Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEST PROTOCOL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

A Test Bed to Evaluate Advanced Distribution Management Systems for Modern Power Systems

This paper presents a test bed that utilities, vendors, and researchers can use to evaluate the performance of existing and emerging advanced distribution management systems (ADMS) or specific applications of such systems. The test bed provides a realistic laboratory test setting, including detailed modeling of the power system, controller and/or power hardware, and industry-standard communication protocols. The test bed can further represent the current state of a specific utility's distribution system or the anticipated state with increased penetrations of distributed energy resources, such as rooftop photovoltaic systems, residential battery energy storage systems, electric vehicles, and loads with smart controls. The paper describes the design and implementation of the test bed. We present two use cases of the test bed and preliminary results for these two use cases. We also discuss upcoming and potential future use cases. Results from test bed experiments are intended to accelerate industry deployment of ADMS technologies and advance development of ADMS capabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Crew report

A 56-day chamber simulation of Skylab was successfully completed. The atmosphere (5 psi, 70 percent oxygen, 30 percent nitrogen, 5 mm carbon dioxide) and medical features including a 21-day pre- and 18-day post-test medical protocols were closely simulated. No apparent crew health problems were induced by the atmosphere, semiclosed environment, or other test features; and no appreciable crew degradation appeared over this period. The chamber and associated systems performed without major problems.

Bobko, K. J.↗

A Test Bed to Evaluate Advanced Distribution Management Systems for Modern Power Systems: Preprint

This paper presents a test bed that utilities, vendors, and researchers can use to evaluate the performance of existing and emerging advanced distribution management systems (ADMS) or specific applications of such systems. The test bed provides a realistic laboratory test setting, including detailed modeling of the power system, controller and/or power hardware, and industry-standard communication protocols. The test bed can further represent the current state of a specific utility's distribution system or the anticipated state with increased penetrations of distributed energy resources, such as rooftop photovoltaic systems, residential battery energy storage systems, electric vehicles, and loads with smart controls. The paper describes the design and implementation of the test bed. We present two use cases of the test bed and preliminary results for these two use cases. We also discuss upcoming and potential future use cases. Results from test bed experiments can be used to accelerate industry deployment of ADMS technologies and advance development of ADMS capabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spaceflight Autonomous Multigenerational Microbial Sequencer (SAMMS) in Support of Plant-Growth Systems

As the National Aeronautics and Space Association (NASA) begins to pursue long-duration space flights, they will need to be able to provide astronauts with a nutritious and reliable food source. To meet the administration’s goal of traveling to the Moon and Mars, astronauts will need to begin to grow their own food in space. To protect their food source, extensive monitoring will occur to test for the effects of a space flight environment (e.g., radiation) as well as for early pathogen and disease detection. Genomic sequencing allows for both concerns to be tested on a regular basis. However, NASA’s current sequencer is unable to process plant tissues. Therefore, a novel method for plant DNA extraction using microneedle (MN) patches that will be able to feed into NASA’s existing system, but also require minimal human input is proposed. To support this, the design was broken down into four components (1) MN patch fabrication (2) MN patch extraction, (3) automated sampling motion control, and (4) a processing module. The MN patch is fabricated using a custom mold with conically shaped needles. The mold is filled with Polyvinyl alcohol (PVA) solution and placed in a vacuum desiccator. The mold is left in the vacuum overnight until the patch is dry and ready for use. The protocol was tested with varying pressures, drying times, volume amounts, and preparation methods to determine if highquality needles can be produced. A MN is a method of DNA extraction where the patch is applied to a leaf, the needles penetrate the leaf, breaking the rigid plant cell wall to isolate the DNA. A protocol for this method of extraction was tested to ensure the patch could produce the needed yield and purity. The tests varied by the number of patches, number of applications, and plant type. To automate the MN extraction method, motion control will utilize two separate axis tables which move in the x and y directions. The y-axis table will have an end effector that fits a MN patch and will have the ability to apply the patch to the leaf sample. This end effector will also act as a lid for a downstream processing module. The other axis will position the leaf sample and processing container so that the patch can be applied accurately. The Joint Comprehensive Sequencing System (JCSS) module integrates all the components together. The output of this module feeds into the NASA Charged Information-Storage Polymer Preparation System (CHIPPS) for genomic sequencing. The extraction module operates using a series of syringes and tubing to pump the varying reagents needed for the extraction protocol. The results of the study proved that MN patches are a viable method of DNA extraction. While fabrication of high-quality needles was unsuccessful, the protocol was able to be further developed using centrifugation. The integrated design between the motion control and the JCSS enabled the potential for automation with a complete conceptual design and prototype. Future research and development for this study would include (1) further testing for fabrication (2) expanding the range of plant species compatible with the MN patch, and (3) building a working prototype for the integrated system.

