Search NASA⌕ Search

SEARCH · Search NASA

Results for “SUSPECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Identifying Reverse-Bias Breakdown Sites in CuInxGa(1-x)Se2

CIGS mini-modules are stressed under reverse bias, resembling partial shading conditions, to predict and characterize where failure occurs. Partial shading can cause permanent damage in the form of 'wormlike' defects on thin-film modules due to thermal runaway. We use electroluminescence (EL) imaging and dark lock-in thermography (DLIT) to supplement current-voltage curves when reverse-bias breakdown occurs on various CIGS minimodules. For better understanding of how these defects originate and propagate, we have implemented a current-limited, reverse-bias stressing technique. This allowed for DLIT-based detection and detailed study of the region where breakdown initiates before thermal runaway leads to permanent damage. A correlation between suspected defect sites and actual breakdown has been determined using this method.

14 SOLAR ENERGY↗

Comparison of Nb 3 Sn Insulation Systems With as Received and De-Sized Glass

Epoxy cracking has been the main suspected contributor to training in Nb 3 Sn magnets for some time, as it leads to energy release and magnet quenching. Cracking in a superconducting composite can occur from several modes, and the likelihood of these modes is not well understood. Failure has been observed between insulation systems and the superconducting cable itself rather than within the cable or insulation. To target the behavior at the interface, samples have been fabricated and tested for Mode I fracture toughness in an adapted version of ASTM D5528. This work seeks to better characterize the fracture toughness of this interface to better understand how to model and design insulation systems.

Krave, Steven T. [Fermilab] (ORCID:000000021752145↗

Adaptive Visual Sort and Summary of Micrographic Images of Nanoparticles for Forensic Analysis

Forensic analysis of nanoparticles is often conducted through the collection and identifi- cation of electron microscopy images to determine the origin of suspected nuclear material. Each image is carefully studied by experts for classification of materials based on texture, shape, and size. Manually inspecting large image datasets takes enormous amounts of time. However, automatic classification of large image datasets is a challenging problem due to the complexity involved in choosing image features, the lack of training data available for effective machine learning methods, and the availability of user interfaces to parse through images. Therefore, a significant need exists for automated and semi-automated methods to help analysts perform accurate image classification in large image datasets. We present INStINCt, our Intelligent Signature Canvas, as a framework for quickly organizing image data in a web based canvas framework. Images are partitioned using small sets of example images, chosen by users, and presented in an optimal layout based on features derived from convolutional neural networks.

active canvas↗

Scheduled Sequential Compressed Spectrum Sensing for Wideband Cognitive Radios

The support for high data rate applications with the cognitive radio technology necessitates wideband spectrum sensing. However, it is costly to apply long-term wideband sensing and is especially difficult in the presence of uncertainty, such as high noise, interference, outliers, and channel fading. In this paper, we propose scheduling of sequential compressed spectrum sensing which jointly exploits compressed sensing (CS) and sequential periodic detection techniques to achieve more accurate and timely wideband sensing. Instead of invoking CS to reconstruct the signal in each period, our proposed scheme performs backward grouped-compressed-data sequential probability ratio test (backward GCD-SPRT) using compressed data samples in sequential detection, while CS recovery is only pursued when needed. This method on one hand significantly reduces the CS recovery overhead, and on the other takes advantage of sequential detection to improve the sensing quality. Furthermore, we propose (a) an in-depth sensing scheme to accelerate sensing decision-making when a change in channel status is suspected, (b) a block-sparse CS reconstruction algorithm to exploit the block sparsity properties of wide spectrum, and (c) a set of schemes to fuse results from the recovered spectrum signals to further improve the overall sensing accuracy. Finally, extensive performance evaluation results show that our proposed schemes can significantly outperform peer schemes under sufficiently low SNR settings.

