Search NASA⌕ Search

SEARCH · Search NASA

Results for “Simulation Radiological Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Potential Effect of Robust and Simple IMRT Approach for Left-Sided Breast Cancer on Cardiac Mortality

Purpose: Three-dimensional (3D) treatment planning has reduced the cardiac dose in postoperative radiotherapy for breast cancer; however, the overall cardiac toxicity is still an issue because of more aggressive adjuvant treatment. Toxicity models have suggested that a reduction of the heart volume treated to high doses might be particularly advantageous. We compared aperture-based multifield intensity-modulated radiotherapy (IMRT) plans to 3D-planned tangent fields using dose-volume histograms, cardiac toxicity risk, and the robustness to positioning errors. Methods and Materials: For 14 computed tomography data sets of patients with left-sided breast cancer (unfavorable thoracic geometry), a 3D treatment plan and an IMRT plan were created. The dose-volume histograms were evaluated for the target and risk organs. Excess risk of cardiac mortality was calculated for both approaches using a relative seriality model. Positioning errors were simulated by moving the isocenter. Results: IMRT reduced the maximal dose to the left ventricle by a mean of 30.9% (49.14 vs. 33.97 Gy). The average heart volume exposed to >30 Gy was reduced from 45 cm{sup 3} to 5.84 cm{sup 3}. The mean dose to the left ventricle was reduced by an average of 10.7% (10.86 vs. 9.7 Gy), and the mean heart dose increased by an average of 24% (from 6.85 to 8.52 Gy). The model-based reduction of the probability for excess therapy-associated cardiac death risk was from 6.03% for the 3D plans to 0.25% for the IMRT plans. Conclusion: Aperture-based IMRT for left-sided breast cancer significantly reduces the maximal dose to the left ventricle, which might translate into reduced cardiac mortality. Biological modeling might aid in deciding to treat with IMRT but has to be validated prospectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Machine Learning Approaches for Predicting Radiation Therapy Outcomes: A Clinician's Perspective

Radiation oncology has always been deeply rooted in modeling, from the early days of isoeffect curves to the contemporary Quantitative Analysis of Normal Tissue Effects in the Clinic (QUANTEC) initiative. In recent years, medical modeling for both prognostic and therapeutic purposes has exploded thanks to increasing availability of electronic data and genomics. One promising direction that medical modeling is moving toward is adopting the same machine learning methods used by companies such as Google and Facebook to combat disease. Broadly defined, machine learning is a branch of computer science that deals with making predictions from complex data through statistical models. These methods serve to uncover patterns in data and are actively used in areas such as speech recognition, handwriting recognition, face recognition, “spam” filtering (junk email), and targeted advertising. Although multiple radiation oncology research groups have shown the value of applied machine learning (ML), clinical adoption has been slow due to the high barrier to understanding these complex models by clinicians. Here, we present a review of the use of ML to predict radiation therapy outcomes from the clinician's point of view with the hope that it lowers the “barrier to entry” for those without formal training in ML. We begin by describing 7 principles that one should consider when evaluating (or creating) an ML model in radiation oncology. We next introduce 3 popular ML methods—logistic regression (LR), support vector machine (SVM), and artificial neural network (ANN)—and critique 3 seminal papers in the context of these principles. Although current studies are in exploratory stages, the overall methodology has progressively matured, and the field is ready for larger-scale further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intermediate energy photons (1 MV) to improve dose gradient, conformality, and homogeneity: Potential benefits for small field intracranial radiosurgery

A previously conceived and demonstrated principle of reducing penumbra for small radiosurgical dose fields is here now applied to a multiple beam arrangement in a stereotactic head phantom. In this work it is found that the fourfold reduction in radiological penumbra of small, single 1 MV x-ray fields translates to a more conformal, homogeneous dose distribution in the more complex beam arrangements. The film dosimetry is conducted with a high resolution digital microscope to quantify the sharp dose gradients. Further, the Gafchromic EBT film measurements in phantom are compared to calculations using the Xknife RT3 (Radionics, Burlington, MA) treatment planning software (TPS) with modeled 1 MV beam data. An orthogonal pair of coplanar beams and an 18-beam coplanar arc irradiation both yielded agreement between the modeling within the TPS and the film work. Conventional 6 MV modality is compared alongside 1 MV throughout. The 90%-50% and 90%-10% dose gradients at the intersection of the orthogonal beam pair were 1.7 and 4.7 mm for 6 MV versus 0.5 and 1.3 mm for 1 MV for an identical setup. The 18-beam coplanar arc plan yielded 90%-80% and 90%-50% dose gradients of 0.84 and 2.2 mm for 6 MV versus gradients of 0.29 and 1.36 mm for 1 MV for the midaxial slice coplanar with all beamlet axes. Uncertainties in gradient measurements were {+-}0.15 mm. The 18-beam coplanar beam arrangement represented a worst case scenario for penumbra overlap deteriorating the dose distribution. In brief, 1 MV x-rays provided superior homogeneity, conformality, and dose fall-off to 6 MV for the irradiations examined.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-I-56: Scan Angle Reduction for a Limited-Angle Intrafraction Verification (LIVE) System

