Search NASA⌕ Search

SEARCH · Search NASA

Results for “Systematic Error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Robust state estimation of feeding–blending systems in continuous pharmaceutical manufacturing

State estimation is a fundamental part of monitoring, control, and real-time optimization in continuous pharmaceutical manufacturing. For nonlinear dynamic systems with hard constraints, moving horizon estimation (MHE) can estimate the current state by solving a well-defined optimization problem where process complexities are explicitly considered as constraints. Traditional MHE techniques assume random measurement noise governed by some normal distributions. However, state estimates can be unreliable if noise is not normally distributed or measurements are contaminated with gross or systematic errors. In this paper, to improve the accuracy and robustness of state estimation, we incorporate robust estimators within the standard MHE skeleton, leading to an extended MHE framework. The proposed MHE approach is implemented on two pharmaceutical continuous feeding–blending system (FBS) configurations which include loss-in-weight (LIW) feeders and continuous blenders. Numerical results show that our MHE approach is robust to gross errors and can provide reliable state estimates when measurements are contaminated with outliers and drifts. Finally and moreover, the efficient solution of the MHE realized in this work, suggests feasible application of on-line state estimation on more complex continuous pharmaceutical processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A method for characterization of multiple dynamic constitutive parameters of FRCs

We propose a method to measure multiple dynamic material constitutive parameters of unidirectional fiber reinforced composites (FRCs) in a single experiment. Dynamic short-beam shear (DSBS) experiments were performed on a modified Kolsky compression bar, with integration of high-speed imaging and digital image correlation (DIC). The unidirectional FRCs investigated were S-2 glass fiber reinforced matrix of TGDDM-Jeffamine® D230 with monoamine functionalized partially reacted substructures (mPRS) and commercially available SC-15. Analytical solutions of normal and shear strains of a composite beam were derived based on Timoshenko beam theory, assuming material to be transversely isotropic and have different moduli in tension and compression in each principle material orientation. Tensile and compressive moduli were inversely computed through monitoring normal strain slope when specimen was constantly loaded at a speed of ~7.3 m/s within a small deflection. Non-linear shear stress-strain behavior of the composite was described via Ramberg–Osgood equation. Finite element (FE) analysis was conducted in ABAQUS, simultaneously defining via user subroutine UMAT the transverse isotropy of material, bi-modulus constitutive model, and non-linear shear stress-strain relation. The method proposed in this work was validated by comparing strain distributions computed by FE model and DIC measurements. Comparing with traditional dynamic tensile, compressive, and shear experiments on FRCs, this method significantly simplifies the specimen preparation and design of complicated gripping fixtures for multiple experiments. Here, systematic errors resulting from variations of specimen geometry and dimension, loading direction, and instrumentation are reduced, thereby providing compatible data for numerical studies on impact behavior of composites.

36 MATERIALS SCIENCE↗

Heavy-Baryon Spectroscopy from Lattice QCD

We use a four-dimensional lattice calculation of the full-QCD (quantum chromodynamics, the non-abliean gauge theory of the strong interactions of quarks and gluons) path integrals needed to determine the masses of the charmed and bottom baryons. In the charm sector, our results are in good agreement with experiment within our systematics, except for the spin-1/2 $\Xi_{cc}$, for which we found the isospin-averaged mass to be $\Xi_{cc}$ to be $3665\pm17\pm14^{+0}_{-78}$ MeV. We predict the mass of the (isospin-averaged) spin-1/2 $\Omega_{cc}$ to be $3763\pm19\pm26^{+13}_{-79}$ {MeV}. In the bottom sector, our results are also in agreement with experimental observations and other lattice calculations within our statistical and systematic errors. In particular, we find the mass of the $\Omega_b$ to be consistent with the recent CDF measurement. We also predict the mass for the as yet unobserved $\Xi^\prime_b$ to be 5955(27) MeV.

43 PARTICLE ACCELERATORS↗

Dynamic load balancing for petascale quantum Monte Carlo applications: The Alias method

Diffusion Monte Carlo is the most accurate widely used Quantum Monte Carlo method for the electronic structure of materials, but it requires frequent load balancing or population redistribution steps to maintain efficiency and avoid accumulation of systematic errors on parallel machines. The load balancing step can be a significant factor affecting performance, and will become more important as the number of processing elements increases. We propose a new dynamic load balancing algorithm, the Alias Method, and evaluate it theoretically and empirically. An important feature of the new algorithm is that the load can be perfectly balanced with each process receiving at most one message. It is also optimal in the maximum size of messages received by any process. We also optimize its implementation to reduce network contention, a process facilitated by the low messaging requirement of the algorithm. Empirical results on the petaflop Cray XT Jaguar supercomputer at ORNL showing up to 30% improvement in performance on 120,000 cores. The load balancing algorithm may be straightforwardly implemented in existing codes. The algorithm may also be employed by any method with many near identical computational tasks that requires load balancing.

