Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMOCOUPLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Apollo 15 measurement of lunar surface brightness temperatures - Thermal conductivity of the upper 1.5 meters of regolith.

In situ measurements of lunar surface brightness temperatures made as a part of the Apollo Lunar Surface Experiments Package at the Apollo 15 Hadley Rille landing site are reported. Data derived from five thermocouples of the Heat Flow Experiment, which are lying on or just above the surface, are used to examine the thermal properties of the upper 15 cm of the lunar regolith using eclipse and nighttime cool-down temperatures. Application of finite-difference techniques in modeling the lunar soil shows that the thermocouple data are best fit by a model consisting of a low-density and low-thermal conductivity surface layer approximately 2 cm thick overlying a region increasing in conductivity and density with depth. Conductivities on the order of 0.00001 W per cm per deg K are postulated for the upper layer, with conductivity increasing to the order of 0.0001 W per cm per deg K at depths exceeding 20 cm. An increase in mean temperature with depth indicates that the ratio of radiative to conductive transfer at 350 K is 2.7 for at least the upper few centimeters of lunar soil; this value is nearly twice that measured for returned lunar fines.

Keihm, S. J.↗

Surface brightness temperatures at the Apollo 17 heat flow site - Thermal conductivity of the upper 15 cm of regolith

Lunar surface brightness temperatures derived as part of the Apollo 17 heat flow experiment are reported. Nighttime surface temperatures, calculated from the data provided by two thermocouples suspended about 15 cm above the lunar surface, are used to determine the conductivity profile of the upper 15 cm of regolith at the ALSEP site. The surface reaches a maximum temperature of 384 (plus or minus 6) K at lunar noon and cools to a minimum temperature of 102 (plus or minus 1.5 K) at the end of the lunar night. Conductivities of the order of .000015 W/cm-deg K are postulated for a 2-cm porous surface layer overlying more compact regolith material with conductivities in the range of .0001 to .00015 W/cm-deg K between 2 and 15 cm. A mean surface temperature of 216 (plus or minus 5) K is deduced from the thermocouple data. The 256 K temperature measured by the probe sensors at 130 cm thus indicates that a large mean temperature gradient exists at the Apollo 17 site.

Keihm, S. J.↗

Analysis of a Pneumatic Probe for Measuring Exhaust-Gas Temperatures with Some Preliminary Experimental Results

A pneumatic probe based on continuity of mass flow through two restrictions separated by a cooling chamber was constructed to measure gas temperature at and beyond the limit of thermocouples. This probe consisted of a subsonic flat-plate orifice for the first restriction and a sonic-flow converging-diverging nozzle for the second restriction. The effect of variation in gas constants on the calibration is examined for common engine-exhaust gases. A high-temperature wind tunnel that allowed calibration of the probe at temperatures up to 2000 deg R and. Mach numbers up to 0.8 is described. Agreement to better than 30 deg R between pneumatic probe indication and the indication of a rake of radiation shielded thermocouples indicates that extrapolation of the calibration to higher temperatures is possible with fair accuracy

Scadron, Marvin D.↗

Forearm blood flow during body temperature transients produced by leg exercise

Subjects exercised for 30 min on a bicycle ergometer at 30, 50, and 70% of maximal aerobic power in ambient temperatures of 15, 25, and 35 C and vapor pressures of less than 18 torr. Exercise was used to vary internal temperature during an experiment, and different ambient temperatures were used to vary skin temperatures independently of internal temperature. Forearm skin temperature was fixed at about 36.5 C. Esophageal temperature was measured with a thermocouple at the level of the left atrium, and mean skin temperature was calculated from a weighted mean of thermocouple temperatures at eight skin sites. Forearm blood flow was measured by electrocapacitance plethysmography. Data are well accounted for by a linear equation independent of exercise intensity, although some subjects showed an equivocal vasodilator effect of exercise.

Wenger, C. B.↗

Thermoregulatory control of finger blood flow

In the present experiment, exercise was used to vary internal temperature and ambient air heat control was used to vary skin temperature. Finger temperature was fixed at about 35.7 C. Esophageal temperature was measured with a thermocouple at the level of the left atrium, and mean skin temperature was calculated from a weighted mean of thermocouple temperatures at different skin sites. Finger blood flow was measured by electrocapacitance plethysmography. An equation in these quantities is given which accounts for the data garnered.