Purpose: To develop a novel adaptive reconstruction strategy to further reduce the scanning angle required by the limited-angle intrafraction verification (LIVE) system for intrafraction verification. Methods: LIVE acquires limited angle MV projections from the exit fluence of the arc treatment beam or during gantry rotation between static beams. Orthogonal limited-angle kV projections are also acquired simultaneously to provide additional information. LIVE considers the on-board 4D-CBCT images as a deformation of the prior 4D-CT images, and solves the deformation field based on deformation models and data fidelity constraint. LIVE reaches a checkpoint after a limited-angle scan, and reconstructs 4D-CBCT for intrafraction verification at the checkpoint. In adaptive reconstruction strategy, a larger scanning angle of 30° is used for the first checkpoint, and smaller scanning angles of 15° are used for subsequent checkpoints. The onboard images reconstructed at the previous adjacent checkpoint are used as the prior images for reconstruction at the current checkpoint. As the algorithm only needs to reconstruct the small deformation occurred between adjacent checkpoints, projections from a smaller scan angle provide enough information for the reconstruction. XCAT was used to simulate tumor motion baseline drift of 2mm along sup-inf direction at every subsequent checkpoint, which are 15° apart. Adaptive reconstruction strategy was used to reconstruct the images at each checkpoint using orthogonal 15° kV and MV projections. Results: Results showed that LIVE reconstructed the tumor volumes accurately using orthogonal 15° kV-MV projections. Volume percentage differences (VPDs) were within 5% and center of mass shifts (COMS) were within 1mm for reconstruction at all checkpoints. Conclusion: It's feasible to use an adaptive reconstruction strategy to further reduce the scan angle needed by LIVE to allow faster and more frequent intrafraction verification to minimize the treatment errors in lung cancer treatments. Grant from Varian Medical System.

60 APPLIED LIFE SCIENCES↗

Medical Device Recalls in Radiation Oncology: Analysis of US Food and Drug Administration Data, 2002-2015

Purpose: To analyze all recalls involving radiation oncology devices (RODs) from the US Food and Drug Administration (FDA)'s recall database, comparing these with non–radiation oncology device recalls to identify discipline-specific trends that may inform improvements in device safety. Methods and Materials: Recall data on RODs from 2002 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems). Outcomes included determined cause of recall, recall class (severity), quantity in commerce, time until recall termination (date FDA determines recall is complete), and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by Pearson χ{sup 2} test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 502 ROD recalls and 9534 other class II device recalls during 2002 to 2015. Most recalls were for external beam devices (66.7%) and planning systems (22.9%), and recall events peaked in 2011. Radiation oncology devices differed significantly from other devices in all recall outcomes (P≤.04). Recall cause was commonly software related (49% vs 10% for other devices). Recall severity was more often moderate among RODs (97.6% vs 87.2%) instead of severe (0.2% vs 4.4%; P<.001). Time from 510(k) market approval to recall was shorter among RODs (P<.001) and progressively shortened over time. Radiation oncology devices had fewer recalled devices in commerce than other devices (P<.001). Conclusions: Compared with other class II devices, RODs experience recalls sooner after market approval and are trending sooner still. Most of these recalls were moderate in severity, and software issues are prevalent. Comprehensive analysis of recall data can identify areas for device improvement, such as better system design among RODs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Small Tolerance for Catheter Displacement in High-Dose Rate Prostate Brachytherapy is Necessary and Feasible