Peter Ling↗

Quality Assurance Protocol for AFCI Advanced Structural Materials Testing

The objective of this letter is to inform you of recent progress on the development of advanced structural materials in support of advanced fast reactors and AFCI. As you know, the alloy development effort has been initiated in recent months with the procurement of adequate quantities of the NF616 and HT-UPS alloys. As the test alloys become available in the coming days, mechanical testing, evaluation of optimizing treatments, and screening of environmental effects will be possible at a larger scale. It is therefore important to establish proper quality assurance protocols for this testing effort in a timely manner to ensure high technical quality throughout testing. A properly implemented quality assurance effort will also enable preliminary data taken in this effort to be qualified as NQA-1 during any subsequent licensing discussions for an advanced design or actual prototype. The objective of this report is to describe the quality assurance protocols that will be used for this effort. An essential first step in evaluating quality protocols is assessing the end use of the data. Currently, the advanced structural materials effort is part of a long-range, basic research and development effort and not, as yet, involved in licensing discussions for a specific reactor design. After consultation with Mark Vance (an ORNL QA expert) and based on the recently-issued AFCI QA requirements, the application of NQA-1 quality requirements will follow the guidance provided in Part IV, Subpart 4.2 of the NQA-1 standard (Guidance on Graded Application of QA for Nuclear-Related Research and Development). This guidance mandates the application of sound scientific methodology and a robust peer review process in all phases, allowing for the data to be qualified for use even if the programmatic mission changes to include licensing discussions of a specific design or prototype. ORNL has previously implemented a QA program dedicated to GNEP activities and based on an appropriately graded application of NQA-1 requirements at the site. The current program is being revised to incorporate changes imposed through the recently revised AFCI Technical Integration Office QA requirements. Testing conducted under the AFCI QA program for the advanced structural materials effort shall incorporate the following quality assurance expectations: (1) personnel are adequately trained to perform assigned work; (2) activities are controlled to ensure consistency of results; (3) records necessary to substantiate how the work was performed are maintained (dedicated laboratory notebooks will be used); (4) the pedigree and traceability of the various tested materials are maintained throughout the described processes using consistent sample numbering and adequate record keeping; (5) equipment with the potential to affect the quality of the planned work is calibrated and maintained in accordance with applicable operating requirements. In addition, all reporting or related dissemination by ORNL personnel of the results of the work described in this subcontract shall be conducted in accordance with the requirements described or referenced in the ORNL Standards Based Management System subject area entitled Scientific and Technical Information. Reporting or publications at other institutions will be conducted in accordance with the requirements of that institution. Successful implementation of these protocols will provide a sound basis for future decisions and research. In addition, these steps will also help ensure that results can also be applied to licensing discussions at a future date.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-P-46: Clinical Acceptance Testing and Implementation of a Portable CT Unit

