Search NASA⌕ Search

SEARCH · Search NASA

Results for “System specification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Target Accuracy Assessment for an ADS Design

Nuclear data uncertainties and their impact on a very wide range of reactor systems, including their associated fuel cycles, have to be assessed in order to consolidate preliminary design studies for new innovative systems. One specific class of systems is the so-called “dedicated waste transmuters”, that are fast neutron systems (critical or sub-critical, i.e. ADS), loaded with a Minor Actinide (MA) dominated fuel and potentially uranium-free. The availability of very general tools for sensitivity and uncertainty analysis together with new variance-covariance matrix data, produced in a joint effort under the auspices of the OECD-NEA by the world leading nuclear data evaluation groups, makes that endeavor particularly significant. In this report major results of interest for dedicated ADS are discussed and the most important fields and data types are pointed out, where priority improvements are required.

99 GENERAL AND MISCELLANEOUS↗

Generic solar photovoltaic system dynamic simulation model specification

This document is intended to serve as a specification for generic solar photovoltaic (PV) system positive-sequence dynamic models to be implemented by software developers and approved by the WECC MVWG for use in bulk system dynamic simulations in accordance with NERC MOD standards. Two specific dynamic models are included in the scope of this document. The first, a Central Station PV System model, is intended to capture the most important dynamic characteristics of large scale (> 10 MW) PV systems with a central Point of Interconnection (POI) at the transmission level. The second, a Distributed PV System model, is intended to represent an aggregation of smaller, distribution-connected systems that comprise a portion of a composite load that might be modeled at a transmission load bus.

14 SOLAR ENERGY↗

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects [Slides]

Develop a Design Basis Document / Owner’s Technical Specification for nitrate salt systems in commercial parabolic trough and central receiver projects. A Design Basis Document is to a project what a heat exchanger specification is to a heat exchanger, Extensive commercial experience in salt equipment and system design, much of it gained through mistakes and associated expenses. Distill the successful experience with nitrate salt systems from as many commercial projects as possible. Starting from 7 historical Design Basis Documents, compile a consensus description of commercial equipment and system designs.

14 SOLAR ENERGY↗

Model predictive control for voltage restoration in microgrids using temporal logic specifications

Power system operation will encounter numerous voltage variabilities as the proliferation of renewable energy continues. Real-time monitoring and communication technologies can potentially improve voltage stability by enabling the rapid detection of voltage deviations and the implementation of corrective actions. These corrective actions will only be effective in restoring stability if they are chosen in a timely and scalable manner. This paper considers the problem of power systems’ load voltage control in order to simultaneously address both magnitude and time voltage specifications. In order to comply with grid codes and avoid unnecessary relay protection actions, a model predictive control (MPC)-based control strategy employing temporal logic specifications (TLSs) is proposed. The TLSs strategy is introduced as a formalism to control the voltage variation at a critical load bus against operational bounds over time. The control objective is to schedule optimal control input signals from the available supportive energy storage systems, which provide reactive power injections, leading to satisfying the specified finite-time restoration described by the TLSs with minimal control efforts. The simulation results display that the TLSs strategy for power systems’ voltage control synthesis is extremely significant.

24 POWER TRANSMISSION AND DISTRIBUTION↗

First in-core simultaneous measurements of nuclear heating and thermal neutron flux obtained with the innovative mobile calorimeter CALMOS inside the OSIRIS reactor