Purpose: We examined catheter displacement in patients treated with fractionated high-dose rate (HDR) brachytherapy boost for prostate cancer and the impact this had on tumor control probability (TCP). These data were used to make conclusions on an acceptable amount of displacement. Methods and Materials: The last 20 patients treated with HDR brachytherapy boost for prostate cancer at our center in 2007 were replanned using simulated interstitial catheter displacements of 3, 6, 9, and 12 mm with originally planned dwell times. The computer-modeled dose-volume histograms for the clinical target volumes were exported and used to calculate the TCP of plans with displaced needles relative to the original plan. Actual catheter displacements were also measured before and after manual adjustment in all patients treated in 2007. Results: In the 20 patients who were replanned for caudal catheter displacements of 3, 6, 9, and 12 mm, the median relative TCP was 0.998, 0.964, 0.797, and 0.265, respectively (p < 0.01 when all medians were compared). All patients replanned with a 3-mm displacement, compared with only 75% with a 6-mm displacement, had a relative TCP greater than 0.950. In the 91 patients treated in 2007, before adjustment, 82.3% of fractions had a displacement greater than 3 mm compared with 12.2% of fractions after adjustment. Conclusions: Catheter displacement in HDR brachytherapy significantly compromises the TCP. The tolerance for these movements should be small (<=3 mm). Correcting these displacements to within acceptable limits is feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simple Method to Estimate Mean Heart Dose From Hodgkin Lymphoma Radiation Therapy According to Simulation X-Rays

Purpose: To describe a new method to estimate the mean heart dose for Hodgkin lymphoma patients treated several decades ago, using delineation of the heart on radiation therapy simulation X-rays. Mean heart dose is an important predictor for late cardiovascular complications after Hodgkin lymphoma (HL) treatment. For patients treated before the era of computed tomography (CT)-based radiotherapy planning, retrospective estimation of radiation dose to the heart can be labor intensive. Methods and Materials: Patients for whom cardiac radiation doses had previously been estimated by reconstruction of individual treatments on representative CT data sets were selected at random from a case–control study of 5-year Hodgkin lymphoma survivors (n=289). For 42 patients, cardiac contours were outlined on each patient's simulation X-ray by 4 different raters, and the mean heart dose was estimated as the percentage of the cardiac contour within the radiation field multiplied by the prescribed mediastinal dose and divided by a correction factor obtained by comparison with individual CT-based dosimetry. Results: According to the simulation X-ray method, the medians of the mean heart doses obtained from the cardiac contours outlined by the 4 raters were 30 Gy, 30 Gy, 31 Gy, and 31 Gy, respectively, following prescribed mediastinal doses of 25-42 Gy. The absolute-agreement intraclass correlation coefficient was 0.93 (95% confidence interval 0.85-0.97), indicating excellent agreement. Mean heart dose was 30.4 Gy with the simulation X-ray method, versus 30.2 Gy with the representative CT-based dosimetry, and the between-method absolute-agreement intraclass correlation coefficient was 0.87 (95% confidence interval 0.80-0.95), indicating good agreement between the two methods. Conclusion: Estimating mean heart dose from radiation therapy simulation X-rays is reproducible and fast, takes individual anatomy into account, and yields results comparable to the labor-intensive representative CT-based method. This simpler method may produce a meaningful measure of mean heart dose for use in studies of late cardiac complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fan-beam intensity modulated proton therapy

Purpose: This paper presents a concept for a proton therapy system capable of delivering intensity modulated proton therapy using a fan beam of protons. This system would allow present and future gantry-based facilities to deliver state-of-the-art proton therapy with the greater normal tissue sparing made possible by intensity modulation techniques.Methods: A method for producing a divergent fan beam of protons using a pair of electromagnetic quadrupoles is described and particle transport through the quadrupole doublet is simulated using a commercially available software package. To manipulate the fan beam of protons, a modulation device is developed. This modulator inserts or retracts acrylic leaves of varying thickness from subsections of the fan beam. Each subsection, or beam channel, creates what effectively becomes a beam spot within the fan area. Each channel is able to provide 0–255 mm of range shift for its associated beam spot, or stop the beam and act as an intensity modulator. Results of particle transport simulations through the quadrupole system are incorporated into the MCNPX Monte Carlo transport code along with a model of the range and intensity modulation device. Several design parameters were investigated and optimized, culminating in the ability to create topotherapy treatment plans using distal-edge tracking on both phantom and patient datasets.Results: Beam transport calculations show that a pair of electromagnetic quadrupoles can be used to create a divergent fan beam of 200 MeV protons over a distance of 2.1 m. The quadrupole lengths were 30 and 48 cm, respectively, with transverse field gradients less than 20 T/m, which is within the range of water-cooled magnets for the quadrupole radii used. MCNPX simulations of topotherapy treatment plans suggest that, when using the distal edge tracking delivery method, many delivery angles are more important than insisting on narrow beam channel widths in order to obtain conformal target coverage. Overall, the sharp distal falloff of a proton depth-dose distribution was found to provide sufficient control over the dose distribution to meet objectives, even with coarse lateral resolution and channel widths as large as 2 cm. Treatment plans on both phantom and patient data show that dose conformity suffers when treatments are delivered from less than approximately ten angles. Treatment time for a sample prostate delivery is estimated to be on the order of 10 min, and neutron production is estimated to be comparable to that found for existing collimated systems.Conclusions: Fan beam proton therapy is a method of delivering intensity modulated proton therapy which may be employed as an alternative to magnetic scanning systems. A fan beam of protons can be created by a set of quadrupole magnets and modified by a dual-purpose range and intensity modulator. This can be used to deliver inversely planned treatments, with spot intensities optimized to meet user defined dose objectives. Additionally, the ability of a fan beam delivery system to effectively treat multiple beam spots simultaneously may provide advantages as compared to spot scanning deliveries.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-10: A Moving-Blocker-Based Strategy for Simultaneous Megavoltage and Kilovoltage Scatter Correction in Cone-Beam Computed Tomography Image Acquired During Volumetric Modulated Arc Therapy