Wenger, C. B.↗

Results of aerodynamic heat transfer tests of a 0.0175-scale model of the Rockwell International Space Shuttle Orbiter 139 (model number 22-0) in the NASA/Ames 3.5-foot hypersonic wind tunnel (test OH6)

The results of a hypersonic wind tunnel test program conducted using a 0.0175 scale thin-skin thermocouple model of the Space Shuttle Orbiter to obtain aerodynamic heat transfer data on the Orbiter under simulated reentry conditions were presented. The test program was conducted at a Mach number of 7.3 and a freestream Reynolds number ranging between 1.0 and 6.0 million/foot. The model was tested for angles of attack ranging between 10 deg and 30 deg and a sideslip angle of 0 deg. The model was constructed of 15-5 PH stainless steel with the instrumented areas machined to a nominal skin thickness of 0.030 in. The model instrumentation consisted of 288 iron-constantan thermocouples spot welded to the skin inner surface, but only 75 of these were used in this test program. A high-speed, analog-to-digital data acquisition system was used to record data on magnetic tape.

Dye, W. H.↗

Shock interference peak heating measurements using phase change coatings

The phase change coating technique is used to obtain peak heating measurements in shock interference flow regions with high surface shear and heating. This technique provides heat transfer coefficients which are determined by measuring the time for a point on the surface to reach the phase change temperature of the thin fusible coating. Measurements were conducted on a 5.08-cm diameter hemisphere-cylinder made of silica based epoxy at Mach 6 for free stream Reynolds numbers of 3.3 to 25.6 million per meter. A sketch of the shock interference pattern produced by a flat plate shock generator is included. Heating data obtained on a 5.08-cm diameter stainless steel hemispherical model instrumented with thermocouples is presented for the purpose of comparing the phase change technique with the thermocouple-calorimeter technique.

Keyes, J. W.↗

Results of an investigation of the space shuttle integrated vehicle aerodynamic heating characteristics obtained using the 0.0175-scale model 60-OTS in AEDC tunnel A during tests IH41 and IH41A

A thin skin thermocouple test was conducted to obtain heat-transfer data on the space shuttle integrated vehicle during the ascent phase of the flight profile. The test model was the 0.0175-scale thin skin thermocouple model (60-OTS) of the Rockwell International vehicle 5 configuration. The test was conducted at nominal Mach numbers of 2.5, 3.5, 4.5, and 5.5, and a free stream unit Reynolds number of 5 million per ft. Heat transfer data were obtained for angles of attack of 0, + or - 5, and 10 deg and yaw angles of 0, 3, and 6 deg. The integrated vehicle model was tested with the external tank configured with both a smooth ogive nose and an ogive nose with a spherical nose tip (nipple nose). The remainder of the test was conducted with the external tank installed alone in the tunnel.

Cummings, J. W.↗

An analytical and experimental study for surface heat flux determination

A numerical method by which data from a single embedded thermocouple can be used to predict the transient thermal environment for both high- and low-conductivity materials is described. The results of an investigation performed to verify the method clearly demonstrate that accurate transient surface heating conditions can be obtained from a thermocouple 1.016 cm from the surface in a low-conductivity material. Space Shuttle Orbiter thermal protection system materials having temperature- and pressure-dependent properties and typical Orbiter entry heating conditions were used to verify the accuracy of the analytical procedure. Analytically generated, as well as experimental, data were used to compare predicted and measured surface temperatures.

Williams, S. D.↗

Precision temperature gradient measurements on window glass

Surface temperature gradients were measured with miniature thermocouples installed in a 58.5 cm (23-inch) square window. Test measurements at 25 locations were made under vacuum and with the window operating in radiant heat transfer mode. The analysis of thermocouple design and installation is presented along with a lead wire routing scheme to allow for both differential and absolute temperature measurements while using a minimum number of signal feedthru paths through the test chamber wall. Typical test data and operational precautions are presented along with the accuracy analysis for installation effects and measurement effects to support differential temperature measurement precision values of + or - 0.06 C RMS + or - 0.1 F RMS).

Mikk, G.↗

Heat-pipe sensor for remote leveling

System gives level readings in inaccessible areas. Level sensor is equipped with three thermocouples used to measure temperature differences that arise when pipe is tilted. When platform on which pipe is resting is level, three thermocouple recordings are identical. When readings are unequal, platform is leveled by remote control. System can replace expensive optical equipment and can function in cold, vacuum, and hot humid environments that produce nonlinear expansion and contraction in conventional equipment. Other advantages include low cost, no moving parts, and operation in toxic environments.

