Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Secondary electron emission of reticulated foam materials

Complex material surfaces can reduce secondary electron emission (SEE) and sputtering via geometric trapping. In this work, the SEE yields for a range of open-cell reticulated carbon foam geometries are characterized using scanning electron microscopy. The total reduction in the SEE yield from carbon foams with a 3% volume fill density and 10–100 pores per inch (PPI) is shown to be between 23.5% and 35.0%. Contributions of a foam backplate are assessed by experimentally and analytically defining the critical parameter, transparency. The transparency of a foam is quantified and is shown to affect the primary electron angular dependence on the SEE yield. For the same thickness of 6 mm, it is found that higher PPI decreases foam transparency from 32% to 0% and reduces the SEE yield. The SEE yield from carbon foams is also shown to have weaker dependence on the morphology of the surface compared with fuzzes and velvets and less variation across individual sample surfaces due to the rigidity of their ligament structures and isotropic geometries.

Physics↗

Predicting the oxidation states of Mn ions in the oxygen-evolving complex of photosystem II using supervised and unsupervised machine learning

Abstract Serial Femtosecond Crystallography at the X-ray Free Electron Laser (XFEL) sources enabled the imaging of the catalytic intermediates of the oxygen evolution reaction of Photosystem II (PSII). However, due to the incoherent transition of the S-states, the resolved structures are a convolution from different catalytic states. Here, we train Decision Tree Classifier and K-means clustering models on Mn compounds obtained from the Cambridge Crystallographic Database to predict the S-state of the X-ray, XFEL, and CryoEM structures by predicting the Mn’s oxidation states in the oxygen-evolving complex. The model agrees mostly with the XFEL structures in the dark S 1 state. However, significant discrepancies are observed for the excited XFEL states (S 2 , S 3, and S 0 ) and the dark states of the X-ray and CryoEM structures. Furthermore, there is a mismatch between the predicted S-states within the two monomers of the same dimer, mainly in the excited states. We validated our model against other metalloenzymes, the valence bond model and the Mn spin densities calculated using density functional theory for two of the mismatched predictions of PSII. The model suggests designing a more optimized sample delivery and illumiation systems are crucial to precisely resolve the geometry of the advanced S-states to overcome the noncoherent S-state transition. In addition, significant radiation damage is observed in X-ray and CryoEM structures, particularly at the dangler Mn center (Mn4). Our model represents a valuable tool for investigating the electronic structure of the catalytic metal cluster of PSII to understand the water splitting mechanism.

Plant Sciences↗

White light interferometry for quantitative surface characterization in ion sputtering experiments.

White light interferometry (WLI) can be used to obtain surface morphology information on dimensional scale of millimeters with lateral resolution as good as {approx}1 {micro}m and depth resolution down to 1 nm. By performing true three-dimensional imaging of sample surfaces, the WLI technique enables accurate quantitative characterization of the geometry of surface features and compares favorably to scanning electron and atomic force microscopies by avoiding some of their drawbacks. In this paper, results of using the WLI imaging technique to characterize the products of ion sputtering experiments are reported. With a few figures, several example applications of the WLI method are illustrated when used for (i) sputtering yield measurements and time-to-depth conversion, (ii) optimizing ion beam current density profiles, the shapes of sputtered craters, and multiple ion beam superposition and (iii) quantitative characterization of surfaces processed with ions. In particular, for sputter depth profiling experiments of {sup 25}Mg, {sup 44}Ca and {sup 53}Cr ion implants in Si (implantation energy of 1 keV per nucleon), the depth calibration of the measured depth profile curves determined by the WLI method appeared to be self-consistent with TRIM simulations for such projectile-matrix systems. In addition, high depth resolution of the WLI method is demonstrated for a case of a Genesis solar wind Si collector surface processed by gas cluster ion beam: a 12.5 nm layer was removed from the processed surface, while the transition length between the processed and untreated areas was 150 {micro}m.