Purpose: To evaluate a moving-blocker-based approach in estimating and correcting megavoltage (MV) and kilovoltage (kV) scatter contamination in kV cone-beam computed tomography (CBCT) acquired during volumetric modulated arc therapy (VMAT). Methods: XML code was generated to enable concurrent CBCT acquisition and VMAT delivery in Varian TrueBeam developer mode. A physical attenuator (i.e., “blocker”) consisting of equal spaced lead strips (3.2mm strip width and 3.2mm gap in between) was mounted between the x-ray source and patient at a source to blocker distance of 232mm. The blocker was simulated to be moving back and forth along the gantry rotation axis during the CBCT acquisition. Both MV and kV scatter signal were estimated simultaneously from the blocked regions of the imaging panel, and interpolated into the un-blocked regions. Scatter corrected CBCT was then reconstructed from un-blocked projections after scatter subtraction using an iterative image reconstruction algorithm based on constraint optimization. Experimental studies were performed on a Catphan 600 phantom and an anthropomorphic pelvis phantom to demonstrate the feasibility of using moving blocker for MV-kV scatter correction. Results: MV scatter greatly degrades the CBCT image quality by increasing the CT number inaccuracy and decreasing the image contrast, in addition to the shading artifacts caused by kV scatter. The artifacts were substantially reduced in the moving blocker corrected CBCT images in both Catphan and pelvis phantoms. Quantitatively, CT number error in selected regions of interest reduced from 377 in the kV-MV contaminated CBCT image to 38 for the Catphan phantom. Conclusions: The moving-blockerbased strategy can successfully correct MV and kV scatter simultaneously in CBCT projection data acquired with concurrent VMAT delivery. This work was supported in part by a grant from the Cancer Prevention and Research Institute of Texas (RP130109) and a grant from the American Cancer Society (RSG-13-326-01-CCE)

60 APPLIED LIFE SCIENCES↗

Delivery confirmation of bolus electron conformal therapy combined with intensity modulated x-ray therapy

Purpose: The purpose of this study was to demonstrate that a bolus electron conformal therapy (ECT) dose plan and a mixed beam plan, composed of an intensity modulated x-ray therapy (IMXT) dose plan optimized on top of the bolus ECT plan, can be accurately delivered. Methods: Calculated dose distributions were compared with measured dose distributions for parotid and chest wall (CW) bolus ECT and mixed beam plans, each simulated in a cylindrical polystyrene phantom that allowed film dose measurements. Bolus ECT plans were created for both parotid and CW PTVs (planning target volumes) using 20 and 16 MeV beams, respectively, whose 90% dose surface conformed to the PTV. Mixed beam plans consisted of an IMXT dose plan optimized on top of the bolus ECT dose plan. The bolus ECT, IMXT, and mixed beam dose distributions were measured using radiographic films in five transverse and one sagittal planes for a total of 36 measurement conditions. Corrections for film dose response, effects of edge-on photon irradiation, and effects of irregular phantom optical properties on the Cerenkov component of the film signal resulted in high precision measurements. Data set consistency was verified by agreement of depth dose at the intersections of the sagittal plane with the five measured transverse planes. For these same depth doses, results for the mixed beam plan agreed with the sum of the individual depth doses for the bolus ECT and IMXT plans. The six mean measured planar dose distributions were compared with those calculated by the treatment planning system for all modalities. Dose agreement was assessed using the 4% dose difference and 0.2 cm distance to agreement. Results: For the combined high-dose region and low-dose region, pass rates for the parotid and CW plans were 98.7% and 96.2%, respectively, for the bolus ECT plans and 97.9% and 97.4%, respectively, for the mixed beam plans. For the high-dose gradient region, pass rates for the parotid and CW plans were 93.1% and 94.62%, respectively, for the bolus ECT plans and 89.2% and 95.1%, respectively, for the mixed beam plans. For all regions, pass rates for the parotid and CW plans were 98.8% and 97.3%, respectively, for the bolus ECT plans and 97.5% and 95.9%, respectively, for the mixed beam plans. For the IMXT component of the mixed beam plans, pass rates for the parotid and CW plans were 93.7% and 95.8%. Conclusions: Bolus ECT and mixed beam therapy dose delivery to the phantom were more accurate than IMXT delivery, adding confidence to the use of planning, fabrication, and delivery for bolus ECT tools either alone or as part of mixed beam therapy. The methodology reported in this work could serve as a basis for future standardization of the commissioning of bolus ECT or mixed beam therapy. When applying this technology to patients, it is recommended that an electron dose algorithm more accurate than the pencil beam algorithm, e.g., a Monte Carlo algorithm or analytical transport such as the pencil beam redefinition algorithm, be used for planning to ensure the desired accuracy.