Nuclear heating inside a MTR reactor has to be known in order to design and to run irradiation experiments which have to fulfill target temperature constraints. This measurement is usually carried out by calorimetry. The innovative calorimetric system, CALMOS, has been studied and built in 2011 for the 70 MWth OSIRIS reactor operated by CEA. Thanks to a new type of calorimetric probe, associated to a specific displacement system, it provides measurements along the fissile height and above the core. This development required preliminary modelling and irradiation of mock-ups of the calorimetric probe in the ex-core area, where nuclear heating rate does not exceed 2 W.g{sup -1}. The calorimeter working modes, the different measurement procedures allowed with such a new probe, the main modeling and experimental results and expected advantages of this new technique have been already presented. However, these first in-core measurements were not performed beyond 6 W.g{sup -1}, due to an inside temperature limitation imposed by a safety authority requirement. In this paper, we present the first in-core simultaneous measurements of nuclear heating and conventional thermal neutron flux obtained by the CALMOS device at the 70 MW nominal reactor power. For the first time, this experimental system was operated in nominal in-core conditions, with nominal neutron flux up to 2.7 10{sup 14} n.cm{sup -2}.s{sup -1} and nuclear heating up to 12 W.g{sup -1}. A comprehensive measurement campaign carried out from 2013 to 2015 inside all accessible irradiation locations of the core, allowed to qualify definitively this new device, not only in terms of measurement ability but also in terms of reliability. After a brief reminder of the calorimetric cell configuration and displacement system specificities, first nuclear heating distributions at nominal power are presented and discussed. In order to reinforce the heating evaluation, a systematic comparison is made between results obtained by different methods, the probe calibration coefficient and the zero method. Thermal neutron flux evaluation from the SPND signal processing required a specific TRIPOLI-4 Monte Carlo calculation which has been performed with the precise CALMOS cell geometry. In addition, the Finite Element model for temperatures map prediction inside the calorimetric cell has been upgraded with the recent experimental data obtained up to 12 W.g{sup -1}. The Kc coefficient, taking into account nonlinearities with regard to the calibration, has been reevaluated so as to make relevant measurements up to the nominal reactor power. Finally, the experience feedback acquired until now with this first CALMOS version led us to improvement perspectives. A second device is currently under manufacturing and main technical options chosen for this second version are presented. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance Specification for Standardized Transportation, Aging, and Disposal Canister Systems (Rev.2)

This performance specification document addresses use of a standardized transportation, aging, and disposal (STAD) canister system in the spent nuclear fuel (SNF) waste management system. This document was developed to support STAD canister system studies and potential research, development, and demonstration activities. Requirements in this specification may evolve with time based on results from analyses, experiments, design studies, system evaluations and demonstrations, as well as other factors. A STAD canister system consists of a canister, together with a storage or aging overpack/module/vault, a shielded transfer cask (STC), a site transporter, a transportation overpack, and a transportation skid. Three sizes of circular cross section STAD canister variants are specified in this document. The small STAD canister capacity is four pressurized water reactor (PWR) or nine boiling water reactor (BWR) SNF assemblies. The medium STAD canister capacity is 12 PWR or 32 BWR SNF assemblies. The large STAD canister capacity is 21 PWR or 44 BWR SNF assemblies. Using standardized canisters for SNF facilitates the interface between storage at an independent spent fuel storage installation (ISFSI) or a DOEowned interim storage facility (ISF), transportation between facilities, and disposal at a repository. Multiple STAD canisters may be stored in a single storage overpack and/or a single transportation overpack. The US Nuclear Regulatory Commission (NRC) requirements currently used for storage and transportation are adopted for the STAD canister system. Approved approaches (guidance) in NRC storage and transportation documents are also adopted as requirements for the STAD canister system to facilitate obtaining NRC Certificates of Compliance (CoCs) for STAD canister systems. Performance specifications in this document are also informed by STAD canister disposability in various geologic media and consideration of ISF (and geologic repository) handling facility design, operations, and licensing requirements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pulsed High Power Calibration System

This specification defines the minimum requirements for the manufacture, performance, and acceptance of a 10 kA Pulsed High Power Calibration System capable of output pulsed current with durations ranging from 1us to 100 us and currents ranging from 0.1 Amperes to 10,000 Amperes.

