Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral element method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Cryo-STEM Tomography with Inpainting

Traditionally, microscopists have worked with the Nyquist-Shannon theory of sampling, which states that to be able to reconstruct the image fully it needs to be sampled at a rate of at least twice the highest spatial frequency in the image. This sampling rate assumes that the image is sampled at regular intervals and that every pixel contains information that is crucial for the image (it even assumes that noise is important). Images in general, and especially low dose S/TEM images, contain significantly less information than can be encoded by a grid of pixels (which is why image compression works). Mathematically speaking, the image data has a low dimensional or sparse representation. Through the application of compressive sensing methods [1,2,3] this representation can be found using pre-designed measurements that are usually random for implementation simplicity. These measurements and the compressive sensing reconstruction algorithms have the added benefit of reducing noise. This reconstruction approach can be extended into higher dimensions, whereby the random sampling in each 2-D image can be extended into: a sequence of tomographic projections (i.e. tilt images); a sequence of video frames (i.e. incorporating temporal resolution and dynamics); spectral resolution (i.e. energy filtering an image to see the distribution of elements); and ptychography (i.e. sampling a full diffraction image at each location in a 2-D grid across the sample). This approach has been employed experimentally for materials science samples requiring low-dose imaging [2], and can be readily applied to biological samples. Figure 1 shows the resolution possible in a complex biological system, mouse pancreatic islet beta cells [4], when tomogram slices are reconstructed using subsampling. Reducing the number of pixels (1/6 pix and 1/3*1/3) shows minimal degradation compared to the reconstructions using all pixels (all data and 1/3 tilt). Although subsampling 1/6 of the tilts (1/6 of overall dose) degrades the reconstruction to the point that the cellular structures cannot be identified. Using 1/3 of both the pixels and the tilts provides a high quality image at 1/9 the overall dose even for this most basic and rapid demonstration of the CS methods. Figure 2 demonstrates the theoretical tomogram reconstruction quality (vertical axis) as undersampling (horizontal axis) is increased; we examined subsampling pixels and tilt-angles individually and a combined approach in which both pixels and tilts are sub-sampled. Note that subsampling pixels maintains high quality reconstructions (solid lines). Using the inpainting algorithm to obtain tomograms can automatically reduce the dose applied to the system by an order of magnitude. Perhaps the best way to understand the impact is to consider that by using inpainting (and with minimal hardware changes), a sample that can normally withstand a dose of ~10 e/Å2 can potentially be imaged with an “equivalent quality” to a dose level of 103 e/Å2. To put this in perspective, this is approaching the dose level used for the most advanced images, in terms of spatial resolution, for inorganic systems. While there are issues for biological specimens beyond dose (structural complexity being the most important one), this sampling approach allows the methods that are traditionally used for materials science to be applied to biological systems [5]. References: [1] A Stevens, H Yang, L Carin et al. Microscopy 63(1), (2014), pp. 41. [2] L Kovarik, A Stevens, A Liyu et al. Appl. Phys. Lett. 109, 164102 (2016) [3] A Stevens, L Kovarik, P Abellan et al. Adv. Structural and Chemical Imaging 1(10), (2015), pp. 1. [4] MD Guay, W Czaja, MA Aronova et al. Scientific Reports 6, 27614 (2016) [5] Supported by the Chemical Imaging, Signature Discovery, and Analytics in Motion Initiatives at PNNL. PNNL is operated by Battelle Memorial Inst. for the US DOE; contract DE-AC05-76RL01830.

