At least 559 records · Page 31

Assessment of Readout Techniques for Passive Monitors

This fiscal year (FY) 2023 report on passive temperature sensors covers two main objectives: to demonstrate that the optical dilatometer can successfully process disc shaped silicon carbide (SiC) temperature monitors (TMs), and to demonstrate proof of concept for using the capacitance readout method to read printed melt wires. The SiC objective was successfully met by annealing and analyzing, via optical dilatometry, all eight 3-mm SiC discs provided by the Nuclear Science User Facilities (NSUF) Idaho State University (ISU) Nanostructured Steels for Enhanced Radiation Tolerance (N SERT) experiment, which was irradiated at Idaho National Laboratory (INL)’s Advanced Test Reactor (ATR). Per the ISU N SERT experiment, capsule 1 (KGT 3828 1 and KGT 3828-2) had a design temperature of 300°C +/- 50°C and an exposure of 2 dpa +/- 10%; capsule 2 (KGT 4600 and KGT 4609) had a design temperature of 300°C +/- 50°C and an exposure of 6 dpa +/- 10%; capsule 3 (KGT 4639 C and KGT 4639-D) had a design temperature of 500°C +/- 50°C and an exposure of 6 dpa +/- 10%; and capsule 4 (KGT 3841 3 and KGT 3841 4) had a design temperature of 500°C +/- 50°C and an exposure of 2 dpa +/- 10%. The target exposure rates, in dpa, are the neutron damage for various types of nanostructured steels. All but three SiC TMs (KGT 4600, KGT 4639 D, and KGT 3841 4) revealed averaged peak irradiation temperatures that fell within the design temperature ranges. The three SiC TMs that did not fall within the design temperatures ranges were at least 100°C below that target temperature. Furthermore, SiC TM KGT 3841 C revealed two irradiation regimes: one closer to the 300°C design temperature, and the other closer to the 500°C design temperature. Also, all the SiC TMs’ averaged peak irradiation temperatures came in anywhere between 20°C and 240°C below the irradiation temperatures predicted by the thermal models. This showed the optical dilatometry method to be a reliable and less time intensive process for determining averaged peak irradiation temperatures from passive SiC TMs such as rods and discs. Under the Advanced Sensors and Instrumentation (ASI) program in FY-23, Boise State University (BSU) proposed to demonstrate proof of concept for using a capacitance readout technique applicable to printed melt wires; however, they were stymied by the complexity of the capacitance readout method. In support of the BSU work, INL developed an additively manufactured (AM) ceramic package for encapsulating the new melt wires. Inks were synthesized at BSU that used new protocols rather than following previously established protocols implemented at INL, and testing of various temperatures was conducted at BSU to evaluate the melting behaviors of the printed melt wires. The result was that the capacitance readout technique showed promise but also created more challenges than originally anticipated. For example, the tin ink synthesized at BSU showed unusual melting behaviors that did nothing to enhance the performance of the final printed melt wire prototype in terms of the capacitance readout method. To make the proof of concept work when applied to the printed melt wires, the ASI program would need to invest further resources and time. Consequently, the program is not planning to continue this proof of concept work in FY-24, based on the progress and findings achieved in FY-23.

36 MATERIALS SCIENCE↗

Theoretical and experimental investigation of evanescent-wave absorption sensors for extreme temperature applications

Recently, significant developments in evanescent wave absorption sensors have been demonstrated for high temperature sensing applications based upon the optical responses of advanced thin film materials. We will demonstrate how such sensors can be utilized in a mode that allows for chemical or temperature sensing starting from basic theoretical considerations. We will also present experimental high temperature sensing results for fabricated sensors. Potential applications of the sensors to be discussed include a range of high temperature systems relevant for fossil energy and combustion monitoring such as industrial combustors or reaction vessels, solid oxide fuel cells, and gas turbines. In these applications, even a small increase in operating efficiency realized via careful observation of in-process parameters and implementation of real-time process controls can result in dramatic savings across the energy industry, illustrating the necessity of pursuing such techniques. It is hoped that sensors of the type described here will allow for unprecedented measurement-access to processes which present challenging high-temperature and chemically reactive environments.

47 OTHER INSTRUMENTATION↗

Method and apparatus for measuring temperatures in fabrics and flexible thermal insulations

A temperature sensor uses a type R thermocouple wire element in a ceramic sheath to sense temperatures up to 3,200 deg F., and is particularly suitable for flexible insulations. The sensor includes a thermocouple wire embedded in a sheath having two sections disposed at right angles to each other. The junction of the thermocouple is located at one end of one of the sections and the lead wires extend from the other section. The section which includes the junction is secured to a flexible surface with ceramic cement.

