Search NASA⌕ Search

SEARCH · Search NASA

Results for “SPALLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Dose dependence of mechanical properties in tantalum and tantalum alloys after low temperature irradiation

The dose dependence of mechanical properties was investigated for tantalum and tantalum alloys after low temperature irradiation. Miniature tensile specimens of three pure tantalum metals, ISIS Ta, Aesar Ta1, Aesar Ta2, and one tantalum alloy, Ta-1W, were irradiated by neutrons in the High Flux Isotope Reactor (HFIR) at ORNL to doses ranging from 0.00004 to 0.14 displacements per atom (dpa) in the temperature range 60 C 100 oC. Also, two tantalum-tungsten alloys, Ta-1W and Ta-10W, were irradiated by protons and spallation neutrons in the LANSCE facility at LANL to doses ranging from 0.7 to 7.5 dpa and from 0.7 to 25.2 dpa, respectively, in the temperature range 50 C 160 oC. Tensile tests were performed at room temperature and at 250oC at nominal strain rates of about 10-3 s-1. All neutron-irradiated materials underwent progressive irradiation hardening and loss of ductility with increasing dose. The ISIS Ta experienced embrittlement at 0.14 dpa, while the other metals retained significant necking ductility. Such a premature embrittlement in ISIS Ta is believed to be because of high initial oxygen concentrations picked up during a pre-irradiation anneal. The Ta-1W and Ta-10W specimens irradiated in spallation condition experienced prompt necking at yield since irradiation doses for those specimens were high ( 0.7 dpa). At the highest dose, 25.2 dpa, the Ta-10W alloy specimen broke with little necking strain. Among the test materials, the Ta-1W alloy displayed the best combination of strength and ductility. The plastic instability stress and true fracture stress were nearly independent of dose. Increasing test temperature decreased strength and delayed the onset of necking at yield.

36 MATERIALS SCIENCE↗

Helium and hydrogen measurements on pure materials irradiated in SINQ Target 4

Several irradiations have been performed in the Swiss Spallation Neutron Source (SINQ) to establish a materials database for mixed proton and neutron fluxes for future spallation neutron and other accelerator sources. Pure metal dosimetry materials from the second irradiation (STIP-II) have been analyzed for their total helium and hydrogen contents and their release characteristics with temperature (TDS). Total helium results are similar to those observed earlier from the first irradiation experiment (STIP-I), with concentrations ranging from ~500 to ~1,000 appm. Hydrogen contents varied over a larger range from ~100 to ~60,000 (for Ti, Nb, and Ta). 3He/4He ratios were generally consistent with expectations, except for Ti, Nb, and Ta which showed lower values due to 3He from decay of irradiation-generated tritium. Some differences were observed in the hydrogen TDS data for the control and irradiated materials, including some evidence for additional lower-temperature release and for multiple release peaks. Additionally, differences were noted in the releases for irradiated material that been cleaned versus material that had no cleaning.

08 HYDROGEN↗

Wanted! Nuclear Data for Dark Matter Astrophysics

Astronomical observations from small galaxies to the largest scales in the universe can be consistently explained by the simple idea of dark matter. The nature of dark matter is however still unknown. Empirically it cannot be any of the known particles, and many theories postulate it as a new elementary particle. Searches for dark matter particles are under way: production at high-energy accelerators, direct detection through dark matter-nucleus scattering, indirect detection through cosmic rays, gamma rays, or effects on stars. Particle dark matter searches rely on observing an excess of events above background, and a lot of controversies have arisen over the origin of observed excesses. With the new high-quality cosmic ray measurements from the AMS-02 experiment, the major uncertainty in modeling cosmic ray fluxes is in the nuclear physics cross sections for spallation and fragmentation of cosmic rays off interstellar hydrogen and helium. The understanding of direct detection backgrounds is limited by poor knowledge of cosmic ray activation in detector materials, with order of magnitude differences between simulation codes. A scarcity of data on nucleon spin densities blurs the connection between dark matter theory and experiments. What is needed, ideally, are more and better measurements of spallation cross sections relevant to cosmic rays and cosmogenic activation, and data on the nucleon spin densities in nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Practical in-situ determination of ortho-para hydrogen ratios via fiber-optic based Raman spectroscopy

An experiment was designed and developed to prototype a fiber-optic-based laser system, which measures the ratio of ortho-hydrogen to para-hydrogen in an operating neutron moderator system at the Los Alamos Neutron Science Center (LANSCE) spallation neutron source. Preliminary measurements resulted in an ortho to para ratio of 3.06:1, which is within acceptable agreement with the previously published ratio. As a result, the successful demonstration of Raman Spectroscopy for this measurement is expected to lead to a practical method that can be applied for similar in-situ measurements at operating neutron spallation sources.