42 ENGINEERING↗

A Point Kinetics Model for Estimating Neutron Multiplication of Bare Uranium Metal in Tagged Neutron Measurements

An extension of the point kinetics model is developed in this paper to describe the neutron multiplicity response of a bare uranium object under interrogation by an associated particle imaging deuterium-tritium (D-T) measurement system. This extended model is used to estimate the total neutron multiplication of the uranium. Both MCNPX-PoliMi simulations and data from active interrogation measurements of highly enriched and depleted uranium geometries are used to evaluate the potential of this method and to identify the sources of systematic error. The detection efficiency correction for measured coincidence response is identified as a large source of systematic error. If the detection process is not considered, results suggest that the method can estimate total multiplication to within 13% of the simulated value. Values for multiplicity constants in the point kinetics equations are sensitive to enrichment due to (n, xn) interactions by D-T neutrons and can introduce another significant source of systematic bias. This can theoretically be corrected if isotopic composition is known a priori. Finally, the spatial dependence of multiplication is also suspected of introducing further systematic bias for high multiplication uranium objects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal neutron-induced single-event upsets in microcontrollers containing boron-10

Single-event upsets (SEUs) were measured in thermal neutron-irradiated microcontrollers with 65-nm node and 130-nm node SRAMs. The suspected upset mechanism is charge deposition from the energetic byproducts of 10 B thermal neutron capture. Although elemental analysis confirmed that both microcontrollers contain 10 B, only the 65-nm node microcontroller exhibited a strong response to thermal neutrons. Monte Carlo simulations were performed to investigate the effects of 11 B enrichment on thermal neutron-induced SEUs in a 65-nm SRAM node when boron is present in the p -type well, p -type source and drain, or tungsten plug. Simulations indicate that the byproducts of 10 B(n,α) 7 Li reactions are capable of generating sufficient charge to upset a 65-nm SRAM. Finally, the highest amount of charge deposition from 10 B(n,α) 7 Li reaction byproducts occurs when natural boron is used to dope the p -type source and drain regions. Simulations also show that the SEU cross section is non-negligible when 11 B-enriched boron is used for doping.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Asymmetric Dual Sensor Latency in Distributed Control

Considerable geographical separation between various phasor measurement unit sensor suites used in the wide-area damping control architecture results in time delays with varying steady-state and stochastic components. The consequences of asymmetric latent sensors used in a standard feedback configuration are presented, indicating that asymmetry of the delay provides not only a previously suspected modification to the argument of the loop transmission function, but also a potentially substantial impact on its modulus. Under particular delay configurations, the controller may experience the introduction of varying crossovers in the loop transmission, resulting in a shifting of control bandwidth and previously unconsidered (in)stability characteristics (e.g., alteration of relative stability margins). With consideration to the theoretical results provided, the optimal sensor location based on delay characteristics is provided. Finally, results of the study indicate that it is most frequently best practice to act on the most current sample in the feedback channel, rather than wait for precise time alignment of the delayed sensor.

42 ENGINEERING↗

VAST Challenge 2014: The Kronos Incident

The 2014 IEEE Visual Analytics Science and Technology (VAST) Challenge presented researchers with a single fictitious scenario: the disappearance of staff members of the GASTech oil and gas company on location on the island of Kronos. A group named the Protectors of Kronos (POK) was the prime suspect in the disappearance. Three mini-challenges and a grand challenge were offered. Mini-challenge 1 included multiple types of text data for participants to provide a timeline of key events and characterize the POK, mini-challenge 2 focused on individuals’ movement and financial data for participants to provide patterns of daily life, and mini-challenge 3 featured real-time streaming social media and emergency service data for participants to provide hostage and kidnapper information. The grand challenge asked the participants to integrate results and generate a synopsis of events. The VAST Challenge received 73 submissions from 13 countries

visual analytics, visualization, evaluation, VAST ↗

Identification and analysis of the bacterial endosymbiont specialized for production of the chemotherapeutic natural product ET-743

Ecteinascidin 743 (ET-743, Yondelis) is a clinically approved chemotherapeutic natural product isolated from the Caribbean mangrove tunicate Ecteinascidia turbinata . Researchers have long suspected that a microorganism may be the true producer of the anti-cancer drug, but its genome has remained elusive due to our inability to culture the bacterium in the laboratory using standard techniques. Here, we sequenced and assembled the complete genome of the ET-743 producer, Candidatus Endoecteinascidia frumentensis, directly from metagenomic DNA isolated from the tunicate. Analysis of the ~631 kb microbial genome revealed strong evidence of an endosymbiotic lifestyle and extreme genome reduction. Phylogenetic analysis suggested that the producer of the anti-cancer drug is taxonomically distinct from other sequenced microorganisms and could represent a new family of Gammaproteobacteria. The complete genome has also greatly expanded our understanding of ET-743 production and revealed new biosynthetic genes dispersed across more than 173 kb of the small genome. The gene cluster’s architecture and its preservation demonstrate that the drug is likely essential to the interactions of the microorganism with its mangrove tunicate host. In conclusion, taken together, these studies elucidate the lifestyle of a unique, and pharmaceutically-important microorganism and highlight the wide diversity of bacteria capable of making potent natural products.