Purpose: Planning for the first installation in New England of a new portable CT unit to be used in the Operating Room required the integration of many departments including Surgery, Neurosurgery, Information Services, Clinical Engineering, Radiology and Medical Physics/Radiation Safety. Acceptance testing and the quality assurance procedures were designed to optimize image quality and patient and personnel radiation exposure. Methods: The vendor’s protocols were tested using the CT Dosimetry phantoms. The system displayed the CTDIw instead of the CTDIvol while testing the unit. Radiation exposure was compared to existing CT scanners from installed CT units throughout the facility. Brainlab measures all 4 periphery slots on the CT Dosimetry phantom. The ACR measures only the superior slot for the periphery measurement. A comprehensive radiation survey was also performed for several locations. Results: The CTDIvol measurements were comparable for the following studies: brain, C-Spine, and sinuses. However, the mobile CT measurements were slightly higher than other CT units but within acceptable tolerance if measured using the ACR method.Based on scatter measurements, it was determined if any personnel were to stay in the OR Suite during image acquisition that the appropriate lead apron and thyroid shields had to be worn.In addition, to reduce unnecessary scatter, there were two mobile 6 foot wide shields (1/16″ lead equivalent) available to protect personnel in the room and adjacent areas. Conclusion: Intraoperative CT provides the physician new opportunities for evaluation of the progression of surgical resections and device placement at the cost of increasing the amount of trained personnel required to perform this procedure. It also brings with it challenges to keep the radiation exposure to the patients and staff within reasonable limits.

60 APPLIED LIFE SCIENCES↗

Mobile Ocean Test Berth Support: Cooperative Research and Development Final Report, CRADA Number CRD-10-413

The Northwest National Marine Renewable Energy Center (NNMREC), headquartered at the Oregon State University, is establishing the capabilities to test prototype wave energy conversion devices in the ocean. This CRADA will leverage the technical expertise and resources at NREL in the wind industry and in ocean engineering to support and enhance the development of the NNMREC Mobile Ocean Test Berth (MOTB). This CRADA will provide direct support to NNMREC by providing design evaluation and review of the MOTB, developing effective protocols for testing of the MOTB and wave energy conversion devices in the ocean, assisting in the specification of appropriate instrumentation and data acquisition packages, and providing guidance on obtaining and maintaining A2LA (American Association for Laboratory Accreditation) accreditation.

16 TIDAL AND WAVE POWER↗

Storage Resource Manager version 2.2: Design, implementation, and testing experience

Storage Services are crucial components of the Worldwide LHC Computing Grid Infrastructure spanning more than 200 sites and serving computing and storage resources to the High Energy Physics LHC communities. Up to tens of Petabytes of data are col lected every year by the four LHC experiments at CERN. To process these large data volumes it is important to establish a protocol and a very efficient interface to the various storage solutions adopted by the WLCG sites. In this work we report on the exp erience acquired during the definition of the Storage Resource Manager v2.2 protocol. In particular, we focus on the study performed to enhance the interface and make it suitable for use by the WLCG communities. At the moment 5 different storage solutions implement the SRM v2.2 interface: BeStMan (LBNL), CASTOR (CERN and RAL), dCache (DESY and FNAL), DPM (CERN), and StoRM (INFN and ICTP). After a detailed inside review of the protocol, various test suites have been written identifying the most effective s et of tests: the S2 test suite from CERN and the SRM-Tester test suite from LBNL. Such test suites have helped verifying the consistency and coherence of the proposed protocol and validating existing implementations. We conclude our work describing the re sults achieved.

Donno, Flavia↗

Approximate simulation of entanglement with a linear cost of communication

Bell's theorem implies that the outcomes of local measurements on two maximally entangled systems cannot be simulated without classical communication between the parties. The communication cost is finite for n Bell states, but it grows exponentially in n. Three simple protocols are presented that provide approximate simulations for low-dimensional entangled systems and require a linearly growing amount of communication. We have tested them by performing some simulations for a family of measurements. The maximal error is less than 1% in three dimensions and grows sublinearly with the number of entangled bits in the range numerically tested. One protocol is the multidimensional generalization of the exact Toner-Bacon [Phys. Rev. Lett. 91, 187904 (2003)] model for a single Bell state. The other two protocols are generalizations of an alternative exact model, which we derive from the Kochen-Specker [J. Math. Mech. 17, 59 (1967)] scheme for simulating single-qubit measurements. These protocols can give some indication for finding optimal one-way communication protocols that classically simulate entanglement and quantum channels. Furthermore they can be useful for deciding if a quantum communication protocol provides an advantage on classical protocols.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extreme Fast Charging: Effect of Positive Electrode Material on Crosstalk