43 PARTICLE ACCELERATORS↗

An unstructured mesh based neutronics optimization workflow

We have developed a fully automated workflow to optimize the neutronics performance of the Second Target Station (STS) at the Oak Ridge National Laboratory’s Spallation Neutron Source. The optimization workflow starts with the parametrized solid CAD engineering models and converts them into the unstructured mesh (UM) models for the neutronics calculations with MCNP6.2. Calculations are executed and their results are loaded into the Dakota optimization toolkit. Dakota analyzes the results and proposes new geometry parameters for the next design iteration. The cycle repeats until the optimal parameters are found. The automated CAD to MCNP conversion, the use of high-fidelity UM models, and the use of modern optimizer are the key elements that advance the entire optimization workflow in comparison with the original workflow. The original workflow was based on a simplified constructive solid geometry (CSG) modeling with MCNPX, mcnp_pstudy tool, and an in-house optimizer. Herein to demonstrate the new workflow, we present a case of neutronics optimization of the moderator–reflector assembly (MRA). Apart from the MRA, the workflow can optimize other major STS components, such as the spallation target, neutron beamlines, radiation shielding, and various accelerator components. Importantly, the new workflow opens the door to the advanced multi-physics multi-parameter optimization and has the potential for use in other nuclear physics and accelerator applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of the Second Target Station cold source moderators using an automated workflow

The Second Target Station (STS) at the US Department of Energy’s Oak Ridge National Laboratory is designed to become the world’s highest peak-brightness spallation source of cold neutrons. Successful completion of the STS, which is currently in the preliminary design phase, will provide transformative new capabilities to examine novel materials for future technologies. At STS, neutrons will be generated by spallation reactions in a solid tungsten target. They will be moderated and thermalized in two cold (20 K) para-hydrogen moderators. Careful optimization of these moderators is essential to the project’s success. To find optimal moderator designs, an advanced optimization workflow integrates high-fidelity neutronics calculations using the Monte Carlo N-Particle (MCNP) transport code MCNP6.2 with state-of-the-art optimization algorithms in the Dakota optimization toolkit. For each design iteration, a parametrized solid CAD geometry is generated in Creo and automatically converted into an unstructured mesh geometry by Attila 4MC for the neutronics calculation with MCNP. Iterations repeat until optimal designs are found. Herein this paper presents the results of a sensitivity and optimization study for the cylindrical and tube moderators. Both moderators can be optimized for maximum peak brightness, maximum time-integrated brightness, or any combination between these extremes. Maximum peak brightness is achieved by using smaller optimal dimensions of the moderators, whereas maximum time-integrated brightness is achieved by using larger dimensions. A Pareto front details the designs that optimally balance both brightness metrics. The Pareto front can be found in only 40–110 iterations with 4–5 design parameters when using the efficient global and Pareto-set optimization algorithms in Dakota. Additionally, important engineering constraints can be taken into account, such as the coupling between the cylindrical moderator radius and aluminum vessel wall thicknesses required to ensure structural integrity of the vessels. This interaction has a significant impact on the resulting optimal designs. Our new, highly efficient, fully automated optimization workflow will be used to optimize additional STS components in the future and can be adopted for design and optimization studies at other experimental neutron and accelerator facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time monitoring of the orthohydrogen fraction in a liquid hydrogen moderator

Here, we present the first direct measurements of the orthohydrogen fraction in an operating liquid hydrogen moderator loop at a high-powered neutron source. We have developed a Raman immersion probe capable of characterizing the orthohydrogen and parahydrogen makeup of a liquid hydrogen loop approximately every ten seconds, which can see orthohydrogen fractions lower than 0.20 without difficulty. At the Spallation Neutron Source, where the time-averaged power deposition in the studied moderator system is around 0.02 W/cm 3 , the orthohydrogen fraction increases with beam power and equilibrates at levels of 0.40 and responds to beam trips in a dynamic fashion. Additionally, we find that without deliberate catalyst systems in place, the relaxation due to the piping in the system has insignificant effect in catalyzing the relaxation of freshly condensed hydrogen toward thermodynamic equilibrium, and that the radiation levels associated with activation in a non-operating spallation neutron source target-moderator-reflector assembly likewise has insignificant effect on the liquid hydrogen kinetics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Modeling and Simulation Methods for Evaluation of Thermal Neutron Scattering Materials