99 GENERAL AND MISCELLANEOUS↗

Temperature dependent structural and spectroscopic studies of sodium gallosilicate nitrite sodalite

We report on temperature dependent crystal structures of sodium gallosilicate nitrite sodalite Na{sub 8}[GaSiO{sub 4}]{sub 6}(NO{sub 2}){sub 2} between 293 and 973 K. The crystal structures were refined from X-ray powder data Rietveld refinements in the space group P4-bar 3n. The gallium and silicon atoms on the tetrahedral framework positions are totally ordered. The nitrite anion was found slightly away from the center of the sodalite cage, which is tetrahedrally surrounded by four sodium atoms. The linear thermal expansion coefficient was calculated from the lattice expansion data. The change of the geometries of the framework has been observed on heating the polycrystalline sample, that is, T-O bond lengths slightly decreased, T-O-T angle non-linearly increased, tilt of the TO{sub 4} tetrahedra decreased (framework untwist) and their tetragonal tetrahedral distortion decreased with some scatterings. Of particular note, the tetragonal tetrahedra distortion of GaO{sub 4} tetrahedra approached close to zero at higher temperatures, which points to a distortion direction to a relaxed state of GaO{sub 4} tetrahedra on heating. The mobility of sodium atoms above 600 K leads to different sodium content in some sodalite cages and results in the appearance of different domains. The consequence of this domain formation to the strain of the crystalline system and to the average crystals size have been explained. Both Fourier transform infrared and micro-Raman spectra showed typical absorption bands of nitrite sodalite. The change of the frequency shift and full-width at half-maximum of some selected bands has been studied as function of temperature.

36 MATERIALS SCIENCE↗

A flexible event reconstruction based on machine learning and likelihood principles

Event reconstruction is a central step in many particle physics experiments, turning detector observables into parameter estimates; for example estimating the energy of an interaction given the sensor readout of a detector. A corresponding likelihood function is often intractable, and approximations need to be constructed. Here, in our work, we first show how the full likelihood for a many-sensor detector can be broken apart into smaller terms, and secondly how we can train neural networks to approximate all terms solely based on forward simulation. Our technique results in a fast, flexible, and close-to-optimal surrogate model proportional to the likelihood and can be used in conjunction with standard inference techniques allowing for a consistent treatment of uncertainties. We illustrate our technique for parameter inference in neutrino telescopes based on maximum likelihood and Bayesian posterior sampling. Given its great flexibility, we also showcase our method for geometry optimization enabling to learn optimal detector designs. Lastly, we apply our method to realistic simulation of a ton-scale water-based liquid scintillator detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modification of semiconductor materials with the use of plasma produced by low intensity repetitive laser pulses

This work reports experiments concerning specific application of laser-produced plasma at IPPLM in Warsaw. A repetitive pulse laser system of parameters: energy up to 0.8 J in a 3.5 ns-pulse, wavelength of 1.06 {mu}m, repetition rate of up to 10 Hz, has been employed in these investigations. The characterisation of laser-produced plasma was performed with the use of 'time-of-flight' ion diagnostics simultaneously with other diagnostic methods. The results of laser-matter interaction were obtained in dependence on laser pulse parameters, illumination geometry and target material. The modified SiO{sub 2} layers and sample surface properties were characterised with the use of different methods at the Middle-East Technological University in Ankara and at the Warsaw University of technology. The production of the Ge nanocrystallites has been demonstrated for annealed samples prepared in different experimental conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical and Calorimetric Studies of Cholesterol-Rich Filamentous, Helical Ribbon and Crystal Microstructures