Stevens, Andrew↗

High-temperature Majorana fermions in magnet-superconductor hybrid systems

Magnet-superconductor hybrid (MSH) structures represent one of the most promising platforms to realize, control, and manipulate Majorana modes using scanning tunneling methods. By depositing either chains or islands of magnetic atoms on the surface of a conventional, elemental superconductor such as Pb or Re, topological superconducting phases can emerge. They feature either localized Majorana bound states at the chain ends or dispersing chiral Majorana modes at the island's boundary. However, some of these experiments have not reached the spectral resolution to clearly distinguish between topological Majorana and trivial Shiba states due to very small superconducting gap sizes and experiments performed at sub-Kelvin temperatures. Here we consider superconducting substrates with unconventional spin-singlet pairing, including high-temperature d -wave and extended s -wave superconductors. We derive topological phase diagrams and compute edge states for cylinder and island geometries and discuss their properties. Several time-reversal invariant topological superconducting phases of the Zhang-Kane-Mele type are found and discussed. Addiotnally, we review one-dimensional MSH structures and show that parameters to realize topologically nontrivial magnetic chains embedded into a larger, two-dimensional substrate differ from the purely one-dimensional case. Quite generally we find that unconventional superconducting substrates work as well as the conventional s -wave substrates to realize topological phases. In particular, iron-based pnictide and chalcogenide superconductors are the most promising class of substrates for future high-temperature MSH systems.

36 MATERIALS SCIENCE↗

Inter-digital capacitive sensor for evaluating cable jacket and insulation aging

An inter-digital capacitive (TDC) sensor has previously been used to measure dielectric properties of cable insulation polymer material when placed in direct contact with the insulation. Often cable insulation is covered by a polymer jacket. The dielectric properties of many cable jacket and insulation polymers are known to change due to thermal and radiation exposure-related damage. These dielectric properties frequently track with other measures of cable aging, such as tensile elongation-at-break and indenter modulus that have been broadly established as cable insulation polymer assessment methods. The external jacket of a cable is likely to have a different permittivity from the underlying insulation, and frequently the jacket material exhibits more severe damage than the insulation material due to environmental exposure. Because the jacket serves primarily to guard the cable during installation, as long as the underlying insulation condition is acceptable, the jacket condition is relatively unimportant in service. As part of a continuing program to develop and evaluate nondestructive examination methods that may be applied to cable condition assessment, a set of tools has been developed including (1) a parallel-plate sensor to directly measure the permittivity spectrum of flat sheet material and (2) an TDC and fixture to measure the effect of cable polymer dielectric property change on the sensor response. The TDC consists of two fork-like electrodes facing each other with the fork tines interspersed and separated by a small gap. The electrodes are printed on one side of a flexible substrate that can be conformed to the surface of a cylindrical cable, with tines parallel to the cable axis. The electrodes are connected to a broad-frequency-spectral impedance meter that senses the capacitance between the narrowly gapped electrode tines. This capacitance is known to vary as a function of the permittivity of any material in close proximity to the electrodes. By finite element modeling (FEM) and experimentation, this study investigates the effect of tine spacing and other design parameters associated with the TDC on the voltage (potential) distribution and electric field depth of penetration. The TDC measurement of an unshielded ethylene-propylene rubber (EPR)-insulated cable is shown to track with the degree of aging and quantities obtained by established methods. For jacketed cable systems, the TDC response is dominated by the jacket but, by analyzing measurements from TDC sensors with different depths-of-field penetration into the cable under test, the influence of the chlorinated polyethylene (CPE) cable jacket material degradation can be separated from an assessment of the cable insulation thereby enabling assessment of the insulation beneath/through the jacket.

Cable NDE, Interdigital Capacitance, Cable test↗

Demonstration of an AI-driven workflow for dynamic x-ray spectroscopy

X-ray absorption near edge structure (XANES) spectroscopy is a powerful technique for characterizing the chemical state and symmetry of individual elements within materials, but requires collecting data at many energy points which can be time-consuming. While adaptive sampling methods exist for efficiently collecting spectroscopic data, they often lack domain-specific knowledge about the structure of XANES spectra. Here we demonstrate a knowledge-injected Bayesian optimization approach for adaptive XANES data collection that incorporates understanding of spectral features like absorption edges and pre-edge peaks. We show this method accurately reconstructs the absorption edge of XANES spectra using only 15–20% of the measurement points typically needed for conventional sampling, while maintaining the ability to determine the x-ray energy of the sharp peak after the absorption edge with errors less than 0.03 eV, the absorption edge with errors less than 0.1 eV; and overall root-mean-square errors less than 0.005 compared to traditionally sampled spectra. Our experiments on battery materials and catalysts demonstrate the method’s effectiveness for both static and dynamic XANES measurements, improving data collection efficiency and enabling better time resolution for tracking chemical changes. This approach advances the degree of automation in XANES experiments, reducing the common errors of under- or over-sampling points near the absorption edge and enabling dynamic experiments that require high temporal resolution or limited measurement time.