Kourtides, Demetrius A.↗

Intelligent Data Transfer for Multiple Sensor Networks over a Broad Temperature Range

A sensor network may be configured to operate in extreme temperature environments. A sensor may be configured to generate a frequency carrier, and transmit the frequency carrier to a node. The node may be configured to amplitude modulate the frequency carrier, and transmit the amplitude modulated frequency carrier to a receiver.

Krasowski, Michael↗

MODIS On-Board Blackbody Function and Performance

Two MODIS instruments are currently in orbit, making continuous global observations in visible to long-wave infrared wavelengths. Compared to heritage sensors, MODIS was built with an advanced set of on-board calibrators, providing sensor radiometric, spectral, and spatial calibration and characterization during on-orbit operation. For the thermal emissive bands (TEB) with wavelengths from 3.7 m to 14.4 m, a v-grooved blackbody (BB) is used as the primary calibration source. The BB temperature is accurately measured each scan (1.47s) using a set of 12 temperature sensors traceable to NIST temperature standards. The onboard BB is nominally operated at a fixed temperature, 290K for Terra MODIS and 285K for Aqua MODIS, to compute the TEB linear calibration coefficients. Periodically, its temperature is varied from 270K (instrument ambient) to 315K in order to evaluate and update the nonlinear calibration coefficients. This paper describes MODIS on-board BB functions with emphasis on on-orbit operation and performance. It examines the BB temperature uncertainties under different operational conditions and their impact on TEB calibration and data product quality. The temperature uniformity of the BB is also evaluated using TEB detector responses at different operating temperatures. On-orbit results demonstrate excellent short-term and long-term stability for both the Terra and Aqua MODIS on-board BB. The on-orbit BB temperature uncertainty is estimated to be 10mK for Terra MODIS at 290K and 5mK for Aqua MODIS at 285K, thus meeting the TEB design specifications. In addition, there has been no measurable BB temperature drift over the entire mission of both Terra and Aqua MODIS.

Xiaoxiong, Xiong↗

Waveguide-based ultrasonic and far-field electromagnetic sensors for downhole reservoir characterization.

This report summarizes the first year research and development effort leading to development of high-temperature sensors for enhanced geothermal systems. It covers evaluation of ultrasonic and electromagnetic (EM) techniques applied to temperature measurement and flow characterization. On temperature measurement, we have evaluated both microwave radiometry and ultrasonic techniques for temperature gradient and profile measurements. Different antenna designs are evaluated and array loop antenna design is selected for further development. We have also evaluated ultrasonic techniques for total flow characterization, which includes using speed of sound to determine flow temperature, measuring acoustic impedance to estimate fluid density, and using cross-correlation technique to determine the mass flow rate. Method to estimate the flow enthalpy is briefly discussed. At end, the need and proposed techniques to characterize the porosity and permeability of a hot dry rock resource are presented.

15 GEOTHERMAL ENERGY↗

Thermal design of the Wide Field/Planetary Camera

The Wide Field/Planetary Camera is an imaging system developed by the Jet Propulsion Laboratory for the NASA Hubble Space Telescope currently scheduled to be launched in December 1989 aboard the space shuttle. The temperature control design of the instrument utilizes multilayered insulation, electric resistance heaters, aluminum/ammonia heat pipes, thermoelectric coolers, temperature control coatings, and space radiators. A feedback control system maintains stable sensor temperatures. Thermal capacitance maintains stable optics and electronics temperatures during transient conditions. Schedule slips and launch delays have allowed extensive thermal testing of the instrument. Six instrument thermal vacuum tests and a spacecraft thermal vacuum test were performed. Several modifications have been made to the instrument to correct icing and contamination problems that have been discovered during thermal vacuum testing. This paper describes the thermal design, last instrument thermal vacuum test, results, and thermal model correlation.