Formation of biological self-assemblies at all scales is a focus of studies in fields ranging from biology to physics to biomimetics. Understanding the physico-chemical properties of these self-assemblies may lead to the design of bio-inspired structures and technological applications. Here we examine self-assembled filamentous, helical ribbon, and crystal microstructures formed in chemically defined lipid concentrate (CDLC), a model system for cholesterol crystallization in gallbladder bile. CDLC consists of cholesterol, bilayer-forming amphiphiles, micelle-forming amphiphiles, and water. Phase contrast and differential interference contrast (DIC) microscopy indicate the presence of three microstructure types in all samples studied, and allow for an investigation of the structures' unique geometries. Additionally, confocal microscopy is used for qualitative assessment of surface and internal composition. To complement optical observations, calorimetric (differential-scanning and modulation) experiments, provide the basis for an in-depth understanding of collective and individual thermal behavior. Observed ''transition'' features indicate clustering and ''straightening'' of helical ribbons into short, increasingly thickening, filaments that dissolve with increasing temperature. These results suggest that all microstructures formed in CDLC may coexist in a metastable chemical equilibrium. Further investigation of the CDLC thermal profile should uncover the process of cholesterol crystallization as well as the unique design and function of microstructures formed in this system.

60 APPLIED LIFE SCIENCES↗

Contact-Free Germanium Ionization and Phonon Detectors

A new method to study the origin of the dead-layer in ionization-phonon detectors was developed wherein the ionization is measured via a 25 micron gap between the collection electrodes and germanium absorber. Phonon signals are measured with small tungsten thermometers (Tc{approx}90 mK) varnished to the Ge substrates. The Ge samples were studied using collimated {sup 241}Am sources. With this geometry, different contributions to the 'dead-layer' effect can be studied independently: Carrier back diffusion, trapping on surface states, Schottky barrier lowering, etc.

36 MATERIALS SCIENCE↗

Can theory quantitatively model stratospheric photolysis? Ab initio estimate of absolute absorption cross sections of ClOOCl

We have calculated the absorption spectrum of dichlorine peroxide (ClOOCl) in the spectral range 250-400 nm. We have employed five different approaches to quantitatively model the absorption cross section (empirical broadening scheme, linearized harmonic reflection principle and full reflection principle with ground state density calculated using harmonic approximation, classical molecular dynamics, and path-integral molecular dynamics). We have also tested various single and multireference methods. We found that (i) the excitation characteristics of ClOOCl are sensitive on molecular geometries and therefore the ground state density has to be properly sampled and that (ii) single-reference methods tend to overestimate the absorption cross section and lead to a blueshift in the absorption maximum. The absorption spectrum calculated at the CASPT2 level with complete active space-configuration interaction (CAS-SCF) transition dipole moment with the ground state sampled via path-integral molecular dynamics is in a good agreement with the experiment. We, however, did not reach full agreement in the atmospherically relevant low-energy tail of the spectrum. The general message is that quantitative predictions are difficult even for a relatively small molecule as ClOOCl and the convergence, with respect to the electronic structure method, basis set used, and ground state sampling, needs to be carefully examined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-dimensional analysis by serial sectioning of cubic zirconia sinters

Three-dimensional electron backscatter diffraction technique was used for the characterization of grain boundary geometry and pore morphology in cubic zirconia. A set of three samples composed of cubic yttria stabilized zirconia, sintered under different conditions was investigated. Analysis of grain boundaries and pore structure was carried out in a dual-beam scanning electron microscope. For each sample, a volume of 15·10{sup 3} μm{sup 3} was investigated. The results of three-dimensional microstructure analysis were compared to the results derived from regular, two-dimensional maps of the area of 2500 µm{sup 2}. Based on two-dimensional and three-dimensional data the average grain diameter, number of grains, average number of neighbors and porosity were calculated. The average grain diameter varied in the range from 2.39 µm to 2.91 µm and from 3.00 µm to 3.79 µm, while the level of porosity varied in the range from 1.22% to 1.77% and from 1.30% to 5.61% for two-dimensional and three-dimensional data, respectively. The analysis of grain boundary networks revealed a strong dependence between grain boundary density and sample preparation parameters. The parameters of the sintering process affected also the size and distribution of pores. The comparison of the results of 2D and 3D materials characterization revealed significant differences in the values of calculated microstructure parameters.