97 MATHEMATICS AND COMPUTING↗

Retrieval of water vapor column abundance and aerosol properties from ChemCam passive sky spectroscopy

In this work, we derive water vapor column abundances and aerosol properties from Mars Science Laboratory (MSL) ChemCam passive mode observations of scattered sky light. This paper covers the methodology and initial results for water vapor and also provides preliminary results for aerosols. The data set presented here includes the results of 113 observations spanning from Mars Year 31 L s = 291° (March 30, 2013) to Mars Year 33 L s = 127° (March 24, 2016). Each ChemCam passive sky observation acquires spectra at two different elevation angles. We fit these spectra with a discrete-ordinates multiple scattering radiative transfer model, using the correlated-k approximation for gas absorption bands. The retrieval proceeds by first fitting the continuum of the ratio of the two elevation angles to solve for aerosol properties, and then fitting the continuum-removed ratio to solve for gas abundances. The final step of the retrieval makes use of the observed CO 2 absorptions and the known CO 2 abundance to correct the retrieved water vapor abundance for the effects of the vertical distribution of scattering aerosols and to derive an aerosol scale height parameter. Our water vapor results give water vapor column abundance with a precision of ±0.6 precipitable microns and systematic errors no larger than ±0.3 precipitable microns, assuming uniform vertical mixing. The ChemCam-retrieved water abundances show, with only a few exceptions, the same seasonal behavior and the same timing of seasonal minima and maxima as the TES, CRISM, and REMS-H data sets that we compare them to. However ChemCam-retrieved water abundances are generally lower than zonal and regional scale from-orbit water vapor data, while at the same time being significantly larger than pre-dawn REMS-H abundances. Pending further analysis of REMS-H volume mixing ratio uncertainties, the differences between ChemCam and REMS-H pre-dawn mixing ratios appear to be much too large to be explained by large scale circulations and thus they tend to support the hypothesis of substantial diurnal interactions of water vapor with the surface. Our preliminary aerosol results, meanwhile, show the expected seasonal pattern in dust particle size but also indicate a surprising interannual increase in water–ice cloud opacities.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis and improvement of the hot disk transient plane source method for low thermal conductivity materials

The hot disk transient plane source (TPS) method is a widely used standard technique (ISO 22007-2) for the characterization of thermal properties of materials, especially the thermal conductivity, k. Despite its well-established reliability for a wide variety of common materials, the hot disk TPS method is also known to suffer from a substantial systematic errors when applied to low-k thermal insulation materials. Here, we present a combined numerical and experimental study on the influence of the geometry of hot disk sensor on measured value of low-k materials. We demonstrate that the error is strongly affected by the finite thickness and thermal mass of the sensor's insulation layer was well as the corresponding increase of the effective heater size beyond the radius of the embedded metal heater itself. We also numerically investigate the dependence of the error on the sample thermal properties, confirming that the errors are worse in low-k samples. A simple correction function is also provided, which converts the apparent (erroneous) result from a standard hot disk TPS measurement to a more accurate value. A standard polyimide sensor was also optimized using both wet and dry etching to provide more accurate measurement directly. Experimentally corrected value of k for Airloy x56 aerogel and a commercial silica aerogel using the numerical correction factor derived based on the standard TPS sensor is in excellent agreement with the directly measured value from the TPS sensor using the optimized polyimide sensor. Finally, both of these methods can reduce the errors to less than 4% as compared to around 40% error of overestimation from raw values measured with the pristine sensor. Such results show that both the numerical correction to a pristine senor or an optimized sensor are capable of providing highly accurate value of thermal conductivity for such materials.