With the rise of interest in thermal neutron scattering data for advanced reactor, criticality safety, and shielding applications, new experimental data are required for evaluation of new materials or for re-evaluation (or validations) of previously evaluated materials. New experimental data are evaluated in a three-step process: (1) computing the phonon characteristics, (2) computing the dynamic structure factor (DSF) from the data, and (3) using the experimental setup to simulate the experimental data. All three steps have challenges, ranging from the need for a sufficiently general material simulation code—a processing code that can compute the corresponding DSF—to having a detailed layout of the instrument/beamline/facility where the data were measured. Whereas phonon characteristics of materials can be computed using various methods (molecular dynamics, density functional theory, etc.), a high-fidelity computation of the DSF and the simulation of the experiment based on the DSF is vital to the accuracy of the evaluation. The latter two steps can be achieved by using the two corresponding code systems developed by instrument scientists at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory: (1) OCLIMAX, a program that calculates the dynamic structure factor from DFT and MD simulation results, and (2) MCViNE, a Monte Carlo neutron ray-tracing program designed to simulate neutron scattering experiments. Recently, polyethylene and yttrium hydride were measured at the Wide Angular-Range Chopper (ARCS) and SEQUOIA instrument stations of the SNS. These experiments are simulated using the density functional theory code, the Cambridge Serial Total Energy Package (CASTEP), to compute its phonon characteristics (eigenvalues/vectors and PDOS), which is then processed using OCLIMAX to yield the DSF, and finally the data at each instrument station are simulated by the MCViNE for comparison to the measured data for evaluation. For comparison to conventional evaluation methods, the scattering data processed from OCLIMAX are compared against those processed from the LEAPR module of NJOY, and the results from MCViNE simulations are compared against previously used simplified beamline models implemented in the Monte Carlo N-Particle (MCNP) code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pulsed Neutron Powder Diffraction for Materials Science

The accelerator-based neutron diffraction began in the end of 60's at Tohoku University which was succeeded by the four spallation neutron facilities with proton accelerators at the High Energy Accelerator Research Organization (Japan), Argonne National Laboratory and Los Alamos Laboratory (USA), and Rutherford Appleton Laboratory (UK). Since then, the next generation source has been pursued for 20 years, and 1MW-class spallation neutron sources will be appeared in about three years at the three parts of the world: Japan, UK and USA. The joint proton accelerator project (J-PARC), a collaborative project between KEK and JAEA, is one of them. The aim of the talk is to describe about J-PARC and the neutron diffractometers being installed at the materials and life science facility of J-PARC. The materials and life science facility of J-PARC has 23 neutron beam ports and will start delivering the first neutron beam of 25 Hz from 2008 May. Until now, more than 20 proposals have been reviewed by the review committee, and accepted proposal groups have started to get fund. Those proposals include five polycrystalline diffractometers: a super high resolution powder diffractometer (SHRPD), a 0.2%-resolution powder diffractometer of Ibaraki prefecture (IPD), an engineering diffractometers (Takumi), a high intensity S(Q) diffractometer (VSD), and a high-pressure dedicated diffractometer. SHRPD, Takumi and IPD are being designed and constructed by the joint team of KEK, JAEA and Ibaraki University, whose member are originally from the KEK powder group. These three instruments are expected to start in 2008. VSD is a super high intensity diffractometer with the highest resolution of {delta}d/d = 0.3%. VSD can measure rapid time-dependent phenomena of crystalline materials as well as glass, liquid and amorphous materials. The pair distribution function will be routinely obtained by the Fourier transiformation of S(Q) data. Q range of VSD will be as wide as 0.01 A{sup -1}<Q<100 A{sup -1}. IPD is fully funded by Ibaraki prefecture for the promotion of new industries based on advanced science and technologies. It is for the first time in neutron facilities in Japan that a prefecture owns neutron instruments as well as neutron beam will be provided widely to industrial users. To make it successful, the user system is quite important because those users are expected to use IPD like chemical analyzers in their materials development process. Based on questionnaire data to several hundreds industries, IPD is designed as a versatile diffractometer including texture measurement, small angle scattering and total scattering as well as usual powder diffraction. IPD covers d range 0.15<d(A)<4 with {delta}d/d 0.15%, and covers 4<d(A)<60 with gradually changing resolution. Q range of IPD will be as wide as 0.01 A{sup -1}<Q<50A{sup -1} to be utilized for varieties of structures: local structure, nano structure and crystal structure analyses. Typical measuring time for the typical 'Rietveld-quality' data is several minutes with the sample size of laboratory X-ray: 0.4 cc. SHRPD is designed to be the world highest resolution with {delta}d/d = 0.03% without sacrificing intensity. The combination of the high quality data from HRPD and their high-precision analysis gives us information on tiny structural changes which have been overlooked. After careful examination with the moderator group five years ago, we have decided to develop a high-resolution and good S/N moderator to achieve the 0.03% resolution within 100 m flight path. This development was almost successful up to now. Instrumental simulation and radiation analysis were almost completed. The d range 0.5<d(A)<4 with {delta}d/d = 0.03%, and covers 4<d(A)<45 with gradually changing resolution. Takumi is the first priority instrument in JAEA for stress mapping inside structure materials with the highest resolution of {delta}d/d = 0.2% (corresponding to 10{approx}5 to 10{approx}6 strain precision). The typical gauge volume will be 1 mm3. JED has transmission radiography detectors to support stress mapping. Software group is planning so that basic software to cover data acquisition and data treatment should be common. Since 1 Gbyte data are typically obtained for single experiment in an instrument, the basic software is quite important. International TV conference between ISIS, IPNS, SNS has been held every month to exchange information on each development. KEK developed manyo-lib to help basic analysis. Analysis software development including powder diffraction is strongly related with the activity of the software group. However, users of IPD will be from various field of science and their background is different. It should cover wide topics and help both beginners and well-trained users. We have started with neutron intensity database, peak-search software, peak-match software, pattern simulation, whole pattern fitting, PDF and RDF analysis, and now start coding Rietveld software.