Garcia, R. D.↗

Microwave Treatment for Cardiac Arrhythmias

Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about six gigahertz. A computer simulation provides initial screening capabilities for an antenna such as antenna, frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 Gigahertz and 12 Gigahertz is applied to monopole microwave radiator having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may be used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

Arndt, G. Dickey↗

Transcatheter Antenna For Microwave Treatment

Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about six gigahertz. A computer simulation provides initial screening capabilities for an antenna such as antenna, frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 Gigahertz and 12 Gigahertz is applied to monopole microwave radiation having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may he used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

Arndt, G. Dickey↗

In Vivo Simulator for Microwave Treatment

Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about 6 GHz. A computer simulation provides initial screening capabilities for an antenna such as antenna. frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 GHz and 12 GHz is applied to monopole microwave radiator having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may be used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

Arndt, G. Dickey↗

Comparison of Near-Surface Air Temperatures and MODIS Ice-Surface Temperatures at Summit, Greenland (2008-2013)

We have investigated the stability of the MODerate resolution Imaging Spectroradiometer (MODIS) infrared-derived ice surface temperature (IST) data from Terra for use as a climate quality data record. The availability of climate quality air temperature data (TA) from a NOAA Global Monitoring Division observatory at Greenlands Summit station has enabled this high temporal resolution study of MODIS ISTs. During a 5 year period (July 2008 to August 2013), more than 2500 IST values were compared with 3-minute average TA values derived from the 1-minute data from NOAAs primary 2 m air temperature sensor. These data enabled an expected small offset between air and surface temperatures at this the ice sheet location to be investigated over multiple annual cycles.

Greenland↗

Analysis of first order reversal curves in the thermal hysteresis of spin-crossover nanoparticles within the mechanoelastic model

The recently obtained spin-crossover nanoparticles are possible candidates for applications in the recording media industry as materials for data storage, or as pressure and temperature sensors. For these applications, the intermolecular interactions and interactions between spin-crossover nanoparticles are extremely important, as they may be essential factors in triggering the transition between the two stable phases: the high-spin and low-spin ones. In order to find correlations between the distributions in size and interactions and the transition temperatures distribution, we apply the FORC (First Order Reversal Curves) method, using simulations based on a mechanoelastic model applied to 2D triangular lattices composed of molecules linked by springs and embedded in a surfactant. We consider two Gaussian distributions: one is the size of the nanoparticles and another is the elastic interactions between edge spin-crossover molecules and the surfactant molecules. In order to disentangle the kinetic and non-kinetic parts of the FORC distributions, we compare the results obtained for different temperature sweeping rates. We also show that the presence of few larger particles in a distribution centered around much smaller particles dramatically increases the hysteresis width.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved Stratospheric Temperature Retrievals for Climate Reanalysis

The Data Assimilation Office (DAO) is embarking on plans to generate a twenty year reanalysis data set of climatic atmospheric variables. One of the focus points will be in the evaluation of the dynamics of the stratosphere. The Stratospheric Sounding Unit (SSU), flown as part of the TIROS Operational Vertical Sounder (TOVS), is one of the primary stratospheric temperature sensors flown consistently throughout the reanalysis period. Seven unique sensors made the measurements over time, with individual instrument characteristics that need to be addressed. The stratospheric temperatures being assimilated across satellite platforms will profoundly impact the reanalysis dynamical fields. To attempt to quantify aspects of instrument and retrieval bias we are carefully collecting and analyzing all available information on the sensors, their instrument anomalies, forward model errors and retrieval biases. For the retrieval of stratospheric temperatures, we adapted the minimum variance approach of Jazwinski (1970) and Rodgers (1976) and applied it to the SSU soundings. In our algorithm, the state vector contains an initial guess of temperature from a model six hour forecast provided by the Goddard EOS Data Assimilation System (GEOS/DAS). This is combined with an a priori covariance matrix, a forward model parameterization, and specifications of instrument noise characteristics. A quasi-Newtonian iteration is used to obtain convergence of the retrieved state to the measurement vector. This algorithm also enables us to analyze and address the systematic errors associated with the unique characteristics of the cell pressures on the individual SSU instruments and the resolving power of the instruments to vertical gradients in the stratosphere. The preliminary results of the improved retrievals and their assimilation as well as baseline calculations of bias and rms error between the NESDIS operational product and col-located ground measurements will be presented.