36 MATERIALS SCIENCE↗

Inter- and Intrafraction Variability in Liver Position in Non-Breath-Hold Stereotactic Body Radiotherapy

Purpose: The inter- and intrafraction variability of liver position was assessed in patients with liver cancer treated with kilovoltage cone-beam computed tomography (CBCT)-guided stereotactic body radiotherapy. Methods and Materials: A total of 314 CBCT scans obtained in the treatment position immediately before and after each fraction were evaluated from 29 patients undergoing six-fraction, non-breath-hold stereotactic body radiotherapy for unresectable liver cancer. Off-line, the CBCT scans were sorted into 10 bins, according to the phase of respiration. The liver position (relative to the vertebral bodies) was measured using rigid alignment of the exhale CBCT liver with the exhale planning CT liver, following the alignment of the vertebrae. The interfraction liver position change was measured by comparing the pretreatment CBCT scans, and the intrafraction change was measured from the CBCT scans obtained immediately before and after each fraction. Results: The mean amplitude of liver motion for all patients was 1.8 mm (range, 0.1-5.7), 8.0 mm (range, 0.1-18.8), and 4.3 mm (range 0.1-12.1) in the medial-lateral (ML), craniocaudal (CC), and anteroposterior (AP) directions, respectively. The mean absolute ML, CC, and AP interfraction changes in liver position were 2.0 mm (90th percentile, 4.2), 3.5 mm (90th percentile, 7.3), and 2.3 mm (90th percentile, 4.7). The mean absolute intrafraction ML, CC, and AP changes were 1.3 mm (90th percentile, 2.9), 1.6 mm (90th percentile, 3.6), and 1.5 mm (90th percentile, 3.1), respectively. The interfraction changes were significantly larger than the intrafraction changes, with a CC systematic error of 2.9 and 1.1 mm, respectively. The intraobserver reproducibility ({sigma}, n = 29 fractions) was 1.3 mm in the ML, 1.4 mm in the CC, and 1.6 mm in the AP direction. Conclusion: Interfraction liver position changes relative to the vertebral bodies are an important source of geometric uncertainty, providing a rationale for prefraction soft-tissue image guidance. The intrafraction change in liver position from the beginning to the end of each fraction was small for most patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rectal Motion in Patients Receiving Preoperative Radiotherapy for Carcinoma of the Rectum

Purpose: To assess the movement of rectum, mesorectum, and rectal primary during a course of preoperative chemoradiotherapy. Methods and Materials: Seventeen patients with Stage II or III rectal cancer had a planning CT scan with rectal contrast before commencement of preoperative chemoradiation. The scan was repeated during Weeks 1, 3, and 5 of chemoradiation. The rectal primary (gross tumor volume), rectum, mesorectum, and bladder were contoured on all four scans. An in-house biomechanical model-based deformable image registration technique, Morfeus, was used to measure the three-dimensional spatial change in these structures after bony alignment. The required planning target volume margin for this spatial change, after bone alignment, was also calculated. Results: Rectal contrast was found to introduce a systematic error in the position of all organs compared with the noncontrast state. The largest change in structures during radiotherapy was in the anterior and posterior directions for the mesorectum and rectum and in the superior and inferior directions for the gross tumor volume. The planning target volume margins required for internal movement for the mesorectum based on the three scans acquired during treatment are 4 mm right, 5 mm left, 7 mm anterior, and 6 mm posterior. For the rectum, values were 8 mm right, 8 mm left, 8 mm anterior, and 9 mm posterior. The greatest movement of the rectum occurred in the upper third. Conclusions: Contrast is no longer used in CT simulation. Assuming bony alignment, a nonuniform margin of 8 mm anteriorly, 9 mm posteriorly, and 8 mm left and right is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of the Absorbed Dose Rate to Water for the 18-mm Helmet of a Gamma Knife

Purpose: To measure the absorbed dose rate to water of {sup 60}Co gamma rays of a Gamma Knife Model C using water-filled phantoms (WFP). Methods and Materials: Spherical WFP with an equivalent water depth of 5, 7, 8, and 9 cm were constructed. The dose rates at the center of an 18-mm helmet were measured in an 8-cm WFP (WFP-3) and two plastic phantoms. Two independent measurement systems were used: one was calibrated to an air kerma (Set I) and the other was calibrated to the absorbed dose to water (Set II). The dose rates of WFP-3 and the plastic phantoms were converted to dose rates for an 8-cm water depth using the attenuation coefficient and the equivalent water depths. Results: The dose rate measured at the center of WFP-3 using Set II was 2.2% and 1.0% higher than dose rates measured at the center of the two plastic phantoms. The measured effective attenuation coefficient of Gamma Knife photon beam in WFPs was 0.0621 cm{sup -1}. After attenuation correction, the difference between the dose rate at an 8-cm water depth measured in WFP-3 and dose rates in the plastic phantoms was smaller than the uncertainty of the measurements. Conclusions: Systematic errors related to the characteristics of the phantom materials in the dose rate measurement of a Gamma Knife need to be corrected for. Correction of the dose rate using an equivalent water depth and attenuation provided results that were more consistent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Practical Use of the Extended No Action Level (eNAL) Correction Protocol for Breast Cancer Patients With Implanted Surgical Clips