36 MATERIALS SCIENCE↗

Communication: An efficient approach to compute state-specific nuclear gradients for a generic state-averaged multi-configuration self consistent field wavefunction

We present a new, very efficient semi-numerical approach for the computation of state-specific nuclear gradients of a generic state-averaged multi-configuration self consistent field wavefunction. Our approach eliminates the costly coupled-perturbed multi-configuration Hartree-Fock step as well as the associated integral transformation stage. The details of the implementation within the Firefly quantum chemistry package are discussed and several sample applications are given. The new approach is routinely applicable to geometry optimization of molecular systems with 1000+ basis functions using a standalone multi-core workstation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A practical superconducting-microcalorimeter X-ray spectrometer for beamline and laboratory science

We describe a series of microcalorimeter X-ray spectrometers designed for a broad suite of measurement applications. The chief advantage of this type of spectrometer is that it can be orders of magnitude more efficient at collecting X-rays than more traditional high-resolution spectrometers that rely on wavelength-dispersive techniques. This advantage is most useful in applications that are traditionally photon-starved and/or involve radiation-sensitive samples. Each energy-dispersive spectrometer is built around an array of several hundred transition-edge sensors (TESs). TESs are superconducting thin films that are biased into their superconducting-to-normal-metal transitions. The spectrometers share a common readout architecture and many design elements, such as a compact, 65 mK detector package, 8-column time-division-multiplexed superconducting quantum-interference device readout, and a liquid-cryogen-free cryogenic system that is a two-stage adiabatic-demagnetization refrigerator backed by a pulse-tube cryocooler. We have adapted this flexible architecture to mate to a variety of sample chambers and measurement systems that encompass a range of observing geometries. There are two different types of TES pixels employed. The first, designed for X-ray energies below 10 keV, has a best demonstrated energy resolution of 2.1 eV (full-width-at-half-maximum or FWHM) at 5.9 keV. The second, designed for X-ray energies below 2 keV, has a best demonstrated resolution of 1.0 eV (FWHM) at 500 eV. Our team has now deployed seven of these X-ray spectrometers to a variety of light sources, accelerator facilities, and laboratory-scale experiments; these seven spectrometers have already performed measurements related to their applications. Another five of these spectrometers will come online in the near future. We have applied our TES spectrometers to the following measurement applications: synchrotron-based absorption and emission spectroscopy and energy-resolved scattering; accelerator-based spectroscopy of hadronic atoms and particle-induced-emission spectroscopy; laboratory-based time-resolved absorption and emission spectroscopy with a tabletop, broadband source; and laboratory-based metrology of X-ray-emission lines. Here, we discuss the design, construction, and operation of our TES spectrometers and show first-light measurements from the various systems. Finally, because X-ray-TES technology continues to mature, we discuss improvements to array size, energy resolution, and counting speed that we anticipate in our next generation of TES-X-ray spectrometers and beyond.

47 OTHER INSTRUMENTATION↗

A miniature multi-anvil apparatus using diamond as anvils—MDAC: Multi-axis diamond anvil cell

The diamond anvil cell (DAC) has been widely used in high-pressure research. Despite significant progress over the past five decades, the opposed anvil geometry in the DAC inevitably leads to a disk-shaped sample configuration at high pressure. This intrinsic limitation is largely responsible for the large pressure and temperature gradients in the DAC, which often compromise precise experiments and their characterizations. Here, we designed and fabricated a multi-axis diamond anvil cell (MDAC) by adopting the concept of a multi-anvil apparatus but using single crystal diamonds as the anvil material. Preliminary data show that the MDAC can generate extreme pressure conditions above 100 GPa. The advantages of the MDAC over a traditional opposed anvil DAC include thicker, voluminous samples, quasi-hydrostatic, or designed deviatoric stress conditions, and multidirectional access windows for optical applications and x-ray probes. In this article, we present the design and performance of a prototype MDAC, as well as the application prospects in high-pressure research.

