Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

A Near-Infrared Mapping Spectrometer for investigation of Jupiter and its satellites

The Near-Infrared-Mapping Spectrometer (NIMS) is one of the science instruments in the Galileo mission, which will explore Jupiter and its satellites in the mid-1990's. The NIMS experiment will map geological units on the surfaces of the Jovian satellites and characterize their mineral content; and, for the atmosphere of Jupiter, investigate cloud properties and the spatial and temporal variability of molecular abundances. The optics are gold-coated reflective and consist of a telescope and a grating spectrometer. The balance of the instrument includes a 17-detector (silicon and indium antimonide) focal plane array, a tuning fork chopper, microprocessor-controlled electronics, and a passive radiative cooler. A wobbling secondary mirror in the telescope provides 20 pixels in one dimension of spatial scanning in a pushbroom mode with 0.5 mr x 0.5 mr instantaneous field of view. The spectral range is 0.7-5.2 microns; resolution is 0.025 micron. NIMS is the first infrared experiment to combine both spatial and spectral mapping capability in one instrument.

Aptaker, Irving M.↗

Visible and infrared mapping spectrometer (VIMS) - A facility instrument for planetary missions

A second-generation visible and IR mapping spectrometer (VIMS), selected for both the Mars Observer and Comet Rendezvous Asteroid Flyby (CRAF) missions, is described. VIMS is a scanning spectrometer with a focal plane consisting of linear arrays of visible and IR detectors, cooled by a radiative cooler. It is noted that a wide-angle scan using a full-aperture scan mirror was implemented for the Mars Observer; a narrow-angle scan using a scanning secondary mirror within a Cassegrain foreoptic was achieved for the CRAF mission.

Wellman, John B.↗

Feasibility of an uncooled imaging spectrometer for the exploration of the solar system

A state-of-the-art imaging spectrometer concept is presented for visible-midwavelength IR spectral region studies of the solar system that obviates the until-now essential use of cryogenic cooling. This uncooled imaging spectrometer configuration is evaluated in view of the prospective environments of the instrument in various spacecraft orbits, as well as in light of various available photodetector materials and sensor focal plane array configurations.

Liaw, H. M.↗

Cryogenic Fourier spectrometer for measuring trace species in the lower stratosphere

A cryogenic Fourier transform spectrometer has been built to measure thermal emission of the earth's limb from a balloon-borne platform. Liquid nitrogen cooling of the spectrometer and liquid helium cooling of the detectors has provided sufficient sensitivity to detect, at 5-15 microns, fifteen molecular species relevant to stratospheric ozone chemistry. The spectral resolution achieved, 0.022/cm, is the best yet attained for emission mode data at these wavelengths. The philosophy behind the design of the optical and electronic systems is presented, followed by an analysis of the performance achieved during balloon flight.

Brasunas, John C.↗

In-flight radiometric calibration of the airborne visible/infrared imaging spectrometer (AVIRIS)

A reflectance-based method was used to provide an analysis of the in-flight radiometric performance of AVIRIS. Field spectral reflectance measurements of the surface and extinction measurements of the atmosphere using solar radiation were used as input to atmospheric radiative transfer calculations. Five separate codes were used in the analysis. Four include multiple scattering, and the computed radiances from these for flight conditions were in good agreement. Code-generated radiances were compared with AVIRIS-predicted radiances based on two laboratory calibrations for a uniform highly reflecting natural dry lake target. For one spectrometer, the pre- and post-season calibration factors were found to give identical results, and to be in agreement with the atmospheric models that include multiple scattering. Results for the other spectrometers were widely at variance with the models no matter which calibration factors were used. Potential causes of these discrepancies are discussed.

Conel, James E.↗

Evaluation of the airborne visible-infrared imaging spectrometer for mapping subtle lithological variation

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), flown aboard the NASA ER-2 aircraft in 1987 and 1989, used four linear arrays and four individual spectrometers to collect data simultaneously from the 224 bands in a scanned 614 pixel-wide swath perpendicular to the aircraft direction. The research had two goals. One was to evaluate the AVIRIS data. The other was to look at the subtle lithological variation at the two test sites to develop a better understanding of the regional geology and surficial processes. The geometric characteristics of the data, adequacy of the spatial resolution, and adequacy of the spectral sampling interval are evaluated. Geologic differences at the test sites were mapped. They included lithological variation caused by primary sedimentary layering, facies variation, and weathering; and subtle mineralogical differences caused by hydrothermal alterations of igneous and sedimentary rocks. The investigation used laboratory, field, and aircraft spectral measurements; known properties of geological materials; digital image processing and spectrum processing techniques; and field geologic data to evaluate the selected characteristics of the AVIRIS data.

