Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL PROCESSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Data analysis for valve leak detection of nuclear power plant safety critical components - 336

A nuclear plant consists of several safety-related components. These safety-related components are tested periodically in order to verify their functionality when they are called upon to perform. The data acquired during periodic testing provides information about possible degradation of the equipment or device under test. This research is focused on leak monitoring techniques to provide diagnostic information on the determination of valve aging and degradation. Several commercially available valve diagnostic-monitoring methods are evaluated, especially for the techniques based on measurements of acoustic emission, and accelerometer. The check valve is one of typical components being extensively used in safety systems of nuclear power plants. The failures of check valves have resulted in significant maintenance efforts, on occasion, have resulted in water hammer, over-pressurization of low-pressure systems, and damage to flow system components. In this paper, acoustic emission signals due to leak from check valves with artificial leakage and worn parts are investigated both analytically and experimentally. The results of advanced signal processing and de-noising techniques also have been identified. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Upgrading a high-throughput spectrometer for high-frequency (<400 kHz) measurements

The upgraded spectrometer used for charge exchange recombination spectroscopy on the Madison Symmetric Torus resolves emission fluctuations up to 400 kHz. The transimpedance amplifier’s cutoff frequency was increased based upon simulations comparing the change in the measured photon counts for time-dynamic signals. We modeled each signal-processing stage of the diagnostic and scanned the filtering frequency to quantify the uncertainty in the photon counting rate. This modeling showed that uncertainties can be calculated based on assuming each amplification stage is a Poisson process and by calibrating the photon counting rate with a DC light source to address additional variation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Switching and intrinsic position bistability of soliton beams in chiral nematic liquid crystals

We study theoretically and experimentally the propagation of light beams in chiral nematic liquid crystals. Despite the rather complex refractive index distribution of these crystals, their reorientational nonlinearity can compensate for diffraction, leading to robust solitonlike beams propagating along helical trajectories. We demonstrate that, due to a symmetry-breaking instability of the liquid crystal structure, these beams undergo abrupt switching and bistability, features that are of potential interest for applications to all-optical signal processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Trends in Nuclear Explosion Monitoring Research & Development - A Physics Perspective

This document entitled “Trends in Nuclear Explosion Monitoring Research and Development – A Physics Perspective” reviews the accessible literature, as it relates to nuclear explosion monitoring and the Comprehensive Nuclear-Test-Ban Treaty (CTBT, 1996), for four research areas: source physics (understanding signal generation), signal propagation (accounting for changes through physical media), sensors (recording the signals), and signal analysis (processing the signal). Over 40 trends are addressed, such as moving from 1D to 3D earth models, from pick-based seismic event processing to full waveform processing, and from separate treatment of mechanical waves in different media to combined analyses. Highlighted in the document for each trend are the value and benefit to the monitoring mission, key papers that advanced the science, and promising research and development for the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Room Temperature Lasing from Semiconducting Single-Walled Carbon Nanotubes

Miniaturized near-infrared semiconductor lasers that are able to generate coherent light with low energy consumption have widespread applications in fields such as optical interconnects, neuromorphic computing, and deep-tissue optogenetics. With optical transitions at near-infrared wavelengths, diameter-tunable electronic structures, and superlative optoelectronic properties, semiconducting single-walled carbon nanotubes (SWCNTs) are promising candidates for nanolaser applications. However, despite significant efforts in this direction and recent progress toward enhancing spontaneous emission from SWCNTs through Purcell effects, SWCNT-based excitonic lasers have not yet been demonstrated. Leveraging an optimized cavity-emitter integration scheme enabled by a self-assembly process, here we couple SWCNT emission to the whispering gallery modes supported by polymer microspheres, resulting in room temperature excitonic lasing with an average lasing threshold of 4.5 kW/cm 2 . The high photostability of SWCNTs allows stable lasing for prolonged duration with minimal degradation. Finally, this experimental realization of excitonic lasing from SWCNTs, combined with their versatile electronic and optical properties that can be further controlled by chemical modification, offers far-reaching opportunities for tunable near-infrared nanolasers that are applicable for optical signal processing, in vivo biosensing, and optoelectronic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WIDEBAND ULTRASONIC TIME OF FLIGHT DIFFRACTION COMBINING B-SCANS AND CROSS-SECTIONAL IMAGING

Time of Flight Diffraction and Imaging (ToFDI) is a new technique utilizing a sparse array of transducers and signal processing to improve B-Scan output and create a cross-sectional image of a sample. This paper describes preliminary work demonstrating the concept, including; Finite Element Modelling (FEM), basic processing, likely applications. The eventual aim is for fast and automated detection, identification, positioning and sizing for all defects in a sample with known basic characteristics, such as bulk and shear elastic moduli.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Computational Capacity of Mem-LRC Reservoirs