60 APPLIED LIFE SCIENCES↗

Adaptive error detection for HDR/PDR brachytherapy: Guidance for decision making during real-time in vivo point dosimetry

Purpose: This study presents an adaptive error detection algorithm (AEDA) for real-timein vivo point dosimetry during high dose rate (HDR) or pulsed dose rate (PDR) brachytherapy (BT) where the error identification, in contrast to existing approaches, does not depend on an a priori reconstruction of the dosimeter position. Instead, the treatment is judged based on dose rate comparisons between measurements and calculations of the most viable dosimeter position provided by the AEDA in a data driven approach. As a result, the AEDA compensates for false error cases related to systematic effects of the dosimeter position reconstruction. Given its nearly exclusive dependence on stable dosimeter positioning, the AEDA allows for a substantially simplified and time efficient real-time in vivo BT dosimetry implementation. Methods: In the event of a measured potential treatment error, the AEDA proposes the most viable dosimeter position out of alternatives to the original reconstruction by means of a data driven matching procedure between dose rate distributions. If measured dose rates do not differ significantly from the most viable alternative, the initial error indication may be attributed to a mispositioned or misreconstructed dosimeter (false error). However, if the error declaration persists, no viable dosimeter position can be found to explain the error, hence the discrepancy is more likely to originate from a misplaced or misreconstructed source applicator or from erroneously connected source guide tubes (true error). Results: The AEDA applied on twoin vivo dosimetry implementations for pulsed dose rate BT demonstrated that the AEDA correctly described effects responsible for initial error indications. The AEDA was able to correctly identify the major part of all permutations of simulated guide tube swap errors and simulated shifts of individual needles from the original reconstruction. Unidentified errors corresponded to scenarios where the dosimeter position was sufficiently symmetric with respect to error and no-error source position constellations. The AEDA was able to correctly identify all false errors represented by mispositioned dosimeters contrary to an error detection algorithm relying on the original reconstruction. Conclusions: The study demonstrates that the AEDA error identification during HDR/PDR BT relies on a stable dosimeter position rather than on an accurate dosimeter reconstruction, and the AEDA’s capacity to distinguish between true and false error scenarios. The study further shows that the AEDA can offer guidance in decision making in the event of potential errors detected with real-timein vivo point dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adverse Events Involving Radiation Oncology Medical Devices: Comprehensive Analysis of US Food and Drug Administration Data, 1991 to 2015

Purpose: Radiation oncology relies on rapidly evolving technology and highly complex processes. The US Food and Drug Administration collects reports of adverse events related to medical devices. We sought to characterize all events involving radiation oncology devices (RODs) from the US Food and Drug Administration's postmarket surveillance Manufacturer and User Facility Device Experience (MAUDE) database, comparing these with non–radiation oncology devices. Methods and Materials: MAUDE data on RODs from 1991 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems) and 5 device problem categories (software, mechanical, electrical, user error, and dose delivery impact). Outcomes included whether the device was evaluated by the manufacturer, adverse event type, remedial action, problem code, device age, and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by the Pearson χ{sup 2} test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 4234 ROD and 4,985,698 other device adverse event reports. Adverse event reports increased over time, and events involving RODs peaked in 2011. Most ROD reports involved external beam therapy (50.8%), followed by brachytherapy (24.9%) and treatment planning systems (21.6%). The top problem types were software (30.4%), mechanical (20.9%), and user error (20.4%). RODs differed significantly from other devices in each outcome (P<.001). RODs were more likely to be evaluated by the manufacturer after an event (46.9% vs 33.0%) but less likely to be recalled (10.5% vs 37.9%) (P<.001). Device age and time since 510(k) approval were shorter among RODs (P<.001). Conclusions: Compared with other devices, RODs may experience adverse events sooner after manufacture and market approval. Close postmarket surveillance, improved software design, and manufacturer–user training may help mitigate these events.