Bayesian optimization↗

Determination of a brass alloy concentration composition using calibration-free laser-induced breakdown spectroscopy

Laser-induced breakdown spectroscopy (LIBS) is a technique that can provide qualitative and quantitative measurements of the characteristics of irradiated metals. In the present work, we have calculated the parameters of the plasma produced from a brass alloy sample under the action of a pulsed Nd: YAG laser operating at 1064 nm. The emission lines of copper atoms (Cu I), zinc atoms (Zn I), and lead atoms (Pb I), which are elements of a brass alloy composition, were used to investigate the parameters of the brass plasma. The spectral profiles of Cu, Zn, and Pb lines have been used to extract the electron temperature and density of the brass alloy plasma. The characteristics of Cu, Zn, and Pb were determined quantatively by the calibration-free LIBS (CF-LIBS) method considering for accurate analysis that the laser-induced ablated plasma is optically thin in local thermodynamic equilibrium conditions and the plasma ablation is stoichiometric. The Boltzmann plot method was used to evaluate the plasma temperature, and the Stark broadened profiles were used to determine the electron density. An algorithm based on the experimentally measured values of the intensity of spectral lines and the basic laws of plasma physics was developed for the determination of Cu, Zn, and Pb concentrations in the brass sample. The concentrations C{sub CF-LIBS} calculated by CF-LIBS and the certified concentrations C{sub certified} were very close.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determining Stellar Elemental Abundances from DESI Spectra with the Data-driven Payne

Abstract Stellar abundances for a large number of stars provide key information for the study of Galactic formation history. Large spectroscopic surveys such as the Dark Energy Spectroscopic Instrument (DESI) and LAMOST take median-to-low-resolution (R≲ 5000) spectra in the full optical wavelength range for millions of stars. However, the line-blending effect in these spectra causes great challenges for elemental abundance determination. Here we employDD-Payne, a data-driven method regularized by differential spectra from stellar physical models, to the DESI early data release spectra for stellar abundance determination. Our implementation delivers 15 labels, including effective temperatureT eff , surface gravity log g , microturbulence velocityv mic , and the abundances for 12 individual elements, namely C, N, O, Mg, Al, Si, Ca, Ti, Cr, Mn, Fe, and Ni. Given a spectral signal-to-noise ratio of 100 per pixel, the internal precisions of the label estimates are about 20 K forT eff , 0.05 dex for log g , and 0.05 dex for most elemental abundances. These results agree with the theoretical limits from the Crámer–Rao bound calculation within a factor of 2. The majority of the accreted halo stars contributed by the Gaia–Enceladus–Sausage are discernible from the disk and in situ halo populations in the resultant [Mg/Fe]–[Fe/H] and [Al/Fe]–[Fe/H] abundance spaces. We also provide distance and orbital parameters for the sample stars, which spread over a distance out to ∼100 kpc. The DESI sample has a significantly higher fraction of distant (or metal-poor) stars than the other existing spectroscopic surveys, making it a powerful data set for studying the Galactic outskirts. The catalog is publicly available.

Astronomy & Astrophysics↗

Coupled atmosphere/canopy model for remote sensing of plant reflectance features

Solar radiative transfer through a coupled system of atmosphere and plant canopy is modeled as a multiple-scattering problem through a layered medium of random scatterers. The radiative transfer equation is solved by the discrete-ordinates finite-element method. Analytic expressions are derived that allow the calculation of scattering and absorption cross sections for any plant canopy layer form measurable biophysical parameters such as the leaf area index, leaf angle distribution, and individual leaf reflectance and transmittance data. An expression for a canopy scattering phase function is also given. Computational results are in good agreement with spectral reflectance measurements directly above a soybean canopy, and the concept of greenness- and brightness-transforms of Landsat MSS data is reconfirmed with the computed results. A sensitivity analysis with the coupled atmosphere/canopy model quantifies how satellite-sensed spectral radiances are affected by increased atmospheric aerosols, by varying leaf area index, by anisotropic leaf scattering, and by non-Lambertian soil boundary conditions. Possible extensions to a 2-D model are also discussed.