Marshburn, J. P.↗

Temperature controller adapts to fatigue tester

Identical blocks of aluminum, held against front and back of specimen, each contain electrical heaters, liquid nitrogen cavity with input and exhaust tubes, and thermocouple. Thermocouples are connected to control unit, which adjusts specimen temperature during fatigue tests over range of 850 degrees F.

Imig, L. A.↗

Thin film temperature sensor

Thin film surface temperature sensors were developed. The sensors were made of platinum-platinum/10 percent rhodium thermocouples with associated thin film-to-lead wire connections and sputtered on aluminum oxide coated simulated turbine blades for testing. Tests included exposure to vibration, low velocity hydrocarbon hot gas flow to 1250 K, and furnace calibrations. Thermal electromotive force was typically two percent below standard type S thermocouples. Mean time to failure was 42 hours at a hot gas flow temperature of 1250 K and an average of 15 cycles to room temperature. Failures were mainly due to separation of the platinum thin film from the aluminum oxide surface. Several techniques to improve the adhesion of the platinum are discussed.

Grant, H. P.↗

Comparison of Orbiter STS-2 development flight instrumentation data with thermal math model predictions

Thermal performance verification of Reusable Surface Insulation (RSI) has been accomplished by comparisons of STS-2 Orbiter Flight Test (OFT) data with Thermal Math Model (TMM) predictions. The OFT data was obtained from Development Flight Instrumentation RSI plug and gap thermocouples. Quartertile RSI TMMs were developed using measured flight data for surface temperature and pressure environments. Reference surface heating rates, derived from surface temperature data, were multiplied by gap heating ratios to obtain tile sidewall heating rates. This TMM analysis resulted in good agreement of predicted temperatures with flight data for thermocouples located in the RSI, Strain Isolation Pad, filler bar and structure.

Norman, I.↗

Predictions of entry heating for lower surface of shuttle orbiter

A broad base of thermocouple and phase change paint data was assembled and correlated to the nominal design 14414.1 and proposed STS-1 (first flight of the space transportation system) entry trajectories. Averaged data from phase change paint tests compared favorably with thermocouple data for predicting heating rates. Laminar and turbulent radiation equilibrium heating rates were computed on the lower surface of the Shuttle orbiter for both trajectories, and the lower surface center line results were compared both with aerodynamic heating design data and with flight values from the STS-1 and STS-2 trajectories. The peak laminar heating values from the aerodynamic heating design data book were generally 40 to 60 percent higher than the laminar estimates of this study, except at the 55 percent location of maximum span where the design data book values were less than 10 percent higher. Estimates of both laminar and turbulent heating rates compared favorably with flight data.

Edwards, C. L. W.↗

Fabricating Thin-Shell Heat-Transfer Models

Freestanding shells produced for experimental aerodynamic-heating tests. Heat transfer shells require several steps and several precise molds. First, interlocking aluminum male and female molds fabricated. Holes for thermocouples drilled through male mold at desired locations. Wires having same diameter as thermocouple wire placed through holes in male mold flush to female mold. Epoxy exposed to vacuum to remove air bubbles poured between male and female molds to form thin female mold. Once mold cured, wires removed and aluminum molds separated.

Avery, D. E.↗

Dynamic gas temperature measurement system

The development of an advanced measuring system which measures the rapidly varying gas temperature at the exit of an aircraft jet engine combustor during ground based testing of hot section components was identified. Sensor guidelines, technical approach/program schedule, and the accomplishments are reviewed. The environment of a present generation combustor is shown. The method uses two beadless junctions type-B thermocouples to measure heat transfer coefficient in situ. Heat conduction effects are shown by a finite element model of the thermocouple.

Elmore, D.↗

Transient technique for measuring heat transfer coefficients on stator airfoils in a jet engine environment

A transient technique was used to measure heat transfer coefficients on stator airfoils in a high-temperature annular cascade at real engine conditions. The transient response of thin film thermocouples on the airfoil surface to step changes in the gas stream temperature was used to determine these coefficients. In addition, gardon gages and paired thermocouples were also utilized to measure heat flux on the airfoil pressure surface at steady state conditions. The tests were conducted at exit gas stream Reynolds numbers of one-half to 1.9 million based on true chord. The results from the transient technique show good comparison with the steady-state results in both trend and magnitude. In addition, comparison is made with the STAN5 boundary layer code and shows good comparison with the trends. However, the magnitude of the experimental data is consistently higher than the analysis.

Gladden, H. J.↗