54 ENVIRONMENTAL SCIENCES↗

Antibody dynamics to SARS‐CoV‐2 in asymptomatic COVID‐19 infections

Abstract Background The missing asymptomatic COVID‐19 infections have been overlooked because of the imperfect sensitivity of the nucleic acid testing (NAT). Globally understanding the humoral immunity in asymptomatic carriers will provide scientific knowledge for developing serological tests, improving early identification, and implementing more rational control strategies against the pandemic. Measure Utilizing both NAT and commercial kits for serum IgM and IgG antibodies, we extensively screened 11 766 epidemiologically suspected individuals on enrollment and 63 asymptomatic individuals were detected and recruited. Sixty‐three healthy individuals and 51 mild patients without any preexisting conditions were set as controls. Serum IgM and IgG profiles were further probed using a SARS‐CoV‐2 proteome microarray, and neutralizing antibody was detected by a pseudotyped virus neutralization assay system. The dynamics of antibodies were analyzed with exposure time or symptoms onset. Results A combination test of NAT and serological testing for IgM antibody discovered 55.5% of the total of 63 asymptomatic infections, which significantly raises the detection sensitivity when compared with the NAT alone (19%). Serum proteome microarray analysis demonstrated that asymptomatics mainly produced IgM and IgG antibodies against S1 and N proteins out of 20 proteins of SARS‐CoV‐2. Different from strong and persistent N‐specific antibodies, S1‐specific IgM responses, which evolved in asymptomatic individuals as early as the seventh day after exposure, peaked on days from 17 days to 25 days, and then disappeared in two months, might be used as an early diagnostic biomarker. 11.8% (6/51) mild patients and 38.1% (24/63) asymptomatic individuals did not produce neutralizing antibody. In particular, neutralizing antibody in asymptomatics gradually vanished in two months. Conclusion Our findings might have important implications for the definition of asymptomatic COVID‐19 infections, diagnosis, serological survey, public health, and immunization strategies.

Lei, Qing↗

Clinical practice gaps and challenges in non‐alcoholic steatohepatitis care: An international physician needs assessment

Abstract Background and aims Even as several pharmacological treatments for non‐alcoholic steatohepatitis (NASH) are in development, the incidence of NASH is increasing on an international scale. We aim to assess clinical practice gaps and challenges of hepatologists and endocrinologists when managing patients with NASH in four countries (Germany/Italy/United Kingdom/United States) to inform educational interventions. Methods A sequential mixed‐method design was used: qualitative semi‐structured interviews followed by quantitative online surveys. Participants were hepatologists and endocrinologists practising in one of the targeted countries. Interview data underwent thematic analysis and survey data were analysed with chi‐square and Kruskal‐Wallis tests. Results Most interviewees ( n = 24) and surveyed participants (89% of n = 224) agreed that primary care must be involved in screening for NASH, yet many faced challenges involving and collaborating with them. Endocrinologists reported low knowledge of which blood markers to use when suspecting NASH (56%), when to order an MRI (65%) or ultrasound/FibroScan® (46%), and reported sub‐optimal skills interpreting alanine aminotransferase (ALT, 37%) and aspartate aminotransferase (AST, 38%) blood marker test results, causing difficulty during diagnosis. Participants believed that more evidence is needed for upcoming therapeutic agents; yet, they reported sub‐optimal knowledge of eligibility criteria for clinical trials. Knowledge and skill gaps when managing comorbidities, as well as skill gaps facilitating patient lifestyle changes were reported. Conclusions Educational interventions are needed to address the knowledge and skill gaps identified and to develop strategies to optimize patient care, which include implementing relevant care pathways, encouraging referrals and testing, and multidisciplinary collaboration, as suggested by the recent Global Consensus statement on NAFLD.