42 ENGINEERING↗

Criticality calculation of non-ordinary systems

The specific features of calculation of the effective multiplication factor using the Monte Carlo method for weakly coupled and non-asymptotic multiplying systems are discussed. Particular examples are considered and practical recommendations on detection and Monte Carlo calculation of systems typical in numerical substantiation of nuclear safety for VVER fuel management problems are given. In particular, the problems of the choice of parameters for the batch mode and the method for normalization of the neutron batch, as well as finding and interpretation of the eigenvalue spectrum for the integral fission matrix, are discussed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mitigation of Motor Stalling and FIDVR via Energy Storage Systems with Temporal Logic Specifications

The fault-induced delayed voltage recovery (FIDVR) phenomenon has been very common from the distribution system through the transmission system. It causes a delay on recovering significantly depressed local voltage after the fault is cleared, and it can also lead to more widespread cascading system failures. Mitigating this event with current control approaches is challenging and becoming a crucial issue. Here, a model predictive control-based strategy employing signal temporal logic specifications is proposed to help mitigate FIDVR. To this end, it investigates and extends a dynamic performance model allowing analytic insights into the system-wide impact of motor stalling and FIDVR. The proposed controller provides richer descriptions of voltage specifications addressing both magnitude and time simultaneously. We consider different control specifications with reactive power support from energy storage systems to prevent the voltage during/after the fault from dropping too low, and reduce the delay time of voltage recovery. The simulation results conducted with the IEEE 57 bus test network validate the proposed method and demonstrate the effectiveness of the mitigation strategy on FIDVR.

25 ENERGY STORAGE↗

Aromatase inhibition by synthetic lactones and flavonoids in human placental microsomes and breast fibroblasts - A comparative study

Interference of exogenous chemicals with the aromatase enzyme can be useful as a tool to identify chemicals that could act either chemopreventive for hormone-dependent cancer or adverse endocrine disruptive. Aromatase is the key enzyme in the biosynthesis of steroids, as it converts androgens to estrogens. Certain flavonoids, plant derived chemicals, are known catalytic aromatase inhibitors. Various systems are in use to test aromatase inhibitory properties of compounds. Commonly used are microsomes derived from ovary or placental tissue characterized by high aromatase activity. To a lesser extent whole cell systems are used and specifically cell systems that are potential target tissue in breast cancer development. In this study aromatase inhibitory properties of fadrozole, 8-prenylnaringenin and a synthetic lactone (TM-7) were determined in human placental microsomes and in human primary breast fibroblasts. In addition, apigenin, chrysin, naringenin and two synthetic lactones (TM-8 and TM-9) were tested in human microsomes only. Comparison of the aromatase inhibitory potencies of these compounds between the two test systems showed that the measurement of aromatase inhibition in human placental microsomes is a good predictor of aromatase inhibition in human breast fibroblasts.

60 APPLIED LIFE SCIENCES↗

Anti-Pdc1p Nanobody as a Genetically Encoded Inhibitor of Ethanol Production Enables Dual Transcriptional and Post-translational Controls of Yeast Fermentations

Microbial fermentation provides a sustainable method of producing valuable chemicals. Adding dynamic control to fermentations can significantly improve titers, but most systems rely on transcriptional controls of metabolic enzymes, leaving existing intracellular enzymes unregulated. This limits the ability of transcriptional controls to switch off metabolic pathways, especially when metabolic enzymes have long half-lives. We developed a two-layer transcriptional/post-translational control system for yeast fermentations. Specifically, the system uses blue light to transcriptionally activate the major pyruvate decarboxylase PDC1, required for cell growth and concomitant ethanol production. Switching to darkness transcriptionally inactivates PDC1 and instead activates the anti-Pdc1p nanobody, NbJRI, to act as a genetically encoded inhibitor of Pdc1p accumulated during the growth phase. This dual transcriptional/post-translational control improves the production of 2,3-BDO and citramalate by up to 100 and 92% compared to using transcriptional controls alone in dynamic two-phase fermentations. Furthermore, this study establishes the NbJRI nanobody as an effective genetically encoded inhibitor of Pdc1p that can enhance the production of pyruvate-derived chemicals.