Reservoir computing has a emerged as a powerful tool in data-driven time series analysis. The possibility of utilizing hardware reservoirs as specialized co-processors has generated interest in the properties of electronic reservoirs, especially those based on memristors as the nonlinearity of these devices should translate to an improved nonlinear computational capacity of the reservoir. However, designing these reservoirs requires a detailed understanding of how memristive networks process information which has thus far been lacking. In this work, we derive an equation for general memristor-inductor-resistor-capacitor (MEM-LRC) reservoirs that includes all network and dynamical constraints explicitly. Utilizing this we undertake a study of the computational capacity of these reservoirs. We demonstrate that hardware reservoirs may be constructed with extensive memory capacity and that the presence of memristors enacts a tradeoff between memory capacity and nonlinear computational capacity. Here, using these principles, we design reservoirs to tackle problems in signal processing, paving the way for applying hardware reservoirs to high-dimensional spatiotemporal systems.

Circuits with memory↗

Design and fabrication of ring resonator spectral response through-drop wavelengths selective

In this paper, we discuss the basic characteristics of the SOI based micro-ring resonator, and understand the influence of the high refractive index difference and the small size on the spectral characteristics of the ring resonator. The novelty and importance of the spectral response selectivity of ring resonators is driven by the grating couple technique. This advantage is the periodic variation of the refractive index in the coupled grating, which will result in the coupling of the conduction wave modes. By means of measurement and simulation, observe the changes and trends of the spectrum in steady state and transient state, and finally analyze the performance of the ring resonator in the application of signal processing. It achieves polarization-independent grating couplers with high efficiency, wide bandwidth and low polarization-dependent loss at around the 1560 nm optical communication band. Drop end set laser wavelength correction 1591.9 nm.

36 MATERIALS SCIENCE↗

GaN HEMT Fabrication for Radiation-Hardened Sensing and Communications Electronics

Gallium nitride (GaN), a wide bandgap semiconductor, has vast potential to address two environment conditions associated with the application of electronics to nuclear power: elevated temperatures, and high levels of radiation. A process was developed at The Ohio State University (OSU) to enable fabrication of complex digital and analog electronics circuits for application to nuclear power environments such as locations near or in the reactor core or in spent nuclear fuel casks. Radio frequency (RF)-grade GaN high electron mobility transistor (HEMT) devices were fabricated as part of this process. These were fabricated as depletion mode and enhancement mode devices. They have been electrically characterized and have demonstrated the expected performance. Behavioral models (Verilog-A) were developed from these device measurements to enable electrical simulation of GaN HEMT devices and circuits using common electronics simulation tools based on Simulation Program with Integrated Circuit Emphasis (SPICE). A similar set of GaN HEMT devices is being developed to provide lower speed devices for logic and analog functions. These accomplishments position this technology for effective application to sensor interfacing, signal processing, and data communications in nuclear power plants, including operation in or near the reactor core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Search for New Physics via EFT in collisions containing a top quark and a boosted Z or Higgs boson

We present a generator-level sensitivity study of physics beyond the Standard Model within the framework of Effective Field Theory (EFT). The targeted signal processes are single top quark production in association with a Lorentz-boosted Higgs or Z boson (tHq and tZq) in proton-proton collisions at a center-of-mass energy of 13.6 TeV. Event selection requires one electron or muon, a high-transverse-momentum, large-radius (AK8) jet reconstructing hadronic H → b̄b or Z → b̄b decays, at least two distinct, non-overlapping small-radius (AK4) jets with one originating from a b quark, and a missing transverse energy greater than 30 GeV. Signal and background samples are generated via Monte Carlo simulation using MadGraph with MadJax to perform EFT matrix-element calculations. Deviations from the Standard Model are parametrized through dimension-six EFT operators that probe modified top quark interactions. This generator-level study identifies kinematic observables with enhanced sensitivity to EFT operators and motivates future reconstruction-level analyses of tHq and tZq channels.

Meshramkar, Daniel [Baylor U., Waco]↗

Search for New Physics via EFT in collisions containing a top quark and a boosted Z or Higgs boson

We present a generator-level sensitivity study of physics beyond the Standard Model within the framework of Effective Field Theory (EFT). The targeted signal processes are single top quark production in association with a Lorentz-boosted Higgs or Z boson (tHq and tZq) in proton-proton collisions at a center-of-mass energy of 13.6 TeV. Event selection requires one electron or muon, a high-transverse-momentum, large-radius (AK8) jet reconstructing hadronic H → b̄b or Z → b̄b decays, at least two distinct, non-overlapping small-radius (AK4) jets with one originating from a b quark, and a missing transverse energy greater than 30 GeV. Signal and background samples are generated via Monte Carlo simulation using MadGraph with MadJax to perform EFT matrix-element calculations. Deviations from the Standard Model are parametrized through dimension-six EFT operators that probe modified top quark interactions. This generator-level study identifies kinematic observables with enhanced sensitivity to EFT operators and motivates future reconstruction-level analyses of tHq and tZq channels.