07 ISOTOPE AND RADIATION SOURCES↗

Transconvolution and the virtual positron emission tomograph-A new method for cross calibration in quantitative PET/CT imaging

Purpose: Positron emission tomography (PET)/computed tomography (CT) measurements on small lesions are impaired by the partial volume effect, which is intrinsically tied to the point spread function of the actual imaging system, including the reconstruction algorithms. The variability resulting from different point spread functions hinders the assessment of quantitative measurements in clinical routine and especially degrades comparability within multicenter trials. To improve quantitative comparability there is a need for methods to match different PET/CT systems through elimination of this systemic variability. Consequently, a new method was developed and tested that transforms the image of an object as produced by one tomograph to another image of the same object as it would have been seen by a different tomograph. The proposed new method, termed Transconvolution, compensates for differing imaging properties of different tomographs and particularly aims at quantitative comparability of PET/CT in the context of multicenter trials. Methods: To solve the problem of image normalization, the theory of Transconvolution was mathematically established together with new methods to handle point spread functions of different PET/CT systems. Knowing the point spread functions of two different imaging systems allows determining a Transconvolution function to convert one image into the other. This function is calculated by convolving one point spread function with the inverse of the other point spread function which, when adhering to certain boundary conditions such as the use of linear acquisition and image reconstruction methods, is a numerically accessible operation. For reliable measurement of such point spread functions characterizing different PET/CT systems, a dedicated solid-state phantom incorporating {sup 68}Ge/{sup 68}Ga filled spheres was developed. To iteratively determine and represent such point spread functions, exponential density functions in combination with a Gaussian distribution were introduced. Furthermore, simulation of a virtual PET system provided a standard imaging system with clearly defined properties to which the real PET systems were to be matched. A Hann window served as the modulation transfer function for the virtual PET. The Hann's apodization properties suppressed high spatial frequencies above a certain critical frequency, thereby fulfilling the above-mentioned boundary conditions. The determined point spread functions were subsequently used by the novel Transconvolution algorithm to match different PET/CT systems onto the virtual PET system. Finally, the theoretically elaborated Transconvolution method was validated transforming phantom images acquired on two different PET systems to nearly identical data sets, as they would be imaged by the virtual PET system. Results: The proposed Transconvolution method matched different PET/CT-systems for an improved and reproducible determination of a normalized activity concentration. The highest difference in measured activity concentration between the two different PET systems of 18.2% was found in spheres of 2 ml volume. Transconvolution reduced this difference down to 1.6%. In addition to reestablishing comparability the new method with its parameterization of point spread functions allowed a full characterization of imaging properties of the examined tomographs. Conclusions: By matching different tomographs to a virtual standardized imaging system, Transconvolution opens a new comprehensive method for cross calibration in quantitative PET imaging. The use of a virtual PET system restores comparability between data sets from different PET systems by exerting a common, reproducible, and defined partial volume effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FBP and BPF reconstruction methods for circular X-ray tomography with off-center detector

Purpose: Circular scanning with an off-center planar detector is an acquisition scheme that allows to save detector area while keeping a large field of view (FOV). Several filtered back-projection (FBP) algorithms have been proposed earlier. The purpose of this work is to present two newly developed back-projection filtration (BPF) variants and evaluate the image quality of these methods compared to the existing state-of-the-art FBP methods. Methods: The first new BPF algorithm applies redundancy weighting of overlapping opposite projections before differentiation in a single projection. The second one uses the Katsevich-type differentiation involving two neighboring projections followed by redundancy weighting and back-projection. An averaging scheme is presented to mitigate streak artifacts inherent to circular BPF algorithms along the Hilbert filter lines in the off-center transaxial slices of the reconstructions. The image quality is assessed visually on reconstructed slices of simulated and clinical data. Quantitative evaluation studies are performed with the Forbild head phantom by calculating root-mean-squared-deviations (RMSDs) to the voxelized phantom for different detector overlap settings and by investigating the noise resolution trade-off with a wire phantom in the full detector and off-center scenario. Results: The noise-resolution behavior of all off-center reconstruction methods corresponds to their full detector performance with the best resolution for the FDK based methods with the given imaging geometry. With respect to RMSD and visual inspection, the proposed BPF with Katsevich-type differentiation outperforms all other methods for the smallest chosen detector overlap of about 15 mm. The best FBP method is the algorithm that is also based on the Katsevich-type differentiation and subsequent redundancy weighting. For wider overlap of about 40-50 mm, these two algorithms produce similar results outperforming the other three methods. The clinical case with a detector overlap of about 17 mm confirms these results. Conclusions: The BPF-type reconstructions with Katsevich differentiation are widely independent of the size of the detector overlap and give the best results with respect to RMSD and visual inspection for minimal detector overlap. The increased homogeneity will improve correct assessment of lesions in the entire field of view.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise suppressed partial volume correction for cardiac SPECT/CT