36 MATERIALS SCIENCE↗

Production of light elements on a low-mass secondary in a soft X-ray transient

We examine production of light elements (Li, Be, and B) on the surface of a low-mass secondary in a black hole soft X-ray transient (BHSXT) through the spallation of CNO nuclei by neutrons which are ejected from a hot (>10 MeV) advection-dominated accretion flow (ADAF) around the black hole. Using updated binary parameters, cross sections of neutron-induced spallation reactions, and mass accretion rates in ADAFs derived from the spectrum fitting of multi-wavelength observations of quiescent BHSXTs, we obtain the equilibrium abundances of Li by equating the production rate of Li and the mass transfer rate through accretion to the black hole. We find that the resulting abundances are found to be in good agreement with the observed values in seven BHSXTs. Moreover, the isotopic ratio {sup 6}Li/{sup 7}Li and the abundance ratios Be/Li and B/Li are calculated to be about 0.7-0.8, 1.0-1.3, and 1.8-2.1, respectively, on the secondaries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evidences for Causal Decoupling between Statistical Probability and Time Scale of Fission

Fission of highly excited nuclei is affected by the viscose character of the system motion in deformation coordinates as is reported for very heavy nuclei with Z>=90. The long-time-scale fission was proved for such systems formed in heavy-ion induced reactions. The overdamped diabatic motion may influence also fission of the spallation-residue products in reactions with protons at intermediate energy. In the present work, the experimental results on blocking lifetime experiments are analyzed together with the independent data on fission-to-spallation ratios for medium-mass targets. Cross examination of the fission probability, time-scale, and pre-fission neutron multiplicity allows a new conclusion on fission mechanism. The novel approach is specified for estimate of the characteristic fission time and for the consistent interpretation of whole set of experimental results. The standard statistical approach fails for understanding of them without contradictions, though some partial data at restricted range of the encounter parameters could be described, as known from previous publications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fabrication of a Demountable TM020 Cavity from Large Grain Ingot Methods

A novel TM020 demountable test cavity has been fabricated by the Spallation Neutron Source (SNS) from large grain niobium ingot sheets. This TM020 cavity is designed to have a demountable test plate at the base of the cavity to allow for measuring RF properties as well as performing surface science analysis in an aim to develop plasma processing as a cleaning method for niobium cavities. Large grain ingot sheet fabrication methods were chosen to reduce the cost of the cavity and to produce smooth surfaces at high electric field locations with standard chemistry techniques, i.e. buffered chemical polish. A novel TM020 demountable test cavity has been fabricated by the Spallation Neutron Source (SNS) from large grain niobium ingot sheets. This TM020 cavity is designed to have a demountable test plate at the base of the cavity to allow for measuring RF properties as well as performing surface science analysis in an aim to develop plasma processing as a cleaning method for niobium cavities. Large grain ingot sheet fabrication methods were chosen to reduce the cost of the cavity and to produce smooth surfaces at high electric field locations with standard chemistry techniques, i.e. buffered chemical polish.