Purpose: To describe the practical use of the extended No Action Level (eNAL) setup correction protocol for breast cancer patients with surgical clips and evaluate its impact on the setup accuracy of both tumor bed and whole breast during simultaneously integrated boost treatments. Methods and Materials: For 80 patients, two orthogonal planar kilovoltage images and one megavoltage image (for the mediolateral beam) were acquired per fraction throughout the radiotherapy course. For setup correction, the eNAL protocol was applied, based on registration of surgical clips in the lumpectomy cavity. Differences with respect to application of a No Action Level (NAL) protocol or no protocol were quantified for tumor bed and whole breast. The correlation between clip migration during the fractionated treatment and either the method of surgery or the time elapsed from last surgery was investigated. Results: The distance of the clips to their center of mass (COM), averaged over all clips and patients, was reduced by 0.9 {+-} 1.2 mm (mean {+-} 1 SD). Clip migration was similar between the group of patients starting treatment within 100 days after surgery (median, 53 days) and the group starting afterward (median, 163 days) (p = 0.20). Clip migration after conventional breast surgery (closing the breast superficially) or after lumpectomy with partial breast reconstructive techniques (sutured cavity). was not significantly different either (p = 0.22). Application of eNAL on clips resulted in residual systematic errors for the clips' COM of less than 1 mm in each direction, whereas the setup of the breast was within about 2 mm of accuracy. Conclusions: Surgical clips can be safely used for high-accuracy position verification and correction. Given compensation for time trends in the clips' COM throughout the treatment course, eNAL resulted in better setup accuracies for both tumor bed and whole breast than NAL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deformable Image Registration for Adaptive Radiation Therapy of Head and Neck Cancer: Accuracy and Precision in the Presence of Tumor Changes

Purpose: To compare deformable image registration (DIR) accuracy and precision for normal and tumor tissues in head and neck cancer patients during the course of radiation therapy (RT). Methods and Materials: Thirteen patients with oropharyngeal tumors, who underwent submucosal implantation of small gold markers (average 6, range 4-10) around the tumor and were treated with RT were retrospectively selected. Two observers identified 15 anatomical features (landmarks) representative of normal tissues in the planning computed tomography (pCT) scan and in weekly cone beam CTs (CBCTs). Gold markers were digitally removed after semiautomatic identification in pCTs and CBCTs. Subsequently, landmarks and gold markers on pCT were propagated to CBCTs, using a b-spline-based DIR and, for comparison, rigid registration (RR). To account for observer variability, the pair-wise difference analysis of variance method was applied. DIR accuracy (systematic error) and precision (random error) for landmarks and gold markers were quantified. Time trend of the precisions for RR and DIR over the weekly CBCTs were evaluated. Results: DIR accuracies were submillimeter and similar for normal and tumor tissue. DIR precision (1 SD) on the other hand was significantly different (P<.01), with 2.2 mm vector length in normal tissue versus 3.3 mm in tumor tissue. No significant time trend in DIR precision was found for normal tissue, whereas in tumor, DIR precision was significantly (P<.009) degraded during the course of treatment by 0.21 mm/week. Conclusions: DIR for tumor registration proved to be less precise than that for normal tissues due to limited contrast and complex non-elastic tumor response. Caution should therefore be exercised when applying DIR for tumor changes in adaptive procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Head and Neck Margin Reduction With Adaptive Radiation Therapy: Robustness of Treatment Plans Against Anatomy Changes