59 BASIC BIOLOGICAL SCIENCES↗

Data for "Anti-Pdc1p Nanobody as a Genetically Encoded Inhibitor of Ethanol Production Enables Dual Transcriptional and Post-translational Controls of Yeast Fermentations"

Microbial fermentation provides a sustainable method of producing valuable chemicals. Adding dynamic control to fermentations can significantly improve titers, but most systems rely on transcriptional controls of metabolic enzymes, leaving existing intracellular enzymes unregulated. This limits the ability of transcriptional controls to switch off metabolic pathways, especially when metabolic enzymes have long half-lives. We developed a two-layer transcriptional/post-translational control system for yeast fermentations. Specifically, the system uses blue light to transcriptionally activate the major pyruvate decarboxylase PDC1 , required for cell growth and concomitant ethanol production. Switching to darkness transcriptionally inactivates PDC1 and instead activates the anti-Pdc1p nanobody, NbJRI, to act as a genetically encoded inhibitor of Pdc1p accumulated during the growth phase. This dual transcriptional/post-translational control improves the production of 2,3-BDO and citramalate by up to 100 and 92% compared to using transcriptional controls alone in dynamic two-phase fermentations. This study establishes the NbJRI nanobody as an effective genetically encoded inhibitor of Pdc1p that can enhance the production of pyruvate-derived chemicals.

metabolic engineering↗

Rapid, Approximate Multi-Axis Vibration Testing [Thesis]

The aerospace industry uses vibration shaker tables to perform component durability testing. In these tests a component, piece of equipment, or entire system is attached to a shaker table where it is subjected to dynamic excitation. The goal is to understand how the article under test will perform in its service environment without having to run it through its entire service life via field testing. In a vibration test, an aerospace system or component is qualified if it is shown to survive a test meant to replicate its lifetime service conditions. The test is designed based on recorded field data. To develop a test, a system is taken through all of its intended environments, e.g., transportation, launch, and reentry. Acceleration data measured from these environments is then brought back to the lab and imported into a shaker table controller. The controller then drives a vibration test intended to mimic the acceleration conditions experienced by the system or specific components of the system in the field. However, it is often difficult to match the measured field response in a lab test. This is largely due to the test’s boundary conditions and excitation methods. In a lab test, a shaker table is the excitation source. The two most common shaker table types, differentiated by their number of independent degrees of freedom, are single-axis and multi-axis shaker tables. Multi-axis shakers have the ability to reproduce service environments more realistically, as real accelerations inevitably produce multiple degrees of freedom of excitation simultaneously. Figure 1 depicts a generic multi-axis testing setup on a three-axis shaker table. Often multi-axis tests use six-degree-of-freedom (6DOF) shaker tables. Yet multi-axis shakers are not yet common in the aerospace industry due in part to their high cost and the difficulty for shaker controllers to handle the added complexity. Single-axis shaker tables are much more common. They are not as expensive to purchase and have a wide range of control software options.

42 ENGINEERING↗

System Effectiveness

An effective risk assessment system is needed to address the threat posed by an active or passive insider who, acting alone or in collusion, could attempt diversion or theft of nuclear material. It is critical that a nuclear facility conduct a thorough self-assessment of the material protection, control, and accountability (MPC&A) system to evaluate system effectiveness. Self-assessment involves vulnerability analysis and performance testing of the MPC&A system. The process should lead to confirmation that mitigating features of the system effectively minimize the threat, or it could lead to the conclusion that system improvements or upgrades are necessary to achieve acceptable protection against the threat. Analysis of the MPC&A system is necessary to understand the limits and vulnerabilities of the system to internal threats. Self-assessment helps the facility be prepared to respond to internal threats and reduce the risk of theft or diversion of nuclear material. MSET is a self-assessment or inspection tool utilizing probabilistic risk assessment (PRA) methodology to calculate the system effectiveness of a nuclear facility's MPC&A system. MSET analyzes the effectiveness of an MPC&A system based on defined performance metrics for MPC&A functions based on U.S. and international best practices and regulations. A facility's MC&A system can be evaluated at a point in time and reevaluated after upgrades are implemented or after other system changes occur. The total system or specific subareas within the system can be evaluated. Areas of potential performance improvement or system upgrade can be assessed to determine where the most beneficial and cost-effective improvements should be made. Analyses of risk importance factors show that sustainability is essential for optimal performance. The analyses reveal where performance degradation has the greatest detrimental impact on total system risk and where performance improvements have the greatest reduction in system risk. The risk importance factors show the amount of risk reduction achievable with potential upgrades and the amount of risk reduction actually achieved after upgrades are completed. Applying the risk assessment tool gives support to budget prioritization by showing where budget support levels must be sustained for MC&A functions most important to risk. Results of the risk assessment are also useful in supporting funding justifications for system improvements that significantly reduce system risk.