Gerstl, S. A.↗

Terahertz imaging devices and systems, and related methods, for detection of materials

Terahertz imaging devices may comprise a focal plane array including a substrate and a plurality of resonance elements. The plurality of resonance elements may comprise a conductive material coupled to the substrate. Each resonance element of the plurality of resonance elements may be configured to resonate and produce an output signal responsive to incident radiation having a frequency between about a 0.1 THz and 4 THz range. A method of detecting a hazardous material may comprise receiving incident radiation by a focal plane array having a plurality of discrete pixels including a resonance element configured to absorb the incident radiation at a resonant frequency in the THz, generating an output signal from each of the discrete pixels, and determining a presence of a hazardous material by interpreting spectral information from the output signal.

36 MATERIALS SCIENCE↗

Localized Radial Basis Functions for Radiation Transport in Slab Geometry

Meshing the spatial domain for the neutron transport equation can be computationally expensive and labor-intensive. Mesh-free methods, such as radial basis function (RBF) approximations, may alleviate these concerns by using a pointwise solution of the transport equation instead of the standard volume-integrated solution using cells or elements. This allows for the use of any geometric description that can provide the material at solution points and the boundary normal directions for boundary points. RBFs give spectral convergence when used to solve differential equations, but only if they are infinitely smooth. This occurs when the RBFs are effectively flat, creating an ill-conditioned, dense system of equations. One simple way to alleviate this issue is to use localized RBFs. Global RBFs have been applied previously to the monoenergetic radiative transport equation in X-Y geometry using source iteration. In this summary, localized RBFs are applied to the multigroup neutron transport equation in slab geometry using Krylov iteration. The results show agreement with benchmark solutions, provided the coefficients for the RBF basis are properly chosen. (authors)

97 MATHEMATICS AND COMPUTING↗

APOGEE Data and Spectral Analysis from SDSS Data Release 16: Seven Years of Observations Including First Results from APOGEE-South

The spectral analysis and data products in Data Release 16 (DR16; 2019 December) from the high-resolution near-infrared Apache Point Observatory Galactic Evolution Experiment (APOGEE)-2/Sloan Digital Sky Survey (SDSS)-IV survey are described. Compared to the previous APOGEE data release (DR14; 2017 July), APOGEE DR16 includes about 200,000 new stellar spectra, of which 100,000 are from a new southern APOGEE instrument mounted on the 2.5 m du Pont telescope at Las Campanas Observatory in Chile. DR16 includes all data taken up to 2018 August, including data released in previous data releases. All of the data have been re-reduced and re-analyzed using the latest pipelines, resulting in a total of 473,307 spectra of 437,445 stars. Changes to the analysis methods for this release include, but are not limited to, the use of MARCS model atmospheres for calculation of the entire main grid of synthetic spectra used in the analysis, a new method for filling “holes” in the grids due to unconverged model atmospheres, and a new scheme for continuum normalization. Abundances of the neutron-capture element Ce are included for the first time. A new scheme for estimating uncertainties of the derived quantities using stars with multiple observations has been applied, and calibrated values of surface gravities for dwarf stars are now supplied. Compared to DR14, the radial velocities derived for this release more closely match those in the Gaia DR2 database, and a clear improvement in the spectral analysis of the coolest giants can be seen. The reduced spectra as well as the result of the analysis can be downloaded using links provided on the SDSS DR16 web page.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of Low-Complexity Spectrally Selective One-Dimensional Mirrors for Photovoltaic Thermal Management: Preprint

Operation at elevated temperatures is detrimental to the performance of crystalline Si solar modules. One method of reducing module operating temperature is selective reflection of sub-band gap photons, which can otherwise only be absorbed parasitically. We numerically optimize the design of a series of multilayer photonic mirrors based on real materials using a previously developed optimization routine. Combined ray tracing and finite element simulations reveal the ability of each mirror to increase energy yield and decrease operating temperature. The best design outperforms a conventional glass antireflection coating, contains only nine layers, and maintains performance regardless of geographic location.