36 MATERIALS SCIENCE↗

The Neutron Time-Of-Flight Facility n lowbar TOF At CERN: Phase II

Neutron-induced reactions are studied at the neutron time-of-flight facility n lowbar TOF at CERN. The facility uses 6{approx}ns wide pulses of 20 GeV/c protons impinging on a lead spallation target. The large neutron energy range and the high instantaneous neutron flux combined with high resolution are among the key characteristics of the facility. After a first phase of data taking during the period 2001-2004, the facility has been refurbished with an upgraded spallation target and cooling system for a second phase of data taking which started in 2009. Since 2010, the experimental area at 185 m where the neutron beam arrives, has been modified into a worksector of type A, allowing the extension of the physics program to include neutron-induced reactions on radioactive isotopes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A look ahead: Status of the SNS external antenna ion source and the new RFQ test stand

The U.S. Spallation Neutron Source (SNS) now operates with ∼1 MW of beam power to target with the near-term goal of delivering 1.4 MW. Plans are being considered to incorporate a second target station into the facility which will require ∼2.8 MW of beam power. Presently, H{sup −} beam pulses (∼1 ms, 60 Hz) are produced by an RF-driven, Cs-enhanced, multi-cusp ion source which injects beam into an RFQ (Radio Frequency Quadrupole) accelerator that, in turn, feeds the SNS Linac. Currently the source/RFQ system delivers ∼35 mA of pulsed current to the linac which is mostly sufficient for 1.4 MW operations while ∼50 mA are needed for the second target station upgrade. This paper provides a look forward for the SNS by providing (i) the present and future SNS source/RFQ beam requirements and our plans to achieve these, (ii) a description and status of the external antenna ion source being developed for the replacement of the current internal antenna ion source, and (iii) a description and status of the newly constructed RFQ test facility.

43 PARTICLE ACCELERATORS↗

A new apparatus design for high temperature (up to 950 °C) quasi-elastic neutron scattering in a controlled gaseous environment

A design for a sample cell system suitable for high temperature Quasi-Elastic Neutron Scattering (QENS) experiments is presented. The apparatus was developed at the Spallation Neutron Source in Oak Ridge National Lab where it is currently in use. The design provides a special sample cell environment under controlled humid or dry gas flow over a wide range of temperature up to 950 °C. Using such a cell, chemical, dynamical, and physical changes can be studied in situ under various operating conditions. While the cell combined with portable automated gas environment system is especially useful for in situ studies of microscopic dynamics under operational conditions that are similar to those of solid oxide fuel cells, it can additionally be used to study a wide variety of materials, such as high temperature proton conductors. The cell can also be used in many different neutron experiments when a suitable sample holder material is selected. The sample cell system has recently been used to reveal fast dynamic processes in quasi-elastic neutron scattering experiments, which standard probes (such as electrochemical impedance spectroscopy) could not detect. In this work, we outline the design of the sample cell system and present results demonstrating its abilities in high temperature QENS experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The status of the SNS external antenna ion source and spare RFQ test facility

The Oak Ridge National Laboratory operates the Spallation Neutron Source, consisting of a H{sup −} ion source, a 1 GeV linac and an accumulator ring. The accumulated <1 μs-long, ∼35 A beam pulses are extracted from the ring at 60 Hz and directed onto a liquid Hg target. Spalled neutrons are directed to ∼20 world class instruments. Currently, the facility operates routinely with ∼1.2 MW of average beam power, which soon will be raised to 1.4 MW. A future upgrade with a second target station calls for raising the power to 2.8 MW. This paper describes the status of two accelerator components expected to play important roles in achieving these goals: a recently acquired RFQ accelerator and the external antenna ion source. Currently, the RFQ is being conditioned in a newly constructed 2.5 MeV Integrated Test Facility (ITF) and the external antenna source is also being tested on a separate test stand. This paper presents the results of experiments and the testing of these systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