47 OTHER INSTRUMENTATION↗

Correlation of electron path lengths observed in the highly wound outer region of magnetic clouds with the slab fraction of magnetic turbulence in the dissipation range

Three magnetic cloud events, in which solar impulsive electron events occurred in their outer region, are employed to investigate the difference of path lengths L {sub 0eIII} traveled by non-relativistic electrons from their release site near the Sun to the observer at 1 AU, where L {sub 0eIII} = v {sub l} × (t {sub l} – t {sub III}), v {sub l} and t {sub l} being the velocity and arrival time of electrons in the lowest energy channel (∼27 keV) of the Wind/3DP/SST sensor, respectively, and t {sub III} being the onset time of type III radio bursts. The deduced L {sub 0eIII} value ranges from 1.3 to 3.3 AU. Since a negligible interplanetary scattering level can be seen in both L {sub 0eIII} > 3 AU and ∼1.2 AU events, the difference in L {sub 0eIII} could be linked to the turbulence geometry (slab or two-dimensional) in the solar wind. By using the Wind/MFI magnetic field data with a time resolution of 92 ms, we examine the turbulence geometry in the dissipation range. In our examination, ∼6 minutes of sampled subintervals are used in order to improve time resolution. We have found that, in the transverse turbulence, the observed slab fraction is increased with an increasing L {sub 0eIII} value, reaching ∼100% in the L {sub 0eIII} > 3 AU event. Our observation implies that when only the slab spectral component exists, magnetic flux tubes (magnetic surfaces) are closed and regular for a very long distance along the transport route of particles.

79 ASTRONOMY AND ASTROPHYSICS↗

Comprehensive uncertainty quantification (UQ) for full engineering models by solving probability density function (PDF) equation

This report details a new method for propagating parameter uncertainty (forward uncertainty quantification) in partial differential equations (PDE) based computational mechanics applications. The method provides full-field quantities of interest by solving for the joint probability density function (PDF) equations which are implied by the PDEs with uncertain parameters. Full-field uncertainty quantification enables the design of complex systems where quantities of interest, such as failure points, are not known apriori. The method, motivated by the well-known probability density function (PDF) propagation method of turbulence modeling, uses an ensemble of solutions to provide the joint PDF of desired quantities at every point in the domain. A small subset of the ensemble is computed exactly, and the remainder of the samples are computed with approximation of the driving (dynamics) term of the PDEs based on those exact solutions. Although the proposed method has commonalities with traditional interpolatory stochastic collocation methods applied directly to quantities of interest, it is distinct and exploits the parameter dependence and smoothness of the dynamics term of the governing PDEs. The efficacy of the method is demonstrated by applying it to two target problems: solid mechanics explicit dynamics with uncertain material model parameters, and reacting hypersonic fluid mechanics with uncertain chemical kinetic rate parameters. A minimally invasive implementation of the method for representative codes SPARC (reacting hypersonics) and NimbleSM (finite- element solid mechanics) and associated software details are described. For solid mechanics demonstration problems the method shows order of magnitudes improvement in accuracy over traditional stochastic collocation. For the reacting hypersonics problem, the method is implemented as a streamline integration and results show very good accuracy for the approximate sample solutions of re-entry flow past the Apollo capsule geometry at Mach 30.

42 ENGINEERING↗

Deep Learning and Photogrammetric Reconstruction for Automated Crack Detection and Dimensional Measurement in Mining Operations