Purpose: Partial volume correction (PVC) methods typically improve quantification at the expense of increased image noise and reduced reproducibility. In this study, the authors developed a novel voxel-based PVC method that incorporates anatomical knowledge to improve quantification while suppressing noise for cardiac SPECT/CT imaging. Methods: In the proposed method, the SPECT images were first reconstructed using anatomical-based maximum a posteriori (AMAP) with Bowsher’s prior to penalize noise while preserving boundaries. A sequential voxel-by-voxel PVC approach (Yang’s method) was then applied on the AMAP reconstruction using a template response. This template response was obtained by forward projecting a template derived from a contrast-enhanced CT image, and then reconstructed using AMAP to model the partial volume effects (PVEs) introduced by both the system resolution and the smoothing applied during reconstruction. To evaluate the proposed noise suppressed PVC (NS-PVC), the authors first simulated two types of cardiac SPECT studies: a {sup 99m}Tc-tetrofosmin myocardial perfusion scan and a {sup 99m}Tc-labeled red blood cell (RBC) scan on a dedicated cardiac multiple pinhole SPECT/CT at both high and low count levels. The authors then applied the proposed method on a canine equilibrium blood pool study following injection with {sup 99m}Tc-RBCs at different count levels by rebinning the list-mode data into shorter acquisitions. The proposed method was compared to MLEM reconstruction without PVC, two conventional PVC methods, including Yang’s method and multitarget correction (MTC) applied on the MLEM reconstruction, and AMAP reconstruction without PVC. Results: The results showed that the Yang’s method improved quantification, however, yielded increased noise and reduced reproducibility in the regions with higher activity. MTC corrected for PVE on high count data with amplified noise, although yielded the worst performance among all the methods tested on low-count data. AMAP effectively suppressed noise and reduced the spill-in effect in the low activity regions. However it was unable to reduce the spill-out effect in high activity regions. NS-PVC yielded superior performance in terms of both quantitative assessment and visual image quality while improving reproducibility. Conclusions: The results suggest that NS-PVC may be a promising PVC algorithm for application in low-dose protocols, and in gated and dynamic cardiac studies with low counts.

60 APPLIED LIFE SCIENCES↗

Assessing the Continuum of Event-Based Biosurveillance Through an Operational Lens

This research follows the Updated Guidelines for Evaluating Public Health Surveillance Systems, Recommendations from the Guidelines Working Group, published by the Centers for Disease Control and Prevention nearly a decade ago. Since then, models have been developed and complex systems have evolved with a breadth of disparate data to detect or forecast chemical, biological, and radiological events that have significant impact in the One Health landscape. How the attributes identified in 2001 relate to the new range of event-based biosurveillance (EBB) technologies is unclear. This manuscript frames the continuum of EBB methods, models, and constructs through an operational lens (i.e., aspects and attributes associated with operational considerations in the development, testing, and validation of the EBB methods and models and their use in an operational environment). A 2-day subject matter expert workshop was held to scientifically identify, develop, and vet a set of attributes for the broad range of such operational considerations. Workshop participants identified and described comprehensive attributes for the characterization of EBB. The identified attributes are: (1) event, (2) readiness, (3) operational aspects, (4) geographic coverage, (5) population coverage, (6) input data, (7) output, and (8) cost. Ultimately, the analyses herein discuss the broad scope, complexity, and relevant issues germane to EBB useful in an operational environment.