Lazure, Patrice↗

Implementation of rapid diagnostics assays for detection of histoplasmosis and cryptococcosis in central american people living with HIV

Abstract Objectives Histoplasmosis and cryptococcosis are important public health problems in people living with HIV (PLHIV) in Central America. Conventional laboratory assays, based on microscopy and culture, are not optimal for the diagnosis of either disease. However, antigen (Ag) assays are rapid and highly accurate for the diagnosis of these infections. Methods Laboratory surveillance of PLHIV was carried out in four hospitals in Panama, Honduras and Nicaragua, between 2015 and 2019. Detection of Histoplasma antigens in urine was performed by enzyme immunoassay (EIA), and Cryptococcus antigen detection in sera and cerebrospinal fluid specimens was performed by lateral flow assay (LFA). Results A total of 4,453 PLHIV with clinical suspicion of histoplasmosis ( n = 1,343) or cryptococcosis ( n = 3,110; 2,721 sera and 389 CSF) were tested. Of 1,343 patients suspected of having histoplasmosis, 269 (20%) were Histoplasma Ag positive. Of 3,110 patients tested using the Cryptococcus Ag assay, 329 (11%) were positive. Honduras reported the highest positivity rates (32% for Histoplasma Ag, and 16% for Cryptococcus Ag); Panama reported the largest number of patients testing positive using the Histoplasma Ag assay ( n = 201); and Nicaragua reported the largest number of patients testing positive using the Cryptococcus Ag assay ( n = 170). Conclusion Here, we show how the implementation of rapid diagnostics assays impacted case detection and was useful for the care of people with advanced HIV. Rapid and accurate diagnosis could reduce mortality associated with histoplasmosis and cryptococcosis in PLHIV.

Caceres, Diego H.↗

Improved quantitation of SIMS depth profile measurements of niobium via sample holder design improvements and characterization of grain orientation effects

The importance of SIMS analyses for “N-doped” impurity alloyed niobium and other surface-alloyed materials continues to increase. A major hurdle is the uncertainty of instrument calibration due to changes in sample height either from sample surface topography or from the sample holder itself. The CAMECA sample holder design allows for many types of samples to be analyzed. However, a drawback is that the holder faceplate can bend, contributing an uncertainty in the relative sensitivity factor (RSF) used to quantify the SIMS results. Here, we describe an improved sample holder having a reinforced faceplate, which prevents deflection and reduces uncertainty. Simulations show that the new design significantly reduces deflection from 10 μm to 5 nm. Sample measurements show a reduction of RSF uncertainty from this source from 4.1% to 0.95%. Grain orientation has long been suspected to affect RSF measurement as well. A bicrystal implant standard, consisting of randomly oriented and [001] grains, was successively rotated 15° between analyses. It was observed that 20% of the analyses performed on the randomly oriented grain exhibited anomalously high RSF values as well as slow sputter rates. These features were associated with the changing grain normal orientation with respect to the primary Cs + beam. The grain orientation associated with the rise in RSF was simulated and determined to be the [101] crystallographic plane, thus indicating that ion channeling was responsible for the significantly increased RSF. Focused ion beam analysis confirmed slower sputter rates for the cardinal crystallographic orientations, indicating that ion channeling occurred for each.

43 PARTICLE ACCELERATORS↗

Benchmarking large language models for materials synthesis: The case of atomic layer deposition

In this work, we introduce an open-ended question benchmark, ALDbench, to evaluate the performance of large language models (LLMs) in materials synthesis, and, in particular, in the field of atomic layer deposition, a thin film growth technique used in energy applications and microelectronics. Our benchmark comprises questions with a level of difficulty ranging from the graduate level to domain expert current with the state of the art in the field. Human experts reviewed the questions along the criteria of difficulty and specificity, and the model responses along four different criteria: overall quality, specificity, relevance, and accuracy. We ran this benchmark on an instance of OpenAI’s GPT-4o. The responses from the model received a composite quality score of 3.7 on a 1–5 scale, consistent with a passing grade. However, 36% of the questions received at least one below average score. An in-depth analysis of the responses identified at least five instances of suspected hallucination. Finally, we observed statistically significant correlations between the difficulty of the question and the quality of the response, the difficulty of the question and the relevance of the response, the specificity of the question, and the accuracy of the response as graded by the human experts. Furthermore, this emphasizes the need to evaluate LLMs across multiple criteria beyond difficulty or accuracy.