Meshramkar, Daniel [Baylor U., Waco]↗

Current control of light by nonreciprocal magnetoplasmonics

The ability to actively control light has long been a major scientific and technological goal. We proposed a scheme that allows for active control of light by utilizing the nonreciprocal magnetoplasmonic effect. As a proof of concept, we applied current signal through an ultrathin metallic film in a magneto-plasmonic multilayer and found that dynamic photonic nonreciprocity appears in magnetic-optical material layer due to the magnetic field being induced from current signal and modulates surface plasmon polaritons trapped in the metal surface and the light reflected. The proposed concept provides a possible way for the active control of light and could find potential applications such as ultrafast optoelectronic signal processing for plasmonic nanocircuit technology and ultrafast/large-aperture free-space electro-optic modulation platform for wireless laser communication technology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Olive oil compounds inhibit vascular endothelial growth factor receptor-2 phosphorylation

Vascular endothelial growth factor (VEGF) triggers crucial signaling processes that regulate tumor angiogenesis and, therefore, represents an attractive target for the development of novel anticancer therapeutics. Several epidemiological studies have confirmed that abundant consumption of foods from plant origin is associated with reduced risk of developing cancers. In the Mediterranean basin, the consumption of extra virgin olive oil is an important constituent of the diet. Compared to other vegetable oils, the presence of several phenolic antioxidants in olive oil is believed to prevent the occurrence of a variety of pathological processes, such as cancer. While the strong antioxidant potential of these molecules is well characterized, their antiangiogenic activities remain unknown. The aim of this study is to investigate whether tyrosol (Tyr), hydroxytyrosol (HT), taxifolin (Tax), oleuropein (OL) and oleic acid (OA), five compounds contained in extra virgin olive oil, can affect in vitro angiogenesis. We found that HT, Tax and OA were the most potent angiogenesis inhibitors through their inhibitory effect on specific autophosphorylation sites of VEGFR-2 (Tyr951, Tyr1059, Tyr1175 and Tyr1214) leading to the inhibition of endothelial cell (EC) signaling. Inhibition of VEGFR-2 by these olive oil compounds significantly reduced VEGF-induced EC proliferation and migration as well as their morphogenic differentiation into capillary-like tubular structures in Matrigel. Our study demonstrates that HT, Tax and OA are novel and potent inhibitors of the VEGFR-2 signaling pathway. These findings emphasize the chemopreventive properties of olive oil and highlight the importance of nutrition in cancer prevention. - Highlights: • We investigated five compounds contained in extra virgin olive oil on angiogenesis. • Hydroxytyrosol, taxifolin and oleic acid are the best angiogenesis inhibitors. • Olive oil compounds affect endothelial cell functions essential for angiogenesis. • Olive oil compounds inhibit specific autophosphorylation sites of VEGFR-2. • Hydroxytyrosol, taxifolin and oleic acid inhibit VEGFR-2 signaling pathway.

60 APPLIED LIFE SCIENCES↗

Mechanosensing in cell–matrix adhesions – Converting tension into chemical signals

Cell-matrix adhesions have since long been recognized to be critical for the survival and proliferation of cells. In fact, these adhesive structures do not only physically anchor cells, but they also induce vital intracellular signaling at cell-matrix adhesion sites. Recent progress in the cell adhesion field is now starting to provide data and ideas how this so far enigmatic signaling process is induced and regulated by intracellular acto-myosin tension, or stiffness of the extracellular matrix. Understanding how cells are using this mechanosignaling system will be key to control biological processes such as development, cancer growth, metastasis formation and tissue regeneration. In this review, we illustrate and discuss the mechanosignaling mechanisms important in the regulation of cell-matrix adhesions at the molecular level.