14 SOLAR ENERGY↗

Preparation and photoluminescence properties of RE:Na{sub 3}La{sub 9}O{sub 3}(BO{sub 3}){sub 8} (RE=Er, Yb) crystals

Using Na{sub 2}CO{sub 3}-H{sub 3}BO{sub 3}-NaF as fluxes, transparent RE:Na{sub 3}La{sub 9}O{sub 3}(BO{sub 3}){sub 8} (abbr. RE:NLBO, RE=Er, Yb) crystals have been grown by the top seed solution growth (TSSG) method. The X-ray powder diffraction analysis shows that the RE:NLBO crystals have the same structure with NLBO. The element contents were determined by molar to be 0.64% Er{sup 3+} in Er:NLBO, 2.70% Yb{sup 3+} in Yb:NLBO, respectively. The polarized absorption spectra of RE:NLBO have been measured at room temperature and show that both Er:NLBO and Yb:NLBO have a strong absorption bands near 980 nm with wide FWHM (Full Wave at Half Maximum) (21 nm for Er:NLBO and 25 nm for Yb:NLBO). Fluorescence spectra have been recorded. Yb:NLBO has the emission peaks at 985 nm, 1028 nm and 1079 nm and the emission peak of Er:NLBO is at 1536 nm. Spectral parameters have been calculated by the Judd-Ofelt theory for Er:NLBO and the reciprocity method for Yb:NLBO, respectively. The calculated values show that Er:NLBO is a candidate of 1.55 {mu}m laser crystals and Yb:NLBO is a candidate for self-frequency doubling crystal. - Graphical abstract: Fluorescence spectra show the emission peaks at 985, 1028 and 1079 nm of Yb:NLBO and at 1536 nm of Er:NLBO.

36 MATERIALS SCIENCE↗

In situ Analysis of Fireworks Using Laser-Induced Breakdown Spectroscopy and Chemometrics

Different types of fireworks are analyzed using the laser-induced breakdown spectroscopy (LIBS) technique. The system employed for spectral acquisition consists of a Nd:YAG laser (532 nm, FWHM = 4 ns) and an Andor Mechelle ME 5000 echelle spectrometer. The presence of Ba, Ca, Mg, Fe, Na, Sr, Si, and Al is identified in the LIBS spectra of different fireworks. These elements can mix easily into the surroundings and thus pollute the environment. In combination with LIBS, multivariate statistical methods, such as principal component analysis and partial least square discriminant analysis, are employed for qualitative classification, regression, and prediction purposes. These methods show good applicability for the classification and prediction of a large data set.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Excitation of a Parallel Plate Waveguide by an Array of Rectangular Waveguides

This work addresses the problem of excitation of a parallel plate waveguide by an array of rectangular waveguides that arises in applications such as the continuous transverse stub (CTS) antenna and dual-polarized parabolic cylindrical reflector antennas excited by a scanning line source. In order to design the junction region between the parallel plate waveguide and the linear array of rectangular waveguides, waveguide sizes have to be chosen so that the input match is adequate for the range of scan angles for both polarizations. Electromagnetic wave scattered by the junction of a parallel plate waveguide by an array of rectangular waveguides is analyzed by formulating coupled integral equations for the aperture electric field at the junction. The integral equations are solved by the method of moments. In order to make the computational process efficient and accurate, the method of weighted averaging was used to evaluate rapidly oscillating integrals encountered in the moment matrix. In addition, the real axis spectral integral is evaluated in a deformed contour for speed and accuracy. The MoM results for a large finite array have been validated by comparing its reflection coefficients with corresponding results for an infinite array generated by the commercial finite element code, HFSS. Once the aperture electric field is determined by MoM, the input reflection coefficients at each waveguide port, and coupling for each polarization over the range of useful scan angles, are easily obtained. Results for the input impedance and coupling characteristics for both the vertical and horizontal polarizations are presented over a range of scan angles. It is shown that the scan range is limited to about 35 for both polarizations and therefore the optimum waveguide is a square of size equal to about 0.62 free space wavelength.

