equipped with a pre-mass filter (Neoma MC-ICP-MS/MS) for making plutonium (Pu) isotope ratio measurements on solutions containing low level (i.e., pg mL –1 ) Pu concentrations. This assessment was achieved by comparison of the 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu ratios attained over a one month period on the MC-ICP-MS/MS with the long-term (∼1 year) performance observed on the predecessor MC-ICP-MS (Neptune Plus) instrument each equipped with an equipped with an APEXΩ desolvating nebulizer for repeated measurements of certified reference materials from New Brunswick Program Office (NBL PO) CRM 136a and CRM 137. The MC-ICP-MS/MS performance of repeated measurement of CRM 136a (n = 20) resulted in mean values of 240 Pu/ 239 Pu = 0.1448 ± 0.0006, 241 Pu/ 239 Pu = 0.00371 ± 0.00006, and 242 Pu/ 239 Pu = 0.00682 ± 0.00006 (k = 2). The CRM 137 (n = 20), analyzed during the same analytical sessions, produced mean values for 240 Pu/ 239 Pu = 0.2414 ± 0.0006, 241 Pu/ 239 Pu = 0.00464 ± 0.00007, and 242 Pu/ 239 Pu = 0.0157 ± 0.0001 (k = 2). These results closely align with the certificate values for CRM 136a and CRM 137 and are within the k = 2 envelopes defined by the long-term performance of the traditional MC-ICP-MS approach (Neptune Plus). Examination of the performance of the various Pu isotope ratios as a function of total Pu content revealed accurate results (<3% relative difference, or RD) above ∼50 fg total Pu. The results presented here demonstrate the capability of the MC-ICP-MS/MS making accurate and precise low level Pu isotopic measurements. While the intent of this work was not to investigate the functionality of the collision cell, the pre-mass filter was employed. Future studies are warranted to investigate the entire capability of the MC-ICP-MS/MS collision cell and pre-cell mass filter optimization for performing low level Pu isotope measurements, even in mixed matrix samples.

CRM↗

DOE SCGSR Final Report - Project Accomplishments and Additional Materials

The major accomplishments of my project were successfully developing and testing the laser interferometry diagnostic on the Plasma Liner Experiment (PLX) at Los Alamos National Laboratory (LANL). This diagnostic helped advance my research by providing a simpler way to obtain electron density measurements of magnetized plasmas compared to other electron density diagnostics such as triple Langmuir probes. The laser used was a 561 nm continuous wave (CW) diode-pumped solid state (DPSS) laser. The PLX laser interferometry diagnostic consists of two parts. These include the launching and receiving sides of the laser diagnostic. The launching side consists of the main laser beam from the DPSS laser being split into five chords(probe beams) and a reference beam which are then directed with fiber optic couplers into fiber optic cables which transmit the probe beamsto the PLX vacuum chamber. The probe beams then pass through the plasma in the chamber and into the receiving side optics where they are again directed through fiber optic cables to be combined with the reference beam. The combined beams are transmitted via multi-mode fiber optic cables to photodiodes to convert the light signals into electrical signals. Before the electrical signals get digitized, they pass through bandpass and low pass filters to eliminate electromagnetic noise and unwanted frequencies. The electrical signals are then processed by IQ demodulators to determine phase angle difference between the probe and reference beams for each chord in order to calculate line-integrated electron density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hardware Specification and Reference Design for the Low-Cost, Interoperable, User-Centric, Supervisory Controller Kit for Small and Medium Size Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems to manage the various building systems they have. Many of these buildings are small (< 50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper control systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the RTU’s heating and cooling setpoints, schedules, setbacks, and optimal start times can result in 20 to 25 percent reduction in electricity consumption in small and medium commercial buildings (SMBs). In addition, improving the demand flexibility of these buildings will result in additional cost savings for the building owner. To address the needs of the SMBs, the Department of Energy’s Building Technologies Office jointly funded Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) to design, develop, test, and validate a low-cost, interoperable, user-centric, retrofit supervisory controller kit (SC-SMB) that can be used to continuously optimize energy consumption and deliver demand flexibility of SMBs, including all-electric buildings, and provide a means for maximizing decarbonization benefits. The team also includes industry partners Edo and Intellimation. Previously, the team drafted an SC-SMB system specification document (Goodman et al. 2023). This document describes a reference design of a low-cost supervisory control system for SMBs, including the various hardware components, software system, and an example implementation of the reference design. The final release of the reference design is planned for December 2025. Section 2.0 of the report documents the relevant building types that the SC-SMB system is suitable for. Section 3.0 documents the various hardware components, their function, cost, whether they are off-the-shelve, support standard communication, etc., and the software system. An example deployment in a 10,000-sf building with six rooftop units, a hot water heater, solar, and storage is described in Section 4.0. The planned next steps are described in Section 5.0, and references are listed in Section 6.0.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