Rokke, L.↗

Development of copper thiolate organometallic compound as thermal sensitive coating for energy storage system safety

Safety and reliability are primary concerns for the deployment of lithium-ion batteries, especially in electric vehicles (EV) and larger-scale energy storage systems (ESS). Current technology in battery management systems (BMS) includes cell voltage monitoring and positioning temperature sensors in selected locations. For a system with hundreds to thousands of individual batteries, single-point temperature monitoring is inadequate to detect hot spots and cell overheating, which could lead to thermal runaway. Here, we have developed a temperature-sensitive copper-thiol compound that can be directly coated onto battery pouch foils to enable early detection of thermal runaway. Upon reaching specific temperatures, this compound releases a sulfur-containing detectable gas, which can be identified using chemically specific gas sensors to trigger an early warning signal. Such a signal propagate through air offers broad signal coverage and enables a more comprehensive approach to large-area temperature monitoring. The Cu-ethanethiol coating is designed to release volatile gases when the substrate surface temperature exceeds 70 °C, with continuous outgassing as the temperature increases. The compound is composed of Cu, S, Cl, hydrocarbons and trace amounts of oxygen. Upon heating, the oxidation state of Cu(I) transitions to Cu (II), accompanied by gas release. Thermogravimetric analysis coupled with mass spectrometry correlated well with the onset of gas release temperature and emission of sulfur-containing volatile gases. Additionally, an acrylic overcoat is applied to enhance the adhesion of the thermally sensitive compound film to the battery pouch foil. This coating is expected to offer an additional safety layer for ESS, alerting possible thermal runaway events before a failure occurs, thereby allowing sufficient time to implement a mitigation plan.

Early warning systems↗

A high-temperature heat flux sensor using the transverse Seebeck effect in elemental rhenium

Heat flux sensors compatible with hot environments are critical to advance aerospace, materials, and energy generation technologies that cope with extreme thermal conditions. In this work, we report on the development and characterization of a high-temperature heat flux sensor using the transverse Seebeck effect in rhenium single crystals. The sensor leverages refractory alloys and ceramics compatible with temperatures exceeding 1000 °C. The heat flux sensor was characterized from room temperature to 500 °C using a temperature-controlled calibration facility. At constant temperature, the sensor’s voltage output is linear with respect to the absorbed heat flux. The responsivity of the sensor varies with temperature, from 1.3 μV/(W/cm 2 ) at room temperature to −3.2 μV/(W/cm 2 ) at 500 °C, increasing monotonically in magnitude after changing sign from positive to negative at approximately 300 °C. The experimental results are in good agreement with analytical predictions of the sensor’s temperature-dependent responsivity, which suggest a further increase in magnitude up to −7.4 μV/(W/cm 2 ) at 1000 °C. These results highlight the unique characteristics of rhenium as a TSE transducer. The design offers compatibility with a wide range of operating temperatures and yields a measurement sensitivity that increases as the environmental conditions become more challenging.

20 FOSSIL-FUELED POWER PLANTS↗

Wireless Temperature Sensing Method Using no Electrical Connections

A wireless temperature sensor includes an electrical conductor and a material spaced apart from the conductor and located within one or more of the responding electric field and responding magnetic field of the conductor. The conductor is electrically unconnected and is shaped for storage of an electric field and a magnetic field. In the presence of a time-varying magnetic field, the conductor resonates to generate harmonic electric and magnetic field responses, each of which has a frequency associated therewith. The material is selected such that it experiences changes in one of dielectric properties and magnetic permeability properties in the presence of a temperature change. Shifts from the sensor's baseline frequency response indicate that the material has experienced a temperature change.

Woodard, Stanley E.↗

TDD LoRa and Delta Encoding in Low-Power Networks of Environmental Sensor Arrays for Temperature and Deformation Monitoring

Abstract Densely distributed sensor networks can revolutionize environmental observations by providing real-time data with an unprecedented spatiotemporal resolution. However, field deployments often pose unique challenges in terms of power provisions and wireless connectivity. We present a framework for wirelessly connected distributed sensor arrays for near-surface temperature and/or deformation monitoring. Our research focuses on a novel time division duplex implementation of the LoRa protocol, enabling battery powered base stations and avoiding collisions within the network. In order to minimize transmissions and improve battery life throughout the network, we propose a dedicated delta encoding algorithm that utilizes the spatial and temporal similarity in the acquired data sets. We implemented the developed technologies in a AA battery powered hardware platform that can be used as a wireless data logger or base station, and we conducted an assessment of the power consumption. Without data compression, the projected battery life for a data logger is 4.74 years, and a wireless base stations can last several weeks or months depending on the amount of network traffic. The delta encoding algorithm can further improve this battery life with a factor of up to 3.50. Our results demonstrate the viability of the proposed methods for low-power environmental wireless sensor networks.

54 ENVIRONMENTAL SCIENCES↗