59 BASIC BIOLOGICAL SCIENCES↗

Verification of Reactor Activation Modelling with Physical Characterization Data and the Impact on Long Term Assessments - 20303

Whiteshell Laboratories, located in Manitoba, Canada, provided research facilities for the Canadian nuclear industry since the early 1960's. The facility was centered on Whiteshell Reactor 1 (WR-1), an organically cooled, heavy water moderated nuclear reactor. WR-1 was safely shut down in 1985, defueled and drained, and has been in a safe Storage with Surveillance (Deferred Decommissioning) state until present day. In support of an Environmental Assessment for proposed in-situ disposal of WR-1, detailed characterization information regarding the reactor core components (calandria, calandria tubes, and pressure tubes) was necessary to provide confidence that the long-term impacts of the facility can be assessed adequately. A simplified estimate of the total activation of core components was completed in 1992 using conservative assumptions, expected reactor configuration and computer models built with WIMS-CRNL, ONEDANT and ORIGEN-S. Due to the simplification, and age of the work, there was considerable doubt that the modelled inventory estimate of the core components was sufficient to support long-term performance modeling of the planned in-situ decommissioning. Additional data would be required to provide this confidence. Several options were considered for characterizing the WR-1 core components, but it was decided to collect only a limited number of samples in an effort to validate the 1992 simplified estimate as bounding. The limited number of samples reduced risks to workers, both radiological and non-radiological, and significantly reduced the costs required to confidently define and bound the radiological inventory of activation products in the core. The results of the sampling were compared to the simplified activation estimation. There was good agreement between the modelled and sampled results, with all major contributors to total activity showing similar relative quantities. The samples were generally lower than predicted by the models, with few exceptions. Notable exceptions included Nb-94, which were higher in the sample results than the model. This was determined to be caused by the use of Niobium containing steel alloys in the stainless steel pressure tube that were not accounted for in the models. The comparison of results provided confidence that the original inventory estimates produced through the simplified model are conservative and bounding, and therefore suitable for use in the long-term assessment of in situ disposal of the WR-1 reactor. This paper provides details of the simplified computer model results, their comparison to results of the sampling, and the changes adopted in the assessment of the in-situ decommissioning of WR-1 as a result. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Noise spatial nonuniformity and the impact of statistical image reconstruction in CT myocardial perfusion imaging

Purpose: To achieve high temporal resolution in CT myocardial perfusion imaging (MPI), images are often reconstructed using filtered backprojection (FBP) algorithms from data acquired within a short-scan angular range. However, the variation in the central angle from one time frame to the next in gated short scans has been shown to create detrimental partial scan artifacts when performing quantitative MPI measurements. This study has two main purposes. (1) To demonstrate the existence of a distinct detrimental effect in short-scan FBP, i.e., the introduction of a nonuniform spatial image noise distribution; this nonuniformity can lead to unexpectedly high image noise and streaking artifacts, which may affect CT MPI quantification. (2) To demonstrate that statistical image reconstruction (SIR) algorithms can be a potential solution to address the nonuniform spatial noise distribution problem and can also lead to radiation dose reduction in the context of CT MPI. Methods: Projection datasets from a numerically simulated perfusion phantom and an in vivo animal myocardial perfusion CT scan were used in this study. In the numerical phantom, multiple realizations of Poisson noise were added to projection data at each time frame to investigate the spatial distribution of noise. Images from all datasets were reconstructed using both FBP and SIR reconstruction algorithms. To quantify the spatial distribution of noise, the mean and standard deviation were measured in several regions of interest (ROIs) and analyzed across time frames. In the in vivo study, two low-dose scans at tube currents of 25 and 50 mA were reconstructed using FBP and SIR. Quantitative perfusion metrics, namely, the normalized upslope (NUS), myocardial blood volume (MBV), and first moment transit time (FMT), were measured for two ROIs and compared to reference values obtained from a high-dose scan performed at 500 mA. Results: Images reconstructed using FBP showed a highly nonuniform spatial distribution of noise. This spatial nonuniformity led to large fluctuations in the temporal direction. In the numerical phantom study, the level of noise was shown to vary by as much as 87% within a given image, and as much as 110% between different time frames for a ROI far from isocenter. The spatially nonuniform noise pattern was shown to correlate with the source trajectory and the object structure. In contrast, images reconstructed using SIR showed a highly uniform spatial distribution of noise, leading to smaller unexpected noise fluctuations in the temporal direction when a short scan angular range was used. In the numerical phantom study, the noise varied by less than 37% within a given image, and by less than 20% between different time frames. Also, the noise standard deviation in SIR images was on average half of that of FBP images. In the in vivo studies, the deviation observed between quantitative perfusion metrics measured from low-dose scans and high-dose scans was mitigated when SIR was used instead of FBP to reconstruct images. Conclusions: (1) Images reconstructed using FBP suffered from nonuniform spatial noise levels. This nonuniformity is another manifestation of the detrimental effects caused by short-scan reconstruction in CT MPI. (2) Images reconstructed using SIR had a much lower and more uniform noise level and thus can be used as a potential solution to address the FBP nonuniformity. (3) Given the improvement in the accuracy of the perfusion metrics when using SIR, it may be desirable to use a statistical reconstruction framework to perform low-dose dynamic CT MPI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