Kruse, Fred A.↗

AFGL ten micron mosaic array spectrometer: Recent results

Recent measurements were made with a novel mosaic array prism spectrometer on long period variable stars of carbon and oxygen-rich atmospheres. These stars have generally large IR excesses and show strong SiC and silicate emission features, respectively. A comparison is provided by published spectra obtained with the IRAS Low Resolution Spectrometer. Emission feature equivalent widths are independent of the absolute photometric level of the spectra and provide information on the relative variation of the feature and continuum fluxes between the epochs of the space and groundbased observations.

Levan, Paul D.↗

High resolution infrared spectroscopy of planetary molecules using diode lasers and Fourier transform spectrometers

Modern observations of infrared molecular lines in planets are performed at spectral resolutions which are as high as those available in the laboratory. Analysis of such data requires laboratory measurements at the highest possible resolution, which also yield accurate line positions and intensities. For planetary purposes the spectrometer must be coupled to sample cells which can be reduced in temperature and varied in pressure. An approach which produces the full range of required molecular line parameters uses a combination of tunable diode lasers and Fourier transform spectrometers (FTS). The FTS provides board spectral coverage and good calibration accuracy, while the diode laser can be used to study those regions which are not resolved by the FTS.

Jennings, Donald E.↗

High accuracy motor controller for positioning optical filters in the CLAES Spectrometer

The Etalon Drive Motor (EDM), a precision etalon control system designed for accurate positioning of etalon filters in the IR spectrometer of the Cryogenic Limb Array Etalon Spectrometer (CLAES) experiment is described. The EDM includes a brushless dc torque motor, which has an infinite resolution for setting an etalon filter to any desired angle, a four-filter etalon wheel, and an electromechanical resolver for angle information. An 18-bit control loop provides high accuracy, resolution, and stability. Dynamic computer interaction allows the user to optimize the step response. A block diagram of the motor controller is presented along with a schematic of the digital/analog converter circuit.

Thatcher, John B.↗

Decision net, directed graph, and neural net processing of imaging spectrometer data

A decision-net solution involving a novel hierarchical classifier and a set of multiple directed graphs, as well as a neural-net solution, are respectively presented for large-class problem and mixture problem treatments of imaging spectrometer data. The clustering method for hierarchical classifier design, when used with multiple directed graphs, yields an efficient decision net. New directed-graph rules for reducing local maxima as well as the number of perturbations required, and the new starting-node rules for extending the reachability and reducing the search time of the graphs, are noted to yield superior results, as indicated by an illustrative 500-class imaging spectrometer problem.

Casasent, David↗

Mineral mapping at Cuprite, Nevada with a 63-channel imaging spectrometer

Geophysical and Environmental Research Imaging Spectrometer (GERIS) 63-channel scanner data covering the spectral region 0.4 to 2.5 microns were analyzed for the Cuprite mining district, Esmeralda and Nye Counties, Nevada. Individual and spatially averaged spectra extracted from the GERIS data were used to identify the minerals alunite, kaolinite, buddingtonite, and hematite by their spectral characteristics. The images were classified in the spectral domain to produce color-coded image maps of mineral distribution that clearly show the zoned nature of the hydrothermal system. Comparison of the thematic mineral maps with existing geologic and alteration maps demonstrates the utility of imaging spectrometers for producing detailed maps for mineral exploration.

Kruse, F. A.↗

Comparison of backgrounds in OSO-7 and SMM spectrometers and short-term activation in SMM

The backgrounds in the OSO-7 Gamma-Ray Monitor and the Solar Maximum Mission Gamma-Ray Spectrometer are compared. After scaling to the same volume, the background spectra agree to within 30 percent. This shows that analyses which successfully describe the background in one detector can be applied to similar detectors of different sizes and on different platforms. The background produced in the SMM spectrometer by a single trapped-radiation belt passage is also studied. This background is found to be dominated by a positron-annihilation line and a continuum spectrum with a high energy cutoff at 5 MeV.

Dunphy, P. P.↗

Tunable diode laser IR spectrometer for in situ measurements of the gas phase composition and particle size distribution of Titan's atmosphere

A new instrument, the Probe Infrared Laser Spectrometer (PIRLS), is described for in situ sensing of the gas composition and particle size distribution of Titan's atmosphere on the NASA/ESA Cassini mission. For gas composition measurements, several narrow-band (0.0001/cm) tunable lead-salt diode lasers operating near 80 K at selected mid-IR wavelengths are directed over a path length defined by a small reflector extending over the edge of the probe spacecraft platform; volume mixing ratios of 10 to the -9th should be measurable for several species of interest. A cloud-particle-size spectrometer using a diode laser source at 780 nm shares the optical path and deployed reflector; a combination of imaging and light scattering techniques is used to determine sizes of haze and cloud particles and their number density as a function of altitude.