60 APPLIED LIFE SCIENCES↗

Quantum advantage for noisy channel discrimination

Many quantum mechanical experiments can be viewed as multiround interactive protocols between known quantum circuits and an unknown quantum process. Fully quantum “coherent” access to the unknown process is known to provide an advantage in many discrimination tasks compared to when only incoherent access is permitted, but it is unclear if this advantage persists when the process is noisy. Here, we show that a quantum advantage can be maintained when distinguishing between two noisy single-qubit rotation channels. Numerical and analytical calculations reveal a distinct transition between the performance of fully coherent and fully incoherent protocols as a function of noise strength. Moreover, the size of the region of coherent quantum advantage shrinks inverse polynomially in the number of channel uses, and in an intermediate regime an improved strategy is a hybrid of fully coherent and fully incoherent subroutines. The fully coherent protocol is based on quantum signal processing, suggesting a generalizable algorithmic framework for the study of quantum advantage in the presence of realistic noise.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method for evaluating bow tie filter angle-dependent attenuation in CT: Theory and simulation results

Purpose: Dosimetry in computed tomography (CT) is increasingly based on Monte Carlo studies that define the dose in the patient (in mGy) as a function of air kerma (free in air) at isocenter (mGy). The accuracy of Monte Carlo studies depends in part on the accuracy of the characterization of the bow tie filter for a given CT scanner model. A simple method for characterizing the bow tie filter attenuation profile in CT scanners would therefore be very useful. The theory behind such a method is proposed. Methods: A measurement protocol is discussed mathematically and demonstrated using computer simulation. The proposed method requires the placement of a radiation monitor at the periphery of the CT field, and the time domain signal (kerma rate versus time) is measured with good temporal resolution ({approx}200 Hz or better) and with all other objects (e.g., patient couch) retracted from the field of view. Knowledge of the source to isocenter distance (or alternately, the isocenter to probe distance) is required. The stationary detector records the kerma rate versus time signal as the gantry rotates through several revolutions. From this temporal data, signal processing techniques are used to extract in-phase peaks, as well as out-of-phase kerma rate levels. From these data, the distance from isocenter to the probe can be determined (or, alternatively, the source to isocenter distance), and the angle-dependent bow tie filter attenuation can be computed. By measuring the angle-dependent bow tie filter attenuation at several kVp settings, the bow tie composition versus fan angle can be computed using basis decomposition techniques. Results: The simulations illustrated that with 2% added noise in the kerma rate versus time signal, the attenuation properties of a hypothetical two component (aluminum and polymethyl methacrylate) bow tie filter could be determined (r{sup 2}>0.99). Although the computed basis material thicknesses were not exactly equal to the actual thicknesses, their combined attenuation factors matched that of the actual filter across kVp's to within an average of 0.057%. Conclusions: It is concluded that the proposed method may provide a simple noninvasive approach to characterizing the performance of bow tie filters in CT systems; however, experimental validation is necessary.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chirped-grating spectrometer-on-a-chip

We demonstrate an on-chip spectrometer readily integrable with CMOS electronics. The structure is comprised of a SiO 2 /Si 3 N 4 /SiO 2 waveguide atop a silicon substrate. A transversely chirped grating is fabricated, in a single-step optical lithography process, on a portion of the waveguide to provide angle and wavelength dependent coupling to the guided mode. The spectral and angular information is encoded in the spatial dependence of the grating period. A uniform pitch grating area, separated from the collection area by an unpatterned propagation region, provides the out-coupling to a CMOS detector array. A resolution of 0.3 nm at 633 nm with a spectral coverage tunable across the visible and NIR (to ∼ 1 µm limited by the Si photodetector) by changing the angle of incidence, is demonstrated without the need for any signal processing deconvolution. This on-chip spectrometer concept will cost effectively enable a broad range of applications that are beyond the reach of current integrated spectroscopic technologies.

Nezhadbadeh, Shima↗

Development of an integrated four-channel fast avalanche-photodiode detector system with nanosecond time resolution

In this paper, a four-channel nanosecond time-resolved avalanche-photodiode (APD) detector system is developed at Beijing Synchrotron Radiation. It uses a single module for signal processing and readout. This integrated system provides better reliability and flexibility for custom improvement. The detector system consists of three parts: (i) four APD sensors, (ii) four fast preamplifiers and (iii) a time-digital-converter (TDC) readout electronics. The C30703FH silicon APD chips fabricated by Excelitas are used as the sensors of the detectors. It has an effective light-sensitive area of 10 × 10 mm 2 and an absorption layer thickness of 110 μ m. A fast preamplifier with a gain of 59 dB and bandwidth of 2 GHz is designed to readout of the weak signal from the C30703FH APD. The TDC is realized by a Spartan-6 field-programmable-gate-array (FPGA) with multiphase method in a resolution of 1ns. The arrival time of all scattering events between two start triggers can be recorded by the TDC. The detector has been used for nuclear resonant scattering study at both Advanced Photon Source and also at Beijing Synchrotron Radiation Facility. Finally, for the X-ray energy of 14.4 keV, the time resolution, the full width of half maximum (FWHM) of the detector (APD sensor + fast amplifier) is 0.86 ns, and the whole detector system (APD sensors + fast amplifiers + TDC readout electronics) achieves a time resolution of 1.4 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