Artificial intelligence↗

The Northwest Infrared (NWIR) gas-phase spectral database of industrial and environmental chemicals: Recent updates

With continuing improvements in both standoff- and point-sensing techniques, there is an ongoing need for high-quality infrared spectral databases. The Northwest Infrared Database (NWIR) contains quantitative, gas-phase infrared spectra of nearly 500 pure chemical species that can be used for a variety of applications such as atmospheric monitoring, biomass burning studies, etc. The data, recorded at 0.1 cm-1 resolution, are pressure broadened to one atmosphere (N2) in order to mimic atmospheric conditions. Each spectrum is a composite composed of multiple individual measurements. Recent updates to the database include over 60 molecules that are known or suspected biomass-burning effluents. Examples from this set of measurements will be presented and experimental details will be discussed in the context of the utility of NWIR for environmental applications.

quantitative infrared spectra, absorption cross-se↗

Hyperspectral vegetation identification at a legacy underground nuclear explosion test site

The detection, location, and identification of suspected underground nuclear explosions (UNEs) are global security priorities that rely on integrated analysis of multiple data modalities for uncertainty reduction in event analysis. Vegetation disturbances may provide complementary signatures that can confirm or build on the observables produced by prompt sensing techniques such as seismic or radionuclide monitoring networks. For instance, the emergence of non-native species in an area may be indicative of anthropogenic activity or changes in vegetation health may reflect changes in the site conditions resulting from an underground explosion. Previously, we collected high spatial resolution (10 cm) hyperspectral data from an unmanned aerial system at a legacy underground nuclear explosion test site and its surrounds. These data consist of visible and near-infrared wavebands over 4.3 km 2 of high desert terrain along with high spatial resolution (2.5 cm) RGB context imagery. In this work, we employ various spectral detection and classification algorithms to identify and map vegetation species in an area of interest containing the legacy test site. Here, we employed a frequentist framework for fusing multiple spectral detections across various reference spectra captured at different times and sampled from multiple locations. The spatial distribution of vegetation species is compared to the location of the underground nuclear explosion. We discover a difference in species abundance within a 130 m radius of the center of the test site.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-based Sensors for Chemical Detection

Stand-off detection of hazardous materials ensures that the responder is located at a safe distance from the suspected source. Remote detection and identification of hazardous materials can be accomplished using a highly sensitive and portable device, at significant distances downwind from the source or the threat. Optical sensing methods, in particular infrared absorption spectroscopy combined with quantum cascade lasers (QCLs), are highly suited for the detection of chemical substances since they enable rapid detection and are amenable for autonomous operation in a compact and rugged package. This talk will discuss the sensor systems developed at Pacific Northwest National Laboratory and will discuss the progress to reduce the size and power while maintaining sensitivity to enable stand-off detection of multiple chemicals.

47 OTHER INSTRUMENTATION↗

Image filtering as an alternative to the application of a different reconstruction kernel in CT imaging: Feasibility study in lung cancer screening

Purpose: While the acquisition of projection data in a computed tomography (CT) scanner is generally carried out once, the projection data is often removed from the system, making further reconstruction with a different reconstruction filter impossible. The reconstruction kernel is one of the most important parameters. To have access to all the reconstructions, either prior reconstructions with multiple kernels must be performed or the projection data must be stored. Each of these requirements would increase the burden on data archiving. This study aimed to design an effective method to achieve similar image quality using an image filtering technique in the image space, instead of a reconstruction filter in the projection space for CT imaging. The authors evaluated the clinical feasibility of the proposed method in lung cancer screening. Methods: The proposed technique is essentially the same as common image filtering, which performs processing in the spatial-frequency domain with a filter function. However, the filter function was determined based on the quantitative analysis of the point spread functions (PSFs) measured in the system. The modulation transfer functions (MTFs) were derived from the PSFs, and the ratio of the MTFs was used as the filter function. Therefore, using an image reconstructed with a kernel, an image reconstructed with a different kernel was obtained by filtering, which used the ratio of the MTFs obtained for the two kernels. The performance of the method was evaluated by using routine clinical images obtained from CT screening for lung cancer in five subjects. Results: Filtered images for all combinations of three types of reconstruction kernels (''smooth,''''standard,'' and ''sharp'' kernels) showed good agreement with original reconstructed images regarded as the gold standard. On the filtered images, abnormal shadows suspected as being lung cancers were identical to those on the reconstructed images. The standard deviations (SDs) for the difference between filtered images and reconstructed images ranged from 1.9 to 23.5 Hounsfield units for all kernel combinations; these SDs were much smaller than the noise SDs in the reconstructed images. Conclusions: The proposed method has good performance and is clinically feasible in lung cancer screening. This method can be applied to images reconstructed on any scanner by measuring the PSFs in each system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