Surface crack detection and dimensional measurement at active mining sites present significant safety and operational challenges. Manual inspection methods are labor-intensive, spatially incomplete, and expose personnel to hazardous environments, while existing automated approaches have been developed primarily for concrete civil infrastructure and have not been validated on the complex, variable surfaces characteristic of mining environments. This dissertation presents an automated pipeline that integrates deep learning semantic segmentation with Structure-from-Motion photogrammetry to detect surface cracks and measure their aperture, length, and vertical displacement from standard RGB imagery acquired during routine Uncrewed Aerial Vehicle (UAV) survey operations, without requiring additional sensor hardware or manual measurement. The pipeline combines a U-Net architecture with an EfficientNet-B0 encoder, pretrained on the SDNET2018 concrete crack dataset and fine-tuned on a mining-specific dataset spanning laboratory concrete specimens, coal refuse impoundment embankments, and post-blast limestone quarry benches. Photogrammetric reconstruction is performed using COLMAP Structure-from-Motion and Multi-View Stereo, with crack segmentation masks projected into the reconstructed point cloud to enable three-dimensional vertical displacement measurement through local plane fitting and bimodal surface detection. The pipeline was validated across 36 controlled laboratory specimens at three imaging distances and four vertical displacement levels, achieving aperture measurement RMSE of 0.047 cm and R² of 0.954, and vertical displacement RMSE of 0.140 cm and R² of 0.966, against independent caliper measurements. Field application at a coal refuse impoundment in southwestern Pennsylvania detected 71 crack components across the embankment crest, with a dominant longitudinal crack exhibiting aperture values reaching 28 cm and a 95th percentile vertical displacement of 35.53 cm, consistent in magnitude and spatial distribution with simultaneously acquired LiDAR-derived estimates. Application across four post-blast limestone quarry bench datasets in California successfully characterized blast-induced fracture networks at ground sampling distances ranging from 0.59 to 1.23 cm/pixel, with detected crack geometries physically consistent with observable surface conditions at each site. The results demonstrate that deep learning-based crack detection and photogrammetric measurement can be integrated into routine UAV inspection workflows at mining sites, providing repeatable, scalable, and quantitative crack characterization across surface types, crack scales, and displacement magnitudes not previously addressed in the literature. The pipeline requires no dedicated surveying equipment beyond the UAV platforms already deployed at mine sites for survey and monitoring purposes, supporting practical adoption within existing operational workflows.

Crack detection, Dimensional Measurement↗

A modified Rietveld method to model highly anisotropic ceramics

High energy X-ray diffraction was employed to probe the complex constitutive behavior of a polycrystalline ferroelectric material in various sample orientations. Pb(Zn,Nb)O3-Pb(Zr,Ti)O3 (PZN-PZT) ceramics were subjected to a cyclic bipolar electric field while diffraction patterns were taken. Using transmission geometry and a two-dimensional detector, lattice strain and texture evolution (domain switching) were measured in multiple sample directions simultaneously. In addition, texture analysis suggests that non-180{sup o} domain switching is coupled with lattice strain evolution during uniaxial electrical loading. As a result of this material's high strain anisotropy, the full-pattern Rietveld method was inadequate to analyze the diffraction data. Instead, a modified Rietveld method, which includes an elastic anisotropy term, yielded significant improvements in the data analysis results.

36 MATERIALS SCIENCE↗

Calculation of the Geometric Factor in a New Experiment Aimed at Studying Radiative Neutron Decay

A new experiment aimed at studying radiative neutron decay is proposed. The respective experimental procedure reduces to measuring the time spectra of triple coincidences of the emitted photon, beta electron, and recoil proton along with the spectrum of double coincidences of ordinary decay products. By means of this procedure, we were able to measure for the first time the branching ratio for radiative neutron decay, BR = (3.2 ± 1.6) × 10{sup −3} (at a confidence level of C.L. = 99.7%, the photon energy being in excess of 35 keV) in 2005 at our old setup. The average value of this branching ratio was greater by a factor of 1.5 than its theoretical counterpart calculated on the basis of the Standard Model. However, we cannot state that we have seen a deviation fromthe StandardModel prediction since the experimental error was quite large in that experiment. The present study is devoted to implementing, by means of the popular Geant4 code package, a computer analog of the respective experiment at a new facility. Our calculations reveal that the resulting geometri©factor values make it possible to a accumulate, in a live experiment, a data sample sufficient for measuring the above branching ratio to a precision of a few percent.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