Extreme fast charging (XFC) is a key requirement for the adoption of battery-based electric vehicles by the transportation sector. However, XFC has been shown to accelerate degradation, causing the capacity, life, and safety of batteries to deteriorate. We tested cells containing five positive electrode chemistries, LFP (olivine structure), LMO (spinel), LCO (layered), NMC811 (layered) and NCA (layered), using fast-charging protocols. After testing, the negative electrodes from cells containing positive electrodes crystallizing with a layered structure were found to have more lithium deposited on their surfaces. Further, those crystallizing with a layered structure also tended to have a larger increase in impedance than those crystallizing with a spinel or olivine structure. Characterization of the negative electrodes by X-ray photoelectron spectroscopy showed that using the concentrations of LiF and Li x PO y F z as metrics, the concentration of LiF in the SEI from the cell with different positive electrodes is LFP > LMO > LCO ~ NMC811 > NCA; and for Li x PO y F z , the order is LMO > LFP > NCA > NMC811 > LCO. Clearly, the positive-electrode material was influencing the amounts of these materials formed.

25 ENERGY STORAGE↗

Mars Sample Return: Risk Management & Sample Safety Assessment

Returning samples from Mars has long been a major planetary science objective due to the high scientific value and transformative potential of the resulting data. An exciting dimension of this objective is the potential for the detection of ancient microbiological life, and the possibility of improving our understanding of the evolution of habitable environments on Mars and the development of life on Earth. To ensure that returned samples meet stringent planetary protection requirements and do not expose Earth to potential biohazards, the joint NASA/ESA Sample Receiving Project (SRP) assembled the Sample Safety Assessment Protocol Tiger Team (SSAP-TT). Members were recruited with the specific goal of creating a multi-disciplinary and internationally distributed team of experts in their respective fields across the federal government, academia, and private industry. This team was chartered with reassessing previous sample safety assessment strategies, defining what constitutes a biological hazard, developing a protocol to test for potential biohazards, and establishing a statistical framework to determine if samples are “safe” for release. The team developed a three-step protocol, supported by a Bayesian statistical framework, to assess whether returned samples contain potential biohazards that could present a risk to Earth’s biosphere. Initial conclusions indicated that an effective and comprehensive safety assessment protocol is feasible using modern techniques and does not require an excessive amount of sample consumption or traditional microbiological detection methodology. Herein, we will present an overview of the MSR SRP, the proposed safety assessment protocol, and how aspects of this novel approach can be applied to biological assessment in healthcare product manufacturing practices.

Alvin L Smith↗

Development of a mechanical testing assay for fibrotic murine liver

In this article, a novel protocol for mechanical testing, combined with finite element modeling, is presented that allows the determination of the elastic modulus of normal and fibrotic murine livers and is compared to an independent mechanical testing method. The novel protocol employs suspending a portion of murine liver tissue in a cylindrical polyacrylamide gel, imaging with a microCT, conducting mechanical testing, and concluding with a mechanical property determination via a finite element method analysis. More specifically, the finite element model is built from the computerized tomography (CT) images, and boundary conditions are imposed in order to simulate the mechanical testing conditions. The resulting model surface stress is compared to that obtained during mechanical testing, which subsequently allows for direct evaluation of the liver modulus. The second comparison method involves a mechanical indentation test performed on a remaining liver lobe for comparison. In addition, this lobe is used for histological analysis to determine relationships between elasticity measurements and tissue health. This complete system was used to study 14 fibrotic livers displaying advanced fibrosis (injections with irritant), three control livers (injections without irritant), and three normal livers (no injections). The moduli evaluations for nondiseased livers were estimated as 0.62{+-}0.09 kPa and 0.59{+-}0.1 kPa for indenter and model-gel-tissue (MGT) assay tests, respectively. Moduli estimates for diseased liver ranged from 0.6-1.64 kPa and 0.96-1.88 kPa for indenter and MGT assay tests, respectively. The MGT modulus, though not equivalent to the modulus determined by indentation, demonstrates a high correlation, thus indicating a relationship between the two testing methods. The results also showed a clear difference between nondiseased and diseased livers. The developed MGT assay system is quite compact and could easily be utilized for controlled evaluation of soft-tissue moduli as shown here. In addition, future work will add the correlative method of elastography such that direct controlled validation of measurement on tissue can be determined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance Evaluation of Distributed Energy Resources Management System via Advanced Hardware-in-the-Loop Simulation: Preprint