Purpose: We set out to investigate loss of target coverage from anatomy changes in head and neck cancer patients as a function of applied safety margins and to verify a cone beam computed tomography (CBCT)–based adaptive strategy with an average patient anatomy to overcome possible target underdosage. Methods and Materials: For 19 oropharyngeal cancer patients, volumetric modulated arc therapy treatment plans (2 arcs; simultaneous integrated boost, 70 and 54.25 Gy; 35 fractions) were automatically optimized with uniform clinical target volume (CTV)–to–planning target volume margins of 5, 3, and 0 mm. We applied b-spline CBCT–to–computed tomography (CT) deformable registration to allow recalculation of the dose on modified CT scans (planning CT deformed to daily CBCT following online positioning) and dose accumulation in the planning CT scan. Patients with deviations in primary or elective CTV coverage >2 Gy were identified as candidates for adaptive replanning. For these patients, a single adaptive intervention was simulated with an average anatomy from the first 10 fractions. Results: Margin reduction from 5 mm to 3 mm to 0 mm generally led to an organ-at-risk (OAR) mean dose (D{sub mean}) sparing of approximately 1 Gy/mm. CTV shrinkage was mainly seen in the elective volumes (up to 10%), likely related to weight loss. Despite online repositioning, substantial systematic errors were present (>3 mm) in lymph node CTV, the parotid glands, and the larynx. Nevertheless, the average increase in OAR dose was small: maximum of 1.2 Gy (parotid glands, D{sub mean}) for all applied margins. Loss of CTV coverage >2 Gy was found in 1, 3, and 7 of 73 CTVs, respectively. Adaptive intervention in 0-mm plans substantially improved coverage: in 5 of 7 CTVs (in 6 patients) to <2 Gy of initially planned. Conclusions: Volumetric modulated arc therapy head and neck cancer treatment plans with 5-mm margins are robust for anatomy changes and show a modest increase in OAR dose. Margin reduction improves OAR sparing with approximately 1 Gy/mm at the expense of target coverage in a subgroup of patients. Patients at risk of CTV underdosage >2 Gy in 0-mm plans may be identified early in treatment using dose accumulation. A single intervention with an average anatomy derived from CBCT effectively mitigates discrepancies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atomic Layer Thermopiles: Comprehensive static calibration, comparison and application in subsonic and supersonic flows

Here, this paper compares the calibration of different heat flux sensors in radiation- and convection-based sub- and supersonic operation. First, four heat flux sensors based on different principles: ALTP (Transverse Seebeck Effect), HFM-8E (differential-layer device), coaxial Thermocouple and a TG-2000 (circular-foil gage) are calibrated in a laser-based radiation setup. In a second step, all heat flux sensors are compared with a slug-calorimeter within a subsonic convection-dominated facility based on stagnation-point measurements of an impinging hot air jet. The obtained results indicate that a sensitivity transfer between a radiative calibrated sensor used in a mainly convective environment is not always possible and can lead to significant, systematic errors. Calibration in a subsonic shear flow with thermocouple readings demonstrate small divergence from the manufacturer provided sensitivity. Finally, supersonic testing with high frequency shock-boundary layer interactions highlight the need for ALTP rather than the conventional use of thermocouple arrays to resolve the high frequency phenomena associated with shock boundary layer interactions.

42 ENGINEERING↗

Effects of natural zeolites on field-scale geologic noble gas transport

Improving predictive models for noble gas transport through natural materials at the field-scale is an essential component of improving US nuclear monitoring capabilities. Several field-scale experiments with a gas transport component have been conducted at the Nevada National Security Site (Non-Proliferation Experiment, Underground Nuclear Explosion Signatures Experiment). However, the models associated with these experiments have not treated zeolite minerals as gas adsorbing phases. This is significant as zeolites are a common alteration mineral with a high abundance at these field sites and are shown here to significantly fractionate noble gases during field-scale transport. This fractionation and associated retardation can complicate gas transport predictions by reducing the signal-to-noise ratio to the detector (e.g. mass spectrometers or radiation detectors) enough to mask the signal or make the data difficult to interpret. Omitting adsorption-related retardation data of noble gases in predictive gas transport models therefore results in systematic errors in model predictions where zeolites are present.Herein is presented noble gas adsorption data collected on zeolitized and non-zeolitized tuff. Experimental results were obtained using a unique piezometric adsorption system designed and built for this study. Data collected were then related to pure-phase mineral analyses conducted on clinoptilolite, mordenite, and quartz. These results quantify the adsorption capacity of materials present in field-scale systems, enabling the modeling of low-permeability rocks as significant sorption reservoirs vital to bulk transport predictions.