Rengarajan, Sembiam↗

System and method for curved light sheet projection during two-photon polymerization

A laser-based manufacturing system is disclosed for fabricating non-planar three-dimensional layers. The system may have a laser for producing a laser beam with a plurality of optical wavelengths. An optically dispersive element may be used for receiving the laser beam and splitting the beam into a plurality of distinct beam components, wherein each beam component has spatially separated optical spectral components. A phase mask may be used which is configured to receive at least one of the beam components emerging from the dispersive element and to create a modified beam. One or more focusing elements may then be used to receive the modified beam emerging from the phase mask and to focus the modified beam into a non-planar light sheet for use in fabricating a part.

Saha, Sourabh Kumar↗

Abbreviated Technical Report: Experimentally Interrogating Detonation Chemistry on Sub-Nanosecond to Nanosecond Timescales

Direct experimental measurement of chemical reactions during high explosive detonation remains challenging. Theory and modeling have long preceded experiment in the fundamental physical and chemical kinetic properties of detonation, and experimentation at the relevant timescales are needed to both validate models and provide fundamental understanding of detonation. In this LDRD-ER project, two approaches, x-ray diffraction and core-level x-ray Raman, were developed and used to further experimental capabilities to address this gap. We further developed dynamic x-ray diffraction to directly detect nanodiamond formation during detonation, providing experimental data towards resolving longstanding controversy in the scientific literature, and although the full kinetics have not yet been fully mapped, diamond diffraction appears on the same timescales as detonation soot formation. In the second research thrust, we have developed core-level x-ray Raman for use with high explosives. This technique provides information analogous to x-ray absorption spectroscopy and electron energy loss spectroscopy, but uses inelastic scattering of hard x-rays that can interrogate chemistry around light elements much deeper into the material. The low cross section and requisite high solid angle collection have hindered its use for ultra-fast spectroscopy. We developed and tested a high-q spectrometer which will substantially increase cross section and signal-to-noise, showing this method will also not dramatically alter, compared to x-ray absorption, the most discriminating spectral features of C, N, and O from various high explosives and expected detonation products. We have also used x-ray Raman combined with OCEAN electronic structure calculations to explore dynamic photodegradation mechanisms in PETN and CL-20 explosives. This provides a pathway towards implementing capability to dynamically explore chemistry at an x-ray free electron laser.

36 MATERIALS SCIENCE↗

Time-dependent jet flow and noise computations

Methods for computing jet turbulence noise based on the time-dependent solution of Lighthill's (1952) differential equation are demonstrated. A key element in this approach is a flow code for solving the time-dependent Navier-Stokes equations at relatively high Reynolds numbers. Jet flow results at Re = 10,000 are presented here. This code combines a computationally efficient spectral element technique and a new self-consistent turbulence subgrid model to supply values for Lighthill's turbulence noise source tensor.

Berman, C. H.↗

Signal digitizing system and method based on amplitude-to-time optical mapping

A signal digitizing system and method based on analog-to-time optical mapping, optically maps amplitude information of an analog signal of interest first into wavelength information using an amplitude tunable filter (ATF) to impress spectral changes induced by the amplitude of the analog signal onto a carrier signal, i.e. a train of optical pulses, and next from wavelength information to temporal information using a dispersive element so that temporal information representing the amplitude information is encoded in the time domain in the carrier signal. Optical-to-electrical conversion of the optical pulses into voltage waveforms and subsequently digitizing the voltage waveforms into a digital image enables the temporal information to be resolved and quantized in the time domain. The digital image may them be digital signal processed to digitally reconstruct the analog signal based on the temporal information with high fidelity.

47 OTHER INSTRUMENTATION↗