This paper presents an advanced hardware-in-the-loop (HIL) platform to evaluate the performance of voltage regulation coordinated across advanced distribution management systems (ADMS), distributed energy management system (DERMS), and DERs. The HIL platform provides realistic laboratory testing, including accurate modeling of the real-world distribution system from a utility partner, real controller (ADMS and DERMs) and power (DERs) hardware, and standard communications protocols. The test results show proper functionalities of the integrated platform and performance of the peak load management of coordinated control systems. Based on the laboratory testing, the utility can set up the same grid automation system to manage DERs to achieve system-level control and operation objectives (e.g., peak load management), thus derisking potential issues (e.g., instability) for field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hardware Testing and Implementation of RapidIO Protocol on the ISAAC iBoard for Use in the NEXUS Testbed

I am assisting the NEXUS (NEXtbUS) and ISAAC (Instrument ShAred Artifact for Computing) teams in achieving a highly reusable, highly configurable FPGA (Field Programmable Gate Array) system which uses a unified, high-speed bus standard. One of my tasks is to verify that all new ISAAC iBoards features are functioning as expected by using my previous builds to test these features and resolving any errors found. My other task is to investigate and implement the RapidIO protocol and to implement it onto the new ISAAC iBoards to be used in the NEXUS testbed. Completing these tasks will demonstrate the potential of both NEXUS and ISAAC technology. This will allow others to see the power in making use of a unified, modular system.

RapidIO Protocol↗

Performance Evaluation of Data-Enhanced Hierarchical Control for Grid Operations

This paper presents a hardware-in-the-loop (HIL) simulation to evaluate the performance of voltage regulation of Data-Enhanced Hierarchical Control (DEHC). This DEHC uses an advanced distribution management system (ADMS) for grid operations to control legacy and grid-edge devices and coordinate with distributed energy management systems (DERMS) to manage high penetrations of photovoltaics (PV) on a utility distribution system. The HIL platform provides realistic laboratory testing, including accurate modeling (legacy devices, grid-edge devices, and PV) of the real-world distribution system from a utility partner, a real controller (ADMS), software controller DERMS, hardware grid-edge devices, and standard communications protocols. The test results demonstrate functionalities of the integrated platform and the performance of voltage regulation of the coordinated control systems. Based on laboratory testing, the utility can set up the same grid-automation system to manage DERs, legacy devices, and grid-edge devices to achieve their system-level control and operation objectives (e.g., voltage regulation), thus de-risking potential issues such as instability for field deployment.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Characterization of Low Frequency Auditory Filters

The purpose of this study is to characterize auditory filters at low frequencies, defined as below about 100 Hz. Three experiments were designed and executed. They were conducted in the Exterior Effects Room at the NASA Langley Research Center, a psychoacoustic facility designed for presentation of aircraft flyover sounds to groups of test subjects. The first experiment measured 36 subjects’ hearing threshold for pure tones (at 25, 31.5, 40, 50, 63 and 80 Hz) in “quiet” conditions. The subjects, male and female, had a wide age range. This experiment allowed the performance of the test facility to be assessed and also provided screened test subjects for participation in subsequent experiments. The second and third experiments used 20 and 10 test subjects, respectively, and measured psychophysical tuning curves (PTCs) that describe auditory filters with center frequencies of approximately 63 and 50 Hz. The latter is assumed to be the lowest (bottom) auditory filter; thus, sounds at frequencies below about 50 Hz are perceived via the lower skirt of this lowest filter. All experiments used an adaptive, three-alternative forced-choice test procedure using either variable level tones or variable level, narrowband noise maskers. Measured PTCs were found to be very similar to other recently published data, both in terms of mean values and intersubject variation, despite different experimental protocols, different test facilities, and a wide range in subjects’ age.

Rafaelof, Menachem↗