58 GEOSCIENCES↗

Analyte-induced spectral filtering in femtosecond transient absorption spectroscopy

Here, we discuss the influence of spectral filtering by samples in femtosecond transient absorption measurements. Commercial instruments for transient absorption spectroscopy (TA) have become increasingly available to scientists in recent years and TA is becoming an established technique to measure the dynamics of photoexcited systems. Furthermore, we show that absorption of the excitation pulse by the sample can severely alter the spectrum and consequently the temporal pulse shape. This “spectral self-filtering” effect can lead to systematic errors and misinterpretation of data, most notably in concentration dependent measurements. Finally, the combination of narrow absorption peaks in the sample with ultrafast broadband excitation pulses is especially prone to this effect.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multispectrum analysis of the oxygen A-band

Retrievals of atmospheric composition from near-infrared measurements require measurements of airmass to better than the desired precision of the composition. The oxygen bands are obvious choices to quantify airmass since the mixing ratio of oxygen is fixed over the full range of atmospheric conditions. The OCO-2 mission is currently retrieving carbon dioxide concentration using the oxygen A-band for airmass normalization. The 0.25% accuracy desired for the carbon dioxide concentration has pushed the required state-of-the-art for oxygen spectroscopy. To measure O2 A-band cross-sections with such accuracy through the full range of atmospheric pressure requires a sophisticated line-shape model (Rautian or Speed-Dependent Voigt) with line mixing (LM) and collision induced absorption (CIA). Models of each of these phenomena exist, however, this work presents an integrated self-consistent model developed to ensure the best accuracy. It is also important to consider multiple sources of spectroscopic data for such a study in order to improve the dynamic range of the model and to minimize effects of instrumentation and associated systematic errors. The techniques of Fourier Transform Spectroscopy (FTS) and Cavity Ring-Down Spectroscopy (CRDS) allow complimentary information for such an analysis. We utilize multispectrum fitting software to generate a comprehensive new database with improved accuracy based on these datasets. As a result, the extensive information will be made available as a multi-dimensional cross-section (ABSCO) table and the parameterization will be offered for inclusion in the HITRANonline database.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stereology of backscatter electron images of etched surfaces for characterization of particle size distributions and volume fractions: Estimation of imaging bias via Monte Carlo simulations

On metallic specimens in which a secondary phase has been selectively removed by a chemical etchant, the use of backscatter electron (BSE) imaging yields images that are more readily segmented with image processing algorithms than other modes of imaging in the scanning electron microscope. The contrast mechanisms in this imaging mode, however, produce a bias in the observation of particle sizes and volume fractions due to the effects of the electron interaction volume in the specimen. This stereological bias is quantified using Monte Carlo (MC) simulation of backscatter images. It is observed that the overprojection of features with centroids residing beneath the plane of polish is largely canceled out by the reduced segmentation size of features with centroids residing above the plane of polish. - Research Highlights: {yields} Backscatter imaging of selectively-etched surfaces can facilitate segmentation. {yields} Backscatter imaging of voids is simulated to estimate imaging/observation biases. {yields} The biases are quantified and incorporated into the stereological calculation. {yields} Systematic errors and imaging biases are observed to counteract one another. {yields} Results are illustrated using a bimodal gamma prime distribution in a Ni superalloy.

36 MATERIALS SCIENCE↗

Dosimetric Impact of Intrafractional Patient Motion in Pediatric Brain Tumor Patients

The purpose of this study was to determine the dosimetric consequences of intrafractional patient motion on the clinical target volume (CTV), spinal cord, and optic nerves for non-sedated pediatric brain tumor patients. The patients were immobilized for treatment using a customized thermoplastic full-face mask and bite-block attached to an array of reflectors. The array was optically tracked by infra-red cameras at a frequency of 10 Hz. Patients were localized based on skin/mask marks and weekly films were taken to ensure proper setup. Before each noncoplanar field was delivered, the deviation from baseline of the array was recorded. The systematic error (SE) and random error (RE) were calculated. Direct simulation of the intrafractional motion was used to quantify the dosimetric changes to the targets and critical structures. Nine patients utilizing the optical tracking system were evaluated. The patient cohort had a mean of 31 {+-} 1.5 treatment fractions; motion data were acquired for a mean of 26 {+-} 6.2 fractions. The mean age was 15.6 {+-} 4.1 years. The SE and RE were 0.4 and 1.1 mm in the posterior-anterior, 0.5 and 1.0 mm in left-right, and 0.6 and 1.3 mm in superior-inferior directions, respectively. The dosimetric effects of the motion on the CTV were negligible; however, the dose to the critical structures was increased. Patient motion during treatment does affect the dose to critical structures, therefore, planning risk volumes are needed to properly assess the dose to normal tissues. Because the motion did not affect the dose to the CTV, the 3-mm PTV margin used is sufficient to account for intrafractional motion, given the patient is properly localized at the start of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