99 GENERAL AND MISCELLANEOUS↗

Summary

An effective risk assessment system is needed to address the threat posed by an active or passive insider who, acting alone or in collusion, could attempt diversion or theft of nuclear material. The material control and accountability (MC&A) system effectiveness tool (MSET) is a self-assessment or inspection tool utilizing probabilistic risk assessment (PRA) methodology to calculate the system effectiveness of a nuclear facility's material protection, control, and accountability (MPC&A) system. The MSET process is divided into four distinct and separate parts: (1) Completion of the questionnaire that assembles information about the operations of every aspect of the MPC&A system; (2) Conversion of questionnaire data into numeric values associated with risk; (3) Analysis of the numeric data utilizing the MPC&A fault tree and the SAPHIRE computer software; and (4) Self-assessment using the MSET reports to perform the effectiveness evaluation of the facility's MPC&A system. The process should lead to confirmation that mitigating features of the system effectively minimize the threat, or it could lead to the conclusion that system improvements or upgrades are necessary to achieve acceptable protection against the threat. If the need for system improvements or upgrades is indicated when the system is analyzed, MSET provides the capability to evaluate potential or actual system improvements or upgrades. A facility's MC&A system can be evaluated at a point in time. The system can be reevaluated after upgrades are implemented or after other system changes occur. The total system or specific subareas within the system can be evaluated. Areas of potential system improvement can be assessed to determine where the most beneficial and cost-effective improvements should be made. Analyses of risk importance factors show that sustainability is essential for optimal performance and reveals where performance degradation has the greatest impact on total system risk. The risk importance factors show the amount of risk reduction achievable with potential upgrades and the amount of risk reduction achieved after upgrades are completed. Applying the risk assessment tool gives support to budget prioritization by showing where budget support levels must be sustained for MC&A functions most important to risk. Results of the risk assessment are also useful in supporting funding justifications for system improvements that significantly reduce system risk. The functional model, the system risk assessment tool, and the facility evaluation questionnaire are valuable educational tools for MPC&A personnel. These educational tools provide a framework for ongoing dialogue between organizations regarding the design, development, implementation, operation, assessment, and sustainability of MPC&A systems. An organization considering the use of MSET as an analytical tool for evaluating the effectiveness of its MPC&A system will benefit from conducting a complete MSET exercise at an existing nuclear facility.

99 GENERAL AND MISCELLANEOUS↗

Exploring Ligand-to-Metal Charge-Transfer States in the Photo-Ferrioxalate System Using Excited-State Specific Optimization

The photo-ferrioxalate system (PFS), [Fe(III)(C 2 O 4 )] 3– , more than an exact chemical actinometer, has been extensively applied in wastewater and environment treatment. Despite many experimental efforts to improve clarity, important aspects of the mechanism of ferrioxalate photolysis are still under debate. In this paper, we employ the recently developed WΓ-CASSCF to investigate the ligand-to-metal charge-transfer states that are key to ferrioxalate photolysis. This investigation provides a qualitative picture of these states and key potential energy surface features related to the photolysis. Furthermore, our theoretical results are consistent with the prompt charge-transfer picture seen in recent experiments and clarify some features that are not visible in experiments. Two ligand-to-metal charge-transfer states contribute to the photolysis of ferrioxalate, and the avoided crossing barrier between them is low compared with the initial photoexcitation energy. Our data also clarify that one Fe–O bond cleaves first, followed by the C–C bond and the other Fe–O bond.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