Webster, Christopher R.↗

An image recorded by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

The airborne visible/infrared imaging spectrometer (AVIRIS) is described, and an example of a false-color image recorded by this device is provided. The AVIRIS is capable of sensing in 209 visible and near-infrared wavebands with an 11km swath and a 20m spatial resolution. Evaluation flights for AVIRIS were made at an altitude of approximately 20km x 10.2km of low-lying and relatively flat irrigated land near Yuba City and Sacramento, California. Raw data were converted from digital numbers to radiance and radiometrically corrected at the NASA Jet Propulsion Laboratory. Notch filtering in the frequency domain of the image was used to remove periodic noise. The illustration of both spatial and spectral properties on the false-color image are explained. AVIRIS is designed to be flown in an ER-2 aircraft and will serve as a test-bed sensor for the High-Resolution Imaging Spectrometer (HIRIS) planned for the Earth Observing System.

Curran, Paul J.↗

Constant-dispersion grism spectrometer for channeled spectra

A new spectrometer design is presented in which the angular dispersion with respect to wave number is nearly constant. The spectrometer is a type of grism, a series combination of grating and prism, in which the constant parts of the dispersion terms add to one another but the slopes of the dispersions tend to cancel one another. A systematic method is presented for optimizing the grating and prism parameters. A cross-dispersion technique is presented, eliminating overlapping grating orders. A design example is given for the visible region from 0.45 to 0.80 micron with essentially constant wave-number dispersion and a peak transmission of approximately 95 percent. This grism is well suited for measuring channeled spectra as generated by an optical stellar interferometer.

Traub, Wesley A.↗

Calibration of the Berkeley EUV Airglow Rocket Spectrometer

The Berkeley Extreme-ultraviolet Airglow Rocket Spectrometer (BEARS), a multiinstrument sounding rocket payload, made comprehensive measurements of the earth's dayglow. The primary instruments consisted of two near-normal Rowland mount spectrometers: one channel to measure several atomic oxygen features at high spectral resolution (about 1.5 A) in the band passes 980-1040 and 1300-1360 A, and the other to measure EUV dayglow and the solar EUV simultaneously in a much broader bandpass (250-1150 A) at moderate resolution (about 10 A). The payload also included a hydrogen Lyman-alpha photometer to monitor the solar irradiance and goecoronal emissions. The instrument was calibrated at the EUV calibration facility at the University of California at Berkeley, and was subsequently launched successfully on September 30, 1988 aboard a four-stage experimental sounding rocket, Black Brant XII flight 12.041 WT. The calibration procedure and resulting data are presented.

Cotton, Daniel M.↗

The rotating spectrometer: New biotechnology for cell separations

An instrument for biochemical studies, called the rotating spectrometer, separates previously inseparable cell cultures. The rotating spectrometer is intended for use in pharmacological studies which require fractional splitting of heterogeneous cell cultures based on cell morphology and swimming behavior. As a method to separate and concentrate cells in free solution, the rotating method requires active organism participation and can effectively split the large class of organisms known to form spontaneous patterns. Examples include the biochemical star, an organism called Tetrahymena pyriformis. Following focusing in a rotated frame, the separation is accomplished using different radial dependencies of concentrated algal and protozoan species. The focusing itself appears as concentric rings and arises from the coupling between swimming direction and Coriolis forces. A dense cut is taken at varying radii and extraction is replenished at an inlet. Unlike standard separation and concentrating techniques such as filtration or centrifugation, the instrument is able to separate motile from immotile fractions. For a single pass, typical split efficiencies can reach 200 to 300 percent compared to the inlet concentration.

Noever, David A.↗

AI mass spectrometers for space shuttle health monitoring

The facility Hazardous Gas Detection System (HGDS) at Kennedy Space Center (KSC) is a mass spectrometer based gas analyzer. Two instruments make up the HGDS, which is installed in a prime/backup arrangement, with the option of using both analyzers on the same sample line, or on two different lines simultaneously. It is used for monitoring the Shuttle during fuel loading, countdown, and drainback, if necessary. The use of complex instruments, operated over many shifts, has caused problems in tracking the status of the ground support equipment (GSE) and the vehicle. A requirement for overall system reliability has been a major force in the development of Shuttle GSE, and is the ultimate driver in the choice to pursue artificial intelligence (AI) techniques for Shuttle and Advanced Launch System (ALS) mass spectrometer systems. Shuttle applications of AI are detailed.

Adams, F. W.↗